}

Drugs And Medicines And Other Items Drugs And Medicines And Other Items , Drugs , Medicines & Other Items , Tab. Baricitinib , Tab. Doxycyline 100Mg , Tab. Ivermectin 12 Mg , Tab. Azithromycin 500 Mg , Tab. Azithromycin 250 Mg , Tab. Vitamin C 500 , Superintendent Associated Group of Hospital MGH Ho-Rajasthan

Dr. S.N.Medical College has published Drugs And Medicines And Other Items Drugs And Medicines And Other Items , Drugs , Medicines & Other Items , Tab. Baricitinib , Tab. Doxycyline 100Mg , Tab. Ivermectin 12 Mg , Tab. Azithromycin 500 Mg , Tab. Azithromycin 250 Mg , Tab. Vitamin C 500 . Submission Date for this Tender is 29-10-2021. Medicine Tenders in Superintendent Associated Group of Hospital MGH Ho Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

29610808
Drugs And Medicines And Other Items Drugs And Medicines And Other Items , Drugs , Medicines & Other Items , Tab. Baricitinib , Tab. Doxycyline 100Mg , Tab. Ivermectin 12 Mg , Tab. Azithromycin 500 Mg , Tab. Azithromycin 250 Mg , Tab. Vitamin C 500
Open Tender
Indian
Rajasthan
Superintendent Associated Group of Hospital MGH Ho
29-10-2021

Tender Details

Drugs And Medicines And Other Items Drugs And Medicines And Other Items , Drugs , Medicines & Other Items , Tab. Baricitinib , Tab. Doxycyline 100Mg , Tab. Ivermectin 12 Mg , Tab. Azithromycin 500 Mg , Tab. Azithromycin 250 Mg , Tab. Vitamin C 500 Mg , Tab. Zinc 10 Mg , Tab. Zinc 20 Mg , Tab. Zinc 50 Mg , Tab. Paracetamol500 Mg , Tab. Paracetamol650 Mg , Tab. B-Complex , Tab. Prednisolone 20 Mg , Tab. Rivaroxaban 10 Mg , Tab. Aspirin 75 Mg , Tab. Atorvastatin 10 Mg , Tab. Apixaban 2.5 Mg , Tab. Mg?² , Tab. Ca?² , Tab. K? , Tab. Posaconazole , Tab. Dexamethasone 0.5Mg , Tab. Methylprednisolone 8Mg , Tab. Methylprednisolone 16Mg , Tab. Monteleuckast + Levocetrizine , Syp. Dmr-Cpm , Syp. Paracetamol 125 / 5Ml , Syp. Paracetamol 250 / 5Ml , Syp. Azithromycin 100Mg / 5Ml , Syp. Azithromycin 200Mg / 5Ml , Syp. Zinc 20Mg / 5Ml , Syp. Posaconazole , Syp. Anti Cold , Syp. Dextromethorphan , Salbutamol Nebulizing Solution , Budesonide Nebulizing Solution , Monoclonal Antibody Cocktail ( Casirivimab & Imdevimab ) , Inj. Dexamethasone 4Mg / Ml , Inj. Remdesivir 200Mg , Inj. Remdesivir100mg ( For 20% Moderate To Severely ) , Inj. Tocilizumab 400Mg , Inj. Tocilizumab 200Mg , Inj. Piperacillin + Tazobactum , Inj. Enoxaparin 0.4Ml ( Low Molecular Weight Heparin ) , Inj. Enoxaparin 0.2Ml ( Low Molecular Weight Heparin ) , Inj. Ceftazidime , Inj.Cefoperazone + Sulbactum , Inj.Meropenam , Inj. Methyprednisolone 125 Mg , Inj. Ceftriaxone 1 Gm , Inj. Amoxy-Clav , Inj. Liposomal Amphotericin-B ( For Peribulber Injection ) , Inj. Mg?² , Inj. Ca?² , Inj. K? , Inj. Paracetamol Infusion 1Gm , Inj. Pantoprazole Iv 40Mg , Inj. Ondasetron Iv 4Mg , Inj. Metacloperamide Iv 10Mg , Inj. Noradrenaline 2Ml , Inj. Adrenaline 1Mg , Inj. Atropine 0.6Mg Iv , Inj. Dopamine 5Ml , Inj. Dobutamine 5Ml , Inj. Tramadol 100Mg , Inj. Tranexamic Acid 500Mg , Inj. Lmwh 0.6Cc , Inj. Heparine ( Unfractionated ) 5Ml Vial , Inj. Cefriaxone 1Gm , Inj. Piperacillin + Tazobactum 450Ml , Inj. Piperacillin + Tazobactum ( 1Gm+125Mg ) , Inj. Piperacillin + Tazobactum ( 4Gm+500Mg ) , Inj. Dexmeditomidine 100Mcg , Inj. Hydrocortisone 100Mg , Inj. Dexamethasone 8Mg , Inj. Propofol 20Ml , Inj. Haloperidol 5Mg / Ml , Inj.Insulin ( Regular ) 40 Iu / Ml , Inj. Insulin ( Glargine ) 100Iu / Ml , Inj. Pheniramine 2Ml , Inj. Sodium Bicarbonate 10Ml , Inj. Calcium Gluconate 10% 10Ml , Inj. Potassium Chloride 10Ml , Inj. Magnesium Sulphate 2Ml , Inj. Naloxone 0.4Mg / Ml , Inj. Phenytoin 100Mg , Inj. Valproic Acid 500Mg , Inj. Fluconazole 200Mg , Inj. Furosemie 20Mg , Inj. Deriphyllin , Inj. Mannitol 20% 100Ml , Inj. Multivitamin 10Ml Amp. , Inj. Morphine 10Mg , Inj. Ketamine 10Ml , Inj. Succinylcholine 10Ml , Inj. Midazolam 5Ml , Inj. Midazolam 1Mg / Ml , Inj. Fentanyl 5Ml , Inj. Albumin ( 20% ) 100Ml , Inj.Diazepam 5Mg / Ml , Inj. Promethazine 50Mg / Ml , Inj. Meropenem 1Gm , Inj. Meropenem 500Mg , Inj. Amikacin 500Mg / Ml , Inj. Pam ( Pralidoxime ) 500Mg , Inj. Methylprednisolone 1Gm , Inj. Methylprednisolone 500Mg , Inj. Methylprednisolone 250Mg , Inj. Methylprednisolone 125Mg , Inj. Methylprednisolone 40Mg , Inj. Lignocaine Iv 2% 50Ml , Inj. Esmolol 10Ml , Inj. Labetolol 4Ml , Inj. Glycopyrrolate 0.2Mg , Inj. Atracurium 25Mg , Inj. Atracurium 10Mg / Ml , Inj. Vecuronium 4Mg , Inj. Tericoplanin 400Mg , Inj. Tericoplanin 200Mg , Inj. Vancomycin 500Mg , Inj. Ivig 5Gm , Inj. Baricitanib 2Mg , Inj. Baricitanib 4Mg , Inj. Itolizumab 100Mg , Inj. Potassium Chloride 0.15 Gm / Ml 10 Ml. Amp. , Syp. Lactulose 100Ml , Tab. Doxycyclin 100Mg , Iv Fluids Isolyte P 500Ml ( Only Ffs Type ) , Iv Fluids Ns 500Ml ( Only Ffs Type ) , Iv Fluids Ns 100Ml ( Only Ffs Type ) , Iv Fluids Rl 500Ml ( Only Ffs Type ) , Iv Fluids D5 500Ml ( Only Ffs Type ) , Iv Fluids Dns 500Ml ( Only Ffs Type ) , Iv Fluids N / 2 500Ml ( Only Ffs Type ) , Iv Fluids D-25 100Ml ( Only Ffs Type ) , Duolin Respules 2Ml , Budesonide Respules 2Ml , Iv Cannula 18 G , Iv Cannula 20 G , Iv Cannula 22 G , Nrbm ( Hfm ) :- Should Have Following Specifications- • Disposable Adult Non Rebreathing Mask & Bag With Head Strap & Star Tubing Line • Non-Rebreathing Bag Prevents Rebreathing Of The Exhausted Air. • It Should Have A Low Resistance, Latex Free Check Value That Allows Exhaled Gas To Excape, Helping Patient Receive Better Quality Air. • It Should Have Adjustable Nose Clip Helps Ensure A Snug, Comfortable Fit. • Masks Should Come With A 750Ml Reservoir Bag And In A Standard Or Safety Vented Style. • It Should Have Adjustable Head Pump. • It Should Have Star Tubing Line & Have Length Three Meter Long. • It Should Have Pe Non-Woven Material. • It Should Have Individually & Sterile Packed. ( Company-Lifesol / Fisher & Pykel / Medex ( Smith / Romsons ) , Nebulization Mask , Simple Face Mask , Nasal Prongs. , Pmo Line , 3 Way Extension :- Should Have Following Specifications- 150Cm With Three Way Stop Cock. , Tracheostomy Tubes 7.0 , Tracheostomy Tubes 7.5 , Tracheostomy Tubes 8.0 , Central Line 3 Lumen :- Should Have Following Specifications- • Three ( 3 ) Lumen Central Venous Catheter With Sterile, Non Pyrogenic. • Straight Needle. • Catheter Size 7.0Fr • Length-16Cm • It Should Have Nitinol Guide Wire And Tecoflex Catheter. • Port: Distal-16 G, Proximal 18 G, Medial-18 G • Introducer Needle-18G X 7Cm ( 1 ) • Raulerson Syringe ( 1 ) • Heparin Injection Stopper ( 3 ) • Clamp Blue Cvc ( 3 ) • Scalpel Blade ( 1 ) • Guide Wire 0.036” X 45Cm / J-Tip Nitinol ( 1 ) • 5Ml Syringe 21G Needle ( 1 ) • Tissue Dialator 8F X10cm ( 1 ) • Clamp For Cvc ( 1 ) • Y-Shape Introducer Needle, 18G X7cm ( 1 ) , Tegaderm , Silk 2.0 , Lignocaine Jelly , Lignocaine For Infiltration 20Ml , Surgical Gloves 6.5 , Surgical Gloves 7.0 , Surgical Gloves 7.5 , Insulin Syringe 40Iu , Insulin Syringe 100Iu , Glucometer With Strip :- Should Have Following Specifications- Product Eligibility Criteria:- Product Should Be Ce As Per Ivd Or Usfda Certified- Manufacturer Should Be Iso 13485 Certified For Quality Standards- The Device And Test Strips Should Be Certified By The National Institutes Of Biologicals ( Nib ) Govt. Of India. Technical Specifications 1. Small, Portable And User Friendly Device Is Required. Blood Should Not Go Into The Glucometer While Measurement. 2. It Should Be Able To Measure Whole Bloo In Capillary Mode. 3. Measurement Range: 30 To 600 In Mg / Dl. 4. Accuracy Should Be As Per International Standard Iso 15197: 2013 ( Requirements For Blood-Glucose Monitoring Systems For Self-Testing In Mamaging Diabetes Mellitus ) . Supporting Certificates Or Test Reports From The National Institute Of Biologicals ( Nib ) Must Be Furnished Of Last 2 Years With The Technical Bid. 5. Reproducibility / Precision: ±5% 6. Display Shoul Be 40Mm±5Mm Or Better Measure Diagonally. 7. It Should Be Battery Operated Electronic System And The Battery Life Should Be For Atleast 500Tests. 8. Self Life Of Strips: Minimum 6 Months At The Time Of Delivery To Consignee. 9. Packing Of Strips Should Not Be More Than 50 Strips In A Pack. 10. Strips Should Work For Minimum 3 Months After Opening Of Strips Pack. 11. Operating Temperature For Both Device And Test Strip Should Be 100 C To 400 C 12. Shoul Have Strip Ejection Button Facility To Avoid Cross Contamination To The Operator. 13. Control Solution For Checking Reliability Of Strips Will Be Supplied Free Of Cost As & When Required. 14. Ready Availability Of Reagent Test Strips, Battery & Other Consumables In Jodhpur For At Least 5 Years. Scope Of Supply: A ) Glucometer: 1 No. B ) Standard Batteries: 1 Set C ) Carrying Case: 1No. D ) Control Solution / Control Strips E ) Glucose Test Dtrips: As Per Order F ) Auto Disables Llancets: As Per Order , Thermometer :- Should Have Following Specifications- • Accurate And Fast • Environmental Friendly • Safe To Use • Clear Visions Of Temperature • Beep Alert Sound • Should Be Used Orally, Rectally & Uner Armpit • Measurement Range: 32°C ( 89.6°F ) ----42°C • Low Temperature Display: Temperature<32°C ( 89.6°F ) Display L°C ( L°F ) • High Temperature Display: Temperature: Temperature>43°C ( 109.4°F ) Display H°C ( H°F ) • Accuracy: 35°C ( 95°F ) ----39°C ( 102.2°F ) ±0.1°C ( 0.2°F ) • Display Resolution: 0.1°C ( 0.1°F ) • Normal Beep Sound: 10 Long Beep Sound In 10 Seconds. • Fever Beep Sound?>37.8°C / 100°F ) : 30 Short Beep Sounds In 10 Seconds. • Auto Power Off: 8 Minutes±2 Minutes • Battery: Ag3 Or Lr41 • Life Of Battery: 2 Years Or 2500 Times. • Dimension: 125Mm X 19Mm X 11Mm • Unit Weight: Approx X 9.8 G ( Including Battery ) • Operational Condition: Temperature 10°C ( 14°F ) -----40°C ( 104°F ) Humidity 30%---85% Rh • Storage Condition: Temperature 10°C ( 14°F ) -----60°C ( 140°F ) Humidity 25%---90% Rh , Ketometer :- Should Have Following Specifications- Free Style Optium Neo Ketometer With Keto Strips. , Sphynomanometer:- Should Have Following Specifications- Required Technical Specifications:- A ) Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. B ) Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. C ) Should Have Backlight Lcd Isplay With Easy To View Reading In Dim Light. D ) Pressure Measurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. E ) Pressure Display Accuracy Of ±3 To 5Mm Hg F ) Pulse Rate Measurement Range Of 40 To 200 Per Minutes G ) Pulse Measurement Accuracy Of Within 5% H ) Should Include Ac Aapter ( Input Range 100-240V And Output Voltage Dc 6V ) , Preferably With Rechargeable Battery ( 3.6V To 4.8V, 1900 To 2400Mah ) I ) Should Be Supplied With Standard Adult Size Cuff ( 22 To 32Mm Size ) J ) Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. K ) Should Be Usfda Approved For Clinic / Hospital Use. , Blood Sugar Strips , Blood Ketone Strips , T-Piece :- Should Have Following Specifications- T-Piece With Port 22Mm-15Cm Reservoir Flex Tube And Oxygen Stem With Cap. Sterile, Disposable, Individially Packed. 7.6 Mm Port For Suction With Non-Popping Cap. 15Mm Et Connection. 2 Mtr. Star Lumen Oxygen Tube. , Bain Circuit :- Should Have Following Specifications- • Adult Type • Pvc Tube Length-3M • Corrugated Tube-22Mm; Length-1.6M • 22Mm Heidbrink Expiratory Valve • 15Mm / 22Mm Angle Mount • Antistatic Breathing Bag With Mount-2L Volume • 23Mm Male Plug In Mount • Outer Diameter Of Tube-22Mm • 22Mm Male / Female Circuit Adaptors X2 • 23Mm / 23Mm Female / Female Circuit Adaptor , Ventilator Circuit:- Should Have Following Specifications- • Sterile, Disposable, Double Limb ( Recommended Companies-Neon, Drager, Sewards, Altera ) , Hme Filter:- Should Have Following Specifications- • No Need To Disconnect Hme While Nebulization. • Should Have Higher Drug Deposition • No Peep Loss • It Should Maintain The Patency Of The Airways • It Should Reduce Infection • High Performance 3 Layer Air Filtration ( Hepa, Electrostatic & Hygroscopic ) , Catheter Mount:- Should Have Following Specifications- Expandable Catheter Mount With 360° Rotation & Suction Port ( Recommended Companies Intersurgical, Fisher Paykel, Romsons ) , Niv Mask –Adult :- Should Have Following Specifications- • Soft Silicon Cushion For Effective Sealing In Case Of Gas Flow. • Comfortable Seal And Light Weight • Quick Release Mechanism In Case Of Emergency • Single Motion Refit. • Soft And Flexible Headgear For Superior Comfort With Self-Adjusting Crown Strap. • Zones On Either Side Of The Mask Minimise Drag On Circuit. • Compatible With Ventilator For Bipap / Niv Use. , Niv Mask - Paediatric Should Have Following Specifications- • Soft Silicon Cushion For Effective Sealing In Case Of Gas Flow. • Comfortable Seal And Light Weight • Quick Release Mechanism In Case Of Emergency • Single Motion Refit. • Soft And Flexible Headgear For Superior Comfort With Self-Adjusting Crown Strap. • Zones On Either Side Of The Mask Minimise Drag On Circuit. Compatible With Ventilator For Bipap / Niv Use. , Oxygen Mask High Flow , Et Tubes ( 6.0, 6.5, 7.0, 7.5, 8.0 ) :- Should Have Following Specifications- • Pre-Sterilized, Single Use. • Siliconized Pvc Non-Toxic To Tissues. • Implantation Tested Marking On The Tube. • Thermo-Sensitive To Adapt To Tracheal Anatomy. • Non-Kinkable • Bevel With Murphy Eye. • Radio-Opaque Line All Along The Length Of The Tube To Detect The Correct Position On X-Ray. • Should Adopt Universal Connector Of 15Mm And Should Be Compatible With All Circuits. • Cuff Should Be Bonded, Non-Herniating • Size Range- 2.5 To 8.0 Mm In 0.5Mm Increments. • Inflation Of The Ballon Via A One-Way Valve With A Pilot Ballon And Should Be On The Concave Aspect Of The Tube. • Depth Marker At The Proximal Cuff End, 3Cm From The Cuff. • Cuff Should Be Smooth, Non-Traumatic, Low-Pressure High Volume. • Ett Opening Should Be Bevelled Type, Rounded Edge, Facing To The Left End Of The Tube With An Angle Of 38±10.0 • Marking On The Tube To Know The Depth Of Insertion And Fixation At Mouth. • Specified Mention On The Tube-Nasal / Oral; Outside Diameter Od In Mm; Inside Diameter Id In Mm , Adultet Tube Stylet :- Should Have Following Specifications- • Type, Aluminium Stylet • Purpose, To Secure Rigidity Of A Soft Catheter Or Cannula Or To Maintain Patency Of A Hollow Needle And Also For Proper Placement Of Endotracheal Tubes. • User Age, Adult • Application, Flexible Metallic Rod Inserted In Lumen Of Flexible Catheter To Stiffen And Give It Form During Its Passage And Also For Use Inside An Endotracheal Tube To Give It A Certain Shape Which Aids In Navigation Of The Tube Towards The Laryngeal Inlet. • Safety And Uni-Directional Adjustable End Cap To Preventfrom Advancing During Intubation. • Stylet Contain Malleable Wire Encased In A Specially Designed Pvc Sheath Which Allows Smooth Insertion. • Radiopaque. • Coude Tip ( Facilitates Insertion In Adults ) , Dimensions • Length ( Cm ) , 40 Centimeter • Suitable Et Tube Size ( Mm ) , 4 Milimeter • Suitable Et Tube Length ( Cm ) , 32 Centimeter • Weight Of Stylet ( Gms ) , 12 To 20 Gram • Standard Product Conformity To Standard, Eu-Ceisi Marked, No Cm / L Number ( If Product Is Isi Marked ) Packing • Packing, Individual Blister Pack 3 Pc Certifications & Reports • Submission Of Test Report From Central Government / Nabl / Ilac Accredited Lab Or Manufacturer’S Inhouse Test Report To Prove The Conformity To Declared Specification At The Time Of Supply, Yes • Certification Available, Eu-Ce • Submission Of All The Certifications To The Buyer Along With Supplies On Demand, Yes , Ppe Kit:- Should Have Following Specifications- • Disposable Coverall [ Made Of Non-Woven, Breathable Fabric Which Passes Astm F1670 ( Synthetic Blood Penetration Test ) Or Equivalent ] • Biosafety Goggles. • Long Shoe Cover 1 Pair With Water Impervious Seam. • Gloves: 2Pairs • N95 Respirator • Disposable Bag-1 No., Ce European Mark. A. Biosafety Goggles 1. High Quality Biosafety Goggles Should Cover Eyes From All The Sides, With Good Seal With The Skin Of The Face; Should Be Able To Accommodate Prescription Glasses. 2. The Goggles Should Be Made Of Transparent Material. 3. Flexible Frame Should Easily Fit All Face Contours Without Too Much Pressure. 4. Should Have Indirect Vents That Help Protect Against Splash 5, Fog And Scratch Resistant. 5. Adjustable Elastic Band To Secure Firmly So As Not To Become Loose During Clinical Activity. B.Coverall ( Single Use ) 1.Single Use Coverall For Use By Health Care Professionals. 2.White / Light Shades To Better Detect Possible Contamination. 3. Coverall Should Be Made Of A Non-Woven, Soft Breathable Fabric Which Passess Astm F1670 ( Synthetic Blood Penetration Test ) Or Equivalent. Seams Should Be Thermally Sealed Or Taped. Sitra / Drdo / Equivalent Certificate To Be Provided. 4. Coverall Shall Be Designed To Be Universal Fit Or Available In Different Sizes. 5. Design Should Allow Easy Donning & Safe Removal. 6. Coverall Should Have In-Built Hood Cap. 7. Zipper ( Lockable ) Of The Coverall Should Be In The Front And Should Be Covered With A Broad Flap To Completely Cover The Zipper To Avoid Accumulation Of Microbes Soft Elastic Should Be Fitted Around Front Of Hood, Wrists & Ankles. C. Specification Of N-95 Mask ( Without Valve ) 1.A Particulate Respirator With Filtration Efficiency Of 95% Or More Against Particulate Aerosols>0.3Μm. 2.It Should Be Disposable & To Be Able To Fit For Wide Range Of Face Sizes. 3.The Nose Clip Should Be Adjustable; Should Allow Molding To Fit On Nose; Preferably Should Have Foam On The Inner Surface To Allow Good Fit At Nose. 4. Ultrasonically / Thermal / Stapled Welded Head Bands Preferably With Adjustable Beads Should Be Fitted Robustly. 5. Should Niosh Approved. 6. Should Be Without Valve. 7. It Should Be Preferably Flat Style. 8. Brand Name, Nios, Tc Number, Model Number Should Be Printed In Mask. D.Shoe Cover ( Long ) 1.Made From Non-Toxic, Non-Woven, Thick Good Quality Fabric Which Is Water Impervious Even At The Seam. 2.Should Cover Lower Leg ( Till Just Below The Knees ) 3.Should Be Provided With Sturdy, Stitched Up Ties Near The Upper End To Secure The Shoe Cover. 4.Well Stitched In Universal Regular Size To Fit Standard Shoe Size Of 7 To 12. 5.Skid Resistant And Dust Proof. 6.Material Should Have Good Grip And Easy To Wear. E.Gloves 1.Nitrile Gloves Size-7 & 7.5 F.Face Shield Reusable 1.High Quality Face Shields For Use By Healthcare Professionals To Protect Face From Splashes; Completely Covers Three Sides & Length Of The Face & Neck. 2.The Shield Visor Should Be Made Of Optically Clear; Distortion Free, Sturdy Plastic, Acrylic Material Which Provides Good Visibility; The Material Should Be Scratch Resistant. 3.Adjustable Head Gear To Fix Firmly Around The Head & Fit Snuggly Against The Forehead. 4.Should Be Amendable To Decontamination Using Chemicals Such As Hypochlorite / Ethanol Etc. , N-95 Mask :- Should Have Following Specifications- 1. A Particulate Respirator With Filtration Efficiency Of 95% Or More Against Particulate Aerosols>0.3Μm. 2. Mask Will Have 6 Filtration Layers, Consisting Of Minimum 2 Meltblown Layers Of 25 Gsm Each For Bacteria And Particulate Filtration ( Manufacturer Should Mention Categorically About Classification Of All Layers In Separate Letter. ) 3. Bis Approved. ( Bis Certificate Should Be Attached. ) 4. Bis Certification License Number Should Be Printe On Each Mask Along With Bis. 5. Each Mask Will Follow Uv Sterilization Process Before Packaging. 6. It Should Have Durable Ultrasonic Sealing All-Around The Mask To Not Let Virus To Penetrate. 7. It Should Be Disposable, Non-Collapsible And To Be Able To Fit For Wide Range Of Face Sizes. 8. The In-Built Adjustable Nose Pin Should Have 100% Aluminium Strip, Should Allow Moulding To Fit On Nose; And Should Have Foam On The Inner Surface To Allow Good Fit At Nose. 9. Without Valve. 10. With Ultrasonically Sealed Flexible Ear And Head Loops ( Option Of Head Loop Also Should Be Available- Both Samples Should Be Submitted. ) 11. In Individual Packaging. , Surgical Mask , Surgical Cap , Airway Size-3 , Airway Size-4 , Airway Size-5 , Closed Suction Systems :- Should Have Following Specifications- Recommended Company ( Halyard, Medtronic, Cook ) Size- 7, 8, 10, 12 Fr 1. Catheter Should Be Made Of Medical Grae Silicon Material Having Number & Colour Graduation For Controlled Epth Suctioning. 2. Separate Three Y Connector For Different Et Tubes In The Single Pack. 3. It Should Have Zig Zag Suction Port At Catheter Tip For Preventing Blockage Through Proper Suctioning. 4. It Should Have Thumb Control System For Easy Identification Of Lock Or Unlock Vaccum System. , Suction Catheter , Foley’S Catheter , Silicone Foley’S Catheter , Ryles / Nasogastric Tube , Disp. Syringe With Needles- 2Ml , Disp. Syringe With Needles-5Ml , Disp. Syringe With Needles-10Ml , Disp. Syringe-20Ml , Disp. Syringe-50Ml , Iv Set , Bt Set , Feeding Bag , Uro Bag , Vtm Kits , Triple Layered Mask , Powder Free Nitrile Gloves , Hand Sanitizers 500Ml , Face Shields , Ppe Kits , Shoe Covers , Surgical Cap , Ecoshield , Knee Length Gown ( Back Open ) Disposable , Isopropranol Lol. Grade , Ethanol 500Ml / Absolute Alcohol 95-100% , Sodium Hypochlorite , Nuclease Free Water , Micropipette Tips Filtered, Sterile Rnase / Dnase 20Ul ( 10X96 ) , Micropipette Tips Filtered, Sterile Rnase / Dnase 100Ul ( 10X96 ) , Micropipette Tips Filtered, Sterile Rnase / Dnase 200Ul ( 10X96 ) , Micropipette Tips Filtered, Sterile Rnase / Dnase 1000Ul ( 10X96 ) , Eppendorftubes-Rnase / Dnase Free, Free Pyrogen ( 1.5Ml ) ( 1X500 Pack Size ) ( Size 10X96 ) , Tissue Paper Roll ( Size 10X96 ) , Abro Tape ( Size 10X96 ) , Waste Disposable Bags Autoclavable-Red 30L , Waste Disposable Bags Autoclavable-Yellow 30L , Waste Disposable Bags Autoclavable-Yellow 15L , Waste Disposable Bags Autoclavable-Black 30L , Polybag Ties , Sterile Falcon Tube-15Ml , Sterile Falcon Tube-30Ml , Lyzol , 10% Hypochlorite , Sterile Distilled Water , Baccishield ( 5 Ltrs. ) , Spray Bottle ( 5 Ltrs. ) , Spray Bottle Nozzles ( 5 Ltrs. ) , Discarding Jars ( 5 Ltrs. ) , Test Tube Rack Stands For 15Ml Falcon Tubes , Test Tube Rack Stands For 50Ml Falcon Tubes , Perkin Extraction System ( 96X10 ) , Zybio ( 32X10 ) , Zybio ( 96X10 ) , Qia Cube Ht ( Catalogue No.5262 ) ( 5X96 ) , Tecan ( 5X96 ) , Thermofisher ( 1X96 ) , Easymag , Master Mix Kit For Pcr Run For Covid 19 Rna , Multichannel Pipette- ( 1-10Ul ) ( Size 5X96 ) , Multichannel Pipette- ( 5-50Ul ) ( Size 1X96 ) , Multichannel Pipette- ( 30-300Ul ) , Multichannel Pipette- ( 500Ul ) , Multichannel Pipette- ( 1000Ul ) , Hand Dryer Machine , Foot Operated Dustbin Yellow , Foot Operated Dustbin Red , Foot Operated Dustbin Black , Cool Box For Master Mix , Cooler Racks For Tubes , D Glucan Assay , Galactomannan , Arterial Line ( Radial And Femoral ) : Should Have Following Specifications- All In One Arterial Catheter ( 20G ) With Dart Technique For Easy Insertion ) • Integrated Arterial Catheter With Spring Wire Guide. • Should Have Removable Suture Wings. • Should Have Catheter Length Of 3 Cm Or More • Should Have Guide Wire Length Of 12 Cm Or More. • Shoul Have Introducer Needle Of 22G Of Length 8 Cm Or More

Key Value

Document Fees
INR 1000 /-
EMD
Refer document
Tender Value
INR 1 Crore /-

BOQ Items

Name of Work: < Rate Contract for Drugs ,Medicines & other items >
Sl. No. Item Description
1Drugs ,Medicines & other items
2Tab. Baricitinib
3Tab. Doxycyline 100mg
4Tab. Ivermectin 12 mg
5Tab. Azithromycin 500 mg
6Tab. Azithromycin 250 mg
7Tab. Vitamin C 500 mg
8Tab. Zinc 10 mg
9Tab. Zinc 20 mg
10Tab. Zinc 50 mg
11Tab. Paracetamol500 mg
12Tab. Paracetamol650 mg
13Tab. B-Complex
14Tab. Prednisolone 20 mg
15Tab. Rivaroxaban 10 mg
16Tab. Aspirin 75 mg
17Tab. Atorvastatin 10 mg
18Tab. Apixaban 2.5 mg
19Tab. Mg?²
20Tab. Ca?²
21Tab. K?
22Tab. Posaconazole
23Tab. Dexamethasone 0.5mg
24Tab. Methylprednisolone 8mg
25Tab. Methylprednisolone 16mg
26Tab. Monteleuckast + Levocetrizine
27Syp. DMR-CPM
28Syp. Paracetamol 125/5ml
29Syp. Paracetamol 250/5ml
30Syp. Azithromycin 100mg/5ml
31Syp. Azithromycin 200mg/5ml
32Syp. Zinc 20mg/5ml
33Syp. Posaconazole
34Syp. Anti Cold
35Syp. Dextromethorphan
36Salbutamol Nebulizing Solution
37Budesonide Nebulizing Solution
38Monoclonal Antibody Cocktail (Casirivimab & Imdevimab)
39Inj. Dexamethasone 4mg/ml
40Inj. Remdesivir 200mg
41Inj. Remdesivir100mg (for 20% moderate to severely)
42Inj. Tocilizumab 400mg
43Inj. Tocilizumab 200mg
44Inj. Piperacillin + Tazobactum
45Inj. Enoxaparin 0.4ml (Low Molecular Weight Heparin)
46Inj. Enoxaparin 0.2ml (Low Molecular Weight Heparin)
47Inj. Ceftazidime
48Inj.Cefoperazone + Sulbactum
49Inj.Meropenam
50Inj. Methyprednisolone 125 mg
51Inj. Ceftriaxone 1 gm
52Inj. Amoxy-clav
53Inj. Liposomal AMPHOTERICIN-B (For peribulber injection)
54Inj. Mg?²
55Inj. Ca?²
56Inj. K?
57Inj. Paracetamol Infusion 1gm
58Inj. Pantoprazole IV 40mg
59Inj. Ondasetron IV 4mg
60Inj. Metacloperamide IV 10mg
61Inj. Noradrenaline 2ml
62Inj. Adrenaline 1mg
63Inj. Atropine 0.6mg IV
64Inj. Dopamine 5ml
65Inj. Dobutamine 5ml
66Inj. Tramadol 100mg
67Inj. Tranexamic acid 500mg
68Inj. LMWH 0.6CC
69Inj. Heparine (Unfractionated) 5ml vial
70Inj. Cefriaxone 1gm
71Inj. Piperacillin + Tazobactum 450ml
72Inj. Piperacillin + Tazobactum (1gm+125mg)
73Inj. Piperacillin + Tazobactum (4gm+500mg)
74Inj. Dexmeditomidine 100mcg
75Inj. Hydrocortisone 100mg
76Inj. Dexamethasone 8mg
77Inj. Propofol 20ml
78Inj. Haloperidol 5mg/ml
79Inj.Insulin (Regular) 40 IU/ml
80Inj. Insulin (Glargine) 100IU/ml
81Inj. Pheniramine 2ml
82Inj. Sodium Bicarbonate 10ml
83Inj. Calcium Gluconate 10% 10ml
84Inj. Potassium Chloride 10ml
85Inj. Magnesium Sulphate 2ml
86Inj. Naloxone 0.4mg/ml
87Inj. Phenytoin 100mg
88Inj. Valproic acid 500mg
89Inj. Fluconazole 200mg
90Inj. Furosemie 20mg
91Inj. Deriphyllin
92Inj. Mannitol 20% 100ml
93Inj. Multivitamin 10ml amp.
94Inj. Morphine 10mg
95Inj. Ketamine 10ml
96Inj. Succinylcholine 10ml
97Inj. Midazolam 5ml
98Inj. Midazolam 1mg/ml
99Inj. Fentanyl 5ml
100Inj. Albumin (20%) 100ml
101Inj.Diazepam 5mg/ml
102Inj. Promethazine 50mg/ml
103Inj. Meropenem 1gm
104Inj. Meropenem 500mg
105Inj. Amikacin 500mg/ml
106Inj. PAM (Pralidoxime) 500mg
107Inj. Methylprednisolone 1gm
108Inj. Methylprednisolone 500mg
109Inj. Methylprednisolone 250mg
110Inj. Methylprednisolone 125mg
111Inj. Methylprednisolone 40mg
112Inj. Lignocaine IV 2% 50ml
113Inj. Esmolol 10ml
114Inj. Labetolol 4ml
115Inj. Glycopyrrolate 0.2mg
116Inj. Atracurium 25mg
117Inj. Atracurium 10mg/ml
118Inj. Vecuronium 4mg
119Inj. Tericoplanin 400mg
120Inj. Tericoplanin 200mg
121Inj. Vancomycin 500mg
122Inj. IVIG 5gm
123Inj. Baricitanib 2mg
124Inj. Baricitanib 4mg
125Inj. Itolizumab 100mg
126Inj. Potassium chloride 0.15 gm/ml 10 ml. amp.
127Syp. Lactulose 100ml
128Tab. Doxycyclin 100mg
129IV Fluids Isolyte P 500ml (only FFS type)
130IV Fluids NS 500ml (only FFS type)
131IV Fluids NS 100ml (only FFS type)
132IV Fluids RL 500ml (only FFS type)
133IV Fluids D5 500ml (only FFS type)
134IV Fluids DNS 500ml (only FFS type)
135IV Fluids N/2 500ml (only FFS type)
136IV Fluids D-25 100ml (only FFS type)
137Duolin Respules 2ml
138Budesonide Respules 2ml
139IV Cannula 18 G
140IV Cannula 20 G
141IV Cannula 22 G
142NRBM (HFM) :- should have following specifications- • Disposable Adult Non Rebreathing Mask & Bag With Head Strap & Star Tubing Line • Non-Rebreathing Bag prevents rebreathing of the exhausted air. • It should have a low resistance, latex free check value that allows exhaled gas to excape, helping patient receive better quality air. • It should have adjustable nose clip helps ensure a snug, comfortable fit. • Masks should come with a 750ml reservoir bag and in a standard or safety vented style. • It should have adjustable head pump. • It should have star tubing line & have length three meter long. • It should have PE Non-Woven material. • It should have individually & sterile packed. (Company-Lifesol/Fisher & Pykel/ Medex (Smith/Romsons)
143Nebulization Mask
144Simple Face mask
145Nasal Prongs.
146PMO Line
1473 Way Extension :- should have following specifications- 150cm with three way stop cock.
148Tracheostomy tubes 7.0
149Tracheostomy tubes 7.5
150Tracheostomy tubes 8.0
151Central Line 3 lumen :- should have following specifications- • Three (3) Lumen Central Venous Catheter with Sterile, non pyrogenic. • Straight needle. • Catheter size 7.0Fr • Length-16cm • It should have Nitinol Guide wire and tecoflex catheter. • Port: Distal-16 G, Proximal 18 G, Medial-18 G • Introducer needle-18G X 7cm (1) • Raulerson Syringe (1) • Heparin injection stopper (3) • Clamp Blue CVC (3) • Scalpel blade (1) • Guide wire 0.036” X 45cm/ J-tip Nitinol (1) • 5ml syringe 21G needle(1) • Tissue Dialator 8F X10cm (1) • Clamp for CVC (1) • Y-Shape Introducer Needle, 18G X7cm(1)
152Tegaderm
153Silk 2.0
154Lignocaine Jelly
155Lignocaine for Infiltration 20ml
156Surgical gloves 6.5
157Surgical gloves 7.0
158Surgical gloves 7.5
159Insulin Syringe 40IU
160Insulin Syringe 100IU
161Glucometer with strip :- should have following specifications- Product Eligibility Criteria:- Product should be CE as per IVD or USFDA certified- Manufacturer should be ISO 13485 certified for quality standards- The device and test strips should be certified by the National Institutes of Biologicals (NIB) Govt. Of India. Technical Specifications 1. Small, portable and user friendly device is required. Blood should not go into the glucometer while measurement. 2. It should be able to measure whole bloo in capillary mode. 3. Measurement range: 30 to 600 in mg/dl. 4. Accuracy should be as per International Standard ISO 15197: 2013 (Requirements for Blood-glucose monitoring systems for self-testing in mamaging diabetes mellitus). Supporting certificates or test reports from the National Institute of Biologicals (NIB) must be furnished of last 2 years with the technical bid. 5. Reproducibility/Precision: ±5% 6. Display shoul be 40mm±5mm or better measure diagonally. 7. It should be battery operated electronic system and the battery life should be for atleast 500tests. 8. Self life of strips: Minimum 6 months at the time of delivery to consignee. 9. Packing of strips should not be more than 50 strips in a pack. 10. Strips should work for minimum 3 months after opening of strips pack. 11. Operating temperature for both device and test strip should be 100 C to 400 C 12. Shoul have strip ejection button facility to avoid cross contamination to the operator. 13. Control solution for checking reliability of strips will be supplied free of cost as & when required. 14. Ready availability of reagent test strips, battery & other consumables in Jodhpur for at least 5 years. Scope of supply: a) Glucometer: 1 no. b) Standard batteries: 1 set c) Carrying case: 1no. d) Control solution/Control strips e) Glucose test dtrips: As per order f) Auto disables llancets: As per order
162Thermometer :- should have following specifications- • Accurate and fast • Environmental friendly • Safe to use • Clear visions of temperature • Beep alert sound • Should be used orally, rectally & uner armpit • Measurement Range: 32°C (89.6°F)----42°C • Low Temperature Display: Temperature<32°C (89.6°F) display L°C(L°F) • High Temperature Display: Temperature: Temperature>43°C(109.4°F) Display H°C(H°F) • Accuracy: 35°C(95°F)----39°C(102.2°F)±0.1°C(0.2°F) • Display Resolution: 0.1°C(0.1°F) • Normal Beep sound: 10 long beep sound in 10 seconds. • Fever Beep sound?>37.8°C/100°F): 30 short beep sounds in 10 seconds. • Auto Power Off: 8 minutes±2 minutes • Battery: AG3 or LR41 • Life of Battery: 2 years or 2500 times. • Dimension: 125mm x 19mm x 11mm • Unit weight: approx x 9.8 g (including battery) • Operational condition: Temperature 10°C(14°F)-----40°C(104°F) Humidity 30%---85% RH • Storage condition: Temperature 10°C(14°F)-----60°C(140°F) Humidity 25%---90% RH
163Ketometer :- should have following specifications- Free Style Optium Neo Ketometer with Keto Strips.
164Sphynomanometer:- should have following specifications- Required Technical specifications:- a) Should be able to measure blood pressure and pulse rate in adult as well as pediatric patients. b) Should be based on oscillometric measurement technology, using dynamic linear deflation method. c) Should have backlight LCD isplay with easy to view reading in dim light. d) Pressure measurement range should be 60 to 250mm Hg systolic, and 40 to 200mm Hg diastolic. e) Pressure display accuracy of ±3 to 5mm Hg f) Pulse rate measurement range of 40 to 200 per minutes g) Pulse measurement accuracy of within 5% h) Should include AC aapter (input range 100-240V and output voltage DC 6V), preferably with rechargeable battery (3.6V to 4.8V, 1900 to 2400mAh) i) Should be supplied with standard adult size cuff (22 to 32mm size) j) Single button operation for start and stop functions with auto-inflation of blood pressure cuff. k) Should be USFDA approved for clinic / hospital use.
165Blood Sugar Strips
166Blood Ketone Strips
167T-Piece :- should have following specifications- T-piece with port 22mm-15cm reservoir flex tube and Oxygen stem with cap. Sterile, Disposable, Individially packed. 7.6 mm port for suction with non-popping cap. 15mm ET connection. 2 mtr. Star lumen Oxygen Tube.
168Bain Circuit :- should have following specifications- • Adult type • PVC Tube length-3m • Corrugated tube-22mm; length-1.6m • 22mm Heidbrink expiratory valve • 15mm/22mm angle mount • Antistatic Breathing Bag with mount-2L volume • 23mm Male plug in mount • Outer diameter of tube-22mm • 22mm Male/Female Circuit adaptors X2 • 23mm/23mm Female/Female Circuit adaptor
169Ventilator Circuit:- should have following specifications- • Sterile, Disposable, double limb (recommended Companies-Neon, Drager, Sewards, Altera)
170HME Filter:- should have following specifications- • No need to disconnect HME while Nebulization. • Should have Higher Drug Deposition • No PEEP Loss • It should maintain the patency of the Airways • It should reduce Infection • High performance 3 Layer air filtration (HEPA, Electrostatic & Hygroscopic)
171Catheter Mount:- should have following specifications- Expandable catheter mount with 360° rotation & suction port (recommended companies Intersurgical, Fisher Paykel, Romsons)
172NIV Mask –Adult :- should have following specifications- • Soft Silicon Cushion for effective sealing in case of gas flow. • Comfortable seal and light weight • Quick release mechanism in case of emergency • Single motion refit. • Soft and flexible headgear for superior comfort with self-adjusting crown strap. • Zones on either side of the mask minimise drag on circuit. • Compatible with ventilator for BIPAP/NIV use.
173NIV Mask - Paediatric should have following specifications- • Soft Silicon Cushion for effective sealing in case of gas flow. • Comfortable seal and light weight • Quick release mechanism in case of emergency • Single motion refit. • Soft and flexible headgear for superior comfort with self-adjusting crown strap. • Zones on either side of the mask minimise drag on circuit. Compatible with ventilator for BIPAP/NIV use.
174Oxygen Mask High Flow
175ET Tubes( 6.0, 6.5,7.0, 7.5, 8.0):- should have following specifications- • Pre-sterilized, single use. • Siliconized PVC non-toxic to tissues. • Implantation tested marking on the tube. • Thermo-sensitive to adapt to tracheal anatomy. • Non-kinkable • Bevel with Murphy eye. • Radio-opaque line all along the length of the tube to detect the correct position on X-ray. • Should adopt universal connector of 15mm and should be compatible with all circuits. • Cuff should be bonded, non-herniating • Size range- 2.5 to 8.0 mm in 0.5mm increments. • Inflation of the ballon via a one-way valve with a pilot ballon and should be on the concave aspect of the tube. • Depth marker at the proximal cuff end, 3cm from the cuff. • Cuff should be smooth, non-traumatic, low-pressure high volume. • ETT opening should be bevelled type, rounded edge, facing to the left end of the tube with an angle of 38±10.0 • Marking on the tube to know the depth of insertion and fixation at mouth. • Specified mention on the tube-Nasal/Oral; Outside diameter OD in mm; Inside diameter ID in mm
176AdultET Tube Stylet :- should have following specifications- • Type, Aluminium stylet • Purpose, To secure rigidity of a soft catheter or cannula or to maintain patency of a hollow needle and also for proper placement of endotracheal tubes. • User age, Adult • Application, Flexible metallic rod inserted in lumen of flexible catheter to stiffen and give it form during its passage and also for use inside an endotracheal tube to give it a certain shape which aids in navigation of the tube towards the laryngeal inlet. • Safety and uni-directional adjustable end cap to preventfrom advancing during intubation. • Stylet contain malleable wire encased in a specially designed PVC sheath which allows smooth insertion. • Radiopaque. • Coude tip (facilitates insertion in adults), DIMENSIONS • Length (Cm), 40 centimeter • Suitable ET tube size (mm), 4 milimeter • Suitable ET tube length (Cm), 32 centimeter • Weight of stylet (gms), 12 to 20 gram • Standard Product Conformity to standard, EU-CEISI Marked, No CM/L Number (if product is ISI marked) PACKING • Packing, Individual blister pack 3 pc CERTIFICATIONS & REPORTS • Submission of Test Report from Central Government/NABL/ILAC accredited Lab or Manufacturer’s inhouse Test Report to prove the conformity to declared specification at the time of supply, Yes • Certification Available, EU-CE • Submission of all the certifications to the buyer along with supplies on demand, Yes
177PPE Kit:- should have following specifications- • Disposable Coverall [made of non-woven, breathable fabric which passes ASTM F1670(Synthetic Blood Penetration Test) or equivalent] • Biosafety Goggles. • Long shoe cover 1 pair with water impervious seam. • Gloves: 2pairs • N95 respirator • Disposable Bag-1 no., CE European mark. A. Biosafety Goggles 1. High quality biosafety goggles should cover eyes from all the sides, with good seal with the skin of the face; should be able to accommodate prescription glasses. 2. The goggles should be made of transparent material. 3. Flexible frame should easily fit all face contours without too much pressure. 4. Should have indirect vents that help protect against splash 5, Fog and scratch resistant. 5. Adjustable elastic band to secure firmly so as not to become loose during clinical activity. B.Coverall (single use) 1.Single use coverall for use by health care professionals. 2.White/light shades to better detect possible contamination. 3. Coverall should be made of a non-woven, soft breathable fabric which passess ASTM F1670 (Synthetic Blood Penetration Test) or equivalent. Seams should be thermally sealed or taped. SITRA/DRDO/ equivalent certificate to be provided. 4. Coverall shall be designed to be universal fit or available in different sizes. 5. Design should allow easy donning & safe removal. 6. Coverall should have in-built hood cap. 7. Zipper (lockable) of the coverall should be in the front and should be covered with a broad flap to completely cover the zipper to avoid accumulation of microbes Soft Elastic should be fitted around Front of hood, wrists & ankles. C. Specification of N-95 Mask (Without Valve) 1.A particulate respirator with filtration efficiency of 95% or more against particulate aerosols>0.3µm. 2.It should be disposable & to be able to fit for wide range of face sizes. 3.The nose clip should be adjustable; should allow molding to fit on nose; preferably should have foam on the inner surface to allow good fit at nose. 4. Ultrasonically/thermal/stapled welded head bands preferably with adjustable beads should be fitted robustly. 5. Should NIOSH approved. 6. Should be without valve. 7. It should be preferably flat style. 8. Brand name, NIOS, TC number, model number should be printed in mask. D.Shoe Cover (Long) 1.Made from non-toxic, Non-woven, thick good quality fabric which is water impervious even at the seam. 2.Should cover lower leg (till just below the knees) 3.Should be provided with sturdy, stitched up ties near the upper end to secure the shoe cover. 4.Well stitched in universal regular size to fit standard shoe size of 7 to 12. 5.Skid resistant and dust proof. 6.Material should have good grip and easy to wear. E.Gloves 1.Nitrile gloves size-7 & 7.5 F.Face Shield Reusable 1.High quality Face Shields for Use by healthcare Professionals to protect face from splashes; completely covers three sides & length of the face & neck. 2.The Shield visor should be made of optically clear; distortion free, sturdy plastic, acrylic material which provides good visibility; the material should be scratch resistant. 3.Adjustable Head Gear to Fix Firmly around the head & fit snuggly against the forehead. 4.Should be amendable to decontamination using chemicals such as hypochlorite/ethanol etc.
178N-95 Mask :- should have following specifications- 1. A particulate respirator with filtration efficiency of 95% or more against particulate aerosols>0.3µm. 2. Mask will have 6 filtration layers, consisting of minimum 2 Meltblown layers of 25 GSM each for bacteria and particulate filtration (manufacturer should mention categorically about classification of all layers in separate letter.) 3. BIS approved.( BIS certificate should be attached.) 4. BIS certification License number should be printe on each mask along with BIS. 5. Each mask will follow UV sterilization process before packaging. 6. It should have durable ultrasonic sealing all-around the mask to not let virus to penetrate. 7. It should be disposable, non-collapsible and to be able to fit for wide range of face sizes. 8. The in-built adjustable nose pin should have 100% aluminium strip, should allow moulding to fit on nose; and should have foam on the inner surface to allow good fit at nose. 9. Without valve. 10. With ultrasonically sealed flexible Ear and Head loops (option of head loop also should be available- both samples should be submitted.) 11. In individual packaging.
179Surgical Mask
180Surgical Cap
181Airway size-3
182Airway size-4
183Airway size-5
184Closed Suction Systems :- should have following specifications- Recommended company (Halyard, Medtronic, Cook) Size- 7,8,10,12 Fr 1. Catheter should be made of medical grae silicon material having number & colour graduation for controlled epth suctioning. 2. Separate three Y connector for different ET tubes in the single pack. 3. It should have zig zag suction port at catheter tip for preventing blockage through proper suctioning. 4. It should have thumb control system for easy identification of lock or unlock vaccum system.
185Suction Catheter
186Foley’s Catheter
187Silicone Foley’s Catheter
188Ryles / Nasogastric Tube
189Disp. Syringe with needles- 2ml
190Disp. Syringe with needles-5ml
191Disp. Syringe with needles-10ml
192Disp. Syringe-20ml
193Disp. Syringe-50ml
194IV set
195BT set
196Feeding Bag
197Uro Bag
198VTM Kits
199Triple Layered Mask
200Powder free Nitrile gloves
201Hand Sanitizers 500ml
202Face Shields
203PPE Kits
204Shoe Covers
205Surgical Cap
206Ecoshield
207Knee length gown (back open) disposable
208Isopropranol Lol. Grade
209Ethanol 500ml/Absolute Alcohol 95-100%
210Sodium Hypochlorite
211Nuclease free water
212Micropipette tips filtered, sterile RNase/DNase 20ul(10x96)
213Micropipette tips filtered, sterile RNase/DNase 100ul(10x96)
214Micropipette tips filtered, sterile RNase/DNase 200ul(10x96)
215Micropipette tips filtered, sterile RNase/DNase 1000ul(10x96)
216Eppendorftubes-RNase/DNase free, Free pyrogen (1.5ml) (1x500 pack size) (Size 10x96)
217Tissue Paper Roll (Size 10x96)
218Abro Tape (Size 10x96)
219Waste Disposable Bags Autoclavable-Red 30L
220Waste Disposable Bags Autoclavable-Yellow 30L
221Waste Disposable Bags Autoclavable-Yellow 15L
222Waste Disposable Bags Autoclavable-Black 30L
223Polybag ties
224Sterile Falcon Tube-15ml
225Sterile Falcon Tube-30ml
226Lyzol
22710% Hypochlorite
228Sterile Distilled water
229Baccishield (5 Ltrs.)
230Spray Bottle (5 Ltrs.)
231Spray Bottle Nozzles (5 Ltrs.)
232Discarding jars (5 Ltrs.)
233Test Tube rack stands for 15ml Falcon Tubes
234Test Tube rack stands for 50ml Falcon Tubes
235Perkin Extraction System (96x10)
236Zybio (32x10)
237Zybio (96x10)
238QIA cube HT (Catalogue no.5262)(5x96)
239Tecan (5x96)
240Thermofisher (1x96)
241easyMAG
242Master mix kit for PCR run for Covid 19 RNA
243Multichannel pipette-(1-10ul) (Size 5x96)
244Multichannel pipette-(5-50ul) (Size 1x96)
245Multichannel pipette-(30-300ul)
246Multichannel pipette-(500ul)
247Multichannel pipette-(1000ul)
248Hand Dryer machine
249Foot Operated Dustbin Yellow
250Foot Operated Dustbin Red
251Foot Operated Dustbin Black
252Cool Box for master mix
253Cooler racks for Tubes
254D Glucan Assay
255Galactomannan
256Arterial Line( Radial and Femoral) : should have following specifications- All in one arterial catheter (20G) with dart technique for easy insertion) • Integrated arterial catheter with spring wire guide. • Should have removable suture wings. • Should have catheter length of 3 cm or more • Should have guide wire length of 12 cm or more. • Shoul have introducer needle of 22G of length 8 cm or more
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail