Construction Of Human Resource Development Centre Hrdc Building At New University Campus Jammu Electric Work Construction Of Human Resource Development Centre Hrdc Building At New University Campus Jammu Electric Work, University of Jammu-Jammu And Kashmir

Government University-GU has published Construction Of Human Resource Development Centre Hrdc Building At New University Campus Jammu Electric Work Construction Of Human Resource Development Centre Hrdc Building At New University Campus Jammu Electric Work. Submission Date for this Tender is 02-11-2021. Electrification Work Tenders in University of Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

29589859
Construction Of Human Resource Development Centre Hrdc Building At New University Campus Jammu Electric Work Construction Of Human Resource Development Centre Hrdc Building At New University Campus Jammu Electric Work
Open Tender
Indian
Jammu And Kashmir
University of Jammu
02-11-2021

Tender Details

Construction Of Human Resource Development Centre Hrdc Building At New University Campus Jammu Electric Work Construction Of Human Resource Development Centre Hrdc Building At New University Campus Jammu Electric Work

Key Value

Document Fees
INR 2000 /-
EMD
Refer document
Tender Value
INR 22.25 Lakhs /-

BOQ Items

Name of Work: Construction of Human Resource Development Centre (HRDC) Building at New University Campus, University of Jammu (ELECTRIC WORK)
Sl. No. Item Description
1Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (WireMake ISI Marked Havells/Anchor/HPL/Shalimar/KEI/Polycab/Great white) (Conduit Make -ISI Marked Anchor/High Power /Finlox/National Gold/Shalimar /Ravindra) Group ‘C’
2Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (WireMake ISI Marked: Havells/ Anchor / Grandley/ L&T/HPL /Shalimar/KEI/polycab) 2 x 1.5 + 1 x 1.5 Sqmm
3-----------------------do------------------- 2 x 2.5 + 1 x 2.5 Sqmm
4------------------------do------------------2 x 6 + 1 x 6 Sqmm
5-----------------------do------------------- 4 x 4 + 2 x 4 Sqmm
6----------------------do---------------------4 x 6 + 2 x 6 Sqmm
7Supplying and fixing of 25mm dia medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required-ISI Marked Anchor/High Power /Finlox/National Gold/Shalimar /Ravindra)
8Supplying and fixing 5 amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breakersuitable for inductive load Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make Havells /Legrand /Anchor/ C&S/L&T/Siemen/IA/HPL/Standard/Wipro)
9Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
10Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required.
11Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100mm x 100mm x 60mm deep
12-----------------------do---------------------- 200mm x 125mm x 60mm deep
13Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make:Anchor/Havells /SSK/HPL)
14Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ HPL/Anchor/SSK)
15Supply & fixing 5/6 amp piano type switch on the existing switch box or cover including connection as required (Make :Havells/ HPL /Anchor /SSK )
16Supply & fixing 3 pin 5/6 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/HPL/Anchor/SSK)
17Supplying and fixing following ways and poles, plain/horizontal sheet steel MCB Distribution Board on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators) (HPL, Havells/Anchor /I.A /Legrand/Standard) 6 way 240 volts, single pole and neutral Double Door
18------------do------------- 8 way (4+24), 415 volts, three pole and neutral Double Door
19Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required.(Make Havells/ HPL /Anchor /SSK/ C&S/Great White)
20Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL /Anchor /SSK/ C&S/Great White)
21Supplying and fixing 3 pin, 5 A Ceiling Rose on the existing junction box/wooden block including connection etc. as required. (Make Havells/ HPL /Anchor /SSK/ C&S/Great White)
22Providing and fixing following rating and breaking capacity MCCB with Thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Siemens/Schreinder/ L&T/Hager /Havells/ IA/HPL/Standard/Crompton) 100 AMP 16KA TP
23-------------------do---------------------250 AMP 36 KAFP
24Supplying and fixing following types of Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Indokapp, Havells,anchor) 40 Amp 240 volts double Pole
25-------------do-------------- 63 Amp415 volts four pole
26S/F piano type Telephone socket outlet on the existing Switch Box or cover including connection as required. (Make Havells/HPL/Anchor/SSK  /C&S)
27Supplying & drawing 2 pair (0.50)sqmm FR PVC insulated annealed copper conductor un armoured telephone cables in the existing surface/recessed steel or PVC Conduit as required (Make ISI Marked Havells/ECKO/ Anchor/  Grandley /L&T/Helicab/KEI/HPL)
28Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand/Havells/Anchor/D Link/HPL/L&T) 1 run of cable
29P/F M.V danger plate of (200x150) mm made of mild steel at least 2mm thick and vitreous enameled white on both side and with inscription in single red colour on front side as reqd.
30Laying of one number PVC Insulated and PVC sheathed/XLPE power cable 1.1 KV grade of following size on wall surface as reqd. Upto 35 sq mm (clamped with 1mm thick saddle).
31-----do-----Above 95 sqmm and upto 185 sq mm (clamped with 25x3mm M.S Flat Clamp)
32Supply/Installation testing and commissioning of following type of surface /recessed mounted Indoor Linear/square or round downlighter/wall bracket/bulk head, environmental friendly energy efficient LED Light fittings complete. Make (Halonix/ Havells/ Syska/Bajaj/Greatwhite/ Philips/Crompt-on/compact) 4 feet 18 to 22 watt, 230 volts LED batten type tube light fitting complete.
33----do----12 To 18 Watt LED recessed / Surfacemounting down, 6500 K, 240 Volts as per cat: GARNET Slim Panel Light square/ Round 900 to 1200mm dimension complete.
34----do----Wall Brackets fittings as per Cat. No HLWB-01-B22 Suitable for 15-20 watt LED Bulb including the cost of Bulb.
35----do-----Bulk Head as per cat HLBH-02-10-CW suitable for 10-15 watt LED Bulb including the cost of Bulb.
36Supply/installation, testing and commisioning of the following type of outdoor LED type bollard light/ floodlight /Street lights/post light luminaries complete with all accessories.Make (Bajaj/Legrand /Surya /Havells/ C&S/ compact) 45 to 60 watt,230 volts IP 66/ IP 65
37Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/insulated conductors/strips etc. The panel shall be fabricated out of CRCA not less than 2.00 mm thick for the load bearing members and 1.6mm for doors of L.T Panels. The frame work may be Agle Iron/Channel/Bolted type construction should be arrangement for I/C/O/G. Cable termination with 2 Each. 20x5mm cu. Strip fixed all around the panel connected to 2 Each. earth bars cu-strips connected to incoming earth conductor.(Make Electric Field/ Bharti Engineers/Gupta & Friends/ Semon) MAIN OUTDOOR /BUILDING CONTROL PANEL a. INCOMING Space for 1 No. 300 Amp TPN Al. Bus bar of equal cross section for Main Power connection to Main MCCB. Space for 1 No. 250 Amp 4 pole MCCB of 35KA Space for 1 no. 3-phasedigital type energy meter. b.INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT"s. ii.Voltmeter of required range with VSS. c.OUTGOING Space for1 No. 300 Amp TPN Al. Bus bar of equal cross section for power load/light load of building Dimension2’x2’x1’6”
38MAIN NORMAL CUM EMRENGECY PANEL a. INCOMING Space for 1 No. 250,4 pole Ampmain MCCB Space for 1 No. 200 Amp4 pole change over switch b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT"s. ii.Voltmeter of required range with VSS. c. BUS BAR Space for 1 No. 300 Amp TPN Al. Bus bar of equal cross section for power load with provision/space for 10 nos 40 amp double pole isolator for AC system. Space for 1 No. 300 Amp TPN Bus bar of equal cross section for liht load. d. OUTGOING Space for minimum 05 No. and 100 Amp 4 pole MCCB for power and light loadand lift load. Dimension 5’x 5’ x 1’-6”
39Supply, testing and commissioning of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPECable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make Havells /CCI/ Grandley /Finlox /Plaza / General /Polycab/Gloster) 2 core 6 sq mm armoured cable
40--------------------------do------------------------3 ½ core 120 sq mm armoured cable
41Supply, installation, testing, commissioningof 1200 mm sweep ceiling fans complete with blades with new BEE star rating affixed on the body of the fan and as per IS 374 2019 driven by squirrel cage induction motor capacitor type energy efficient brushless with minimum air delivery of 210 meter cube/minutes (3 to 5 new BEE Star rating) to be approved by Engineer Incharge before Installation. Make (Havells,Orient,Anchor,compact,Bajaj)
42Supply, installation, testing, commissioning of 300 mm sweep Exhaust fan with new BEE 3 to 5 star rating to be approved by incharge engineer before installation.(Make Havells,Orient,Anchor,compact,Bajaj)
43P/F following rating 230 volts energy saver LED Lamps. (MakePhilip /Havells/Bajaj/ Surya/ /Crompton/ Wipro/compact) 8 to12 watt LED lamp
44Supply & installation of CAT 6 2 module toll lessinformation outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required. (Make Legrand/Delton/Systemax /Penuit/ Havells/HPL/Anchor)
45Supply and installation of Singlex Face Plates along with clearly printed labels and holders complete as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T/G.E)
46Supply & fixing of 20mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd.
47P/laying of 100 mm dia heavy duty PVC pipe in ground including digging the pit and refilling complete job. (prince/supreme/Astral/Uniplas)
48Supply and fixing of onload I-O-II Four pole with advanced neutral change over switch. (Make Legrand/ I.A/Havells /Siemen/HPL) 200 Amp 4Pole,415 volts
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail