| 1 | M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed. |
| 2 | M&L for Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed. |
| 3 | M&L for ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 ltr per hole by drilling 6mm dia holes at a downward angle of 45°@ 150mm C/C and sealing the same complete all as specified and directed. |
| 4 | M&L for ATT for Switch boards including removing the cover carefully and inserting adequate amount of chemical (powder) and closing the cover complete all as specified and directed. |
| 5 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing)and removing rubbish off the premises complete all as specified and directed. |
| 6 | M & L Light Shade vitrified tiles 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed |
| 7 | M & L Light Shade vitrified tiles 10 mm thick (square/rectangular)polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles but in verticle surface incl 10 mm thick rendering in CM 1:4 complete all as specified and directed |
| 8 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 9 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 10 | M&Lfor glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 11 | Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 12 | M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed. |
| 13 | M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed |
| 14 | M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 15 | M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed. |
| 16 | M & L for two coats of cement based paint over a coat of primer on new plastered surface of walls including preparation of surface complete all as specified and directed. |
| 17 | M&L for Repair to pot holes any depth, not exc 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, paths, etc cutting around edges to at least 25mm in depth, and making good by applying tack coat @ 5 Kgs per 10 Sqm and laying premixed bituminious macadam well rammed and sealed with paving bitumen 60/70 or VG-30 grade@ 9.8 Kgs per 10 Sqm, blinded with 0.09 Cum of stone chipping of size 6.3mm and again well rolled with 8 to 10 tonne power roller (Iincluding supply of pre-mixed macadam, binder and chipping) depth of pot holes exc 30mm complete all as specified and directed. |
| 18 | M&L for Preparing existing black top surface or bituminous macadam surfaces by brushing with brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc on back top/concrete surfaces than applying evenly priming tack coat with paving bitumen 60/70 or VG-30 penetration over the prepared surface by mechanical sprayer @ 5 Kgs/10 Sqm of surface area complete all as specified and directed. |
| 19 | M&L for applying bituminous premixed semi dense asphaltic concrete 30mm thick (consolidated thickness) with 5.5% binder content of paving bitumen 60/70 or VG-30 grade by weight of total mix including cement filler, on surfaces rolled & compacted with using 8 to 10 tonne capacity power roller to achieve the required compactness, camber and gradient mixed in hot mix plant using design mix and laid by mechanical paver finisher. Complete all as specified and directed. |
| 20 | M&L for premixed bituminous macadam laid, rolled and compacted to required gradient and camber n.exc 75mm thickness (consolidated thickness) with 4% binder content of VG -30 by weight of total mix, mixed in hot mix plant and laid by mechnical paver finished complete all as specified and directed. |
| 21 | M&L for preparation of existing bituminous surfaces, removing, dust, dirt grease and other foreign matters etc to receive the marking and M&L for thermo plastic (Reflective) line marking having 1.0 mm thickness (average) of uniform surface finish conforming to BS3262 (Part 1) 1989 read in conjunction with the MOSTspecification 803 clause 4.2.2 on bituminous surfaces in white/yelow clour and super imposed with glass beads confirming to BS 6088 read in conjuction with and MOST specification 803 clause 4.3.3 complete all as specified and directed.Note - MOST specification 803 shall be followed strictly for execution of work&suitable machine shall beused for the marking as approved by the GE. Shape & size/ patterns ofmarking shall be as approved by the GE. |
| 22 | S&F in repair cat eyes/road studs for roadways sign permanent surface mounted type having tough poly carbonate micro replicated corner cube reflector lenses with a protective abrassion resistant ceramor coating having body of weather proof and impact resistant thermoplasitic complete as per manufacturer,s instruction and as directed. (Colour :- Yellow/Red/Amber) Make: Series 290 of 3M or Road Star or Equivalent. |
| 23 | S&F in repair solar cat eyes/road studs size (mm) 125L x 125B x 25H including stem height 53mm approx housing dia cast aluminium (grade LM-6) fully water proof and weather proof and weatherproof coating visible distance upto 400mtr LED-6 super bright amber led (3 Nos each side) yellow charged, flush frequency 1.2 Hz-1.8Hz including solar panel 3.5V/110MA & battery one PC sub ‘C’ type Ni-Cd rechargeable battery 1.2V/2.5AH temp range 20C to 70C fixed on road for roadway signcomplete as per manufacturer’s instruction and directed. Make- 3M/Avery Dennision/Dark Eye/Green/Greenlite/Road Star Cat Part No. GSR-909 or Equivalent. |
| 24 | M&L for 75 mm thick spread thickness Moorum/Red Bajri spread, rolled & consolidated to required gradient & camber. Complete all as specified & directed. |