Repair And Improvement Ei And Fans In Sdmc Community Center At Begumpur Hauz Khas Ward No. 62 S Under South Zone Repair And Improvement Ei And Fans In Sdmc Community Center At Begumpur Hauz Khas Ward No. 62 S Under South Zone, BEGUMPUR HAUZ KHAS-Delhi

Municipal Corporation-MC has published Repair And Improvement Ei And Fans In Sdmc Community Center At Begumpur Hauz Khas Ward No. 62 S Under South Zone Repair And Improvement Ei And Fans In Sdmc Community Center At Begumpur Hauz Khas Ward No. 62 S Under South Zone. Submission Date for this Tender is 21-10-2021. Electrical Maintenance Tenders in BEGUMPUR HAUZ KHAS Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

29568298
Repair And Improvement Ei And Fans In Sdmc Community Center At Begumpur Hauz Khas Ward No. 62 S Under South Zone Repair And Improvement Ei And Fans In Sdmc Community Center At Begumpur Hauz Khas Ward No. 62 S Under South Zone
Open Tender
Indian
Delhi
BEGUMPUR HAUZ KHAS
21-10-2021

Tender Details

Repair And Improvement Ei And Fans In Sdmc Community Center At Begumpur Hauz Khas Ward No. 62 S Under South Zone Repair And Improvement Ei And Fans In Sdmc Community Center At Begumpur Hauz Khas Ward No. 62 S Under South Zone

Key Value

Document Fees
INR 500 /-
EMD
INR 7213.0 /-
Tender Value
INR 2.40 Lakhs /-

BOQ Items

Name of Work: Repair and Improvement EI and fans in SDMC community center at begumpur hauz khasward no. 62 S under south zone
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. as required. Group C
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
3Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 1.23.1 5/6 amps switch
4Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
63 x 4 sq. mm
73 x 6 sq. Mm
8Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
9Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 Amp, 16 KA,TPMCCB
10100 amp,16KA,TPMCCB
11125 Amps,16KA,TPMCCB
12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole Single Pole
13Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. B) 63 A
14Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) a) 12 Way Double Door
15b) 8 way double door
16SITC OF LED Tube type luminarie 20 watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:a) Total system wattage 20watt+/-5% (b)Luminious efficiancy lumens/watt>=95(c) Power factor>=.95
17SITC OF surface mounting CRCA housing 36W LED luminarie with acrylic cover diffuser with following specifications including fixing on existing wall/surface with connection as reqd:a) Total system wattage 36watt+/-5% (b)Luminious efficiancy >=95lumens/watt(c) Power factor>=.95
18Supply,installation,testing & commissioning of single / three phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtr. suction and delivery 25X25 mm.
19Installation of exhaust fan in the existing opening ,including making good the damage, connection, testing ,commissioning etc.as requiredUp to 450 mm sweep
20Supply of 12"" ( 300 mm )sweep 1400 RPM exhaust fan heavy duty complete with shutter,blade etc as required.
21Supply,Installation,testing and commissioning of 1200mm sweep BEE 5star rated,ceiling fan with brush less Direct current(BLDC) Motor,class of insulation:B,3 nos blades,30cm Long down rod,2 nos canopies,shackle kit,safety rope,copper winding,power factor not less 0.9,service value(CMM/W) minimum 6.85,air delivery minimum 215CMM,350 RPM(tolerance as per IS:374-2019),THD less than 10%,remotte or electronic regulator unit for speed control and all remaining accessories including,safety pin,nut bolts,washers,temperature rise=75 degree C(Max),insulation resistance more than 2 mega Ohm,suitable for 230V,50Hz,Single phase Ac supply,earthing etc.complete as required
22Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
23Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
24Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required
25Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
26Supply of XLPE insulated and PVC Sheathed AL Conductor armoured 1.1KV gradeconfirming to IS: 7098of following sizes:2 x 16 sqmm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy