Jjm2021- 22 Procurement Of 7 Nos Micro Processor Based Bench Top Touch Screen Ph Meter For Various Quality Control Laboratories Of Kerala Water Authority Jjm 2021-22 Setting Up Upgradation Operation Of Laboratories For Wqms Procurement Of 7 Nos Micro Pro
Tender Overview
Project Description
Jjm2021- 22 Procurement Of 7 Nos Micro Processor Based Bench Top Touch Screen Ph Meter For Various Quality Control Laboratories Of Kerala Water Authority Jjm 2021-22 Setting Up Upgradation Operation Of Laboratories For Wqms Procurement Of 7 Nos Micro Processor Based Bench Top Touch Screen Ph Meter For Various Quality Control Laboratories Of Kerala Water Authority , Jjm-2021-22-Setting Up / Upgradation / Operation Of Laboratories For Wqm&S- Procurement Of 7 Nos Micro Processor Based Bench Top Touch Screen Ph Meter For Various Quality Control Laboratories Of Kerala Water Authority , Supply And Installation, Validation Including Warranty Of Micro Processor Based Bench Top Touch Screen Ph Meter With The Following Specifications; Ph:- Range: -2 To 20.000Ph;Resolution: 0.001 Ph; Repeatability: ±0.002Ph Or Better; Accuracy: ± 0.002 Ph; Cal.Points 5 Points ; Buffer Options: Usa, Nist, Custom; Orp:- Range: ± 1999.9 Mv Or Better; Resolution: 0.1 Mv; Repeatability:± 0.2Mv Or Better; Accuracy: ± 0.2Mv Or Better; Temperature :Range: -5°C To 100°C ; Resolution: 0.1°C;Repeatability: ±0.4°C Or Better; Accuracy: ±0.4°C Or Better ; Electrode Specification: Double Junction Toughened Glass / Unbreakable Electrode With Filling Solution; Shall Provide Atc ; Meter And Electrode Shall Be Of Same Manufacturer; Meter Features: ( I ) Should Be Touch Screen Model And The Screen Size Shall Have Minimum Size To Facilitate Easy And Convenient Operations ( Ii ) Graphical Lcd ( Iii ) Electrode Status On Screen Display ( Iv ) Calibration Due Alarm ( V ) Off Set / Slope Should Be Displayed ( Vi ) Data Logging Facility ( Vii ) Output Rs232 / Usb ( Viii ) Memory 2000 Data Sets Minimum ( Ix ) Power 230V ±10%, 50Hz Minimum ( X ) Buffer Set: Usa Ph 4.01, 7.00, 10.01 ( Minimum 100Ml Each ) ( Xi ) Should Provide Electrode Filling Solution ( Minimum 100Ml ) ( Xii ) Should Supply Non Corrosive Electrode Stand ( Xiii ) Compliance: Glp With Test Report Of The Instrument With Traceability From The Manufacturer . Values Obtained For The Ph 4.01 , 7.00 And 10.01 At 25 Degree C Shall Be Included In Test Report ( Xiv ) Should Provide Hard Copy Of User Manual With Instrument And Electrode Specification ( Xv ) Iq / Oq / Pq Documentation Shall Be Provided ( Xvi ) Crm For Calibration During Pq Shall Be Supplied By Kwa ( Xvii ) Warranty: 3Years For Meter And 1Year For The Electrode
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Oct-2021 | Amendment to NIT | Other | 16-Nov-2021 |
BOQ
| Sl. No. | Item Description |
| 1 | JJM-2021-22-Setting up / upgradation / operation of Laboratories for WQM&S- Procurement of 7 nos Micro Processor based bench top touch screen pH Meter for various Quality Control Laboratories of Kerala Water Authority |
| 2 | Supply and installation, validation including warranty of Micro processor based bench top touch screen pH meter with the following specifications; pH:- Range: -2 to 20.000pH;Resolution: 0.001 pH; Repeatability: ±0.002pH or better; Accuracy: ± 0.002 pH; Cal.Points 5 points ; Buffer options: USA, NIST, Custom; ORP:- Range: ± 1999.9 mV or better; Resolution: 0.1 mV; Repeatability:± 0.2mV or better; Accuracy: ± 0.2mV or better; Temperature :Range: -5°C to 100°C ; Resolution: 0.1°C;Repeatability: ±0.4°C or better; Accuracy: ±0.4°C or better ; Electrode specification: Double junction toughened glass / unbreakable electrode with filling solution; Shall provide ATC ; Meter and electrode shall be of same manufacturer; Meter Features:(i)Should be touch screen model and the screen size shall have minimum size to facilitate easy and convenient operations (ii) Graphical LCD (iii)Electrode status on screen display (iv) Calibration due alarm (v) Off set/slope should be displayed (vi) Data logging facility (vii) Output RS232/USB (viii) Memory 2000 data sets minimum (ix)Power 230V ±10%, 50Hz minimum (x)Buffer set: USA pH 4.01, 7.00, 10.01 (minimum 100ml each) (xi) Should provide electrode filling solution (minimum 100ml) (xii) Should supply non corrosive electrode stand (xiii) Compliance: GLP with test report of the instrument with traceability from the manufacturer . Values obtained for the pH 4.01 , 7.00 and 10.01 at 25 degree C shall be included in test report (xiv)Should provide hard copy of user manual with instrument and electrode specification (xv) IQ/OQ/PQ documentation shall be provided (xvi) CRM for calibration during PQ shall be supplied by KWA(XVii) Warranty: 3years for Meter and 1year for the electrode |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender