Uttar Pradesh Projects Corporation Limited has published Balance Work Of Main Building, Running Track And Other Civil Works At Mini Stadium G.R.B. Inter Collage Rath, District Hamirpur (U.P. . Submission Date for this Tender is 08-11-2021. Sports Complex Tenders in Rath, District Hamirpur (U.P.) Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Balance work of Main Building, Running Track and Other Civil Works at Mini Stadium G.R.B. Inter Collage Rath, District Hamirpur (U.P.) |
2 | Main Buliding |
3 | Making drain along with the apron. |
4 | Providing and Fixing 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete |
5 | Providing and laying cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded Stone aggregate 20 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
6 | 25mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. |
7 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
8 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J & N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. |
9 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) |
10 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
11 | Same as above but on wooden surface. |
12 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
13 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
14 | Running Track |
15 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. (PWD-281) |
16 | Under Drain |
17 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Slab excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. (PWD-284+2.02+234) |
18 | R.C.C. DRAIN |
19 | M.S. work in R.C.C. |
20 | M.S. or Iron work in heavy sizes such as trusses, built up gates, record rack, roof work , gates etc wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work. (PWD-503) |
21 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.(PWD-641+642) |
22 | SANITARY FIXTURES & ACCESSORIES : I |
23 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required |
24 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
25 | Same as above but for European type W.C. pan with white plastic seat and lid |
26 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
27 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
28 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
29 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required |
30 | a) One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
31 | b) Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
32 | c) Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern |
33 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
34 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore |
35 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. a) 15mm dia nominal dia. |
36 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet a) 100 mm diameter |
37 | Providing and fixing CP Brass 32 mm sizeBottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
38 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
39 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
40 | Providing and fixing Toilet paper holder a) C.P. brass |
41 | SOIL WASTE & VENT PIPES AND FITTINGS - II |
42 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110mm diameter |
43 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. a) 110mm |
44 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm |
45 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
46 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 110/90 mm diameter |
47 | NON SCHEDULE ITEMS |
48 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. |
49 | 110 mm O.D. |
50 | 90 mm O.D. |
51 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 110x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
52 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. |
53 | Size 90 mm |
54 | Size 110 mm |
55 | Supply and fixing of UPVC S.W.R. door bend confirming to IS-14735. |
56 | Size 90 mm |
57 | Size 110 mm |
58 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. |
59 | Size 90x90x90 mm |
60 | Size 110x110x110 mm |
61 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. |
62 | Size 90 mm |
63 | Size 110 mm |
64 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. |
65 | Size 75/90 mm |
66 | Size 110 mm |
67 | Providing and fixing PVC pipe confirming to IS make working pressure 6 kg/cm2 /Type-A including testing labour T&P and all complete fittings. 160 mm diameter |
68 | WATER SUPPLY PIPES AND FITTINGS - III |
69 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. |
70 | (internal work) |
71 | Exposed on wall |
72 | 32mm dia nominal bore |
73 | 50mm dia nominal bore |
74 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
75 | 32mm dia nominal bore. |
76 | 50mm dia nominal bore. |
77 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (internal work) Exposed on wall - 25mm dia nominal outer dia pipes |
78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. |
79 | 15mm dia nominal outer dia pipes |
80 | 20mm dia nominal outer dia pipes |
81 | 25mm dia nominal outer dia pipes |
82 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 a) 15mm nominal bore |
83 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore |
84 | Providing and fixing gun metal gate valve with wheel of approved quality. |
85 | 25mm dia nominal bore |
86 | 50mm dia nominal bore |
87 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
88 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
89 | INTERNAL SEWERAGE SYSTEM - IV |
90 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
91 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter |
92 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameterS.W. Pipe |
93 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
94 | 150mm diameter |
95 | 250mm diameter |
96 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
97 | 150 mm.dia. RCCPipes |
98 | 250 mm.dia. RCCPipes |
99 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design |
100 | 150 x 100 mm. size P type |
101 | With Sewer bricks conforming to IS : 4885 |
102 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard designInside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 |
103 | (i) For Sewer Line |
104 | Extra for depth of man hole size 90x80 cm |
105 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
106 | FORRAIN WATER HARVESTING WORKS |
107 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
108 | In all kind of soil upto 1.5m depth |
109 | In all kind of soil upto 1.5m to 3.0m. depth |
110 | In all kind of soil upto 3.0m to 4.5m. depth |
111 | Providing and laying in position cement concrete of specified grade excluding the ccost of centering and shuttering -All work up to plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
112 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
113 | Reinforced cement concrete work inbeams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, intels, bands plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20mm nominal size) |
114 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tnsile steel bars. |
115 | 12 mm cement plaster on rough side of single or half brick wall mix 1:4 (1 cement : 4 coarse sand) |
116 | Centring and shuttering including struting , proping etc and removal of form for : Suspended floors, roofs, landings, balconies and access platform. |
117 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design: With 20x20mm square bar |
118 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
119 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. |
120 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
121 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
122 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
123 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
124 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
125 | EXTERNAL PIPE NETWORK SYSTEM |
126 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
127 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 250mm diameter |
128 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 250 mm.dia. RCCPipes |
129 | SEPTIC TANK WITH SOAK PIT |
130 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). |
131 | From 0.00 mt to 1.50 mt |
132 | 1.50mt to 3.0 mt |
133 | 3.0 mt to 4.50 mt |
134 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
135 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. As in item no. 3above but for slabs (Using 1:1.5:3 Mix concrete) |
136 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
137 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
138 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
139 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 Coarse sand |
140 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
141 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
142 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
143 | FIRE FIGHTING SYSTEM(INTERNAL HYDRANT SYSTEM) |
144 | Supplying, Installation, Testing & Commissioning ofElectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) |
145 | (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. |
146 | (b) Suitable HP Squirrel cage indution motor, TEFC type synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, confirming to IS-325. |
147 | (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
148 | (d) Suitable cement concrete foundation duly plastered with anti vibration pads. 450 lpm at 35 m head |
149 | Providing, laying, testing & Commissioning of"B" class heavy duty MS pipe confirming to IS 1239 including welding, fittings like elbows,tee, flanges,tapers,nut bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 100 mm dia |
150 | Supplying & fixing single headed internal yard hydrant valve with instantaneousGunmetal/Stainless Steel coupling of63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal |
151 | Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia |
152 | Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia |
153 | Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required: |
154 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal |
155 | Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. |
156 | 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 |
157 | 20 mm nominal internal dia gun metal globe valve & nozzle. |
158 | Drum and brackets for fixing the equipments on wall. |
159 | Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m |
160 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal |
161 | Providing & fixing of pressure switch in M.S. pipe line including connection etc as required. |
162 | Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
163 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018 |
164 | Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018 |
165 | Fire man axe.Make :- Rcube Fire Protection Services Pvt. Ltd. /R.K. Engineers Services. CE Certified,ISO 13485:2016 & OHSAS 18001:2007 Approved. |
166 | Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete.Make : Standard Make |
167 | Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprisingof : a) 40 amp 3 Pole MCCB, 50Hz with breaking capacity 10KW. b)One Volt meter (0-500 V) with selector switch. c) One set including lamps. Make :- Rcube Fire Protection Services Pvt. Ltd. /R.K. Engineers Services. CE Certified,ISO 13485:2016 & OHSAS 18001:2007 Approved. |
168 | FIRE ALARM SYSTEM |
169 | Supplying, installation, testing & commissioning of Manual call Boxes of MS constuction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
170 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box(16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. |
171 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone cenclosed in a M.S. box(16 SWG)/ABS box with break glass in front etc. complete as required. |
172 | Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
173 | Supplying & laying 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
174 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilityes as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 6 Zone |
175 | FIRE FIGHTING SYSTEM(EXTERNAL) |
176 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
177 | Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal |
178 | Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia |
179 | Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia |
180 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal |
181 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal |
182 | Supplying & fixing ofFire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100 mm dia M.S. Pipe |
183 | Providing, laying, testing & Commissioning of"C" class heavy duty MS pipe confirming to IS 1239/3589 i/c fitting like elbows,tee,flanges,tapers,nut bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as support, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia |
184 | ELECTRICAL WORKS FOR INTERNAL |
185 | Wiring point for light with 1.5 sq.mm FR P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
186 | Wiring point for fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
187 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash |
188 | Wiring point for plug 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & socket etc, complete in all respect including matching colour wash. |
189 | Wiring point for call bellwith 1.5 sqmm.FRLSH PVC insulated multistrand single core copper condutor cable in PVC conduitpipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sq. mm. FR PVC insulated multistrand copper earth contunity wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting complete withmodular type bell push or 2 pin socket etc complete in all respects including matching color wash |
190 | Supplyfixingand concealing of25mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. ( T.V. /Telephone) |
191 | Supply & wiring of submains with two number2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
192 | Supply & wiring of submains with two number4 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
193 | Supply and wiring of submain with 4 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 4 sq. mm FRLSH PVC insulated multistrand copper earth contunity wire drawn inside the conduitcomplete in all respect. |
194 | Supply and wiring of submain with 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in32 mm dia heavy duty (2mm thick ) PVC conduitpartly concealed in wall and partly laid in slab along with reinforcement befor concreting with two number 10 SWG copper earth contunity wire including colour wash etc. complete in all respects. |
195 | Supply & fixing of single wall bracketon matching M.D.F.E.G.boardbase etc. complete in all required. Cat. A |
196 | Supply & fixing of Recess mounting round 15 to 18Watt LED down lighter having powder coated die cast aluminium housing with heat sink, diffuser/reflecter, and driver set complete in all respect.Cat. AAA |
197 | Supply & fixing of Recess/surface mounting round 24 watt to 32 wattLED down lighter having powder coated die cast aluminium housing with extended heat sink, diffuser/Reflecter, and driver set complete in all respect. Cat. AAA |
198 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. 1 X 22 W CAT-AAA |
199 | Supply and Fixing of Pendent mounting having 1"X4" size 36 to 46 Wattseamlessly interateds LED luminiew with acrylic sheet diffuser and intergral electronic driver complete in all respects.CAT-AAA |
200 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200mm sweep |
201 | Supply and Fixing ofservice bracket of 50mm. Dia 4 meter long fabricated from class ""B"" G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete in all respects. |
202 | Supply and fixing of factory wired integral LED flood light fitting having diecast aluminium housing built with driver set suitable for 140 to 150 watt confirming to IP 66 protection complete in all respect. CAT-AAA |
203 | Supply & fixing of Call Bell Of Approved Make on matching polishedMDFEG boardbrassincludingconnectionetc. as required. |
204 | Supplyand burying safe earthing Electorde T-19 (HotDip Galvanized), Length 2000 mm, outer pipe 50mm, inner pipe 25,terminal Dia 12mm ,outer G.I.pipe of 16 swg and inner GI pipe of 12swg withHotDipGavanized up to 100 mirconfilled with crystalline conducative mixture (CCM) having anti corrosive & conducative property with 50 kgs activated soil (BFC) capable ofreducing the soilresistivitywith good mixture ofretaning capacity along with 30 cm squre C.I. frame with hinged cover & masonryhousing (from electode terminaltoswitchboard , cost of 25 x 3 G.I. strip will be extra) Make:As approved in U.P.P.W.D. & C.P.R.I. Certified |
205 | Supplying & Laying of 32mm x 6mm Copper Stripfrom earth electrode in ground as required complete in all respects. |
206 | Supplying & Laying of 25mmx3mm G.I. Strip from earth electrode in ground as required complete in all respects. |
207 | Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects. |
208 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve 6 - 32 amps.Cat. A |
209 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA) CAT A |
210 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) CAT A |
211 | Supply and fixing of surface/ flush mounting 6 way TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site by Engineer Incharge. CAT A |
212 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape,etc. complete in allrespects. |
213 | Supply and fixing of single pole MCB blanking plate CAT A |
214 | Supply and fixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box including supply of all material, labour T & P etc required for proper completion of work. |
215 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
216 | Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. |
217 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properlyetc. complete as required. |
218 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
219 | Supplyfixingofelectronic fan regulator (Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
220 | CABLES |
221 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
222 | 10 sqmm 2 core |
223 | 10 sqmm 4 core |
224 | 95 sqmm 3.5 core |
225 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB’s (Four Pole 36 KA with thermal magnatic release) Switches complete and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F, KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB’s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. The minimum clearances between bus bars shall be as follows : |
226 | Phase to phase - minimum 20mm |
227 | Phase to neutral-minimum 15mm |
228 | CUBICAL PANEL BOARD ( MCCB TYPE ) |
229 | L.T.PANEL |
230 | Incoming : |
231 | one (1)No.400Amp. MCCB-1No. |
232 | Metering : |
233 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
234 | One (1) No. (0-400A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
235 | One (1) Set of Phase Indication Lamp. |
236 | Bus Bar : |
237 | One (1) No.400 A, TPN aluminimum bus bar of suitable length. |
238 | Outgoing : |
239 | Phase indication lamps on each outgoing to be provided. |
240 | 200 Amp. MCCB- 2 No. |
241 | 100 Amp. MCCB- 1 No. |
242 | 63 Amp. MCCB- 1 No. |
243 | OR outgoing as per site requirment(AS/SLD) |
244 | Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules. |
245 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. |
246 | Supply and fixing 400 AMPfour pole Moulded case type on load change over switch with enclosure(also suitable for panel mounting with extra cost of bus bar) including the cost of labour, T & P , painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.- |
247 | PART (B): SCHEDULE ITEMS (AS PER DSR. E&M 2018) |
248 | Supplying and drawing following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair. |
249 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet |
250 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75mm X 75 mm X 60mm Deep |
251 | Supplying and fixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm) |
252 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
253 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
254 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required.100 mm Dia |
255 | Point wiring for SP MCB controlled light points with 2 x 1.5 sq.mm FR PVC insulated stranded copper conductor wire in surface / recessed medium class PVC conduit, along with 1 No. 1.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
256 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
257 | PART C - NON - SCHEDULED ITEMS (AS PER MARKET RATES ) |
258 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX 300mm sweep. |
259 | Supply & erection of AC 230/250 Volts, 50 Hz 900 rpm exhaust fans including nuts, bolts, mounting frame and other accessories with connections etc. complete as required. Make: USHA Turbo Heavy Duty 450mm sweep. |
260 | Supply of AC 230/250 Volts, 50 Hz 55 w 1280 rpm Wall Fan including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required. (a) 400 mm sweep.-Make: USHA Cat No. MIST AIR ULTRA |
261 | EXTERNAL ELECTRICAL WORK |
262 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
263 | 95 sqmm 3.5 core |
264 | 10 sqmm 4.0 core |
265 | 10 sqmm 2.0 core |
266 | 6 sqmm 2.0 core |
267 | Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served sheathed, under ground cable including rubber ring etc. complete in all respects, the armouring of the cable shall be properly connected with earth as per direction of Engineer-in-charge. |
268 | 120 sqmm 3.5 core |
269 | 95 sqmm 3.5 core |
270 | 10 sqmm 4.0 core |
271 | 10 sqmm 2.0 core |
272 | 6 sqmm 2.0 core |
273 | Supply and fixing of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape, and making connections etc. complete in all respects as per directions of the Engineer-in-charge. |
274 | 95 Sq.mm |
275 | 10 sqmm. |
276 | 6 sqmm. |
277 | Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. |
278 | Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. |
279 | Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects. |
280 | Supply and erection of steel tubular pole 7.5 meters long designated 410 SP-6 in 1:3:6 cement concrete foundation including excavation, back filling etc. complete in all respects. |
281 | Supply and Fixing ofservice bracket of 50mm. Dia 4 meter long fabricated from class ""B"" G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete in all respects. |
282 | Supply and fixing of LED street light fitting having diecast aluminium body and diffuser/reflector with driver set suitable for 75 watt to 90 Watt confirming to IP 65 protection complete in all respect.CAT AAA |
283 | Painting of the pole with 2 coats of aluminium paint over red oxide primer complete in all respects. |
284 | Supply & wiring of submains with two number2.5 sq.mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in 20mm dia heavy duty (2mm thick)PVC conduit with 1 Number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand copper conductor cable as earth continuity wire drawn inside the conduitcomplete in all respect. |
285 | Supply fixingand concealing of32mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of the work as per directions and to the satisfaction of engineer in charge. ( For Incoming Cable ) |
286 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect. |
287 | EXTERNAL PLUMBING WORKS |
288 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
289 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. 250mm diameter |
290 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 250 mm.dia. RCCPipes |
291 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
292 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).With FPS bricks of class designation 75 |
293 | (i) For Sewer Line |
294 | Extra for depth of man hole size 90x80 cm |
295 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
296 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250mm diameter |
297 | EXTERNAL WATER SUPPLY SYSTEM -II |
298 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. not exceeding 80mm dia. |
299 | Provding and fixing gun metal non return valve of approved quality (screwed end) 65 mm nominal bore a) Horizontal |
300 | Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) |
301 | 65mm nominal bore. |
302 | 50mm nominal bore. |
303 | 32mm nominal bore. |
304 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. |
305 | 65mm diameter pipe |
306 | 50 mm diameter pipe |
307 | 32 mm diameter pipe |
308 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
309 | 65 mm nominal bore |
310 | 50 mm nominal bore |
311 | 32 mm nominal bore |
312 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for stop cock, withC.I. surface box 100x100x75mm(inside) with hinged cover fixed in cement concrete slab1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks |
313 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
314 | 25 to 40 mm dia nominal bore |
315 | 50 to 80 mm dia nominal bore |
316 | 6.0 MTR. WIDE M.S. GATE |
317 | Earth workinexacavationin trenches forfoundationsand for pipes cables etc. in ordinary soil(loam clay or sand)including liftupto1.5 m and dressing ofsidesandrammingofbottom sand disposal ofsurplusexcavated earth as directed by the Engineer i/c withina lead of 50m. |
318 | Providing and layingin cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost ofform-work,in foundation and floors. |
319 | R.c.c. workwith cement approved coarse sandand2cm. (3/4") guageapproved stoneballastin the proportion 1:1.5:3 in BEAM and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire andincludingnecessary centering and shuttering etc.and also including supply of all materials,labour andtoolsand plants etc,required for proper completion of the works.strength of the concrete shall not be less than M-150. |
320 | As in item 3 above but in R.C.C. columns in (Using 1:2:4 Mix concrete). |
321 | R.c.c. workwith cement approved coarse sandand2cm. (3/4") guageapproved stoneballastin the proportion 1:1.5:3 in foundation |
322 | Boringproviding& installing cast-in-situsingle under reamed pileof specified diaand length below pile cap in cement concrete with mix M-20 of 20mm nominal size of grit to size to carry a safe working load not less than specified excluding the cost of steel reinforcement butincluding boringwithpentonide solution and length ofpile to embedded in the pile cap. 300 mm dia Piles (P1) |
323 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. |
324 | Finishingwallswith water-proofing on cementpaint of approvedmakesuch as super snowcem,durrocem,robiacem,guttucem supercem qualityandof required shade on undecorated wall surfaces(two coat) overone andincludingonecoatwhite after thoroughly brushing the surface to powdered materialsincluding curing and cost of all materials. |
325 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
326 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
327 | Cattle Catcher (6.00x1.48 M Size) |
328 | Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50m and lead upto 30m. and including filling, watering and ramming of excavated earth in to the space between the building and side of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by engineer in charge. As per S.I. No. 251 |
329 | Concrete with 40mm gauge Stone ballast, chopan sand of and cement in the proportion of 8:4:1 including supply of all materials labour and tools and plants etc. required for proper completion of work. S.I. No. 281 |
330 | Cement concrete with 20mm gauge dalla stone aggregate approved chopan coarse sand and cement in the proportion of 4:2:1 in hold fast including supply of all materials, labour and tools and plants etc. required for proper completion of work. As per 279(ii) |
331 | Mild steel or iron work in heavy sizes such as trusses, built up gates, record racks, roof work, gates etc. wrought to required form, including drilling holes riverting or welding where necessary & their fixing, required for proper completion of the work. As per s.i.no. 503 Angle iron 90x90x6 mm T-Section 90x90x6 Hold Fast 40x6 Flat |
332 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. D.S.R. 18.12.8*0.8345 80 mm dia nominal bore |
333 | DRAIN 300X450 |
334 | Earth work in excavation |
335 | P.C.C. 1:4:8 |
336 | B/W in 1:4 Cement Coarse Sand |
337 | 12 MM thick plaster (1:3) coarse sand |
338 | Interlocking |
339 | COST OF INTERLOCKING |
340 | KERB STONE |
341 | KERB STONE ALONG WITH INTERLOCKING |
342 | EARTH FILLING |
343 | COST OF EARTH FILLING IN THE CAMPUS |
344 | Boundary Wall |
345 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
346 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
347 | GST Extra as per Applicable |