Electrical Associates Work For 06 Nos Lift Installation In Mutly Storey Building Gandhi, Nagar, Jaipur- 1 Sitc Of Wall / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalisedcubical Panel As Per Pwd Specification For Electrical Works, Gandhi Nagar Jaipur-Rajasthan

Public Works Department-PWD has published Electrical Associates Work For 06 Nos Lift Installation In Mutly Storey Building Gandhi, Nagar, Jaipur- 1 Sitc Of Wall / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalisedcubical Panel As Per Pwd Specification For Electrical Works. Submission Date for this Tender is 27-10-2021. Screws Tenders in Gandhi Nagar Jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

29618924
Electrical Associates Work For 06 Nos Lift Installation In Mutly Storey Building Gandhi, Nagar, Jaipur- 1 Sitc Of Wall / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalisedcubical Panel As Per Pwd Specification For Electrical Works
Open Tender
Indian
Rajasthan
Gandhi Nagar Jaipur
27-10-2021

Tender Details

Electrical Associates Work For 06 Nos Lift Installation In Mutly Storey Building Gandhi, Nagar, Jaipur- 1 Sitc Of Wall / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalisedcubical Panel As Per Pwd Specification For Electrical Works, Made Out Of Crca Sheet . Other Parameters Requiredas Per Point ( A ) , ( B ) , ( C ) , ( D ) Below:- 2 ( A ) Thickness Of Sheet Shallnot Be Less Than 1.6 Mm Up To 600 Mm Length / Widthof Any Compartment And Be Of 2.0 Mm Above 600 Mm. Load Bearing Structure Shall Beof 2.0 Mmthick Sheet Supported By Base M.S. Channel If Required . Side Walls And Cable Alley Compartments Having Bolted Type Doors With / Withoutdetachable Extension Type Structure 3 ( B ) Panel Shall Beduly Treated For Derusting In 7 Tank Process With Dephosphating And With Powder Coating Of Minimum 70 Microns On Both Side Of Panel In Desired Shadethe Panel Having Pu / Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness , Required Hardware, Separate Detachable Gland Plate M.S. Base Channel ( Min75mm ) , Hinged Door With Locking Arrangement For Equipment / Switchgear 4 [ C ) Interconnection Between Bus Bar And Switchgears / Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires ( Up To 125 Amp ) And By Solid Bus Bar ( >125 Amp ) . All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. 5 ( D ) Only Outer Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator. All As Per Drawing Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 6 Supplying And Fixing Of Aluminium ( Iec 60105 Iso 209-1, 2 ) / Copper ( Iec 60028 ) Bus Bar As Per Pwd Specification For Electrical Works, By Means Of Smc / Dmc Type Insulator, High Tensile Nuts And Bolts Spring Washers In Existing Panel Including Bending , Cutting In Required Shape And Size And Colour Coding With Heat Shrinkable Pvc Sleeves. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 7 Electrolytic Grade Aluminium Bus Bar 6010 Grade 8 Providing & Fixing Of ( Up To 500 ) V Range Volt Meter Moving Iron Ac Voltmeter Of Class 1.5 Accuracyas Per Is : 1248 On Existing Panelas Per Pwd Specification For Electrical Works, Making Connection By Pvc Insulated Copper Conductor With Pvc Sleeves / Channel Etc. As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 9 Analog Type ( 96 Mm X 96 Mm ) Flush Mounting 10 Providing & Fixing Of Ip 51Ct Operated Direct Reading Type Flush Mountingampere Meter Ofmoving Iron Type Of Class 1.5 Accuracy On Existing Panel As Per Pwd Specification For Electrical Works, Making Connection By Pvc Insulated Copper Conductor With Pvc Sleeves / Channel Etc. As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 11 Analog Type ( 96 Mm X 96 Mm ) Flush Mounting 12 Below 500 A 13 Providing & Fixing Of Bis Approvedcurrent Transformeras Per Pwd Specification For Electrical Works , Isi Marked As Peris 2705-1992 / Conforming To Iec 60044-1, With Secondary Terminalof Ct Shall Be Brought Out Suitable To A Terminal Block Which Shall Be Easier Accessible For Testing And Terminal Connection , With All Necessary Support In Existing Panel Including Connection Etc. As Requiredcurrent Transformer Resin Cast Wound Primary / Ring Type Tape Wound As Per Is 16227 With, Accuracy Cl, Ct Ratio And Burden As Specified. Isf<=5, Cu Cross Section Of Secondary Wire 1.5Sqmm ( Minimum ) , Including All Necessary Support In Existing Panel Including Connection Etc. As Required . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 14 C T Class 1, Ratio Upto 150 / 5, Burden 5 Va 15 Providing & Fixing Of Iso Certified Company Made Selector Switch Of 10 A For Voltmeter ( 4 Position ) Using High Grade Engineering Materialto International Standards With Cam Assemblyinsulation Of Glass Filled Polyamide With High Tracking Index. For Reliable And Stable Electrical And Mechanical Endurance Double Butt Contacts With Silver Bi-Metal On Copper Should Provided . Contact Assembly Is Of Operating Temp Range -25 Degree C To 55 Degree C, Frequency Upto 10 Khz. Switch Life Under Std. Op. Conditions Shall Be Mechanically Minimum 50000 Operations @300 Cycles / Hour And Electrically 10, 000 Operations At 100% Rated Duty For 100 Cycles / Hour Including Making Connection Etc.As Required . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 16 Providing & Fixing Of Iso Certified Company Madect Linked Selector Switch Of 10 Aforampere Meter ( 4 Position ) Using High Grade Engineering Materialto International Standards With Cam Assemblyinsulation Of Glass Filled Polyamide With High Tracking Index. For Reliable And Stable Electrical And Mechanical Endurance Double Butt Contacts With Silver Bi-Metal On Copper Should Provided . Contact Assembly Is Of Operating Temp Range -25 Degree C To 55 Degree C, Frequency Upto 10 Khz. Switch Life Under Std. Op. Conditions Shall Be Mechanically Minimum 50000 Operations @300 Cycles / Hour And Electrically 10, 000 Operations At 100% Rated Duty For 100 Cycles / Hour , Including Making Connection Etc.As Required . Allas Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 17 Providing & Fixing Of Iso Certified Company Made Ul Listed , Ip 65 110 / 220 V, Unibody Led Indicatinglamp Iec 60947 , Csa 22.2 With Integral Circuit, Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min.29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Ofbrass ( Tin Plated ) , Impulsedielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdcincluding Connection Etc. As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 18 Red / Yellow / Green Colour 19 Blue / White Colour 20 Sitc Of Ip 40 3 Pole Current Limiting Moulded Case Circuit Breaker ( Mccb ) Made Of Flame Retardent & Heat Resistant Materialhaving Following Current Rating, Short Circuitbreaking Capacityat 440 / 415 V, 50 Hz; O / L & S / C Settings As Per Pwd Specification For Electrical Works, Conforming To Is / Iec 60947 P -2 :2003 With Frontface And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push ( Test ) To Trip, Trip Time Less Then 10 Ms Under S / C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage 800 V, Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections With Lugs & Spreaders, Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 21 With Thermal Magnetic Release 22 Up To 100 Amp , 25 Ka, Adjustable O / L & Fixed S / C Setting, Ics = 100 % Icu 23 Sitc Of Ip 40Quick Make And Quick Break4 Pole Current Limiting Moulded Case Circuit Breaker ( Mccb ) Made Of Flame Retardent & Heat Resistant Materialhaving Following Current Rating, Short Circuitbreaking Capacityat 440 / 415 V, 50 Hz; O / L & S / C Settings As Per Pwd Specification For Electrical Works, Conforming To Is / Iec 60947 P -2 :2003 With Frontface And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push ( Test ) To Trip, Trip Time Less Then 10 Ms Under S / C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage 800 V, Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections With Lugs & Spreaders, Etc. As Required.Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 24 With Thermal Magnetic Release 25 125 Amp , 25 Ka, Adjustable O / L & Fixed S / C Setting, Ics = 100 % Icu 26 Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load Andsite Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Ofclass 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted Withexisting Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Ratingincluding Making Connections, Testing Etc. As Required.. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Test Reportsbefore Execution & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 27 Four Pole Mcb 28 50-63 A Rating 29 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 Forlower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existingsurface Or Recessed Pvc / Ms Conduit / Casing Capping Includingall As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work, Referannexure A Attached With This Bsr . 30 1 X 10.0 Sq.Mm 31 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un-Armoured / Armouredaluminiumcable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Worksin Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench With Filling Of Excavated Earth In Trench, On Existing Cable Trays Or On Surface Etc.Including Making Necessary Connection, Testing Etc. As Required Of Size Andas Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- 32 ( A ) Material :- H4- Gradealuminium Conductor Of Purity >99.6 %& As Peris:1554 P-I / Is :7098 P - I 33 ( B ) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testing Procedures . 34 ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities Forcables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted .All Above As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 35 Armoured Cable 36 70.0 Sq. Mm 37 3.5 Core 38 300.0 Sq. Mm 39 1 Core 40 Sitc Ofdraw Out Type 3 / 4 Pole Ip53, Ik 08 Door Interlock Air Circuit Breaker ( Acb ) As Per Pwd Specification For Electrical Works, Conforming To Is / Iec 60947 P - 2 :2003 In Existinglt Panel Suitable For Lt Installation 440 V, 50 Hz And Havingadjustable Over Load Short-Circuit, Earth Fault And Withseparate Led Indication For Each Type Of Fault , Password Protected Relase ( Trip Mechanisum ) Shall Confirm To Emi / Emc Test , Lcd / Leddisplay , Thermal Memory , Pollution Degree 4, Trip Free Mechanisum , Suitable For Ambient 50 Degree And Utilization Catagary B.In Built Electrical & Mechanical Anti Pumping Fearute , 100% Rated Neutral . Acb Shall Have Separate Indication For Service, Test, Isolation & Maintenance Position, Breaking Capacity Icu = Ics = Icw ( 1 Sec ) , U Imp - 12 Kv, Break Time Not More Then 25 Ms. Provision For Electrical & Mechanical Interlock Between Acbs, Min.Electricaloperation 10, 000 Upto 2000 A Rating And 5, 000 For2500 A. Including Making Connectionsetc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure A Attached With This Bsr . 41 Microprocessor Based Release Draw Out Type ( Manual Spring Charged ) 4Pole 42 800 A Rating, 50Ka 43 Providing & Fixing Of Ip20 Led Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back Lit Smd Mid Power Led Downlight With Die-Cast Aluminum Housing & Heat Sink For Heat Dissipation With Uv Stabilized Non Yellowish Diffuser With Internal / External Bis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% And In Compliance To Iec Standards. System Lumen Efficacy Min. 100 Lm / Watt, Thd < 10 % , P.F.=0.95, Cri >80, Life Time Of Minimum50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofbis Standard Andtrade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing Onhousing. Oemmust Have Its Own In House Nabl Acredeated Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 / Lm80 ) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . Foe Additional Technical Parameters Of Product / Work, Refer Annexure A Attacheded With This Bsr. 44 Surface Mounting 45 Led Downlight 18 / 20W 46 Providing And Fixingaluminum Workfor Doors , Windows, Ventilators And Partition With Extruded Built Up Standard Tubular / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is :733 And Is :1285, Fixed With Rawl Plugs And Screws Or With Fixing Clips , Or With Expansion Hold Fasteners Including Necessary Filling Up Of Gap. At Junctions , At Top , Bottom And Sides With Required Pvc / Neoprene Felt Etc. Aluminium Section Shall Be Smooth , Rust Free, Straight , Mitered And Jointed Mechanically Wherever Required Including Cleat Angle Aluminium Snap Beading For Glazing / Paneling , C.P. Brass / Stainless Steel Screws Al. Tower Bolt & Al. Handle & Al. Aldrop Etc., All Complete As Per Architectural Drawings And Thedirections Of Engineer- In – Charge . ( Glazing And Paneling To Be Paid For Separately ) . 47 For Fixed Portion 48 Anodised Aluminum ( Anodised Transparent 81 Dyed To Required Shade According To Is : 1868. ( Minimum Anodic Coating Of Grade Ac 15, Anodizing To Be Got Done From Approved Anodizer )

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
INR 4.90 Lakhs /-

BOQ Items

Name of Work: Electrical Associates work for 06 Nos Lift installation in Mutly Storey Building Gandhi, Nagar, Jaipur
Sl. No. Item Description
1SITC of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as per PWD specification for electrical Works, made out of CRCA sheet . Other parameters requiredas per point (a) ,(b), (c),(d) below:-
2(a)Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure
3(b)panel shall beduly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shadeThe panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear
4[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar(>125 amp ) . All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar.
5(d) only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator. All as per drawing pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
6Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar as per PWD specification for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
7Electrolytic grade Aluminium bus bar 6010 grade
8Providing & Fixing of(up to 500) V range Volt meter moving iron AC voltmeter of class 1.5 accuracyas per IS : 1248 on existing panelas per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
9Analog type ( 96 mm x 96 mm ) flush mounting
10Providing & Fixing of IP 51CT operated direct reading type flush mountingAmpere meter ofMoving Iron type of class 1.5 accuracy on existing panel as per PWD specification for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
11Analog type ( 96 mm x 96 mm ) flush mounting
12Below 500 A
13Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
14C T Class 1, Ratio upto 150/5, Burden 5 VA
15Providing & Fixing of ISO certified company made selector switch of 10 A for voltmeter (4 position ) using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
16Providing & Fixing of ISO certified company madeCT linked selector switch of 10 AforAmpere meter (4 position )using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc.as required . Allas per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
17Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicatinglamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
18Red/yellow/Green colour
19Blue / white Colour
20SITC of IP 40 3 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders,etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
21With Thermal Magnetic release
22up to 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
23SITC of IP 40quick make and quick break4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders,etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
24With Thermal Magnetic release
25125 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
26Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load andsite requirement) 4KV impulse withstand voltage,as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted withexisting distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A ratingincluding making connections, testing etc. as required.. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
27Four pole MCB
2850-63 A rating
29Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4,, in existingsurface or recessed PVC/ MS conduit/casing capping includingall as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work, referAnnexure "A" attached with this BSR .
301 x 10.0 sq.mm
31Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:-
32(a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I
33(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .
34(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
35Armoured Cable
3670.0 Sq. mm
373.5 core
38300.0 Sq. mm
391 core
40SITC ofDraw out type 3/4 pole IP53, IK 08 door interlock Air Circuit Breaker (ACB) as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 in existingLT panel suitable for LT installation 440 V, 50 Hz and havingadjustable over load short-circuit, earth fault and withseparate LED indication for each type of fault ,Password protected relase (trip mechanisum) shall confirm to EMI/ EMC test , LCD/LEDdisplay , Thermal memory , pollution degree 4, trip free mechanisum , suitable for ambient 50 degree and utilization catagary B.In built electrical & mechanical anti pumping fearute , 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 25 ms. Provision for electrical & mechanical interlock between ACBs, Min.electricaloperation 10,000 upto 2000 A rating and 5,000 for2500 A. including making connectionsetc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .
41Microprocessor based release Draw out type (Manual spring charged) 4Pole
42800 A Rating, 50kA
43Providing & Fixing of IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy min. 100 lm/watt, THD < 10 % ,p.f.=0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEMmust have its own in house NABL acredeated lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.
44Surface Mounting
45LED Downlight 18/20W
46Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).
47For fixed portion
48Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail