Public Works Department-PWD has published Internal Electrical Work Of Integrated Covid Command Center And Other Official Building At Collectorate Campus District Bulandsahar Internal Electrical Work Of Integrated Covid Command Center And Other Official Building At Collectorate Campus District Bul. Submission Date for this Tender is 03-11-2021. Electrical Maintenance Tenders in BULANDSAHAR Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring point for light with 1.5sqmm Frlash PVC insulated multistrand copper conductor cabel in 20mm dia PVC conduit concealed in wall complete with 1.5sqmm FRLSH PVC multistrand single core copper conductor as earth wire drawn inside the conduit with GP Box modular tpe switch and ceiling rose/batten holder complete in all respect as directed in ENC including matching colour wash complete in all respect (Partly laid slab & wall) |
2 | Same as above item 1 but for 2 way light switch complete as per PS |
3 | Same as above item 1 but for Fan/Fresh Air Fans complete as per PS |
4 | Same as baove item 1 but for call bell points with modular switch complete as per PS |
5 | Same as baove item 1 but for plug point with 5amp switch and 5 pin socket |
6 | S/F of power plug with 20A/250V flesh type modular switch and 5 pin 20A/250V socket compelte as per PS |
7 | S/F of electronic fan regulator modular step type 120-280V ISI mark complete |
8 | S/F of 200A/415V TPN Fuse unit on angle bracket iron |
9 | S/F of 63A TPN MCB 10KA @ CAT-A |
10 | S/F of 6A to 32A SPMCB 10KA @ CAT-A |
11 | S/Burrying 600 x 600 x 6ma GI Plate earthing |
12 | S/F of 2 No. 8 SWG GI Wire for earthing |
13 | S/F surface mounting 8 way SPNDB with additional metal door without MCB compelte in all respect CAT-A |
14 | S/F surface /Flush mounting 4 way TPNDB Cat-A |
15 | S/F of 16 Guage MS drum duily painted with makin hole in the wall exhaust fan |
16 | Erection and Testing of celling fan and regulator room height upto 3.5 mtr complete |
17 | S/F 1 x 22 W LED tube light heavy matel body BOX type fittings including batten on surface CAT-AAA with 5 year warranty |
18 | S/F 2 x 22 W LED tube light heavy matel body BOX type fittings including batten on surface CAT-AAA with 5 year warranty |
19 | S/F LED Round Fitting 15W fittings including batten on surface CAT-AAA with 5 year warranty |
20 | ADD for extra inverting wiring point L/F/Plug with 1.5mm copper wire |
21 | S/F of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 watt confirming to IP 66 and above proection with five years warantee complete in all respect CAT-AAA |
22 | S/F Single LED light wall bracket 6 Watt complete in all respect @ CAT-AAA with 5 year warranty |
23 | S/F of Call Bell |
24 | Supply and wiring of submain with 2 No. x 6sqmm FRLSH PVC insulated 1100V Grade single core MultiFRLSH PVC insulated 1100V Grade single core MULTI PVC conduit concealed in wall compelte with 1 No. 4 sqmm as a earth copper wire drawn conduit (Partly wall & slab) |
25 | Same as above item No. 24 but for submain 2 x 4sqmm |
26 | Same as above item No. 24 but for submain 2 x 2.5 sqmm |
27 | Same as above item No. 24 but for submain 4 x 16sqmm |
28 | S/L of 70sqmm x 3.5 core aluminium cable 1100 V Grade |
29 | S/F of extention board/Computer board with modular GP Box 12 module with 3 No. modular switch and 5 pin socket compelte |
30 | S/F of sheet steel encloser surface/flush mounted fitted with 20 amp 2 pin earth metal clad plug and socket complete in all respect CAT-A |
31 | S/F of 6A to 32A DPMCB @ CAT-A |
32 | S/F of Cable gland 70 sqmm 3.5 Core Aluminium conductor PVC insulated Cable |
33 | S/F of Cable lug 70 sqmm 3.5 Core Aluminium conductor PVC insulated Cable |
34 | S/F of Cable lug 35 sqmm 3.5 Core Aluminium conductor PVC insulated Cable |
35 | S/F of danger Board |
36 | S/F of Shock treatment chart |
37 | S/F of ABC type fire exitinguiser 4.0 KG Cape |
38 | S/F of 100A, 4 Pole changeover switch complete |
39 | Supply and Errection fo factory fabricate & wired metal clad dust and vermin proof floor mounting MS channel base with bottom and top cabel enteries electrical control panel with TPN MCCB s (4 pole 36KA with thermal magnetic release) switches complete and instrument chamber etc. complete in all respect. The instrument chamber shall be seperate and shall comprise of flush type digital metering system for phase to phase voltage and signle phase voltage, current and other parameters (KVA, P, F, K, W etc) in each reading, instrument fuses, current transformer etc the panel board shall have suitable capacity electrolytic aluminium bus bars as per IS8623 or above insulated with heat shrink sleeving and mounted on non hygroscopi supports such as CMC/BMC support with deteachable side covers and shall be suitable for extention on the side of the MCBS shall be compelete with suitable cable and boxes glands and indicating lampe on incoming etc. The job includes the grounting of the board as per the directions of Engineer-in-charge. All out goings off 100 amp and shall have an ammeter. The panel board shall befabricated with CRCA sheet with a thickness of 1.6MM/2MM cubicle type switch board shall be CAT of A & B only. INCOMING 200ATPN MCCB-1 NO OUTGOING: 100A MCCB- 1 No. and 63A MCCB - 3 Nos |
40 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated sheileded with fine finned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required |
41 | Supply and fixing following modulare switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required TV Antenna socket outlet |
42 | Supplying, installation testing & commissioning of addressable manual call point complete as required |
43 | Supplying, installation testing & commissioning of addressable programmable sonunder complete as required |
44 | Supplying & laing of 2 x 1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber (EPR) insulation and LSZH inner bedding steel wire armouring & LSZH outer sheath complete as required |
45 | Direct expansion air conditioners with inverter technology Supply & installation of split direct expansion air-conditioning suitable for operaions on A/C supply single phase 50Hz 230V with hermetically sealed compressr with air cooled condenser with DC inerter technology etc. 5 star (i) 1.5 TR BEE Star rated : 5 star, EER 3.4 |
46 | Direct expansion air conditioners with inverter technology Supply & installation of split direct expansion air-conditioning suitable for operaions on A/C supply single phase 50Hz 230V with hermetically sealed compressr with air cooled condenser with DC inerter technology etc. 5 star (ii) 2.0 TR BEE Star rated : 5 star, EER 3.4 |