| 1 | Wiring for light point / fanpoint /exhaust fan /call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C. |
| 2 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit, with 2-way modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Group C. |
| 3 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(i) 2x1.5 Sq. mm. |
| 4 | (ii) 2x4.0 Sq. mm. |
| 5 | (iii) 2x10 Sq. mm. |
| 6 | Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. (i) S.P. 5/ 6 Amps one way Modular switch. |
| 7 | (ii) 5 pin, 5/ 6 Amps Modular socket outlet. |
| 8 | Supplying and fixing stepped type Modular fan regulator on the existing modularbox including making connections etc. as required. |
| 9 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. |
| 10 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. |
| 11 | Supplying and fixing bakelite batten/angle holder including connections etc. as required:- |
| 12 | Supplyinganderection of 6amps. to 32 amps. rating, 10 KA breaking capacity, 240volts, \"C\" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(i) Single pole. Cat-A. |
| 13 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) 63 Amps. Cat-A. |
| 14 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (i) 63 Amps. Cat-A. |
| 15 | Supplyingand fixingoffollowingway, singlepoleandneutral sheetsteel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- (i) Double door-4 way |
| 16 | (ii) Double door-8 way |
| 17 | (iii) Double door-12 way |
| 18 | Earthing with G.Iearth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. |
| 19 | Extra for using salt and charcoal for pipe earth electrode complete as required. |
| 20 | Providing and fixing 6 SWG (4 mm dia.) G.I.wire on surface or in recess for loop earthing as required. |
| 21 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- (i) Exhaust Fan, Light duty,300 mm sweep |
| 22 | (ii) Exhaust Fan, Heavy duty, 300 mm sweep in/c fan shutter if required |
| 23 | Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to required length] with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan boxand earthing etc. as required:- (i) Ceiling Fan 1200 mm sweep, Category-A |
| 24 | Ceiling Fan 1400 mm sweep, Category-A |
| 25 | Supplying and fixing of bulk head fittingof all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but excluding CFL lamp including making connections, testing etc. as required. (i) Bulk head fitting, CFL type (Category-A) |
| 26 | Providing and laying of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering:-(i) Armoured cable 16 sq. mm (twin core) |
| 27 | (ii) Armoured cable 6 sq. mm (twin core) |
| 28 | (iii) Armoured cable 10 sq. mm (twin core) |
| 29 | Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVCsheathed, armoured/XLPE power cable, working voltage 1100 volts gradeon surface etc. of the required size:-(i) Armoured cable 6 sq. mm (twin core) |
| 30 | (ii) Armoured cable 10 sq. mm (twin core) |
| 31 | (iii) Armoured cable 16 sq. mm (twin core) |
| 32 | Supplying and erection of 3 stepped steel tubular swaged and welded pole of suitable length and dia. to be fixed up to a required planting depth below G/L in a hole of excavation about 30 cm dia. and of suitable depth, to be filled in up to 15 cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a 180 mmx100 mmx 45 mm deep, glass filled Nylan F.R. grade box for housing a 16 Amp. MCB in/c cost of MCBDB and MCB, the outer surface of the plinth to befinished with 1:3 cement plaster 6 mm thick, the fuse-box shall have a water tight cover, including painting of pole with two coats of approved color, brand and manufacture of paint over a priming coatcomplete in all respects as required:- (a). Overall length 7 meter, with planting depth 1.25 m, length of sections 4 m, 1.5m and 1.5m (bottom, middle and top respectively), outer dia and thickness of sections 127mmx4.5mm, 101.6mmx3.65mm and 76.1mmx3.25mm (bottom, middle and top respectively) with approximate weight 74 Kg. |
| 33 | Providing & fixing surface/ recess mounted 12/ 15W LED fitting of Syska/Havells/Philips/ Bajaj make as required complete in all respect.(i) 9 Watt |
| 34 | (ii) 15W |
| 35 | Supplying & fixing SKYLUKS LED surface mounting fitting 1\"*1\" LED luminaire panel of Bajaj/Havells/Philips/Syska20 /24WH |
| 36 | Providing &fixing LED Batten integrated LED channel of Bajaj make having Bajaj/ Havells / Philips make as below: (i) Batten/LED integrated channel fitting 10W |
| 37 | (ii) Batten/LED integrated channel fitting 20W |
| 38 | Providing & fixing LED street light fitting lnwhite colour with pressure die- cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection. As per CAT no. BRTFG 72W LED// White ) complete in all respect.The fitting is to be fixed on bracket mounted onpole/on wall including wiring and Bracket etcas required as approved and directed by engineer in charge of Bajaj/ Philips/ Havells make. |
| 39 | Providing and Laying 50/63 mm Dia DWC pipe as approved by Engineer -in Charge. |
| 40 | Providing and fixing 120 Watt Flood light with suitable arrangement on wall of Bajaj or its equivas per Bajaj Cat noBJFL 120 LED to the best satisfaction of Enginer -in- Charge. |
| 41 | Supplying and fixing of reputed make Light Emitting Diode of following rating as required.7-15 Watt. (phillips/ syska/or equivlent make |
| 42 | Providing and fixing Division Plate for Urinals 600mm x 300. Vitreous Chinaincluding carriage of material within all leads and lifts. |