| Sl. No. | Item Description |
| 1 | Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/ loose soil, for laying of under ground electric cable, pipes etc all as directed and specified.Note:(i)Authorised width & depth shall only be excavated, measured and paid as specified in clause 3.2.3 of SSR part II and 19.74.1 of SSR part I for cable/pipe laying portion.(ii)Serviceable PCC /RCC cable cover obtained during excavation shall be stackedseparately carefully without any extra cost to the Deptt. |
| 2 | Taking out old unserviceable LT cable of any size any type from trench/duct/ poles / roof/pipe etc and keeping aside for segregation of serviceability. Serviceable cable will be re-laid at same place or other place as required. |
| 3 | Supply and laying, connecting XLPE insulated, armoured, heavy duty electric cable multi stranded aluminum conductors, 1100V grade, of size 16 Sqmm 4core with proper size of lugs and laid in trenches / ducts / through GI pipe / fixed to poles etc complete all as specified and directed by Engr-in-Charge.Note:Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately under relevant item. |
| 4 | All as per item No 3.00 above but of size 35 Sqmm 3.5 core |
| 5 | All as per item No 5.00 above but of size 70 Sqmm 3.5 core |
| 6 | All as per item No 6.00 above but of size 95 Sqmm 3.5 core |
| 7 | Re-laying of old serviceable cable of any size obtained from item above.Note:Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately under relevant item. |
| 8 | M & L for river bed sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed |
| 9 | Laying onlyserviceable un-reinforced precast concrete cable coverclass LV, Type 1, flat, of250 mm x 150 mm x 40 mm obtainedfrom trenches, abetting each other with gap between adjacent slab not exceeding10 mm over under cable for protection complete all as directed. |
| 10 | Supply & laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding10mm over under cable for protection. |
| 11 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed. |
| 12 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 13 | M& L for cutting under the road /pavement /hard standing or in any other situation withthe manual labour for crossing of U/G cable through it and makingboth the endgood complete all as specified and directed . |
| 14 | Supply and laying GI water tubing of 80 mm bore, light grade, IS-1239 marked with all fittings IS marked and laid in trenches/under roads/in drains with suitable size flat iron/GI clamps, bolts, nuts and washers etc for cable protection, complete all as specified. |
| 15 | Supply and laying GI water tubing of 50 mm bore, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads/in drains, fixed to poles/walls with suitable size flat iron/GI clamps, bolts, nuts and washers etc for cable protection, complete all as specified and as directed. |
| 16 | Supply and laying GI water tubing of 40 mm bore, light grade, IS-1239 marked with all fittings IS marked and laid in trenches/under roads/in drains with suitable size flat iron/GI clamps, bolts, nuts and washers etc for cable protection, complete all as specified. |
| 17 | Supply, fixing and testing LT cable jointing kitstraight through heat shrinkable type suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100V grade LT cable of size 3.5/4 core 16 to 50 sqmm complete all as directed. |
| 18 | Supply, fixing and testing LT cable jointing kit straight through heat shrinkable type suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100V grade LT cable of size 3.5/4 core 70 to 150 sqmm complete all as directed. |
| 19 | Supply, fixing and testing LT cable jointing kit straight through heat shrinkable type suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100V grade LT cable of size 3.5/4 core 185 to 300 sqmm complete all as directed. |
| 20 | Dismantling concrete poles/ struts, any size any type all as directed |
| 21 | Supply & erect Prestressed concrete pole, 9.0 metreslong, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complete all as specified and as directed. Note : Excavation, earth work and PCC shall be measured and paid separately under relevant item. |
| 22 | M&L for Cement concrete in pole foundations, coping, filling and mass concrete, type C2 1:4:8 with 40mm graded stone aggregate including dismantling old PCC etc |
| 23 | M&L for Cement concrete in pole foundations, coping, filling and mass concrete, type C2 1:3:6 with 40mm graded stone aggregate including dismantling old PCC etc |
| 24 | Taking downold ACSR conductor including guard wire, GI earth wire, Stay wire and insulators of any size from existing poles etc complete all as directed. |
| 25 | Restretching/ tightening of ACSR conductor of any type and size by disconnectingfrom insulators from any location complete all as directed. Note:- (i) Proper shut down has to be taken from MES. (ii)T & P i.e. Ladder, safety items,or any other equipment for repair tightening of ACSR conductor shall be provided by Contractor and cost for the same deemed to be included in respective items |
| 26 | Supply & fixing of MS CRCA sheet enclosure of 2mmsheet thicknessduly painted, fixing arrangement for housing MCCB including supply and fixing MCCB of capacity 63 Amps, 10KA4 pole, 415 volts with fixed thermal & magnetic settings including & connections of cables withthimbles/lugs and to existing DB etc complete all as directed. |
| 27 | Supply & fixing of MS CRCA sheet enclosure of 2mmsheet thicknessduly painted, fixing arrangement for housing MCCB including supply and fixing MCCB of capacity 100 Amps, 16KA4 pole, 415 volts with fixed thermal & magnetic settings including & connections of cables withthimbles/lugs and to existing DB etc complete all as directed. |
| 28 | Supply & fixing of MS CRCA sheet enclosure of 2mmsheet thickness duly painted, fixing arrangement for housing MCCB including supply and fixing MCCB of capacity 160 Amps, 25KA4 pole, 415 volts with fixed thermal & magnetic settings including & connections of cables withthimbles/lugs and to existing DB etc complete all as directed |
| 29 | Supply & fixing of MS CRCA sheet enclosure of 2mmsheet thickness duly painted, fixing arrangement for housing MCCB including supply and fixing MCCB of capacity 200 Amps, 25KA4 pole, 415 volts with fixed thermal & magnetic settings including & connections of cables withthimbles/lugs and to existing DB etc complete all as directed |
| 30 | S&F in replacement for kiosk box for luminaries, weather proof made out of PVC/HDPE /FRP housing fire retardant, non fusing, shock & rust proof, single piece molded andcover with hinged door, pole mounting type comprising of aluminum TPNbus bar of 60 Amps of minimum size 300x250x150mm, fixed on pole with MS, clamps 30x5mm with necessary nuts, washer complete all as directed. Note. Rate of TPN bus bar and MS clamp inclusive in item rate |
| 31 | S&F in repair service wire 1100 volts grade PVC insulated PVC unsheathed cable multi strandedcopper conductor of size 0.75 sqmm 3 core complete all as specified |
| 32 | S&F sintex box of size 450mm x 375mm x 200mm made out of poly carbonate IP-65 protection with poly ethelene gasket and glow wire tested at 960 degree celcius as per IEC 60695-2-11 and thermoplastic gland of suitable size fixed on poles with galvanised clamps (02 Nos on each pole) of F1, 40x5mm made to shape fixed with nut bolts washers etc. Make Sintex or equivalent complete all as specified and directed with following fitments :- (a) Aluminum bus bar of 100Amps capacity fixed on porcelene insulators and insulated with colour sleeves (04 Nos) and connect suitable for 25Sqmm to 35Sqmm cableNote : Cost of clampsand bus bar strips is inclussive in quoted rate |
| 33 | S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 volts grade complete all as specified and as drected |
| 34 | S&F Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, 1100 volt grade of size 75 mm height and 90mm dia complete all as specified. |
| 35 | S&F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified. |
| 36 | S&F spacers/separator PVC with clamping nut bolts suitable for 2 wire |
| 37 | S&F spacers/separator PVC with clamping nut bolts suitable for 3 wire |
| 38 | S&F spacers/separator PVC with clamping nut bolts suitable for 4/5 wire |
| 39 | Supply and fixmaintenancefree solardeep cycle batteries designed for long time back up of capacitry 12 volt 65 AH. |
| 40 | Supply and fixmono/polycrystalline MNRE approved solar panels for solar lights of capacity 20 watt12 volts suitable for 20 watt solar lights |
| 41 | Supply and fixsolar lights 20 watt with all accessories suitable forsolar panels for solar panelsof capacity 20 watt with white lights complete |
| 42 | M & L for earthingcomplete with galvanized steel earth plate electrode60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate . Earth plate surrounded by 15 cm thick packed layers of charcoal dust and common saltupto 1.5 meter depth all around the earth plate and connected to earth lead of GI strip 32x6 mmby means of bolts, nuts, check nuts and washers of galvanised iron or steel and thimbles and other end of the earth wire connected to Plant/equipment and protected by galvanized iron or steel pipe light grade and water pipe 20mm bore GI medium grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of2009 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronze size 75x75x25 mm complete . Note :On testing after completion of earthing if desired earth resistance below 5 ohms is not achieved , the earthing will be redone at no extra cost. |
| 43 | Supply, installing, testing and commissioning, factory made LTfeeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron base frame work,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door and locking arrangement and including earth work, disconnecting old connections and taking out oldpanel and reconnecting new panel etc. The panel consisting of the following:- (a)Aluminumbus barfour strips250 Amps ,415 volts, fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set.(b)MCCB,04 Pole, 160 Amps with breaking capacity Icu- 16 KA - 01 No (Incoming)(c)MCCB,04 Pole, 63 Amps with breaking capacity 10 KA- 05 Nos(d) Volt meter 0-500 volt with coil and selector switch - 1No.(e)Ammeter 0-500 Amps with CT coil and selector switch - 01 No (f) Indication lamps R,Y,BLEDtype– 1 set of 3 (g) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, cemented block/brick work in CM 1:6 with sub class `B\", old sizebricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 30cmabove and 15 Cm below the groundlevel. |
| 44 | Supply, installing, testing and commissioning, factory made and tested LTfeeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron base frame work,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door and locking arrangement and including earth work, disconnecting old connections and taking out oldpanel and reconnecting new panel etc. The panel consisting of the following:- (a)Aluminumbus barfour strips400 Amps ,415 volts, fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set.(b)MCCB 04 Pole, 250 Amps with breaking capacity 35 KA - 01 No (Incoming) (d)MCCB,04 Pole, 63 Amps with breaking capacity 10 KA - 05Nos(e)Digital Volt meter 0-500 volt with coil and selector switch - 1 No.(f) Digital ammeter 0-500Amps with CT coil and selector switch - 01 No(g) Indication lamps R,Y,BLEDtype– 1 set of three (j) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s.(k) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, cemented block/brick work in CM 1:6 with sub class `B\", old sizebricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 30cmaboveand 15 Cm below the groundlevel. |
| 45 | Supply, installing, testing and commissioning, factory made and tested LTfeeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron base frame work,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door and locking arrangement and including earth work, disconnecting old connections and taking out oldpanel and reconnecting new panel etc. The panel consisting of the following:- (a)Aluminumbus barfour strips525 Amps ,415 volts, fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set.(b)MCCB,04 Pole, 400 Amps with ultimate breaking capacity 45 KA - 01 No(Incoming) (c) MCCB,04 Pole, 160 Amps with breaking capacity 16 KA - 02 Nos(d) MCCB,04 Pole, 63 Amps with breaking capacity 10 KA - 05Nos(e) MCCB,04 Pole, 40 Amps with breaking capacity 10 KA - 01Nos(e) Digital Volt meter 0-500 volt with coil and selector switch - 1 No.(f)Digital ammeter 0-500Amps with CT coil and selector switch - 01 No(g)Indication lamps R,Y,BLEDtype– 1 set of three (j) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCB\"s.(k) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, cemented block/brick work in CM 1:6 with sub class `B\", old sizebricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 30cmaboveand 15 Cm below the groundlevel. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender