Bids Are Invited For Semiskilled - Maintanance And Operation Of E / M Installation Of Pump House At Cmp Unit In The Restricted Army Area Under Ge ( S ) Tezpur Round The Clock In 03 Shifts Of 08 Hours Each In All Days Including Sundays And Holidays -Assam

Indian Army-IA has published Bids Are Invited For Semiskilled - Maintanance And Operation Of E / M Installation Of Pump House At Cmp Unit In The Restricted Army Area Under Ge ( S ) Tezpur Round The Clock In 03 Shifts Of 08 Hours Each In All Days Including Sundays And Holidays . Submission Date for this Tender is 30-10-2021. Coats and Jackets Tenders in Assam. Bidders can get complete Tender details and download the document.




Tender Notice

29614777
Bids Are Invited For Semiskilled - Maintanance And Operation Of E / M Installation Of Pump House At Cmp Unit In The Restricted Army Area Under Ge ( S ) Tezpur Round The Clock In 03 Shifts Of 08 Hours Each In All Days Including Sundays And Holidays
Open Tender
Indian
Assam
30-10-2021

Tender Details

Bids Are Invited For Semiskilled - Maintanance And Operation Of E / M Installation Of Pump House At Cmp Unit In The Restricted Army Area Under Ge ( S ) Tezpur Round The Clock In 03 Shifts Of 08 Hours Each In All Days Including Sundays And Holidays With One Minimum Semiskilled Fgm In Each Shift For Operating / Maintanance Of Different Capacity Of Plants And Machineries. , Fgm - Maintanance And Operation Of E / M Installation Of Pump House At Bihugudi In The Restricted Army Area Under Ge ( S ) Tezpur Round The Clock In 03 Shifts Of 08 Hours Each In All Days Including Sundays And Holidays With One Minimum Semiskilled Fgm In Each Shift For Operating / Maintanance Of Different Capacity Of Plants And Machineries. , Semiskilled Fgm - Maintanance And Operation Of E / M Installation Of Pump House At Pump House No-1 ( A ) At 155 Bh In The Restricted Army Area Under Ge ( S ) Tezpur Round The Clock In 03 Shifts Of 08 Hours Each In All Days Including Sundays And Holidays With One Minimum Semiskilled Fgm In Each Shift For Operating / Maintanance Of Different Capacity Of Plants And Machineries. , Ref Mechanic - Maintanance And Operation Of E / M Installation Of Cold Storage At 155 Bh In The Restricted Army Area Under Ge ( S ) Tezpur Round The Clock In 03 Shifts Of 08 Hours Each In All Days Including Sundays And Holidays With One Minimum Semiskilled Ref Mechanic In Each Shift For Operating / Maintanance Of Different Capacity Of Plants And Machineries. , Semiskilled Ref Mechanic - Maintanance And Operation Of E / M Installation Of Cold Storage Plant At 56 Fmsd In The Restricted Army Area Under Ge ( S ) Tezpur Round The Clock In 03 Shifts Of 08 Hours Each In All Days Including Sundays And Holidays With One Minimum Semiskilled Ref Mechanic In Each Shift For Operating / Maintanance Of Different Capacity Of Plants And Machineries. , Mccb 400 Amps, 3 Pole, 415Volt, 50 Ka - Supply And Fix In Replacement Of Mccb 400 Amps, 3 Pole, 415Volt, 50 Ka Breaking Capacity With All The Necessary Electrical Connections, All As Specified And As Directed. ( Make: Legrand / L&T / Siemens / Abb / Schnieder / Havells , Earthing Set - Material And Labour For Earthing With Galvanised Steel Earth Plate Electrode 60Cm×60Cm×6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level ) With Top Edge Of The Plate Not Lessthan 1.5 Metres Below Normal Ground Level, Connected Togalvanised Iron Strip 32 × 6 Mm As Earthing Leadby Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No. 5 Connected To Earthing Test Point Including Taking Out Old Unsv Earth Pit. , Jointing Kit For 11 Kv - Material And Labour For Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Indoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For 3 Core Xlpe Armoured Aluminium Conductor Cable Of Size 185 Sqmm.Make-, M-Seal / Rychem / Denson / 3M , Relay - S & F As In Repair 3 Phase Overcurrent And Earth Fault Relay With Ct Rating 5A , Field Selectable , Idmt & Definite Time Characteristics With Last 30 Trip Data Recording With Date & Time , Auxiliary Supply 24-240 V Ac / Dc.Make-C&S / L&T / Havells / Abb / Bch , Apfc Controller - Supply And Fix In Repair Apfc Controller Of Size 144X144 Mm, 14 Step Contactor, Single Ct Input 1A / 5A, Voltage Input 415 V Suitable For Lv As Well As Ht Side Sensing, In Built Temperaturesensor, Capacitor Failure Indicator, Measurement Of Individual Current And Voltage Make-Abb / L&T / Havells / C&S / Bch , Capacitor Duty Contactor Type Mo C5 - Supply And Fix In Repair Capacitor Duty Contactor Type Mo C5, Built In Auxiliary Contacts 1No Suitable For 5 Kvar , 440 V, 3 Ph, 50 Hz.Make-Abb / L&T / Havells / C&S / Bch , Capacitor Duty Contactor Type Mo C10 - Supply And Fix In Repair Capacitor Duty Contactor Type Mo C10, Built In Auxiliary Contacts 1No Suitable For 10 Kvar , 440 V, 3 Ph, 50 Hz.Make-Abb / L&T / Havells / C&S / Bch , Capacitor Duty Contactor Type Mo C20 - Supply And Fix In Repair Capacitor Duty Contactor Type Mo C20, Built In Auxiliary Contacts 1No Suitable For 20 Kvar , 440 V, 3 Ph, 50 Hz.Make-Abb / L&T / Havells / C&S / Bch , Capacitor Duty Contactor Type Mo C50 - Supply And Fix In Repair Capacitor Duty Contactor Type Mo C50, Built In Auxiliary Contacts 1No Suitable For 50 Kvar , 440 V, 3 Ph, 50 Hz.Make-Abb / L&T / Havells / C&S / Bch , Cylinderical / Sqaure Capacito 5 Kvr - Supply And Fix Cylinderical / Sqaure Capacitor Super Heavy Duty Plus Of Capacity 5 Kvar Make-Abb / L&T / Havells / C&S / Bch , Cylinderical / Sqaure Capacito 10 Kvr - Supply And Fix Cylinderical / Sqaure Capacitor Super Heavy Duty Plus Of Capacity 10 Kvar Complete All As Specified And Directed.Make-Abb / L&T / Havells / C&S / Bch , Cylinderical / Sqaure Capacito 20 Kvr - Supply And Fix Cylinderical / Square Capacitor Super Heavy Duty Plus Of Capacity 20 Kvar Complete All As Specified And Directed.Mmake-Abb / L&T / Havells / C&S / Bch , Cylinderical / Sqaure Capacito 50 Kvr - Supply And Fix Cylinderical / Square Capacitor Super Heavy Duty Plus Of Capacity 50 Kvar Complete All As Specified And Directed.Make-Abb / L&T / Havells / C&S / Bch , 3 Ph Led Ammeter - Supply And Fix Digital Type 3 Ph Led Ammeter To Measure 0-60 Amp Complete All As Specified And Directed.Make-Abb / L&T / Havells / C&S / Bch , Start / Stop Lamp - Supply And Fix Start / Stop Lamp In Red And Green Complete All As Specified And Directed. , Power Management Device - Supply And Fix Reactive Power Management Device To Show Over Voltage, Over Compensation, Insufficient Compensation Alongwith C / K Settingcomplete All As Specified And Directed.Any Isi Marked Make Approved By Ge , 3 Ph Led Voltmeter - Supply And Fix Digital Type 3 Ph Led Voltmeter Cl 0.5 Input Voltage Measurement Range 50-520 Vac ( P-P ) Inbuilt Selector Switch For 3 Phase Meters Complete All As Specified And Directed.Make-L&T / Havells / C&S / L&T / Legrand , Servicing Of Panel - Taking Out Electric Connection Of 200 Kvar Apfc Panel For Servicing, Repairs And Re-Assembling Completecomprising Of The Following Including Testing And Commissioning All As Directed. ( A ) Checking The Serviceability Of All Parts, Cleaning, Alignment Of Closing / Opening Mechanisms And Re-Assembling The Unitcomplete. ( B ) Changing Of Unsv Electric Wiring Inside The Apfc Panel With Suitable Copper Wire And Lugs As Per Site Requirement. ( C ) Inspecting All Bolts, Nuts, Lugs, Pins And Ensure All Are In Place And They Are Tight Properly. , Repairs And Re-Assembling Of Vcb - Taking Down The Ht Vacuum Circuit Breaker Of Any Make, Capacity From 400-630 Amps, 11 Kv, 800Amps For Servicing, Repairs And Re-Assembling Completecomprising Of The Following Including Testing And Commissioning All As Directed.Scope Of Work Sheduled In Boq Notes. , Transformer Oil - Material And Labour For Filtration Of Transformer Oil Of Transformer 500 Kva With Ultra High Vacuum Filteration Machine Andchecking Dielectric Strength ( Bdv ) , Dielectric Dissipation Factor, Neutralizing Value ( Total Activity ) , Upto 60 Kv With 2.5 Mm Gap Sludge Content, Flush Point Of Transformer Oil From Standard Testing Laboratory All As Specified. Refilling The Transformer Oil In The Shell Of Transformer After Carrying Out Filteration And Heating Up Oil To Achive Required Dielectric Strength And Submitting The Test Result After Filteration Of Oil In Proper Proforma Duly Signed.Make-Castrol / Indian Oil / Hpcl / Power Oil , Transformer Oil With High Viscosity - Supply And Fill Transformer Oil With High Viscosity, High Resistance To Oxidation & Thermal Stability All As Specified And Directed. Make-Castrol / Indian Oil / Hpcl / Power Oil , Painting To 500 Kva Transformer - Material And Labour For Painting To 500 Kva Transformer Scrapping And Removing Oil Paint And Applying One Coats Of Synthetic Enamel Paint By Taking Due Care For Ht / Lt Side Supply All As Specified And Directed. , Syntheic Mat - Supply & Fixsyntheic Mat Of Size Not Less Than 2M X 1M X 19 Mm Includingtaking Out Old Unseveciable Syntheic Mat All As Specified And Directed. , Dc Power Bank 110 V / 7Ah - Supply And Fix Dc Power Bank 110 V / 7Ah, Input Voltage 110 V ± 5% Ac Single Phase, Inputfrequency 50 Hz, Output Voltage 110 Vdc ± 5% Vall As Specified And Directed. Make-Abb / L&T / Bch / Schiender. , Star Delta Starter - S&F Star Delta Starter For 20 Hp Submerssible Pump.Make-L&T / Havells / Legrand , Mccb 100 Amps - S&F Mccb 100 Amps, 16 Ka.Make-L&T / Havells / Legrand , Mccb 125 Amps - S&F Mccb 125 Amps, 16 Ka.Make-L&T / Havells / Legrand Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
INR 90860.0 /-
Tender Value
INR 45.43 Lakhs /-

BOQ Items

Sl. No. Item TitleItem Description
1SemiskilledMaintanance and operation of E/M Installation of pump house at CMP unit in the restricted Army area under GE(S) Tezpur round the clock in 03 shifts of 08 hours each in all days including Sundays and holidays with one minimum Semiskilled FGM in each shift for operating/maintanance of different capacity of plants and machineries.
2FGMMaintanance and operation of E/M Installation of pump house at Bihugudi in the restricted Army area under GE(S) Tezpur round the clock in 03 shifts of 08 hours each in all days including Sundays and holidays with one minimum Semiskilled FGM in each shift for operating/maintanance of different capacity of plants and machineries.
3Semiskilled FGMMaintanance and operation of E/M Installation of pump house at Pump house No-1(A) at 155 BH in the restricted Army area under GE(S) Tezpur round the clock in 03 shifts of 08 hours each in all days including Sundays and holidays with one minimum Semiskilled FGM in each shift for operating/maintanance of different capacity of plants and machineries.
4Ref MechanicMaintanance and operation of E/M Installation of Cold storage at 155 BH in the restricted Army area under GE(S) Tezpur round the clock in 03 shifts of 08 hours each in all days including Sundays and holidays with one minimum Semiskilled Ref Mechanic in each shift for operating/maintanance of different capacity of plants and machineries.
5Semiskilled Ref MechanicMaintanance and operation of E/M Installation of Cold storage Plant at 56 FMSD in the restricted Army area under GE(S) Tezpur round the clock in 03 shifts of 08 hours each in all days including Sundays and holidays with one minimum Semiskilled Ref Mechanic in each shift for operating/maintanance of different capacity of plants and machineries.
6MCCB 400 Amps, 3 pole, 415volt, 50 KASupply and fix in replacement of MCCB 400 Amps, 3 pole, 415volt, 50 KA breaking capacity with all the necessary electrical connections, all as specified and as directed. (Make: Legrand / L&T / Siemens / ABB /Schnieder/Havells
7Earthing setMaterial and labour for earthing with galvanised steel earth plate electrode 60cm×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected togalvanised iron strip 32 × 6 mm as earthing leadby means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point including taking out old unsv earth pit.
8jointing kit for 11 KVMaterial and labour for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm.Make-,M-Seal/Rychem/Denson/3M
9RelayS & F as in repair 3 phase overcurrent and earth fault relay with CT rating 5A , field selectable , IDMT & Definite time characteristics with last 30 trip data recording with date & time , Auxiliary supply 24-240 V AC/DC.Make-C&S/L&T/Havells/ABB/BCH
10APFC controllerSupply and fix in repair APFC controller of size 144x144 mm, 14 step contactor,single CT input 1A / 5A, voltage input 415 V suitable for LV as well as HT side sensing, in built temperaturesensor, capacitor failure indicator, measurement of individual current and voltage Make-ABB/L&T/Havells/C&S/BCH
11capacitor duty contactor type MO C5Supply and fix in repair capacitor duty contactor type MO C5, built in auxiliary contacts 1NO suitable for 5 KVAR , 440 V, 3 PH, 50 Hz.Make-ABB/L&T/Havells/C&S/BCH
12capacitor duty contactor type MO C10Supply and fix in repair capacitor duty contactor type MO C10, built in auxiliary contacts 1NO suitable for 10 KVAR , 440 V, 3 PH, 50 Hz.Make-ABB/L&T/Havells/C&S/BCH
13capacitor duty contactor type MO C20Supply and fix in repair capacitor duty contactor type MO C20, built in auxiliary contacts 1NO suitable for 20 KVAR , 440 V, 3 PH, 50 Hz.Make-ABB/L&T/Havells/C&S/BCH
14capacitor duty contactor type MO C50Supply and fix in repair capacitor duty contactor type MO C50, built in auxiliary contacts 1NO suitable for 50 KVAR , 440 V, 3 PH, 50 Hz.Make-ABB/L&T/Havells/C&S/BCH
15cylinderical/sqaure Capacito 5 KVRSupply and fix cylinderical/sqaure Capacitor super heavy duty plus of capacity 5 KVAR Make-ABB/L&T/Havells/C&S/BCH
16cylinderical/sqaure Capacito 10 KVRSupply and fix cylinderical/sqaure Capacitor super heavy duty plus of capacity 10 KVAR complete all as specified and directed.Make-ABB/L&T/Havells/C&S/BCH
17cylinderical/sqaure Capacito 20 KVRSupply and fix cylinderical/square Capacitor super heavy duty plus of capacity 20 KVAR complete all as specified and directed.MMake-ABB/L&T/Havells/C&S/BCH
18cylinderical/sqaure Capacito 50 KVRSupply and fix cylinderical/Square Capacitor super heavy duty plus of capacity 50 KVAR complete all as specified and directed.Make-ABB/L&T/Havells/C&S/BCH
193 Ph LED AmmeterSupply and fix digital type 3 Ph LED Ammeter to measure 0-60 Amp complete all as specified and directed.Make-ABB/L&T/Havells/C&S/BCH
20start/stop lampSupply and fix start/stop lamp in red and green complete all as specified and directed.
21power management deviceSupply and fix reactive power management device to show over voltage, over compensation, insufficient compensation alongwith c/k settingcomplete all as specified and directed.Any ISI marked Make approved by GE
223 Ph LED VoltmeterSupply and fix digital type 3 Ph LED Voltmeter Cl 0.5 Input voltage measurement range 50-520 VAC (P-P) Inbuilt selector switch for 3 phase meters complete all as specified and directed.Make-L&T/Havells/C&S/L&T/Legrand
23servicing of panelTaking out electric connection of 200 KVAR APFC panel for servicing, repairs and re-assembling completecomprising of the following including testing and commissioning all as directed. (a) Checking the serviceability of all parts, cleaning, alignment of closing/opening mechanisms and re-assembling the unitcomplete. (b) Changing of unsv electric wiring inside the APFC panel with suitable copper wire and lugs as per site requirement. (c) Inspecting all bolts, nuts, lugs, pins and ensure all are in place and they are tight properly.
24Repairs and re-assembling of VCBTaking down the HT vacuum circuit breaker of any make, capacity from 400-630 Amps, 11 KV, 800Amps for servicing, repairs and re-assembling completecomprising of the following including testing and commissioning all as directed.Scope of work sheduled in BOQ Notes.
25Transformer oilMaterial and labour for filtration of transformer oil of Transformer 500 KVA with ultra high vacuum filteration machine andchecking dielectric strength (BDV), dielectric dissipation factor,neutralizing value (total activity), upto 60 KV with 2.5 mm Gap sludge content, flush point of transformer oil from Standard Testing Laboratory all as specified. Refilling the transformer oil in the shell of transformer after carrying out filteration and heating up oil to achive required dielectric strength and submitting the test result after filteration of oil in proper proforma duly signed.MAKE-CASTROL/INDIAN OIL/HPCL/POWER OIL
26Transformer oil with high viscositySupply and fill Transformer oil with high viscosity, high resistance to oxidation & thermal stability all as specified and directed. MAKE-CASTROL/INDIAN OIL/HPCL/POWER OIL
27painting to 500 KVA transformerMaterial and labour for painting to 500 KVA transformer scrapping and removing oil paint and applying one coats of synthetic enamel paint by taking due care for HT/LT side supply all as specified and directed.
28syntheic matSupply & Fixsyntheic mat of size not less than 2m x 1m x 19 mm includingtaking out old Unseveciable Syntheic mat all as specified and directed.
29DC power bank 110 V/7AHSupply and fix DC power bank 110 V/7AH, input voltage 110 V ± 5% AC single phase, inputfrequency 50 Hz, Output voltage 110 VDC ± 5% Vall as specified and directed. Make-ABB/L&T/BCH/Schiender.
30Star Delta StarterS&F Star Delta Starter for 20 HP Submerssible pump.Make-L&T/Havells/Legrand
31MCCB 100 AmpsS&F MCCB 100 Amps,16 KA.Make-L&T/Havells/Legrand
32MCCB 125 AmpsS&F MCCB 125 Amps,16 KA.Make-L&T/Havells/Legrand
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy