Municipal Corporation-MC has published Provision Of E.I And Fans At 03 Nos Fixed Compactor Transfer Station (Fcts) 1.Near Shiv Mandir Rajokari,Ward No.69-S 2. At Mahilla Mangal, T Point Dakshinpuri, Ward No.79-S 3.Near Bandh Road ,Develi Ward No-76-S Under South Zone. Provision Of E.I And Fans. Submission Date for this Tender is 28-10-2021. Electrical Maintenance Tenders in DEVLI Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
3 | b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
4 | c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
5 | d) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
7 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 A |
8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
9 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 4 way (4 + 12), Double door |
10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) Single Pole |
12 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(40 Amp) |
13 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required |
14 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. Details of cost for 10 Metres |
15 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
16 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm |
17 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
18 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.a) 63 amps |
19 | Supply ofXLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KVgrade Conforming to IS 7098 of following Sizes a) (c) 2x10 Sqmm |
20 | b) (c) 4x25 Sqmm |
21 | S/I/T/C of LED Tube type Luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the followingExtruded Aluminium Batten prewired with high efficient LED with the following:(a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/watt >=95 (c) power factor >= 0.95 |
22 | Supply of 18"" ( 450 mm )sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required |
23 | Supply of 12"" ( 300 mm )sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required |
24 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.a) Upto 450 mm sweep |
25 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners.Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
26 | Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored |
27 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remainingaccessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required. |
28 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
29 | Supply and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 Pole and earth, metal enclosed plug top alongwith 20A "C" Curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the Socket out let and complete with connections, testing and commissioning etc. as required |
30 | Supply,installation,testing & commissioning of single / three phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtr. suction and delivery 25X25 mm. |
31 | SITC of60W LED Street light luminiare fitted with lens ,top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection(a) Total system wattage=60 watt+/-5%.(b) Luminiaire effiency >=100Lm/w.(c) power factor >=0.95.(d) Protection class -IP-66 |
32 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100A,30 KA FPMCCB |
33 | P/F Hot press sheet moulded compound (SMC) fire retradant (Temp.resistance up to 200 C),IP 55weather proof pole box of inner dimension 300x200x105 mm (NS)and outer dimension of 333x233x150 mm high dome complete with suitable arrangement for fixing of 4 nos of 6 to 32amp single pole MCB &63 Amp .Double pole isolator (MCB/Isolator excluded)with netural link duly shorting on DIN Channel with 2 nos of MS clamps with SS back plate of suitable sizewith danger monogram property printed on the cover etc as reqd. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy