Overhauling And De-Scaling Of Central Heating System Including Rewinding Of Motors Replacement Of Nozzles, Replacement Of Defective Meters, Fixing Of Thermo Meters Overload Etc. During The Year 2021-2022 Of Jnk High Court Complex Srinagar And Rnb Ch , High Court-Jammu And Kashmir

Public Works Department-PWD has published Overhauling And De-Scaling Of Central Heating System Including Rewinding Of Motors Replacement Of Nozzles, Replacement Of Defective Meters, Fixing Of Thermo Meters Overload Etc. During The Year 2021-2022 Of Jnk High Court Complex Srinagar And Rnb Ch . Submission Date for this Tender is 06-11-2021. Electrical Maintenance Tenders in High Court Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

29736131
Overhauling And De-Scaling Of Central Heating System Including Rewinding Of Motors Replacement Of Nozzles, Replacement Of Defective Meters, Fixing Of Thermo Meters Overload Etc. During The Year 2021-2022 Of Jnk High Court Complex Srinagar And Rnb Ch
Open Tender
Indian
Jammu And Kashmir
High Court
06-11-2021

Tender Details

Overhauling And De-Scaling Of Central Heating System Including Rewinding Of Motors Replacement Of Nozzles, Replacement Of Defective Meters, Fixing Of Thermo Meters Overload Etc. During The Year 2021-2022 Of Jnk High Court Complex Srinagar And Rnb Ch Overhauling And De-Scaling Of Central Heating System Including Rewinding Of Motors Replacement Of Nozzles, Replacement Of Defective Meters, Fixing Of Thermo Meters Overload Etc. During The Year 2021-2022 Of Jnk High Court Complex Srinagar And Rnb Ch

Key Value

Document Fees
INR 300 /-
EMD
Refer document
Tender Value
INR 7.50 Lakhs /-

BOQ Items

Name of Work:Overhauling and descaling of central heating system including rewinding of motors replacement of nozzles, replacement of defective meters, fixing of thermo meters overload etc. during the year 2021-2022 of J&K High Court Complex Srinagar andR&B Chief Engineeringoffice Complex at Rajbagh Srinagar.
Sl. No. Item Description
1Opening of 400 WA LDO Boiler for taking out steel water heating coil with chain pulley block and refitting of the same after descaling and repairs, including cost of the gaskets, washers etc complets job at J&K High Court Srinagar.
2Descaling of 400 WA LDO Boiler with chemicals, pumping out deposits on the surface of steel coils and pipes of hot water circulation at J&K High Court Srinagar.
3Opening of 600 WA HSD Boiler for taking out steel water heating coil with chain pulley block and refitting of the same after descaling and repairs, including cost of the gaskets, washers etc complete job at J&K High Court Srinagar.
4Descaling of 600 WA HSD Boiler with chemicals, pumping out deposits on the surfaces of steel coils and pipes of hot water circulation at J&K High Court Srinagar.
5Opening of 200WA HSD Boiler for taking out steel water heating coil with chain pulley block and refitting of the same after descaling and repairs, including cost of gaskets, washers etc complete job at Chief Engineer Complex R&B Rajbagh.
6Descaling of 200WA HSD Boiler with chamicals, pumping out desposits on the suface of steel coils and pipes of hot water circulations at Chief Engineer Complex R&B Rajbagh.
7Providing and fixing of refectory cement at the bottom of L.D.O 400 WA Boiler complete job at J&K High Court Srinagar.
8Providing and fixing of refectory cement at the back of 600 WA HSD Boilercompletes job at J&K High Court complex Srinagar.
9Providing and fixing of refectory cement at back of H.S.D 200 WA Boiler complete job at Chief Engineer Complex Rajbagh Srinagar.
10Gerneral check up and cleaning of Air Handling units for free flow of air by opening of radiators/blowers including chemical washing of coils and cleaning of shafts, greasing to bearings includng carriage of coils to work shop after descaling back to site of work including fitting of bearing shaft complete job. includng replacement of AHU bearings of reputed make if required at J&K High Court Srinagar.
11AHU with 5No. Coiles
12AHU with 6No. Coiles
13Providing and fixing of contactors and overloads of approved make.
14A: Contactors
15ML-1/1.5(For LDO boilers of approved make.
166-10 Amp (for HSD 200WA of approved make)
1716 Amp (for 600 WA HSD boiler of approved make.
18B: Overload
1935 Amp
2020-25 Amp ( For 600 Wa Boiler of approvedmake)
21Opening and cleaning of radiator with blowing air and with biocorbonate solution for checking of any leakage, replacement of gaskets if needed etc and connecting back with system at Chief Engineer R&B Rajbagh Complex/ at J&K High Court Engineering Block.
22Replacement of MCB TPN of approved Quality at High Court Complex
2363 Amp
24100Amp
2532Amp
26Providing and fixing of polythene to windows and ventilators to prevent heat loss during running of central Heating system and removing of the same after conclusion of winter season to windows/ ventilators of entire High Court Complex
27Providing and fixing of wooden beading for fixing of polythieneto windows / ventilators and door blankets
283/4"" wooden beading for windows / ventilators.
291^ 1/4"" wooden beading (for doors) for blankets of advocate general litigant block / emgineering block
30Providing and fixing of Blankets o f standard quality for doors to prevent heat loss of j &k high court complex / advocate general, administrative /engineering blockincluding removal of the same after conclusion of winter season
31Rewinding of burnt out motors of different capacities including dismantlling of necessary connections, rewinding by way of replacing damaged copper wiring by suitable guage copper wire including providing and fitting of lathoride sheets, varnishing compound and other consumeable items incl. shifting to workshop by mechanical transport and back to site and installing the same and checking the performance of same in full and idle load in J&K High Court Complex Srinagar.
3215/20 HP Capacity Motors
333 HP Capacity Motor
34Upgradation of stater Delta pannels of AHU"s by way of changing complete wiring / replacing of indicators / on-off push botton / HRC Fuse / Connectors complete at j&k high court complex srinagar.
35Providing and fixing of bell type air release valve of approved quality and make.
36Providing and fixing of return valve (raidator valve ) of approved quality including dismentalling at chief Engineering complex Rajbagh.
37Replacement of Ahu belt of reputed make of various sizes for Ahu of J&K High Court Complex
38Providing and fixing of 7.5 H.P capacity motor of standard make (Mechanical seal) & type KDS- 844+ if RPM-2500/Head -38/ Dia 178/ Kcv/HP-3-5-7.5 with 50n Hz 3pH. 400v incl. Dismentalling of deffusing /burned out motors incl. Testinge and checking for performance of the same on full and ideal load at J&K high court complex.
39Providing and fixing of 5 H.P capacity motor of standard make (Mechanical seal)incl. Dismentalling of deffusing /burned out motors incl. Testinge and checking for performance of the same on full and ideal load atR&B Chief Engineering complex for make up tank in boiler plant.
40Supply / Filling of fresh filter transformer Oil at R&B Chief Engineering Complex.
41P/F metre Selec-TC 303 of standard quality as approved by engineer in charge including testing of the same after installation and dismentalling the defunct meter complete.
42P/F of nozzle (8.5 mm) of standard quality and approved make.
43P/F of photo cell - 600 WA boiler of standard quality and approved make complete.
44P/F of water pressure metre of standard quality and approved by engineer in charge
45P/F temperature guage of standard quality as approved by engineer in-chrge.
46P/F Rela Contactor for assembly lavato 230 V / 50-60hz BG 0910A of approved make and standard quality complete.
47P/installing digital room thermometres of approved quality and make complete.
48Providing / installing of Ignition tranformer for 1100Vincluding dismentling of damaged one and testing , checking and commissioning of the same under full and ideal load.
49P/F of Gate valve (32mm) of approved make and standard quality complete.
50P/F of Gate valve (50mm) of approved make and standard quality complete.
51P/F stater (32AMP) of approved make and standard quality including testing of the same and dismentalling of defunct starter complete.
52Providing hoisting fixing and placing on terrace at all levels three layer HDPE polyethylene water storage tank ISI 12701 marked indicating the BIS licence No. with cover and suitable locking arrangements and making necessary holes for inlet, outlet, nipples gate valves overflow pipes ball cock with PVC floats and base support for tank of approved make and standard quality including all necessary fittings and fixtures complete (1000 litres of capacity).
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy