Electrification Of Govt. Up School Paappinissery Electrification
Tender Value
4.65 Lakhs
Estimated cost
Bid Submission
23 Oct 2021
0 days left
EMD
6980
Bank guarantee accepted
Document Fee
931
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
pappinisseri → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Electrification Of Govt. Up School Paappinissery Electrification
BOQ
| Sl. No. | Item Description |
| 1 | building maintenance |
| 2 | Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FR PVC insulated stranded single core copper conductor cable 650V grade, including providingSwitch Boardmain and continuous earthing with No. 14 SWG copper, required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white)etc. up to and including 6 A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB\"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single control light point with 6A, 3 plate ceiling rose |
| 3 | Single control light point without ceiling rose. |
| 4 | Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. |
| 5 | Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points. |
| 6 | Independent plug |
| 7 | Supply conveyance, installation, testing and commissioning the following types oflight fittingsmade from CRCA sheet 0.5mm thickness with all accessories andlamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copperconductor flex wire or extending the original wiring and giving connections as required1200mm 16/20 W LED lamp with box type fixture |
| 8 | Supply and fixing angle / straight brass lined skirt type, bakelitebatten holder without shade and giving connection etc as required |
| 9 | Supply and fixing 200 mm Plastic sill shade on existing batten / pendent/bracket fittings as required |
| 10 | Supply and providing 7/5 Watta LED Bulb in the existing fittings as required |
| 11 | Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 12 | Supply, fabrication, conveyance and fixing 25 mm dia with HG company fabricated clamps of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings). |
| 13 | Supply and installation of suitable size rod type fan clamp as per IS 732 as required. |
| 14 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizesusing standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200 mm sweep (Category B)- |
| 15 | Charges for cutting holes suitable for accommodating exhaust fans of sizes up to 305 mm sweep including plastering, colour washing etc. as required. |
| 16 | Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.305 mm, single phase, light duty, 900 rpm exhaust fan in metal frame |
| 17 | Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiringand making good the surface as required. |
| 18 | Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in recess withfront plate including making good the damages, colour washing etc as required (Group B)1/2 module metal box in recess with front plate ( for projector.) |
| 19 | 3 module metal box in recess with front plate (for Power Plug ) |
| 20 | 8 module metal box in recess with front plate (for 3 x 6 A set of plug) |
| 21 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (Group B)6 A SP 1 way switch |
| 22 | 6A 3 pin shuttered socket |
| 23 | 16 A SP 1 way switch with indicator |
| 24 | 6 / 16 A combined socket |
| 25 | 20 A DP switch with ind |
| 26 | 25 / 32 A socket |
| 27 | Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on recess/surface including making good the damages etc as required. 20 mm dia light gauge (Plug & Internet) |
| 28 | 25 mm dia light gauge |
| 29 | Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 1.50 sq mm 3 run |
| 30 | 1.50 sq mm 5 run |
| 31 | 2.50 sq mm 3 run |
| 32 | 4.00 sq mm 2 run + 2.5 sq mm 1 run |
| 33 | 4.00 sq mm 4 run |
| 34 | Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way single phase double cover (IP 42/43) |
| 35 | 6 way (8+18) -double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 36 | Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required 40 A, double pole,mini break isolator |
| 37 | 63 A four pole mini break isolator |
| 38 | 32 A, 10 kA, DP MCB (C curve) |
| 39 | 40 A,2 pole, 30 mA RCCB |
| 40 | 63 A,4 pole, 1000 mA RCCB |
| 41 | 6 A to 32 A, 10 kA, SP MCB (C curve) |
| 42 | 50 A and 63 A, 10 kA, TP MCB |
| 43 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required.2.00 mm copper conductor (14 SWG) |
| 44 | 2.65 mm copper conductor (12 SWG) |
| 45 | 3.15 mm copper conductor (10 SWG) |
| 46 | supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.2.00 mm (14 SWG) |
| 47 | 2.65 mm (12 SWG) |
| 48 | 3.15 mm (10 SWG) |
| 49 | Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 12 x 3 mm brass bolt & nut |
| 50 | 25 x 3mm brass bolt & nut |
| 51 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 52 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 10 sq mm with factory made clamp |
| 53 | Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 50 / 38 mm or nearest size |
| 54 | Supplying siemens / tropodur type nickel plated Double compression brass cable gland with earth clamp and aluminium socketfor PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required.10 sq mm |
| 55 | Fabrication, supply & installation of dust and vermin proof,wall mounting,thermoplastic meter boxof folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. 600x300x270mm |
| 56 | 63 A fuse holder with BS type offset tag fuses. |
| 57 | 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base. |
| 58 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc with charcoal/ coke and salt as required. |
| 59 | Supply and providing test joint for the earthing system using 2 x 25 x 3 mm GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. |
| 60 | Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. |
| 61 | Supplying and fixing 63 A, TPN Switch Disconnector Fuse Unit (Sheet steel enclosure) and giving connection as required |
| 62 | Supply & Providing 63 A, HRC fuse link with fuse base. |
| 63 | 63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base. |
| 64 | Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height |
| 65 | 90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 66 | 9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.4 X 25 sq. mm (28mm) |
AI Tender Summary
Tender Timeline
Oct 16, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedOct 23, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 25, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender