}

Supply Of Items -1. Supply Installation, Testing & Commissioning Of Modular Type Variable Refrigerant Flow/Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling And Heating, Having All Hermetically Sealed Inverter Type Scroll Co, Patna-Bihar

Indira Gandhi Institute Of Medical Sciences-IGIMS has published Supply Of Items -1. Supply Installation, Testing & Commissioning Of Modular Type Variable Refrigerant Flow/Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling And Heating, Having All Hermetically Sealed Inverter Type Scroll Co. Submission Date for this Tender is 18-10-2021. Spare Part Tenders in Patna Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

29552178
Supply Of Items -1. Supply Installation, Testing & Commissioning Of Modular Type Variable Refrigerant Flow/Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling And Heating, Having All Hermetically Sealed Inverter Type Scroll Co
Open Tender
Indian
Bihar
Patna
18-10-2021

Tender Details

Supply Of Items -1. Supply Installation, Testing & Commissioning Of Modular Type Variable Refrigerant Flow/Variable Refrigerant Volume Air Cooled Outdoor Units Suitable For Cooling And Heating, Having All Hermetically Sealed Inverter Type Scroll Compressor(S), Minimum Two Compressors For Above 14 Hp Modules, Microprocessor Based Controller, Top Discharge Type Condensing Unit(S), With R 410 A Refrigerant, Vibration Isolators, With Suitable Foundation Etc. Complete As Required. The Unit Shall Deliver The Rated Capacity At Ahri Conditions And Work Even At 50°C Ambient Temperature Without Tripping. The Unit Shall Be Suitable To Work On 400V +/- 10%,3 Phase, 50Hz Ac Power Supply. The Unit Shall Be Filled With First Charge Of The Refrigerant And Ready For Use As Required. The Cop At Ahri Conditions Shall Not Be Less Than 3.1 And Ieer Not Less Than 6.5. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric Or Equivalent. INDOOR UNIT-CASSETTE TYPE -2. Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree CWB temperature. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric or equivalent-a) 0.8 TR b) 1 TR c) 1.2 TR d) 1.6 TR e) 2 TR f) 2.4 TR g) 2.8TR h) 3.2 TR i) 3.6 TR j) 4 TR k) 4.8TR -INDOOR UNIT-HIGH WALL TYPE- 3. Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27Degree C DB and 19 Degree C WB temperature. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric or equivalent -a) 0.6 TR b) 0.8 TR c) 1 TR d) 1.3 TR e) 1.45 TR f) 1.65 TR g) 2 TR h) 2.4TR i) 3.2 TR j) 4.8TR -INDOOR UNIT-DUCTABLE TYPE -4. Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric or equivalent - 1) Low static ductable units (minimum 25 Pascal external static pressure) -a) 0.6TR b) 0.7 TR c) 0.8 TR d) 0.9 TR e) 1 TR f) 1.1 TR g) 1.3 TR h) 1.4 TR i) 1.6 TR -2) Mid Static Ductable units (minimum 45 Pascal external static pressure)- 1.8TR 2 TR 2.3 TR 2.6TR 2.8TR 3.4TR 4TR -3) High Static Ductable units (minimum 110 Pascal external static pressure) -5.5TR 7.1TR 8TR -COPEER REFRIGERANT PIPING -5. Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :a) 6.4 mm dia. (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation b) 9.5 mm dia. (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation c) 12.7 mm dia. (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation d) 15.86 mm dia. (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulation e) 19 mm dia. (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation f) 22.2 mm dia. (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation g) 25.4 mm dia. (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation h) 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation i) 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19mm thick insulation j) 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19mm thick insulation k) 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19mm thick insulation l) 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19mm thick insulation 6 Supply , installation, testing & commissioning of control cum transmission wiring of 2 core X 1.5 sq mm copper in suitable PVC conduits for interconnection between IDUs & ODUs. 7 Supply and commissioning of rigid PVC drain pipe with fitting proper support at 5 feet interval and insulated with 6mm thick closed cell nitrile rubber insulation a) 25 mm b) 32 mm 8 Supply and toping up of additional refrigerant (R-410) 9 Supply of pair of Indoor & Outdoor refnet joints Y-Type. 10 Supply of codeless remote controller along with receiver kit for VRF units. 11 Central Controller for Indoor & Outdoor Units- Touch Screen Type. Supply, installation, testing & commissioning of Central Controller capable of controlling of all IDUs ( Minimum 32 Group), ODUs ( Minimum 64 Nos.) complete with necessary hardware, accessories etc. to perform the following functions: Control of IDUs, ODUs Units as above with monitoring of vital parameters such as temperature sensing & setting, ON/OFF, status etc. Permit / prohibit function of each remote controlled unit, , Operation of units in individually or in group, Fault indication with Alarm scheduling of units.. The central controller will be complete including all hardware & software (including wiring) suitable to perform above function. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric or equivalent 11 Under deck thermocal insulation of 50mm. 12 Nitrile Insulation for duct of 9mm 13 Nitrile Insulation for copper pipes of 13 mm 14 Nitrile Insulation for copper pipes of 19 mm 15 Comprehensive Annual Maintenance (including battery) of 3-phase online UPS installed at IGIMS, Patna-14. 15 Rectification of one no 3-phase 60 KVA, online UPS installed at IGIMS, Patna-14 16 Rectification of one no 3-phase 120 KVA, online UPS installed at IGIMS, Patna-14 17 Comprehensive Annual Maintenance of 3-phase Servo Voltage stabilizer of 100 KVA installed at IGIMS, Patna-14. 18 Rectification of 3-phase 3- phase Servo Voltage stabilizer of 100 KVA installed at IGIMS, Patna-14. 18 Comprehensive Annual Maintenance of 3-phase 250 amp phase sequence corrector installed at IGIMS, Patna-14. 19 Comprehensive Annual Maintenance of 3-phase 400 amp phase sequence corrector installed at IGIMS, Patna-14. 20 Rectification of 3-phase 400 amp phase sequence corrector installed at IGIMS, Patna-14. 21 Rectification of 3-phase 250 amp phase sequence corrector installed at IGIMS, Patna-14. 22 Supply of split type 1.5TR, 240 volts air-conditioner. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric or equivalent 23 Supply of split type 2 TR, 240 volts air-conditioner. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric or equivalent 24 Supply of window type 1.5TR, 240 volts air-conditioner. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric or equivalent 25 Supply of window type 2TR, 240 volts air-conditioner. Make - Hitachi / Daikin/ O General / Carrier / Mitsubishi Heavy/ Mitsubishi Electric or equivalent 26 SITC of 4KVA voltage stabilizer input voltage 160-270 volts, output 220 volts with time delay. Make- LIV Guard/ V-Guard/ Voltas or equivalent. 27 SITC of 5KVA voltage stabilizer input voltage 160-270 volts, output 220 volts with time delay. Make- LIV Guard/ V-Guard/ Voltas or equivalent. 28 SITC of 450 mm, 230 Volt. AC wall/ cabin fan including fixing the bracket & aluminum body making connection, testing, commissioning etc. as required. Make- Havells / Crompton / Bajaj / Khetan / Orient or equivalent.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail