| 1 | PHASE II -PART-1 TRANSFORMER INSTALLATION- od20626/2020_2021/IASupply and erection of four pole structure consisting of 4 nos 10 mtrs long 175x85 RSJ poles and fixing the pole including excavation of trench and providing PCC of 1:3:6 mm of 40mm metal at bottom andRCC 1:2:4 of 20 mm metal at top with size 600x6000x1980 mm and neatly plaster over the earth portion of plint and neatly painted the pole with 2 coat epoxy paint over a coat of primer as required etc. complete, as per the direction of departmental officers at site. |
| 2 | od45203/2019_2020/IASupply and fixing of channel iron 100mm X 50 mm X 6 mm (9.56 kg per metre) for placing and fixing CTPT unit / ABS/ Lightning arrestor using suitable size bolt and nuts , painting with zinc chromate primerand 2 coat aluminium paint as per directions of departmental officers at site. |
| 3 | 13.1 Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mmdia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stayclamps, turnbuckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulatoretc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mmnominal size ) foundationincluding excavation and refilling etc. as required as per directions of departmental officers at site. |
| 4 | od20411/2020_2021/IASupply and fixing of wall fencing to the transformer yard with appropriate area including(50mmx50mmx6mm size) angle iron support in all leg fixed with concrete base and(35mmx35mmx5)angle iron frame in the outer frame area of the each side of the fencing and(25mmx25mmx3mmsize) angle iron support in each side more than 1.2 meter interval and one door provided in the front side of the yard with the same material,and all side of the fencing covered with weldiron net mesh with supported by 25*3 flat iron. All the structures are welded and fabricated using suitable nut and bolt , and painted 2 coats of epoxy paint over a coat of primer as required.The bottom of thefencing shall be 150 mm for which brick work 225 mm thick shall be around the fencing including plastering as required as per directions of departmental officers at site. |
| 5 | 13.10 Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required as per directions of departmental officers at site. |
| 6 | 13.11 Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. as per directions of departmental officers at site. |
| 7 | od45204/2019_2020/IASupply and providing 11KV 600/800 A AB switch with handle set fixed on the existing MS channel frame work as per directions of departmental officers at site. |
| 8 | 13.13 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire. 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KSA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required as per directions of departmental officers at site. |
| 9 | 90.16.1.8 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required8.00 mm copper conductor (0 SWG) as per directions of departmental officers at site. |
| 10 | 90.16.5.8 Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.8 mm (0 SWG) as per directions of departmental officers at site. |
| 11 | od20392/2020_2021/IASupply and providing the following sizes of bolt and nut with washers on the existing MS box , earthbus,earthing system etc. as required including drilling necessary holes as required - 25 x 6 mm brass bolt& nut |
| 12 | od45209/2019_2020/IASupply and fixing 11KV DO (drop out) fuse unit with fuse element with iron base insulators on the existing MS channel frame work as per directions of departmental officers at site. |
| 13 | od20400/2020_2021/IAsupply and spreading 40mm hard granite broken stone in transformer yard etc complete as per directions of departmental officers at site. |
| 14 | od20401/2020_2021/IA Supply and spreading of fine sand in transfoiormer yardetc complete as per directions of departmental officers at site. |
| 15 | od45770/2020_2021/IASupply,conveyance, installation, testing and commissioning of 250 K.V.A out door oil type transformer,transformer Portion consists of 250 K.V.A , 11000V/433V, 50 Hz, Delta/Star connected ,insulated copper wound oil filled ,natural cooled transformer out door minimum IP 65/66 Protection, Bushing on HT side,cable box with provision of terminating suitable AYFY cable on LT side,The core shall be made of laser scribed core Class \"F\" insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achieve tap position +-5% in steps of 2.5% with all standard fittings etc complete as per directions of departmental officers at site. |
| 16 | od41792/2019_2020/IAFabrication of stand for KSEB meter box using angle iron/channel etc fix it on earth etc complete as per directions of departmental officers at site. |
| 17 | od45231/2019_2020/IASupply and installation of dust and vermin proof wall mounting , sintex make meter box of size 700X480X210 mm GSMB 7450 ( IP65 ) or equivalent suitable for fixing KSEB meter,fuse units,CT etchinged door construction ,double door,for the front side with compartments if necessary,providing vision panel for the meter compartment knock out for cable entry as required including fixing it ,making good the damages etc. as required as per directions of departmental officers at site. |
| 18 | od41794/2019_2020/IASupply conveyance ,installation testing and commissioning of -/5A, class 0.2S, 11KV/110V 4 wire HT TOD meter with terminal block , fuses including Wiring of ToD meter etc. as required as per directions of departmental officers at site. |
| 19 | od18021/2020_2021/IASupply, installation , testing and commissioning of 11kV Outdoor type CT-PT Unit,3 Phase 4 wire system of metering with 3 No of CTs of accuracy class 0.2S, CT ratio 10 or 15 or 20/5 as per KSEBLSpecifications S and 3Ph.PT of 0.2 Accuracy class ;Voltage Ratio :11kV/110V, as per KSEBL Specifications and with required amount of transformer oil INDUS make or euivalent etc. as required as per directions of departmental officers at site. |
| 20 | od41796/2019_2020/IASupply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper control cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps notexceeding 60cms, making good the damages , colour washing etc. as required. 12 core 2.5 sq mm with factory made clamp etc. as required as per directions of departmental officers at site. |
| 21 | 1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm etc. as required as per directions of departmental officers at site. |
| 22 | od44120/2019_2020/IASupply and providing plate earthing with 1200x1200x12 mm GI/CI earth plate, 50mm GI watering pipe, GI funnel with weld mesh, 25 x 3mm GI clamps, charcoal etc., including providing brick work masonryenclosure at the top (450 x 450 x 450 mm inside) with Gully trap with covering box in CI (450x450x10mm) but excluding earth continuity conductor, test joint etc. as required as per directions of departmental officers at site. |
| 23 | od44121/2019_2020/IASupply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate using test joint using suitable size nut and bolt etc as required.32 x 6 mm GI strip etc. as required as per directions of departmental officers at site. |
| 24 | od44122/2019_2020/IAProviding and fixing testing joint made of 2 no. strips as mentioned below of Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending toshape, drilling necessary holes and fixed to the watering pipe etc using suitable size nut and bolts as required.2*32*6 GI strip etc. as required as per directions of departmental officers at site. |
| 25 | 90.16.3.5 Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 6 mm GI strip as per directions of departmental officers at site. |
| 26 | od20423/2020_2021/IA Supplying , threading , laying and jointing of the following sizes of \"B\" class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads. 40 mm dia etc complete as per directions of departmental officers at site. |
| 27 | od44130/2019_2020/IASupplying and laying 32mm X 6 mm GI strip at 0.60 meter below ground as strip earth electrode, including connection/ terminating with suitable nut, bolt, spring, washer etc. as required as per directions of departmental officers at site. |
| 28 | 90.16.4.5 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 6 mm GI strip etc complete as per directions of departmental officers at site. |
| 29 | od45216/2019_2020/IA Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength near panel/substation etc complete as per directions of departmental officers at site. |
| 30 | od27548/2019_2020/IA Supply of fuse puller up to 630 Amps etc complete as per directions of departmental officers at site. |
| 31 | od44135/2019_2020/IA Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of redoxide and written with white paint \"FIRE\" mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. asrequired as per directions of departmental officers at site. |
| 32 | od44137/2019_2020/IA Supply of LT grade rubber gloves etc complete as per directions of departmental officers at site. |
| 33 | od20627/2020_2021/IA Supply and providng 11 KV rubber hand long glove etc complete as per directions of departmental officers at site. |
| 34 | od44139/2019_2020/IA supply of 180 mm Neon Tester Taparia make or equivalent etc complete as per directions of departmental officers at site. |
| 35 | od44140/2019_2020/IA supply of 250 mm black tip 2 in 1 screw driver Taparia make or equivalent etc complete as per directions of departmental officers at site. |
| 36 | od44144/2019_2020/IA supply of Adjustable spanner 305 mm Taparia make or equivalent etc complete as per directions of departmental officers at site. |
| 37 | od45771/2020_2021/IA Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision. etc complete as per directions of departmental officers at site. |
| 38 | od45772/2020_2021/IA Additional copies of the scheme in A3 size etc complete as per directions of departmental officers at site. |
| 39 | od45773/2020_2021/IA Charges for preparation of scheme for the Electrical Installation for sheet of A3 size etc complete as per directions of departmental officers at site. |
| 40 | od45774/2020_2021/IA Supply and providing Neutral CT for up to 500 kva transformer etc complete as per directions of departmental officers at site. |
| 41 | od45775/2020_2021/IA Supply and fixing earth fault relay Land T MC 12 or equivalent etc complete as per directions of departmental officers at site. |
| 42 | od45776/2020_2021/IA Supply and providing 4 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps includingfixing it to wall as requiredas per directions of departmental officers at site. |
| 43 | 7.10Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground asrequired etc complete as per directions of departmental officers at site. |
| 44 | POWER WIRING AND PANEL BOARD - 90.12.7.34Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clampsnot exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 185 sq mm etc complete as per directions of departmental officers at site. |
| 45 | 90.12.5.34 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 185 sq mm etc complete as per directions of departmental officers at site. |
| 46 | 90.12.10.5 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 90/75 mm or nearest size etc complete as per directions of departmental officers at site. |
| 47 | 9.1.27 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.3 1/2X 185 sq. mm (57mm) etc complete as per directions of departmental officers at site. |
| 48 | 90.12.5.3 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm etc complete as per directions of departmental officers at site. |
| 49 | 90.12.7.3Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp etc complete as per directions of departmental officers at site. |
| 50 | 9.1.2 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.2 X 10 sq. mm (19mm) etc complete as per directions of departmental officers at site. |
| 51 | od20625/2020_2021/IA Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length andother dimensions noted along with each size of glands for the following sizes of cables as required.(4 sq - 16sq mm with 12 mm wide x 1.20 mm thick clip) etc complete as per directions of departmental officers at site. |
| 52 | od45218/2019_2020/IA Supplying and providing earth clamps made out of copper strips of the following sizes including cutting and bending the flat exactly to the shape of the gland, drilling necessary holes for nut & bolt, tinningthe points of contacts and giving connections to the main earthing system as required. (20 x 3 mm for earthing glands of size 120 sq mm to 185 sq mm)etc complete as per directions of departmental officers at site. |
| 53 | od44156/2019_2020/IA Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable traysmade out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good thedamages, colour washing etc as required as per directions of departmental officers at site. |
| 54 | od44157/2019_2020/IA Supplying and installation of supports, anchor bolts etc made out of suitable size single section channeletc as required including painting with 2 coats of synthetic enamel paint etc complete as per directions of departmental officers at site. |
| 55 | od20424/2020_2021/IA Fabrication, supply, conveyance and fixing frame work made out of suitable size angle iron cut andwelded to shape of suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gear, fixed to wall using suitable size anchor bolts or grouted to wall, making good the damages, colour washing etc as requiredas per directions of departmental officers at site. |
| 56 | od45312/2019_2020/IA Fabrication, supply, conveyance and fixing cable entry/ wire way box made out 1.60 mm CRCA sheet ofsuitable size to match the switch gear and enabling the cables to be connected without strain, painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes and mounting to the switch gear etc as required as per directions of departmental officers at site. |
| 57 | 90.14.1.1 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using2.00mm CRCA sheet, powder coated (excluding base frame) etc complete as per directions of departmental officers at site. |
| 58 | od44167/2019_2020/IA Carrying out control wiring for panel with normal meters and indication lamps for interconnecting thecontrol devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of thewiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.-1.50 sq mm single run with required sockets etc complete as per directions of departmental officers at site. |
| 59 | od44168/2019_2020/IA Carrying out control wiring for panel with normal meters and indication lamps for interconnecting thecontrol devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of thewiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.2.50 sq mm single run with required sockets etc complete as per directions of departmental officers at site. |
| 60 | 90.14.2.1 Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc complete as per directions of departmental officers at site. |
| 61 | 90.14.3.1 Supply and providing heavy duty \"A\" section neoprene gasket in the panel boardA\" section neoprene beeding suitable for 1.60/ 2.00 mm sheet etc complete as per directions of departmental officers at site. |
| 62 | 90.14.4 Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) etc complete as per directions of departmental officers at site. |
| 63 | 90.14.6 Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required as per directions of departmental officers at site. |
| 64 | 90.14.7 Supply and providing copper earth bus in the panel board etc complete as per directions of departmental officers at site. |
| 65 | 90.14.10.17 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC etc complete as per directions of departmental officers at site. |
| 66 | od45777/2020_2021/IA Supply and fixing of Spreader/ terminal adapter kit with shroud in the existing microprocessor based 4pole MCCB of rating up to 400 TO 630 A(8 pieces) etc complete as per directions of departmental officers at site. |
| 67 | 90.14.11.3 MCCB Accessories Supply and fixing one number earth fault Relay up to 250A to 400A with CBCT etc complete as per directions of departmental officers at site. |
| 68 | 90.14.11.12 MCCB Accessories Supply and fixing shunt release for all voltage range up to 630A etc complete as per directions of departmental officers at site. |
| 69 | 90.14.11.15 MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with doorinterlock ) in the existing MCCB of rating up to 315-630 A etc complete as per directions of departmental officers at site. |
| 70 | 90.14.11.11 MCCB AccessoriesSupply and fixing one number under voltage release for all voltage range up to 630A MCCB etc complete as per directions of departmental officers at site. |
| 71 | 2.1.3 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel boardwith ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N etc complete as per directions of departmental officers at site. |
| 72 | 2.1.5 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.160 Amp TP&N etc complete as per directions of departmental officers at site. |
| 73 | od20439/2020_2021/IA supply and installation HRC Fuse holder with bolted type fuse link 20 amps etc complete as per directions of departmental officers at site. |
| 74 | od44172/2019_2020/IA CURRENT TRANSFORMER -120/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT etc complete as per directions of departmental officers at site. |
| 75 | od44176/2019_2020/IA CURRENT TRANSFORMER -250/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT etc complete as per directions of departmental officers at site. |
| 76 | od44174/2019_2020/IA Supply,fixing and installation of Three Phase Ammeter accuracy class 1-digital type etc complete as per directions of departmental officers at site. |
| 77 | od44175/2019_2020/IA Supply,fixing and installation of Three Phase Voltmeter accuracy class 1-Digital type etc complete as per directions of departmental officers at site. |
| 78 | od44181/2019_2020/IA S/F Cable alley, 100 x 40 mm aluminium anodised legend plates etc complete as per directions of departmental officers at site. |
| 79 | od44182/2019_2020/IA S/F Bus bar chamber, 100 x 40 mm aluminium anodised legend plates etc complete as per directions of departmental officers at site. |
| 80 | od44183/2019_2020/IA Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English andMalayalam) and conventional Skull and Bone in Red colour etc complete as per directions of departmental officers at site. |
| 81 | od45778/2020_2021/IA Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panelboard etc as required in Panel board/DB\"s- 2.50 cm, 4 cm or 5 cm height etc complete as per directions of departmental officers at site. |
| 82 | od45779/2020_2021/IA Supply and providing LED indicators for all voltage ranges - Blue Colour etc complete as per directions of departmental officers at site. |
| 83 | od45780/2020_2021/IA Supply and providing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour etc complete as per directions of departmental officers at site. |
| 84 | Motor connection - od20444/2020_2021/IA Providing and fixing following capacity switch disconnector unit in sheet enclosure, making connections, etc. as required. 160 amps 3 pole etc complete as per directions of departmental officers at site. |
| 85 | od20445/2020_2021/IA Providing and fixing following capacity switch disconnector unit in sheet enclosure, making connections,etc. as required. 25/32 amps 3 pole etc complete as per directions of departmental officers at site. |
| 86 | od45781/2020_2021/IA supply and installation of capacitor duty contactors 3Pole for 20 kvar with necessary electricalconnection(2 NO/NC included) etc complete as per directions of departmental officers at site. |
| 87 | od45312/2019_2020/IA Fabrication, supply, conveyance and fixing cable entry/ wire way box made out 1.60 mm CRCA sheet ofsuitable size to match the switch gear and enabling the cables to be connected without strain, painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes and mounting to the switch gear etc as required as per directions of departmental officers at site. |
| 88 | od13047/2019_2020/IA conveyance for motor pump set from section to site(vallachira) including loading and unloading etc complete as per directions of departmental officers at site. |
| 89 | od13049/2019_2020/IA conveyance stator rotor starter from section to site(vallachira) including loading and unloading etc complete as per directions of departmental officers at site. |
| 90 | od44193/2019_2020/IA Fabrication supply and installation of foundation bolt wit nuts of 25mm thickness for new foundation etc complete as per directions of departmental officers at site. |
| 91 | 90.14.28.2 S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor etc complete as per directions of departmental officers at site. |
| 92 | od20461/2020_2021/IA Supply & renewal of bearing No. NU 314 etc complete as per directions of departmental officers at site. |
| 93 | od20462/2020_2021/IA Supply & renewal of bearing No 6311/6311 C3 etc complete as per directions of departmental officers at site. |
| 94 | od45782/2020_2021/IA Supply, installation testing and commissioning of Vacuum pump Kirloskar DV-40 or equivalent 5 HP,1450 RPM,3 phase etc complete as per directions of departmental officers at site. |
| 95 | od20463/2020_2021/IA Supply, conveyance and filling of good quality LT grade transformer oil etc complete as per directions of departmental officers at site. |
| 96 | od44205/2019_2020/IA Supply and fitting 25 mm brass heavy duty half turn ball valve. etc complete as per directions of departmental officers at site. |
| 97 | od44206/2019_2020/IA Supply and providing 25 mm green flexible hose and giving connection etc complete as per directions of departmental officers at site. |
| 98 | od20482/2020_2021/IA Fabrication,Supply,conveyance and errecting 32 mm GI pipe with suitable specials such as coupler,union, bend, etc. and fixing on suction/delivery side of Vacuum pump set using shellack, rubber packing,bolt, nut and washer etc complete as per directions of departmental officers at site.. |
| 99 | od18022/2020_2021/IA Dismantling the 51-75 HP motor into stator and rotor, cleaning the windings attending minor repairs, retaping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning and greasing the bearings with good quality grease, heating the windings, reassembling, test runningincluding scrapping, cleaning and painting with enamel paint. etc complete as per directions of departmental officers at site. |
| 100 | od18023/2020_2021/IADismantling the 60 - 75 HP oil starters by parts draining out the oil, (in case of oil starters ) cleaning thetank, terminal contacts, cutting, leveling and polishing the contacts wherever necessary, checking the tripping mechanism, replacing the damaged wires, attending minor repairs, cleaning the oil,(in case of oilstarters ), refitting, resetting and making the starter in good working condition including scrapping, cleaning and painting with a coat of enamel paint etc complete as per directions of departmental officers at site. |
| 101 | od18024/2020_2021/IA Refitting the 60-75 HP motor on base plate, leveling and correcting alignment with the pump coupling thesame giving connection, testing and trail run on full load etc complete as per directions of departmental officers at site. |
| 102 | od20683/2020_2021/IA Leading the burnt motor power greater than 60 HP and up to 75 HP ( already dismantled) from pump house to the nearest road side, loading into the vehicle, including charges for loading and unloading etc complete as per directions of departmental officers at site. |
| 103 | od18025/2020_2021/IA Seperate the motor in to stator and rotor , remove the whole burnt stator coil by cutting, pulling andcleaning the slots.Insulating the slots by using nomex paper, rewinding the complete stator slots by using same gauge new copper super enameled winding wire and taping coils.Providing new lead wires,sockets etc.Varnishing the coil using best quality insulation varnish and baking the coils, reassembling and test run the motor.(Less the cost of scarp copper wire) etc complete as per directions of departmental officers at site. |
| 104 | od18026/2020_2021/IA Charges for rewinding the burnt rotor after dismantling the damaged rotor winding from the rotor slots,cleaning the slots neatly, insulating the slots with correct class of insulating paper, winding the rotor with good quality correct gauge of super enamelled copper winding wires, closing the rotor slots with fibre wedges, putting proper inter layer insulation, connecting the coil end connection, providing new rotor lead wire, steel binding the overhang with proper insulation at both ends, heating the coils and varnishing with good quality insulation varnish, keep it for drying etc complete as per directions of departmental officers at site. |
| 105 | od20684/2020_2021/IA Leading the rewound motor power greater than 60 HP and up to 75 HP from workshop to pump house,unloading and conveying to the base plate etc complete as per directions of departmental officers at site. |
| 106 | 90.14.24.17 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors etc complete as per directions of departmental officers at site. |
| 107 | 90.14.24.25 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly PropyleneCapacitor, Box Type, suitable for direct connection to motors etc complete as per directions of departmental officers at site. |
| 108 | od18027/2020_2021/IA Supply and fixing single phasing preventer (SM 301 GIC/ L&T or equivalnt )and giving connections as required etc complete as per directions of departmental officers at site. |
| 109 | 90.12.7.21 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 120 sq mm etc complete as per directions of departmental officers at site. |
| 110 | 9.1.14 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 120 sq. mm (45mm) etc complete as per directions of departmental officers at site. |
| 111 | od45218/2019_2020/IASupplying and providing earth clamps made out of copper strips of the following sizes including cutting and bending the flat exactly to the shape of the gland, drilling necessary holes for nut & bolt, tinning the points of contacts and giving connections to the main earthing system as required. (20 x 3 mm for earthing glands of size 120 sq mm to 185 sq mm) etc complete as per directions of departmental officers at site. |
| 112 | od18028/2020_2021/IA Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 70 sq mm 3 run etc complete as per directions of departmental officers at site. |
| 113 | od18029/2020_2021/IA Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductorcables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 25 sq mm 3 run etc complete as per directions of departmental officers at site. |
| 114 | 90.6.4.53 Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 3 Run etc complete as per directions of departmental officers at site. |
| 115 | 1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm etc complete as per directions of departmental officers at site. |
| 116 | 1.17.30 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm etc complete as per directions of departmental officers at site. |
| 117 | 90.12.24.1 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm etc complete as per directions of departmental officers at site. |
| 118 | 90.12.24.3 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm etc complete as per directions of departmental officers at site. |
| 119 | 90.12.24.4 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm etc complete as per directions of departmental officers at site. |
| 120 | 90.12.24.6 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.25 sq mm etc complete as per directions of departmental officers at site. |
| 121 | 90.12.24.9 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.70 sq mm etc complete as per directions of departmental officers at site. |
| 122 | 90.6.10.2 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm etc complete as per directions of departmental officers at site. |
| 123 | od44208/2019_2020/IA Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required 50 mm etc complete as per directions of departmental officers at site. |
| 124 | od45309/2019_2020/IA Supplying and clamping the following sizes of corrugated pvc flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages.20 mm diaetc complete as per directions of departmental officers at site. |
| 125 | od45310/2019_2020/IA Supplying and clamping the following sizes of corrugated pvc flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages.25 mm diaetc complete as per directions of departmental officers at site. |
| 126 | od45311/2019_2020/IA Supplying and clamping the following sizes of corrugated pvc flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages.50 mm dia etc complete as per directions of departmental officers at site. |
| 127 | 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as requiredas per directions of departmental officers at site. |
| 128 | 90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG) etc complete as per directions of departmental officers at site. |
| 129 | 90.16.1.7 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required7.10 mm copper conductor ( 2 SWG) etc complete as per directions of departmental officers at site. |
| 130 | 90.16.3.9 Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing ofclamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip etc complete as per directions of departmental officers at site. |
| 131 | od45225/2019_2020/IA Supplying and laying 25 mm X 3 mm GI strip at 0.60 meter below ground as strip earth electrode, includingconnection/ terminating with suitable nut, bolt, spring, washer etc. as required as per directions of departmental officers at site. |
| 132 | 90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) etc complete as per directions of departmental officers at site. |
| 133 | 90.16.5.7 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.7.10 mm (2 SWG) etc complete as per directions of departmental officers at site. |
| 134 | od20488/2020_2021/IA Supply and providing the following sizes of bolt and nut with washers on the existing MS box ,earthbus,earthing system etc. as required including drilling necessary holes as required - 25 x 3 mm brass bolt & nut |
| 135 | 14.10 Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement) etc complete as per directions of departmental officers at site. |
| 136 | Light wiring - 90.2.1.1 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point etc complete as per directions of departmental officers at site. |
| 137 | 90.2.1.6 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of lightpoints etc complete as per directions of departmental officers at site. |
| 138 | 90.2.1.3 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point etc complete as per directions of departmental officers at site. |
| 139 | 90.2.1.4 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point etc complete as per directions of departmental officers at site. |
| 140 | 90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required as per directions of departmental officers at site. |
| 141 | 90.4.5.4 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), 300mm down rod , 2 number canopies, shackele kit, Copper winding, 3 number blades and all remaining accessories including safety pin, nut bolts, washers suitablefor 230V/240V single phase AC supply etc. complete as required as per directions of departmental officers at site. |
| 142 | od45334/2019_2020/IA Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with 200 mm polished plastic shade and 7 W LED bulb including giving connection etc as requiredas per directions of departmental officers at site. |
| 143 | 90.3.20.3 Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit thefitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box typefixture etc complete as per directions of departmental officers at site. |
| 144 | 90.3.21.3 Supply & installation of light fittings on \"C/U\" shaped flat iron bracket Supply, conveyance, installation, testing andcommissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. \"C/U\" brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.as required.1200 mm 1X20W LED Lamp with box type fixture etc complete as per directions of departmental officers at site. |
| 145 | 90.3.18.2 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps etc complete as per directions of departmental officers at site. |
| 146 | 90.15.4.1Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) etc complete as per directions of departmental officers at site. |
| 147 | 90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as requiredas per directions of departmental officers at site. |
| 148 | od20661/2020_2021/IA Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in theexisting opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core roundcopper conductor flex wire conforming to relevant ISS. - 200mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C etc complete as per directions of departmental officers at site. |
| 149 | 1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm etc. as required as per directions of departmental officers at site. |
| 150 | 1.17.20 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm etc complete as per directions of departmental officers at site. |
| 151 | 90.6.10.1 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm etc complete as per directions of departmental officers at site. |
| 152 | 90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required2.00 mm copper conductor ( 14 SWG) etc complete as per directions of departmental officers at site. |
| 153 | 90.16.1.2 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required2.65 mm copper conductor (12 SWG) etc complete as per directions of departmental officers at site. |
| 154 | 90.16.5.1 Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.2.00 mm (14 SWG) etc complete as per directions of departmental officers at site. |
| 155 | 90.16.5.2 Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.2.65 mm (12 SWG) etc complete as per directions of departmental officers at site. |
| 156 | od20498/2020_2021/IA Supply and providing the following sizes of bolt and nut with washers on the existing MS box , earthbus,earthing system etc. as required including drilling necessary holes as required - 12 x 3mm etc complete as per directions of departmental officers at site. |
| 157 | 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modularswitch, connection etc. as required as per directions of departmental officers at site. |
| 158 | 2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door etc complete as per directions of departmental officers at site. |
| 159 | 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole etc complete as per directions of departmental officers at site. |
| 160 | 2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps etc complete as per directions of departmental officers at site. |
| 161 | 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DBcomplete with connections, testing and commissioning etc. asequired.40 amps etc complete as per directions of departmental officers at site. |
| 162 | PHASE -II - PART-1 TRANSFORMER INSTALLATION - od20628/2020_2021/IASupply and erection of four pole structure consisting of 4 nos 10 mtrs long 175x85 RSJ poles and fixing the pole including excavation of trench and providing PCC of 1:3:6 mm of 40mm metal at bottom andRCC 1:2:4 of 20 mm metal at top with size 600x6000x1980 mm and neatly plaster over the earth portion of plinth and neatly painted the pole with 2 coat epoxy paint over a coat of primer as required as per directions of departmental officers at site. |
| 163 | od45245/2019_2020/IA Supply and fixing of channel iron 100mm X 50 mm X 6 mm (9.56 kg per metre) for placing and fixing CTPT unit / ABS/ Lightning arrestor using suitable size bolt and nuts , painting with zinc chromate primer and 2 coat aluminium paint as per directions of departmental officers at site. |
| 164 | 13.1 Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mmdia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stayclamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulatoretc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mmnominal size ) foundation including excavation and refilling etc. as requiredas per directions of departmental officers at site. |
| 165 | od20629/2020_2021/IA supply and spreading 40mm hard granite broken stone in transformer yard etc complete as per directions of departmental officers at site. |
| 166 | od20630/2020_2021/IA supply and spreading of fine sand in transformer yard etc complete as per directions of departmental officers at site. |
| 167 | od20632/2020_2021/IA Supply and fixing of wall fencing to the transformer yard with appropriate area including(50mmx50mmx6mm size) angle iron support in all leg fixed with concrete base and(35mmx35mmx5)angle iron frame in the outer frame area of the each side of the fencing and (25mmx25mmx3mmsize) angle iron support in each side more than 1.2 meter interval and one doorprovided in the front side of the yard with the same material,and all side of the fencing covered with weld iron net mesh with supported by 25*3 flat iron. All the structures are welded and fabricated using suitable nut and bolt , and painted 2 coats of epoxy paint over a coat of primer as required.The bottom of the fencing shall be 150 mm for which brick work 225 mm thick shall be around the fencing including plastering as required as per directions of departmental officers at site. |
| 168 | 13.10 Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required as per directions of departmental officers at site. |
| 169 | 13.11 Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required as per directions of departmental officers at site. |
| 170 | 13.13 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire. 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KSA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as requiredas per directions of departmental officers at site. |
| 171 | 90.16.1.8 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required8.00 mm copper conductor (0 SWG) as per directions of departmental officers at site. |
| 172 | 90.16.5.8 Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.8 mm (0 SWG) as per directions of departmental officers at site. |
| 173 | od45246/2019_2020/IA Supply and providing 11KV 600/800 A AB switch with handle set fixed on the existing MS channel framework etc complete as per directions of departmental officers at site. |
| 174 | od45247/2019_2020/IA Supply and fixing 11KV DO (drop out) fuse unit with fuse element with iron base insulators on the existingMS channel frame work etc complete as per directions of departmental officers at site. |
| 175 | od20633/2020_2021/IA Supply,conveyance, installation, testing and commissioning of 200 K.V.A out door oil type transformer, transformer Portion consists of 200 K.V.A , 11000V/433V, 50 Hz, Delta/Star connected ,insulated copper wound oil filled ,natural cooledtransformer out door minimum IP 65/66 Protection, Bushing on HT side,cable box with provision of terminating suitable AYFY cable on LT side,The core shall be made of laser scribed core Class \"F\" insulation level shall be maintained. OFF load tap changing facility shall beincorporated so as to achieve tap position +-5% in steps of 2.5% with all standard fittings etc complete as per directions of departmental officers at site. |
| 176 | od45249/2019_2020/IA Fabrication of stand for KSEB meter box using angle iron/channel etc fix it on earth. etc complete as per directions of departmental officers at site. |
| 177 | od45268/2019_2020/IA Supply and installation of dust and vermin proof wall mounting , sintex make meter box of size 700X480X210 mm GSMB 7450 ( IP65 ) or equivalent suitable for fixing KSEB meter,fuse units,CT etc hinged door construction ,double door,for the front side with compartments if necessary,providing vision panel for the meter compartment knock out for cable entry as required including fixing it ,making good the damages etc. as required as per directions of departmental officers at site. |
| 178 | od45250/2019_2020/IA Supply conveyance ,installation testing and commissioning of -/5A, class 0.2S, 11KV/110V 4 wire HTTOD meter with terminal block , fuses including Wiring of ToD meter etc complete as per directions of departmental officers at site. |
| 179 | od20634/2020_2021/IA Supply, installation , testing and commissioning of 11kV Outdoor type CT-PT Unit,3 Phase 4 wire systemof metering with 3 No of CTs of accuracy class 0.2S, CT ratio 10 or 15 or 20/5 as per KSEBL Specifications S and 3Ph.PT of 0.2 Accuracy class ;Voltage Ratio :11kV/110V, as per KSEBL Specifications and with required amount of transformer oil INDUS make or euivalent etc complete as per directions of departmental officers at site. |
| 180 | od45252/2019_2020/IA Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper control cable,1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 12 core 2.5 sq mmwith factory made clamp etc complete as per directions of departmental officers at site. |
| 181 | 12.39 Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required as per directions of departmental officers at site. |
| 182 | 90.12.12.11 Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation175/147 mm or nearest size etc complete as per directions of departmental officers at site. |
| 183 | od45257/2019_2020/IA Supply and providing plate earthing with 1200x1200x12 mm GI/CI earth plate, 50mm GI watering pipe, GIfunnel with weld mesh, 25 x 3mm GI clamps, charcoal etc., including providing brick work masonry enclosure at the top (450 x 450 x 450 mm inside) with Gully trap with covering box in CI (450x450x10mm) but excluding earth continuity conductor, test joint etc complete as per directions of departmental officers at site. |
| 184 | od45258/2019_2020/IA Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate using test joint using suitable size nut and bolt etc as required.32 x 6 mm GI strip etc complete as per directions of departmental officers at site. |
| 185 | od45259/2019_2020/IA Providing and fixing testing joint made of 2 no. strips as mentioned below of Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc using suitable size nut and bolts as required.2*32*6 GI strip etc complete as per directions of departmental officers at site. |
| 186 | od45260/2019_2020/IA Supplying and laying 32mm X 6 mm GI strip at 0.60 meter below ground as strip earth electrode, includingonnection/ terminating with suitable nut, bolt, spring, washer etc. as required as per directions of departmental officers at site. |
| 187 | od20666/2020_2021/IA Supplying , threading , laying and jointing of the following sizes of \"B\" class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads. 40 mm dia etc complete as per directions of departmental officers at site. |
| 188 | 90.16.3.5 Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing ofclamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)32 x 6 mm GI strip etc complete as per directions of departmental officers at site. |
| 189 | 90.16.4.5 Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).32 x 6 mm GI strip etc complete as per directions of departmental officers at site. |
| 190 | od45261/2019_2020/IA Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength near panel/substation etc complete as per directions of departmental officers at site. |
| 191 | od45265/2019_2020/IA Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint \"FIRE\" mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required as per directions of departmental officers at site. |
| 192 | od45266/2019_2020/IA Supply of fuse puller up to 630 Amps etc complete as per directions of departmental officers at site. |
| 193 | od45269/2019_2020/IA Supply of LT grade rubber gloves etc complete as per directions of departmental officers at site. |
| 194 | od20667/2020_2021/IA Supply and providng 11 KV rubber hand long glove etc complete as per directions of departmental officers at site. |
| 195 | od20636/2020_2021/IA Supply and providing the following sizes of bolt and nut with washers on the existing MS box , earth bus,earthing system etc. as required including drilling necessary holes as required - 25 x 6 mm brass bolt & nut etc complete as per directions of departmental officers at site. |
| 196 | 1.17.11Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm etc complete as per directions of departmental officers at site. |
| 197 | od45783/2020_2021/IA Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision etc complete as per directions of departmental officers at site. |
| 198 | od45784/2020_2021/IA Additional copies of the scheme in A3 size etc complete as per directions of departmental officers at site. |
| 199 | od45785/2020_2021/IA Charges for preparation of scheme for the Electrical Installation for sheet of A3 size. etc complete as per directions of departmental officers at site. |
| 200 | od45786/2020_2021/IA Supply and providing Neutral CT for up to 500 kva transformer etc complete as per directions of departmental officers at site. |
| 201 | od45787/2020_2021/IA Supply and fixing earth fault relay Land T MC 12 or equivalent etc complete as per directions of departmental officers at site. |
| 202 | od45788/2020_2021/IA Supply and providing 4 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps includingfixing it to wall as required as per directions of departmental officers at site. |
| 203 | POWER WIRING AND PANEL BOARD - 90.12.7.36 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 300 sq mm etc complete as per directions of departmental officers at site. |
| 204 | 90.12.5.3 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm etc complete as per directions of departmental officers at site. |
| 205 | 90.12.5.36 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 300 sq mm etc complete as per directions of departmental officers at site. |
| 206 | 90.12.7.3 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp etc complete as per directions of departmental officers at site. |
| 207 | 9.1.30 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.3 1/2X 300 sq. mm (70mm) etc complete as per directions of departmental officers at site. |
| 208 | 9.1.2 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.2 X 10 sq. mm (19mm) etc complete as per directions of departmental officers at site. |
| 209 | od45271/2019_2020/IA Supplying and providing earth clamps made out of copper strips of the following sizes including cuttingand bending the flat exactly to the shape of the gland, drilling necessary holes for nut & bolt, tinning the points of contacts and giving connections to the main earthing system as required. (25 x 3 mm for earthing glands of size 240 sq mm to 300 sq mm) etc complete as per directions of departmental officers at site. |
| 210 | od20639/2020_2021/IA Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length andother dimensions noted along with each size of glands for the following sizes of cables as required.(4 sq - 16sq mm with 12 mm wide x 1.20 mm thick clip) etc complete as per directions of departmental officers at site. |
| 211 | od45272/2019_2020/IA Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable traysmade out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good thedamages, colour washing etc as required as per directions of departmental officers at site. |
| 212 | od45273/2019_2020/IA Supplying and installation of supports, anchor bolts etc made out of suitable size single section channeletc as required including painting with 2 coats of synthetic enamel paint etc complete as per directions of departmental officers at site. |
| 213 | 90.14.1.1 Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providingecessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly aftersubjecting to 7 tank process etc as required. CRCA sheet alone be used for thefabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using2.00mm CRCA sheet, powder coated (excluding base frame) etc complete as per directions of departmental officers at site. |
| 214 | 90.14.2.1 Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc complete as per directions of departmental officers at site. |
| 215 | 90.14.3.1 Supply and providing heavy duty \"A\" section neoprene gasket in the panel boardA\" section neoprene beeding suitable for 1.60/ 2.00 mm sheet etc complete as per directions of departmental officers at site. |
| 216 | 90.14.4 Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC) etc complete as per directions of departmental officers at site. |
| 217 | 90.14.6 Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required as per directions of departmental officers at site. |
| 218 | 90.14.7 Supply and providing copper earth bus in the panel board etc complete as per directions of departmental officers at site. |
| 219 | 90.14.10.17 Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly asrequired.320A/400A, 50/55 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC etc complete as per directions of departmental officers at site. |
| 220 | od45789/2020_2021/IA Supply and fixing of Spreader/ terminal adapter kit with shroud in the existing microprocessor based 4pole MCCB of rating up to 400 TO 630 A(8 pieces) etc complete as per directions of departmental officers at site. |
| 221 | 90.14.11.3 MCCB AccessoriesSupply and fixing one number earth fault Relay up to 250A to 400A with CBCT etc complete as per directions of departmental officers at site. |
| 222 | 90.14.11.12 MCCB AccessoriesSupply and fixing shunt release for all voltage range up to 630A etc complete as per directions of departmental officers at site. |
| 223 | 90.14.11.15 MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with doorinterlock ) in the existing MCCB of rating up to 315-630 A etc complete as per directions of departmental officers at site. |
| 224 | 90.14.11.11 MCCB AccessoriesSupply and fixing one number under voltage release for all voltage range up to 630A MCCB etc complete as per directions of departmental officers at site. |
| 225 | 2.1.3 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. asrequired.100 Amp TP&N etc complete as per directions of departmental officers at site. |
| 226 | 2.1.5 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. asrequired.160 Amp TP&N etc complete as per directions of departmental officers at site. |
| 227 | od45276/2019_2020/IA CURRENT TRANSFORMER -100/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT etc complete as per directions of departmental officers at site. |
| 228 | od45277/2019_2020/IA CURRENT TRANSFORMER -200/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT etc complete as per directions of departmental officers at site |
| 229 | od45278/2019_2020/IA Supply,fixing and installation of Three Phase Ammeter accuracy class 1-digital type etc complete as per directions of departmental officers at site. |
| 230 | od45279/2019_2020/IA Supply,fixing and installation of Three Phase Voltmeter accuracy class 1-Digital type etc complete as per directions of departmental officers at site. |
| 231 | od45280/2019_2020/IA S/F Cable alley, 100 x 40 mm aluminium anodised legend plates etc complete as per directions of departmental officers at site. |
| 232 | od45281/2019_2020/IA S/F Bus bar chamber, 100 x 40 mm aluminium anodised legend plates etc complete as per directions of departmental officers at site. |
| 233 | od45282/2019_2020/IA Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English andMalayalam) and conventional Skull and Bone in Red colour etc complete as per directions of departmental officers at site. |
| 234 | od20642/2020_2021/IA supply and installation HRC Fuse holder with bolted type fuse link 20 amps etc complete as per directions of departmental officers at site. |
| 235 | od45283/2019_2020/IA Carrying out control wiring for panel with normal meters and indication lamps for interconnecting thecontrol devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of thewiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.-1.50 sq mm single run with required sockets etc complete as per directions of departmental officers at site. |
| 236 | od45284/2019_2020/IA Carrying out control wiring for panel with normal meters and indication lamps for interconnecting thecontrol devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of thewiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.2.50 sq mm single run with required sockets etc complete as per directions of departmental officers at site. |
| 237 | od45286/2019_2020/IA supply of 180 mm Neon Tester Taparia make or equivalent etc complete as per directions of departmental officers at site. |
| 238 | od45287/2019_2020/IA supply of 250 mm black tip 2 in 1 screw driver Taparia make or equivalent etc complete as per directions of departmental officers at site. |
| 239 | od45291/2019_2020/IA supply of Adjustable spanner 305 mm Taparia make or equivalent etc complete as per directions of departmental officers at site. |
| 240 | od45790/2020_2021/IA Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panelboard etc as required in Panel board/DB\"s- 2.50 cm, 4 cm or 5 cm height etc complete as per directions of departmental officers at site. |
| 241 | od45791/2020_2021/IA Supply and providing LED indicators for all voltage ranges - Blue Colour etc complete as per directions of departmental officers at site. |
| 242 | od45792/2020_2021/IA Supply and providing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour etc complete as per directions of departmental officers at site. |
| 243 | 7.10 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground asrequired etc complete as per directions of departmental officers at site. |
| 244 | Motor connection - od14928/2019_2020/IA Providing and fixing following capacity switch disconnector unit in sheet enclosure, making connections, etc. as required. 25 /32 amps 3 pole etc complete as per directions of departmental officers at site. |
| 245 | od20643/2020_2021/IA Providing and fixing following capacity switch disconnector unit in sheet enclosure, making connections, etc. as required. 160 amps 3 pole etc complete as per directions of departmental officers at site. |
| 246 | od45793/2020_2021/IA supply and installation of capacitor duty contactors 3Pole for 16 kvar with necessary electrical connection(2 NO/NC included) etc complete as per directions of departmental officers at site. |
| 247 | od45292/2019_2020/IA Fabrication, supply, conveyance and fixing cable entry/ wire way box made out 1.60 mm CRCA sheet ofsuitable size to match the switch gear and enabling the cables to be connected without strain, painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes and mounting to the switch gear etc as requiredas per directions of departmental officers at site. |
| 248 | od20644/2020_2021/IA Supply & renewal of bearing No. NU 314 etc complete as per directions of departmental officers at site. |
| 249 | od20645/2020_2021/IA Supply & renewal of bearing No 6311/6311 C3 etc complete as per directions of departmental officers at site. |
| 250 | od20646/2020_2021/IA Fabrication, supply, conveyance and fixing frame work made out of suitable size angle iron cut and welded to shape of suitable size painted with 2 coats of synthetic enamel paint over a coat of red oxide primer & with drilled holes to mount the switch gear, fixed to wall using suitable size anchor bolts or grouted to wall, making good the damages, colour washing etc as required as per directions of departmental officers at site. |
| 251 | od14942/2019_2020/IA conveyance for motor pump set from section to site(vallachira) including loading and unloading etc complete as per directions of departmental officers at site. |
| 252 | od14945/2019_2020/IA conveyance stator rotor starter from section to site(vallachira) including loading and unloading etc complete as per directions of departmental officers at site. |
| 253 | od20648/2020_2021/IA Dismantling the 51-75 HP motor into stator and rotor, cleaning the windings attending minor repairs, re taping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning and greasing the bearings with good quality grease, heating the windings, reassembling, test running including scrapping, cleaning and painting with enamel paint etc complete as per directions of departmental officers at site. |
| 254 | od20649/2020_2021/IA Dismantling the 60 - 75 HP oil starters by parts draining out the oil, (in case of oil starters ) cleaning the tank, terminal contacts, cutting, leveling and polishing the contacts wherever necessary, checking the tripping mechanism, replacing the damaged wires, attending minor repairs, cleaning the oil,(in case of oilstarters ), refitting, resetting and making the starter in good working condition including scrapping, cleaning and painting with a coat of enamel paint etc complete as per directions of departmental officers at site. |
| 255 | od20650/2020_2021/IA Refitting the 60-75 HP motor on base plate, leveling and correcting alignment with the pump coupling thesame giving connection, testing and trail run on full load etc complete as per directions of departmental officers at site. |
| 256 | od20651/2020_2021/IA Leading the burnt motor power greater than 60 HP and up to 75 HP ( already dismantled) from pump house to the nearest road side, loading into the vehicle, including charges for loading and unloading etc complete as per directions of departmental officers at site. |
| 257 | od20652/2020_2021/IA Seperate the motor in to stator and rotor , remove the whole burnt stator coil by cutting, pulling and cleaning the slots.Insulating the slots by using nomex paper, rewinding the complete stator slots by using same gauge new copper super enameled winding wire and taping coils.Providing new lead wires,sockets etc.Varnishing the coil using best quality insulation varnish and baking the coils, reassembling and test run the motor.(Less the cost of scarp copper wire) etc complete as per directions of departmental officers at site. |
| 258 | od20653/2020_2021/IA Charges for rewinding the burnt rotor after dismantling the damaged rotor winding from the rotor slots,cleaning the slots neatly, insulating the slots with correct class of insulating paper, winding the rotor with good quality correct gauge of super enamelled copper winding wires, closing the rotor slots with fibre wedges, putting proper inter layer insulation, connecting the coil end connection, providing new rotor lead wire, steel binding the overhang with proper insulation at both ends, heating the coils and varnishing with good quality insulation varnish, keep it for drying etc complete as per directions of departmental officers at site. |
| 259 | od20654/2020_2021/IA Leading the rewound motor power greater than 60 HP and up to 75 HP from workshop to pump house,unloading and conveying to the base plateetc complete as per directions of departmental officers at site. |
| 260 | od20668/2020_2021/IA Supply, conveyance and filling of good quality LT grade transformer oil etc complete as per directions of departmental officers at site. |
| 261 | 90.14.28.2 S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor etc complete as per directions of departmental officers at site. |
| 262 | od45794/2020_2021/IA Supply, installation testing and commissioning of Vacuum pump Kirloskar DV-40 or equivalent 5 HP,1450RPM,3 phase etc complete as per directions of departmental officers at site. |
| 263 | od45294/2019_2020/IA Fabrication supply and installation of foundation bolt with nuts of 25mm thickness for new foundation etc complete as per directions of departmental officers at site. |
| 264 | od45295/2019_2020/IA Supply and providing 25 mm green flexible hose and giving connection etc complete as per directions of departmental officers at site. |
| 265 | od45296/2019_2020/IA Supply and fitting 25 mm brass heavy duty half turn ball valve etc complete as per directions of departmental officers at site. |
| 266 | od20655/2020_2021/IA Supply and fixing single phasing preventer (SM 301 GIC/ L&T or equivalnt )and giving connections asrequired as per directions of departmental officers at site. |
| 267 | od20656/2020_2021/IAFabrication,Supply,conveyance and errecting 32 mm GI pipe with suitable specials such as coupler, union, bend, etc. and fixing on suction/delivery side of Vacuum pump set using shellack, rubber packing, bolt, nut and washer etc complete as per directions of departmental officers at site. |
| 268 | 90.14.24.17 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors etc complete as per directions of departmental officers at site. |
| 269 | 90.14.24.25 Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.15 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly PropyleneCapacitor, Box Type, suitable for direct connection to motors etc complete as per directions of departmental officers at site. |
| 270 | 90.12.7.20 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 95 sq mm etc complete as per directions of departmental officers at site. |
| 271 | 9.1.13 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.3 X 95 sq. mm (38mm) etc complete as per directions of departmental officers at site. |
| 272 | od45299/2019_2020/IASupplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length andother dimensions noted along with each size of glands for the following sizes of cables as required.(25 sq - 95sq mm with 20 mm wide x 1.20 mm thick clip) etc complete as per directions of departmental officers at site. |
| 273 | od20657/2020_2021/IA Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 50 sq mm 3 run etc complete as per directions of departmental officers at site. |
| 274 | od20658/2020_2021/IA Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 25 sq mm 3 run etc complete as per directions of departmental officers at site. |
| 275 | 90.6.4.53 Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 3 Run etc complete as per directions of departmental officers at site. |
| 276 | 1.17.30 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm etc complete as per directions of departmental officers at site. |
| 277 | 1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm etc complete as per directions of departmental officers at site. |
| 278 | 90.12.24.8 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.50 sq mm etc complete as per directions of departmental officers at site. |
| 279 | 90.12.24.3 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.6 Sq mm etc complete as per directions of departmental officers at site. |
| 280 | 90.12.24.4 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm etc complete as per directions of departmental officers at site. |
| 281 | 90.12.24.6 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.25 sq mm etc complete as per directions of departmental officers at site. |
| 282 | 90.12.24.1 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.2.5 sq mm etc complete as per directions of departmental officers at site. |
| 283 | 90.6.10.2 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm etc complete as per directions of departmental officers at site. |
| 284 | od45300/2019_2020/IA Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recessincluding cutting the wall and making good the same in case of recessed conduit as required 50 mm etc complete as per directions of departmental officers at site. |
| 285 | od45314/2019_2020/IA Supplying and clamping the following sizes of corrugated pvc flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages.20 mm diaetc complete as per directions of departmental officers at site. |
| 286 | od45315/2019_2020/IA Supplying and clamping the following sizes of corrugated pvc flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages.25 mm dia etc complete as per directions of departmental officers at site. |
| 287 | od45316/2019_2020/IA Supplying and clamping the following sizes of corrugated pvc flexible conduit with necessary compression gland with locking ring and check nut at termination pointed using suitable size GI/painted MS saddles spacing not exceeding 60 cms on surface including making good the damages.50 mm dia etc complete as per directions of departmental officers at site. |
| 288 | 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 289 | od45308/2019_2020/IA Supplying and laying 25 mm X 3 mm GI strip at 0.60 meter below ground as strip earth electrode, includingonnection/ terminating with suitable nut, bolt, spring, washer etc. as required as per directions of departmental officers at site. |
| 290 | 90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) etc complete as per directions of departmental officers at site. |
| 291 | 90.16.1.6 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) etc complete as per directions of departmental officers at site. |
| 292 | 90.16.3.9 Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing ofclamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip etc complete as per directions of departmental officers at site. |
| 293 | 90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) etc complete as per directions of departmental officers at site. |
| 294 | 90.16.5.6 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG) etc complete as per directions of departmental officers at site. |
| 295 | od18106/2019_2020/IA Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth busetc. as required including drilling necessary holes as required - 25 x 3 mm brass bolt & nut etc complete as per directions of departmental officers at site. |
| 296 | 14.10 Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement) etc complete as per directions of departmental officers at site. |
| 297 | Light wiring - 90.2.1.1 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm withspecials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point etc complete as per directions of departmental officers at site. |
| 298 | 90.2.1.6 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of thebox using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of lightpoints etc complete as per directions of departmental officers at site. |
| 299 | 90.2.1.3 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SPswitches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point etc complete as per directions of departmental officers at site. |
| 300 | 90.2.1.4 Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point etc complete as per directions of departmental officers at site. |
| 301 | 90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required as per directions of departmental officers at site. |
| 302 | 90.4.5.4 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), 300mm down rod , 2 number canopies, shackele kit, Copper winding, 3 number blades and all remaining accessories including safety pin, nut bolts, washers suitable for 230V/240V single phase AC supply etc. complete as required as per directions of departmental officers at site. |
| 303 | od45320/2019_2020/IA Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with 200 mm polished plastic shade and 7 W LED bulb including giving connection etc as required as per directions of departmental officers at site. |
| 304 | 90.3.20.3 Supply & installation of light fittings on TW round block Supply, conveyance installation testing andcommissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit thefitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box typefixture etc complete as per directions of departmental officers at site. |
| 305 | 90.3.21.3 Supply & installation of light fittings on \"C/U\" shaped flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. \"C/U\" brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc.as required.1200 mm 1X20W LED Lamp with box type fixture etc complete as per directions of departmental officers at site. |
| 306 | 90.3.18.2 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps etc complete as per directions of departmental officers at site. |
| 307 | 90.15.4.1 Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) etc complete as per directions of departmental officers at site. |
| 308 | 90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as requiredas per directions of departmental officers at site. |
| 309 | 1.17.11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm etc. as required as per directions of departmental officers at site. |
| 310 | 1.17.20 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm etc complete as per directions of departmental officers at site. |
| 311 | 90.6.10.1 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm etc complete as per directions of departmental officers at site. |
| 312 | 90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG) etc complete as per directions of departmental officers at site. |
| 313 | 90.16.1.2 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) etc complete as per directions of departmental officers at site. |
| 314 | 90.16.5.1 Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.2.00 mm (14 SWG) etc complete as per directions of departmental officers at site. |
| 315 | 90.16.5.2 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) etc complete as per directions of departmental officers at site. |
| 316 | od20660/2020_2021/IA Supply and providing the following sizes of bolt and nut with washers on the existing MS box , earth bus,earthing system etc. as required including drilling necessary holes as required - 12 x 3mm etc complete as per directions of departmental officers at site. |
| 317 | od20659/2020_2021/IA Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in theexisting opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core roundcopper conductor flex wire conforming to relevant ISS. - 200mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C. etc complete as per directions of departmental officers at site. |
| 318 | 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modularswitch, connection etc. as required as per directions of departmental officers at site. |
| 319 | 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole etc complete as per directions of departmental officers at site. |
| 320 | 2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps etc complete as per directions of departmental officers at site. |
| 321 | 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.40 ampsetc complete as per directions of departmental officers at site. |