Agriculture Government Departments Closing in 0 days TDR #29625306

Setting Up Of Layer Breeding Farm Of Thirty Thousand Birds Capacity On Turnkey Basis At State Livestock Farm Complex, Ranjitpur, Goswamidihi, Saltora, Dist- Bankura, Pin-722158

Issued by Government Departments · State Livestock Farm Complex, Saltora, Bankura., West Bengal
Tender Value
32 Crore
Estimated cost
Bid Submission
13 Nov 2021
0 days left
EMD
64.01 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
State Livestock Farm Complex, Saltora, Bankura. → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Setting Up Of Layer Breeding Farm Of Thirty Thousand Birds Capacity On Turnkey Basis At State Livestock Farm Complex, Ranjitpur, Goswamidihi, Saltora, Dist- Bankura, Pin-722158

BOQ

Name of Work: Setting up of Layer Breeding Farm of Thirty Thousand birds capacity on Turnkey basis at State Livestock Farm Complex, Ranjitpur, Goswamidihi, Saltora, Dist- Bankura, PIN-722158.
Sl. No. Item Description
1CIVIL WORK (Annexure - C)
2Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed
3Dismantling all types of masonry excepting cementconcrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
4Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75m. In ground floor including roof.(a) upto 150 mm. Thick
5Dismantling R.C. floor, roof, beams etc. Includingtting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.
6Dismantling R.C. floor, roof, beams etc. Includingtting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof. (b) Extra rate for each addl floor over the rate ofground floor.
7Removal of rubbish,earth etc. from the working site and disposal of the same beyond thecompound, in conformity with the Municipal / Corporation Rules for such disposal, loading intotruck and cleaning the siten respect as per direction of Engineer in charge
8Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on a cleared)
9Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or tacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
10Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150mmincluding watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation
11(ii) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth.
12Supplying, spreading and compacting Sand to required thickness, in layers not exceeding 150 mm to proper gradient and camber, inundating each layer by water and packing and ramming layer by layer to achieve desired compaction, including lighting, guarding, barricading and making adequate earthen bundh where necessary, curing with water as per direction, mending cracks and depressions by ramming wherever necessary.
13Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
14Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety
15Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground flooras per relevant IS codes. (i) Pakur Variety
16Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
17Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work Ground Floor
18f) 25 mm to 30 mm shuttering without staging in foundation
19Batch Mixed concrete of M 25 Grade with well Graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu. M of Wet concrete produced in computerised batching plant underontrolled condition using approved super plasticizer designing concrete mix following I.S 10262 and I.S. 456 transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at required level of concreting and then placing the mix in its final location of form work compacting and curing the same complete as per specification and direction of the Engineer-in charge including hire charges of computerised batching plant, transit mixer with all accessories vibrators etc. inclusive of all other incidental charges in this connection complete but excludingost of hire charge of platform and its supporting staging which would be paid through separate item. Consumption of cement will not be less than 300 Kg of cement per cubic meter of controlled concrete but actual consumption will bedetermined on the basis of preliminary test and job mix foumula. [Cement tobe supplied by Deptt, if Cement is supplied by agency then item rate to be deduced as per ormat A of Annexure I][with Batching Plant & transit mixer]In Ground Floor& Foundation. [Pakur Variety]. (ii) With approved concrete pump
202. Lifting charge for items of 12 to 21 of subhead B with approved concretepump @ Rs 20/- per Cu.m per floor.]
21Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation and upto roof of ground floor/upto 4 m(i) Tor steel/Mild SteelI. SAIL/ TATA/RINLGround Floor
22(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
23(b) Anti termite treatment to back filling of the masonry foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrates ( 1% concentration) with water by weight at the rate of 7.5 Litres per sq. m. of the vertical surface of the substructure for each side of the foundation.. The work shall be carried out as per specification described in 6.2.2. of code IS-6313 (part -II) 1981. (Mode of measurment will be vertical area treated.)
24125 mm. thick brick work with 1st class bricks in cement mortar (1:4) inground floor.
25Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
26Brick work with 1st class bricks in cement mortar (1:6) ((b) In superstructure, ground floor
27Labour for Chipping of concrete surface before taking upPlastering work.
28Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar(a) 20 mm thick plaster
29(b)15 mm thick plaster
30With 1:4 cement mortar©10 mm thick plaster
3140mm. thick damp proof course with cement concrete withstone chips (1:1.5:3) [with graded stone aggregate 10 mmnominal size] and admixture of water proofing compound asper manufacturer\"s specification followed by two coat ofpolymer based paint, (1st coat after 4 to 5 days of concretelaying and 2 nd coat just before brick masonry work) asdirected
32Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
33Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.
34M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. III) For built up sections / srtuctural members of specified sections weighing not less than 22.5 Kg./m
35M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length,fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 Kg./m
36M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. span beyond 12 mtr and upto 20mtr
37M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction ofEngineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brandconforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labourreqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structuraltubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actualweight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additionalfloor or 4m. beyond the initial 8 m. or part thereof. ii) For trusses spanning above 12.00 m and up to 20 .00 m
38supplying, fitting and fixing PUF insulated sandwich roof panels of total thickness not less than 30 mm having pre-coated Galvanised sheet conforming to IS:14246-1995 of minimum thickness 0.5 mm for op & 0.4mm for bottom with minimum yield stress 550 MPa and Zinc coating of minimum 120 gsm as per IS: 277-1992 as skin on both side of PUR core (density 40 ± 2 kg/cum & selfextinguishing) affixed to enerate minimum adhesive strength (foam to steel) 2.9 kg/cm 2 and external face is made corrugated in shape for GI and PUR both material. The crest height of the panel shall be of 28 mm to 35 mminimum with 200 to 250mm c/c pitch. The Pre-coated sheet shall contain 5-7 microns epoxy primer over zinc coating on both side of the sheet and polyester top coat 15-18microns. The PPGL/ PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches while transportation. The roof panels are laid over a frame work of trusses, columns and purlins fixed using 90 mm & above selfdrilling self tapping (SDST) screw with rubber washer including all types of fasteners, ridges and end capping as per structural design & direction of Engineer-in Charge complete in all respect.30 mm thickness panel for roofs
39Galvanised iron sheet eaves gutter fitted and fixed with necessary 50 mm X 6 mm M.S flat bar clamps bent to design, bolts, nuts, washers etc. complete. (b) 300 mm. wide gutter
40Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed.(ii) 20 mm dia bolt. (c) 600 mm long
41Supplying, fitting and fixing PUF Insulated sandwich 60 mm thick & 1.0 m wide wall panels having PUR (density 40 ± 2 kg/cum & self extinguishing) conforming to IS:12436-1988 as core material with pre painted Galvanised sheet conforming to IS:14246-1995 of minimum thickness 0.5mm & minimum yieldstress 240 MPa with Zinc coating of minimum 120 gsm as per IS:277-1992 as skin on both faces affixed by self-bonding to generate minimum adhesive strength (foam to steel) 2.9 kg/cm 2 duly protected by 5-7 micron epoxy primer on both faces & polyester top coat of 15- 18 micron and shall be vertically joined together by tongue & groove joints & cam locks spaced @ 1m c/c along the joints to form a continuous wall and fixed by self-tapping GI screws with requisite length & number to the peripheral frame through \"Ú\" tracks/ rivets etc complete in all respects as per direction of the Engineer-in-Charge.
42Double kontted wove wire 2.1 m height (17 bars) vertical 300 mm apart horizontal spacing starting from 88 mm ending 200 mm top and bottom wire 10g and all otherntermediate and upright wire 9g with finished border 2 ply twisted fencing complete including tightening and fixing the same to posts with staples at every bar including cost of cutting and of lapping joints in net as necessary including cost of staples and wove wire.
43Expansion joint in floor roof etc. formed with V strips made of 22.5 cm wide strips of 24 gauge aluminium sheets with anchor arm projecting on each side (and end turned )embedded in adjacent cement concrete, including shaping and finishing the edges on either side of the joint (including the cost of bituminous filler if any) complete as per direction of Engineer-in-Charge.
44Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint ncluding scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.two coat
45Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. he rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion
46(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
47(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the urface, if necessary :(b) On steel or other metal surface :(iv) Two coats (with any shade except white)
48Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification andas per direction of the EIC. (In Ground Floor)(b) Two Coatsi) Water based interior grade Acrylic Primer
49Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of uperintending Engineer) : (Two coats) i) Standard Quality
50M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or crews etc. (length of straight not less than 230 mm)
51Supplying, fitting, fixing G.I chain link fencing 75 mm x 75 mm mesh 12 g wire to the R.C.C or wooden posts with galvanised hooks or staples etc. complete as per direction.
52M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of theEngineer-in -charge. In ground floor.
53Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete.[Using cement slurry at back side of tiles@ 4.4 kg/sq.m & white cement slurry for joint filling1.8 kg/sq.m] Area of each slab upto 0.2 Sq.m
54Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACPanel (Engravingthe rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filledwith foam and silicon sealant etc.complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. Mode of payment is on finished surface area of ACP) (a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating)
55Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of luminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including abour chargesfor fitting & fixing of aluminium 2-track/3-track sliding window withfixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge.10-12 Micron thickness Annodizing film Natural white
56Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lockil, doorvertical) , glazing clip made of Aluminium Alloy Extrusions conforming toIS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and irection of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing filmNatural white
57Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II) (i) 6mm thick
58Supply fitting fixixng in position C.I. manhole pit cover with rim round (ii)450x100x25kg approx
59(a) Supplying, fitting and fixing steel rolling shutter profile type with18 B.G . of approved type steel latche section 75mm wide, fitted withcoil wire spring to necessiate the fitting of required Nos. of C.I.Pulleys on heavy type solid drawn seamless steel tube complete withlocking arrangements both inside and outside specially builtup sideguide channels including providing a hood for the steel rollingshutter in the room, painting two coats of approved aluminium paintover a coat of red lead primer complete.
60(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
61(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6ment) as per Manufacturer\"s specification [Cement to be supplied by the Department]
62(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
63Dry Distemparing to interior walls or ceiling including cleaning, washing, smoothening surface(b) Two coat
64Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cementmortar (1:4) and 2 mm thick cementurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid afterapplication slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cementand colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directedd removal of wax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges omplete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be supplied by the contrr]e)(A) Deep Colour & White
65Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.
66(A) Floor … (b) Area of each tile above 0.09 Sq.m .. Coloured decorative
67B) Wall… (a) Area of each tile upto 0.09 Sq.m .. (ii) Other than Coloured decorative including white
68Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite doorshutters as per approved design with glass fibre reinforced plastic moulded skinsand a special sandwich core, so as to impart monolitaheic composite structure asper approved technology of Department of Science and Technology (DST) tosatisfy IS:4020 door testing performance criteria.In ground floor. 32 mm thick
69Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite doorframe as per approved section with glass fibre reinforced plastic moulded skinsand a special sandwich core, so as to impart monolitaheic composite structure asper approved technology of Department of Science and Technology (DST) tosafisfy IS: 4020 door testing performance criteria.. 66mm x 90mm
70Supplying, fitting and fixing Stainless Steel railing consist of 38mmdia and 900mm height vertical balustrade at every two alternativesteps, 50mm dia top rail, 3 (three) nos 19mm dia horizontalStrainless steel pipe and base/cover plate with Strainless SteelGRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Matfinish, complete as per direction of the Engineer-in-charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx)
71Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield ength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work).
72Supplying, fitting, fixing in position netting with PVC Coated Crinkle mesh of approved colour with wooden or steel or concrete frame work including cost of galvanised bolts, nuts, screws, nails,spacers, shapelding etc complete but excluding the cost of supporting frame works, battens etc.
73ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type
74(ii) Door stopper (Anodised aluminium)
75Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(viii) 100mm. X 75mm. X 3.50mm.
76Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (iv) 300mm x 19mm dia. bolt.
77Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(x) 300mm long x 12mm dia. bolt.
78Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:
79Bruss Nozel for car wash
80Suplly drawing and design as per site
81Supplying, Aluminium Grill with F channel frame of approved make and brand having ultimate tensile strength of 19 Kg/Sq.m. and modulus oflasticity 7000 kg/ sq.m., with 15 micron anodised fitted & fixed withnecessary screws etc. complete as per direction of Engineer-in-charge.Grill made with 10 mm wide and 5.2 mm thick aluminium sheet having expansion width of 66.00 mm and weight not less than 3.26 /Sq.m.
8218 mm. to 22 mm. thick, kota stone slab set in 20 mm thick(avg) cement mortar (1:4) in floor, stair & lobby includingpointing in cement slurry with admixture of pigment matchingthe stone shade, including grinding & polishing as perdirection of Engineer - in - charge to match with the existingwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m]
83Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick)
84P.V.C- False Ceiling : Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm part the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide.PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entireframework will not be visible from below P.V.C Section will be fixed with theframe with the help of self tapping steel screwsncluding all materials and labour charges including fitting,fixing the same and hoisting including mending thedamages in all respect and cost of paint as required as per direction of Engineerin- Charge . In ground floor.
85Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminiumsections for the following units:-Glazed aluminium sliding door and windows made of extruded and annodizedalloy aluminium sectios, fabrications, including cutting to proper shapeand size, drilling and aligning of window shutter frame fitted with in builtlocking arrangements, sliding rollers and other necessary fittings, fixture,adhesives and joineries along with extruded neoprine or EPDMgasketing in between window frame and masonry work (walls, column,beam.lintels etc.) as well as between glass and shutter frame for fixingglass and Polysulphide sealant and in between shutter and window framewhere necessary including cutting to requisite size and fixing glass asper drawing, specification and direction of EIC.The rate includes the hire charge of all tools and plants, including allincidental charges, adhesive, joineries such as screw, cleat angle etc. butexcluding the cost of extruded aluminium sections, glass, neoprene /EPDM gasket, locking arrangement and rollers. i ) 2 track sliding door and window.
86Aluminium sheet ridging fitted with self tapping screws,EPDM washers etc complete.(Minimum 225mm end lapping). (b) With 0.91 mm sheet
87Supplying Aluminium casted body hydraulic door closer as per I.S.I.
88Supplying 4 lever mortice lock or any approved make and brand as perdirection of the Engineer- in -Charge. ii) 100 mm.
89Supplying, fitting and fixing shower of approved brand and make. Chromium plated round shower with revolving joint 100 mm diawith rubid cleaning system (Equivalent to Code No. 542(N) & Model -Tropical / Sumthing Special of ESSCO or similar brand).
90Supplying, fitting and fixing shower of approved brand and make . Chromium plated shower arm 240 mm long (Equivalent to Code No.536(A) & Model - Tropical / Sumthing Special of ESSCO or similarbrand).
91Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock long body with wall flange with aerator(Equivalent to Code No. 512 & Model - Tropical / Sumthing Special ofESSCO or similar brand)
92Supplying, fitting and fixing bib cock or stop cock. Chromium plated Stop Cock (Equivalent to Code No. 513(A) &513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
93Supplying, fitting and fixing shower of approved brand and make. Hand Shower(Health Faucet) with 1mtr Fexible Tube with WallHook(Equivalent to Code No.573 & Model -ALLIED of Jaquar orsimilar).
94Wash basin vitreous china of approved make (without fittings)supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm woodblocks and C.I. brackets including two coats of painting of C.I. brackets. (i) 450 mm X 300 mm size
95Supplying,fitting and fixing approved brand P.V.C. CONNECTOR whiteflexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (v) 900 mm long
96Supplying, fitting and fixing Flat back urinal (half stall urinal) in whitevitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete. (iii) Corner urinal 440 mm X 345 mm X 250 mm
97Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware ofapproved make complete in position with necessary bolts, nuts etc. (b) With \"S\" trap
98Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete. (iv) Bestolite (solid type) white
99Supplying, fitting and fixing pillar cock of approved make. CP Pillar Cock - 15 mm. (Code No. 5011 & Model - FLORENTINE ofJAQUAR or equivalent).
100Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming toI.S. specification with P.V.C. fittings complete,C.I. brackets including twocoats of painting to bracket etc.
101Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thickwith silvering as per I.S.I. specifications supported on fibre glass frame ofany colour, frame size 550 mm X 400 mm
102Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass . (i) 25 mm dia. and 450 mm long
103Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted withholder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre ine measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work
104(ii) 15 mm dia. medium quality
105ii) 20 mm dia. medium quality
106(ii) 25 mm dia. medium quality
107(ii) 40 mm dia. medium quality
108(ii) 50 mm dia. medium quality
109(ii) 80 mm dia. medium quality
110(i) 100 mm dia. medium quality
111Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of allmaterials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials ith bituminous paint complete in all respect. (Payment will be made on thecentre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately)(viii) 80 mm dia. medium quality.
112Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).(iv) 50 mm dia
11315 mm dia
11420mm dia
115(ii) 80 mm dia
11625 mm dia
117(i) 100 mm dia
118Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to insidewalls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. with bazree(sail/tata/rinl)
119Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials inany position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for ccesories, specials.
12015 mm
12120 mm
12225 mm
12332 mm
12440 mm
12550mm
126Supply and installation of iron removal chamber with allied plumbing works as per below 1)Supply of Manganese dioxide (MnO2)Chamber , MS Vertical Vessel as per EIC (size 900mm x 1000mm )-1no 2)Supply and installation ofIron Remover Chamber, M S Vessel Vertical (2100mm x 2400mm) -1no3)Suplly of Filter media forfilteration of water as per charatceristic of water -55bags4) Supply fitting fixing M S Pipe of approved make and brand as per direction- of the Engineer - in - Charge 100mm dia-12mtr 5)Supply fitting fixingapproved make of Butter fly Valve as per direction of the Engineer - in - Charge100mm dia -3nos 6)Supply fitting fixing approved make M S Flange as per direction of the Engineer - in - Charge 100 mm dia -8nos 7)Painting with approvedquality paint and brand including smoothening surface by sand papering etc. on MS surface -1no8)Installation with inlet and outlet connection among Manganese dioxide (MnO2)Chamber , MS Vertical Vessel andIron Remover Chamber and MS Pipe-1no
127Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer(b) 1000 litre capacity
1282000 litre capacity
1295000 lit capacity
130Labour for punching hole in plastic water storage tank upto 50 mm dia.
131Construction of septic tank of different capacities as per approved drawing with 1stclass brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manholecover(heavy type)of approved make supplied, fitted and fixed in the 100mm thickR.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1)with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1)to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificialstone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting andfixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavationearth in all sorts of soil, shoring, bailing out and pumping out water as necessary,ramming, dressing the bed and fefilling the sides of the tanks with earth, removingspoils, filling up the chamber with clear water, removing foreign materials from thechamber and including constructing attached inspection pit as per approved drawingand connecting all necessary pipes, joints etc. with internal plaster work and artificialstone flooring is to be done with admixture of water proofing compound @ 0.5% byweight of cement with all costs of labour and materials. (iii) For 30 users
132Construction of circular soak well 2.5 metre deep in all types of sandy soils with drybrick work upto 1.6 metre from the bottom having 150 mm intermediate cement brickwork (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with20mm thick cement plastering (1:4) to inside face upto the depth of cement brickwork, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L.and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including fillingbottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size)including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stonechips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C.manhole cover (heavy type)of approved make supplied, fitted and fixed in the coverslab with necessary fittings, making nacessary arrangements for pipe connections,excavation of well including shoring, dewatering and removing the exess earth fromthe premises as per direction complete in all respect with all costs of labour andmaterials.
133Supplying, fitting and fixing PVC pipes for underground work ofapproved make of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). withall necessary accessories, specials viz. socket, bend, tee, union, cross,elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc.fitted including cost of all materials ,jointing materials, cutting pipes,making threads ,cutting trenches upto 1.5 metre below surface in all sortsof soil and refilling the same as directed complete in all respect. (Paymentwill be made on the centre line measurement of the total pipe lineincluding all specials No separate payment will be made for accessories,specials.) 150 mm
134Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match withGI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings asrequired,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre linemeasurements of total pipe line including all specials. No separatepayment will be made for accesories, specials. Payment for painting willbe made seperately)
13515 mm
13620 mm
137Supply of totally enclosed single panel metal clad 630A indoor H.T. Vacumm Circuit Breaker (VCB) having fault MVA-350 MVA panel suitable for incoming 11KV. 3Phase 50HZ A.C. main power supply. ( Make - ABB/Energy pack/ Pascal)
138Erection, testing and commissioning of HT VCB panel including positioning, assembling, levelling and fixing on the floor, fitting & checking allinstrument, relay, correctly set according to requirement.
139Supply, testing and commissioning of 3 phase cast resin 650 KVA Indoor Dry type transformer 11KV/433V, Dyne11, Power 630KVA, AN cooling as per IEC 60076-11/IS 11171. Rated Power 630KVA Cooling AN rated frequency 50HZ, Rated primary voltage 11 KV, Rated secondary voltage 433 Volt. Rated primary insulation lavel 12KV. Basic impulse level (BIL) 75 KVP. Off Circuit taping +5% to (-)5% @2.5%. Vector group Dyne 11, loses shall be as per ECBC (2009) guide line. % impedance 5% (IS- TOL). Maximun ambient temperature 50 Degree Celcious. Temperature rise 90 degree celcious over 50 degree celcious ambient.( Make - ABB/Energy pack/ Pascal)
140Supply and installation of LT Panel compiatable to 630 KVA Transformer withh necessary connection, consisting of incomer 800A OCB, 2 Nos outgoing 630A MCCB, Nos outgoing 250A MCCB, 2 nos outgoing-125A MCCB, 2 Nos. outgoing _63 A MCCB.Basbar 4 bar type of 1200Amp. rating.Consisting of ammeter, voltmerter selector switch etc. Panel should beFloor mounted of 14 SWG CRC sheet on channel railand to be powder coated.(Materials Make-ABB /L & T/ Havells)
141Supply & Fixing of Fire Bucket (04 nos.), Fire estinguisher (6 nos.), shock treatment chart (3 nos.), 2 pairs hand gloves (11 KVA grade), 8 nos. Suitable size Rubber Mat ( 11KVA Grade), danger Board (4 nos), First aid box etc.as per site requirement.
142Making testing arrangement and submitting the test report for high voltage testing of specified voltage including chacking and testing of all HT / LT equipment by authorised firm of Directorate of electricity.
143Supplying and fixing Sheet steel Main Switches on angle iron frame on walln63A L//T make
144Supplying and fixing 415 V, 16-32A per way, TPN MCBDB with SS enclosure double-door with IP-42/43 protection with Four Pole Isolators as incomer and SPMCBs (\"C\" Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand)4 way, Enclosure (607715), 63A FP Isolator, 12 nos. SP MCB.
145Supplying and fixing double-door (8+2) way SPN MCB Distribution Boardwith IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(as per Make: Legrand,607711)INCOMING-Supplying and fixing 240V 40A DP MCB Isolator on din rail of existing DBs and necessary connection. -- 1 Nos.(as per Make: Legrand)OUTGOING-Supplying and fixing 240V 6-16A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection-- 8Nos. (as per Make: Legrand)( For Light, PP, PG, Comp.)(Make: Legrand / Schneider / Crabtre/Havells
146Excavation of soil for installation of Earth Electrode and filling & ramming.
147Earthing Installation by GI pipe – (For Sub-station Neutral/Equipment earthing) :
148Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
149Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
150Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:
151By ISI-Medium GI pipe
152Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
153Extra for treatment of soil by using salt & charcoal or coke for plate electrode
154EARTH BUSBAR
155Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
156Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
157Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
158Earth Continuity Conductor:
159Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (a) Solid GI wire (i) No. 4 SWG
160COMPRESSION GLAND
161Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
1622Cx 10 sqmm XLPE Armoured Al. cable.
1634Cx 10 sqmm XLPE Armoured Al. cable.
1643.5Cx25sqmm XLPE Armoured Al. cable.
1653.5Cx35 sqmm XLPE Armoured Al. cable.
1663.5Cx50 sqmm XLPE Armoured Al. cable.
1673.5Cx70 sqmm XLPE Armoured Al. cable.
1683.5Cx150 sqmm XLPE Armoured Al. cable.
1693.5 Cx240 sqmm XLPE Armoured Al. cable.
1703.5 Cx300 sqmm XLPE Armoured Al. cable.
171Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
1722Cx 10 sqmm XLPE Armoured Al. cable.
1734Cx 10 sqmm XLPE Armoured Al. cable.
1743.5Cx25sqmm XLPE Armoured Al. cable.
1753.5Cx35 sqmm XLPE Armoured Al. cable.
1763.5Cx50 sqmm XLPE Armoured Al. cable.
1773.5Cx70 sqmm XLPE Armoured Al. cable.
1783.5Cx150 sqmm XLPE Armoured Al. cable.
1793.5 Cx240 sqmm XLPE Armoured Al. cable.
1803.5 Cx300 sqmm XLPE Armoured Al. cable.
181Laying of one No. cable upto 35 sqmmin underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith
182Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith
183Laying of two cables above 35 sqmm and upto 185 sqmm in an underground trench in singletier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
184Laying of one No. cable above 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
185Laying of two cables above 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
186Earthing Installation – with Copper Plate electrode :
187Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment
188Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
18940 mm dia
19050 mm dia
19165 mm dia
19280 mm dia
193100 mm dia
194Distributionwiring in 1.1 KVsingle core stranded \"FR\"PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required
1952 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
1962 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
1972 x 72/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
198Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\"(Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copperbar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish.Average run 10 mtr
199Do-do-do-- on board plug
200Supply & Fixing240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
201Supply and fixing of A.c. Starter 32 A with Socket and other accessoried.
202Supply & Fixing240 V, 20A, plug socket with separate20 A Piano key type switch(Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
203Supply & Fixing240 V, 6A, plug socket with separate 6 A Piano key type switch(Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
204Supply & FixingSocket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.
205Supply only 240V, 20W, Single Flourescent light fitting complete with all ccessories( mke Philips/ Havels/Syska)
206Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceilingwith 2 No. 20 mm dia EI conduit (14 SWG) supportsfixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastenerand other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
207Supplying & Fixing Out door type CFL luminaire (Bajaj make- 524020 / 020168) with epoxy powder coated sheet aluminium housing, aluminium reflector & clear acrylic cover and accessories incl. for 11/18 watts CFL S/L type lamp incl. S&F 15mm dia GI pipe bracket, clamp, nut & bolts etc..
208Supply only 240V, 1200 MM SWEEP CEILLING FAN complete with all ccessories( make ORIENT/ CROMPTONSTAR RATED
209Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
210Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
21130 cm (12\"
21238 cm (15\")
213Supply & Fixing louver shutterOF ALUMINIUM on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
21430 cm (12\"
21538 cm (15\")
216Supply and delivery of 250V. ISI marked , EPC make industrial type exhaust fanFOR WBSEDCL AND GENERATOR ROOM
21730 cm (12\" 920 RPM
21838 cm (15\") 920 RPM
219Supply and fixing Timer switch to be mounted near switch board to operte the exhaust fansin two halfs
220S & F 9\" sweep 1420 RPM ( EPC heavy duty make) A.C. Exhaust fan after necy. Wall cutting, plastering etc, grouting nut , bolts . S & F louver shuttering as per direction of EIC
221Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following complete in all respects. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per direction of Engineer-in- Charge. All coutgoingwitches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only.a. Outgoing:- DN3 400D, 6 nos.
222Supply of 150 sqmm 3 ½ Cr. aluminium armoured cable (pwd_14- K-10), Make- KEI/Havells/Gloster/Mescab
223Supply of 120 sqmm 3 ½ Cr. aluminium armoured cable (pwd_14- K-10), Make- KEI/Havells/Gloster/Mescab
224Supply of 35 sqmm 3 ½ Cr. aluminium armoured cable (pwd_14- K-10), Make- KEI/Havells/Gloster/Mescab
225Supply of 16 sqmm 4 Cr. aluminium armoured cable (pwd_14- K-10), Make- KEI/Havells/Gloster/Mescab
226Supply of 300 sqmm 3 ½ Cr. aluminium armoured cable (pwd_14- K-10), Make- KEI/Havells/Gloster/Mescab
227Supply of 1.5 sqmm 5 Cr. Copper armoured cable (pwd_14- K-11), Make- KEI/Havells/Gloster/Mescab
228Supply of 1.5 sqmm 4 Cr. Copper armoured cable (pwd_14- K-11), Make- KEI/Havells/Gloster/Mescab
229Supply of 1.5 sqmm 3 Cr. Copper armoured cable (pwd_14- K-11), Make- KEI/Havells/Gloster/Mescab
230Supply of 1.5 sqmm 2 Cr. Copper unarmoured screen cable (pwd_14- K-11), Make- KEI/Havells/Gloster/Mescab
231Supply of 2.5 sqmm 3 Cr. Copper armoured cable (pwd_14- K-11), Make- KEI/Havells/Gloster/Mescab
232Supply of 2.5 sqmm 4 Cr. Copper armoured cable (pwd_14- K-11), Make- KEI/Havells/Gloster/Mescab
233Supplying & fixing 20 amps TPN MCB [PWD-14, Pg-K-6]
234Supplying & fixing MCB Enclosure 2way [PWD-14, Pg-K-1]
235Supply & fitting fixing of 16 Mtrs High Mast ( Transail/Bajaj) shaft in two section, HT steel grade BSEN 10025 of S355JO Pole with foundation, necessary cable / panel with 6 (six) nos. 215 watt Flood light. Make- Philips/Crompton/ Havells in cluding 01 (one) no. air terminal. (Work should be complete in all respect.)
236S & F 70 watt LED Street light fitted with 40 mm GI pipe, 1.5 mtrs, avg. length having suitable size bend with necessary clamp and 1.5 Sq. mm PVC insulated stranded coper wire and making necessary connection. Make- Philips/Crompton/ Havells
237Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [PWD_17, Pg- E-6, Sl- 22]
238Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. [PWD_17, Pg- G-1, Sl- 2(e)]
239Supply, installation testing and commissioning of Synchronizing pannel for synchronizing 2 nos 320 KVA DG set including all accessories. Work should be completed in all respect. (make will be decided by the authority during execution).
240Supply & Installation, testing and commissioning of 320 KVA/256KW 3 Phase with AMF pannel D.G Set. (Make- Kirloskar/Jackson/Mahindra Powerol)
241Laying of two cables above 35 sqmm and upto 185 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed (pwd_17, F-2, 2b)
242Supplying and fixing of 3 ½ Cr. 150 sqmmcompression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables. (pwd_17, F-4, 7d)
243Supplying, fixing of feeder box with 300 Amp busber with
244M10 PVC Gland, 100mm pvc tie
245Supplying of 1KVA ONLINE UPS with Battery
246250Amp busber copper
247Supply and installation of 7.5 HP submersible pump motor set ( Make-Kirloskar), 415V, 2900 rpm, head 45 meters, discharge 100mm including star delta starter (L&T), trailing cable (Finolex) and allied accessories.
248Supply & fixing 240V, 25A, 3pin modular type plug socket ( makeNorth west/ Crabtree), without plug top and switch with 2 module GI modular type switch board with topcover plate flushed in wall and making mecy. Connections with PVC wire and earth continuity wire etc.
249Supply & fixing 240V, 25A, modular type starter ( makeNorth west/ Crabtree), with 25A moduler switch type DP MCB (CCurve) and 4 module GI modular type switch board with 4 module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connection with PVC Cu wire etc.
250S&F of 63A DP MCB with 2 way enclosure box after concealed in wall after cutting the all & mending good the damages to original finish incl. inter connection with suitable size of copper wire & provition for earthing arrangement.
251LED Phase indication box MS 200mm X 150mm with bakelite cover and three no LED indication Lamp (R,Y,B) for indication of the phase with complete internal wiring.
252Supply, installation testing and commissioning of 1ton 3 star rated room A.C (split type) including all accessories. Work should be completed in all respect.. (Make- O general/ Mitsubshi Electric)
253VEHICLE - (a) Cover Van - 2 Pcs. (b) Silo Filling Truck - 2 Pcs.
254Design, Supply, Installation, Commissioning of Commercial Layer Farm with Brooder, Grower & Layer Equipments with a capacity of 3 Lakh Birds. (i) LAYER BREEDER REARING HOUSE Equipment : 1 No. (ii) LAYER BREEDER PRODUCTION HOUSE Equipment : 3 Nos. (Details Specification as per Annexure - A & B)

AI Tender Summary

OUR REF NO 29625306
AUTHORITY Government Departments
TENDER VALUE 32 Crore
LAST DATE 13-11-2021
Authority
Authority Name Animal Resources Development Department
Work Description Setting Up Of Layer Breeding Farm Of Thirty Thousand Birds Capacity On Turnkey Basis At State Livestock Farm Complex, Ranjitpur, Goswamidihi, Saltora, Dist- Bankura, Pin-722158
Basic Detail
Tender No WBARD/WBLDC/NIT-311e/2021-22 Dated 21/10/2021
Bidding Type Tender
Location
City State Livestock Farm Complex, Saltora, Bankura.
State West Bengal
Key Dates
Publish Date 21 Oct 2021
Submission Date 13 Nov 2021
Open Date 16 Nov 2021
Finance
Tender Value 32 Crore
Tender Fee Ref. Documents
EMD 64.01 Lakhs
Exemption Not Available
Document List
0b24d2a5-80e3-4235-871d-b01166135cb7.html
BOQ_669281.xls
MAY-I-HELP-YOU.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 21, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 16, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0b24d2a5-80e3-4235-871d-b01166135cb7.html

xls

BOQ_669281.xls

pdf

MAY-I-HELP-YOU.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders