Public Administrative Department Government Departments Closing in 0 days TDR #29549202

Dp Kkd 2021-22 Nadammalpoyil Matholath Kadavu Road Omassery Road

Issued by Government Departments · Omassery, Kerala
Tender Value
27.02 Lakhs
Estimated cost
Bid Submission
20 Oct 2021
0 days left
EMD
40600
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Omassery → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Dp Kkd 2021-22 Nadammalpoyil Matholath Kadavu Road Omassery Road

BOQ

Work Name:DP KKD 2021-22 Nadammalpoyil Matholathu kadavu road Omassery pt
Sl. No. Item Description
1RE-TARRING
23.2 : Preparation of Foundation for EmbankmentScarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical MeansScarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
3od1295664/2021_2022 : (Filling with quarrymuck)<br>Filling up low lying and water logged areas with local material/quarrymuck spreading in layers, leveling the top at sit and consolidated by ramming, etc complete for improving the CBR value of subgrade (Details of cost for 300 cum)
44.1.A.1 : Granular Sub-base with Well Graded Material (Table 400.1)
(A) By Mix in Place Method
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with smoothwheelroller to achieve thedesired density, complete as per Technical Specification Clause 401.
(i) For Grading I Material
54.9 : Wet Mix Macadam
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
By Mechanical Means with 1 km lead
675.5.1.1pb : Prime Coat - Low porosity - With Packed Bitumen Rates
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
775.5.5.A.1pb : Modified Penetration Macadam 50 mm thick using Bitumen S-65 - Packed Bitumen Rates
Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.
875.5.5.B.2pb : Modified Penetration Macadam 75 mm thick using Bitumen S-65 - Packed Bitumen Rates
Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.
975.5.2.1pb : Tack Coat - With Packed Bitumen Rates
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
1075.5.2.3pb : Tack Coat - With Packed Bitumen Rates
Providing and applying tack coat with Bitumen emulsion (RS-1)using emulsiondistributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
1175.5.9.1.2pb : 20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder - Bitumen S-65 - Packed Bitumen Rates
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.
Case - I ByManual Means
(II) Bitumen (S-65)
1275.5.12.A.3.2pb : Seal Coat - Manual Means - Type C - Bitumen S-65 - Packed Bitumen Rates
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510
A. By Manual Means
CaseIII :Type C
(II) Bitumen (S-65)
1311.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.I.Ordinary soil(i)Upto 3 m depth
14od1309545/2021_2022 : Dry Rubble Masonry-Dry rubble with out concrete levelling course masonry with<br>good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all<br>materials labour charge etc , complete as per direction<br>
1512.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
1612.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
1712.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
1875.8.1 : Providing Plain cement concrete for road work CC 1:2:4 (1 cement: 2 fine aggregate: 4course aggregate) laid to required slope and camber in panels (@ 3 m c/c) as requiredincluding compaction, finishing and tamping etc .complete. Max. size of courseaggregate not exceeding 25mm , mixed in concrete mixer etc complete as perspecification (i) Nominal mix (1:2:4)

AI Tender Summary

OUR REF NO 29549202
AUTHORITY Government Departments
TENDER VALUE 27.02 Lakhs
LAST DATE 20-10-2021
Authority
Authority Name Local Self Government Department
Work Description Dp Kkd 2021-22 Nadammalpoyil Matholath Kadavu Road Omassery Road
Basic Detail
Tender No TA/LSGD/KKD/116/2021-22
Bidding Type Tender
Location
City Omassery
State Kerala
Key Dates
Publish Date 13 Oct 2021
Submission Date 20 Oct 2021
Open Date 22 Oct 2021
Finance
Tender Value 27.02 Lakhs
Tender Fee 2760
EMD 40600
Exemption Not Available
Document List
db087db7-5ac5-4d48-bb15-c1fd8d86c449.html
additionaltenderconditions.pdf
BOQ_633721.xls
Form8384.pdf
prel.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 20, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 22, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

db087db7-5ac5-4d48-bb15-c1fd8d86c449.html

pdf

additionaltenderconditions.pdf

xls

BOQ_633721.xls

pdf

Form8384.pdf

pdf

prel.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders