Bridges Construction Of 28 Meter 4 Span Of 7 Meter At construction / 5 Year Maintenance Of Bridge In Km. 4+080 On Borgaon ( G ) To Susund Hetiroad Taluka Karanja District Wardha Package No: War-Adb-Br-09

Tender Notice

29545431
Bridges Construction Of 28 Meter 4 Span Of 7 Meter At construction / 5 Year Maintenance Of Bridge In Km. 4+080 On Borgaon ( G ) To Susund Hetiroad Taluka Karanja District Wardha Package No: War-Adb-Br-09
Indian
Maharashtra
12-10-2021
02-11-2021
08-11-2021

Tender Details

Bridges Construction Of 28 Meter 4 Span Of 7 Meter At construction / 5 Year Maintenance Of Bridge In Km. 4+080 On Borgaon ( G ) To Susund Hetiroad Taluka Karanja District Wardha Package No: War-Adb-Br-09

Key Value

Document Fees
INR 11200 /-
EMD
INR 101000.00 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
68ad7518-db02-46ad-a69f-a4e47d594d48.html Tender Notice 43.6 KB
BOQ_1255256.xls Tender Document 331.0 KB
KARANJAADB-BR-09.pdf Tender Document 1.8 MB
Tendernotice_1.pdf Tender Document 54.1 KB

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

NAME OF WORK :Bridges Construction of 28 meter 4 span of 7 Meter atCONSTRUCTION / 5 YEAR MAINTENANCE OF BRIDGE IN KM. 4+080 ON BORGAON(G) TO SUSUND HETIROAD TALUKA KARANJA DISTRICT WARDHA Package No: WAR-ADB-BR-09
Sl. No. Item Description
1CONSTRUCTION / 5 YEAR MAINTENANCE OF BRIDGE IN KM.4+080 ONBORGAON (G) TO SUSUND HETIROAD TALUKA KARANJA DISTRICT WARDHA
2Bill No. 1 Bridge work foundation
3Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and leadas per Technical Specification Clause 202
4Removing all types of Hume pipes and stacking within a lead and lift including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202.
5Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto all lead , dressing of sides and bottom and backfilling in trenches with excavated suitable material. I)Ordinary soil [ (I) Up to 3 m depth ]
6Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto all lead , dressing of sides and bottom and backfilling in trenches with excavated suitable material. II)Ordinary Rock (Not Required Blasting)
7Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto all lead , dressing of sides and bottom and backfilling in trenches with excavated suitable material.IV] Hard rock (Requiring blasting)
8Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required.A1)For Abutment
9Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required.A2) For Pier
10Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as requiredA3) For Returns
11Filling annular space around footing in rock as per technical specification Clause 1203.4.3.(Using 43 Grade OPC CementM-15)
12Providing & placing concrete for plain/reinforced concrete M-15 in open foundations complete as per drawing and Technical Specification Clauses 802,803,1202 and 1203.(Using 43 Grade OPC Cement)
13Providing & placing concrete for plain/reinforced concrete M-20 in open foundations complete as per drawing and Technical Specification Clauses 802,803,1202 and 1203.(Using 43 Grade OPC Cement)
14Bill No. 2 Bridge work Sub-structure
15Supplying, fitting and placing TMT bar reinforcement (Fe 500) in foundation complete as per drawings and technical specification Clauses 1002,1202
16Providing and laying Plain cement concrete M-20 in substructure complete as per drawings and technical specification Clauses 802,804,805,806,807,1202 ans 1203(Using 43 Grade OPC Cement)
17Providing and laying in situ/ ready mix controlled M-25 cement concrete of trap/ granite/ quartzite/ gniess metal for reinforced cement concrete caps over piers and abutments including necessary sacffolding plywood/ steel formwork, compacting by vibrating, finishing in CM 1:3 and curing etc complete (Excluding reinforcement) With reversible drum type mixer/ concrete batch mix plant (panmixer). with fine agreegates of required specifications (Natural sand/ VSI sand finely washed etc )
18Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002,1005, 1010, 1202
19Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8
20Backfilling with Granular material behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
21Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
22Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302(150mm thick quarry spall)
23Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302
24Providingand laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specified thickness as per detailed drawing including supplying all materials, hand packing of rubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete
25Bill No. 3 Bridge work Super-structure
26Providing and laying Reinforced cement concrete M-25in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 (RCC M-25 Slab )
27Providing and laying cement concrete wearing course M-30 grade excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
28Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
29Providing and fixing in position railing consisting of IS Rolled steel joist posts designation IS MB 100 (100 x 75) at 2.5 m interval and three rows of 50 mm dia steel pipes ( light ) including fixing in position on bridge deck complete as per drawing and technical specification Clause 1208.2
30Providing Tar paper bearing of approved quality in proper size etc. complete.
31Expansion joint with 25 mm thich bitumenous pad.
32Providing and fixing Granite / Marble tablet of15mm to 18mmthickness ,including making groove in wall / concrete surfacefilling joints with slurry, curing, polishing, rounding edges, as required cleaning etc.complete.of size and description as per detailed drawings including embosseing & fitting in1:2 C.M. border.
33Bill No. 4 Bridge work Approches
34Cleaning grass and removal of rubbish up to a distance all lead and lift outside the periphery of the area as per Technical Specification Clause 201.
35Excavation for roadway in soil with hydraulic excavator of 0.90 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transportating to the embankentlocation with all lift and lead . as per Technical Specification Clause 302.3
36Construction of embankment with approved material obtained from borrow pits with all lift and lead , transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per technical Specification Clause 301.5
37Construction of granular sub-base by providing Grading-I material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with vibratorywheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
38Providing, laying, spreading and compacting stone aggregates of specific sizes to Water Bound Macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.
39Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material and single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. Clause 1106.(800 mm Diameter NP-2 Pipe)
40Boundary Pillar Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
41Construction of embankment with approved materials with 95% P.D. deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300.1 and 300.2 as per technical specification clause 301.5 for P.D.95% to 100%
42Construction of earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope andcompacting with vibratory roller to meet requirement of Table 300.2 with lead upto as per Technical Specification Clause 303.1
43Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. (MoRD Specification 2004)(A)50 mm thick UsingBitumen VG-30
44Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kg/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates) (Above M.P.M.)
45Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2mm to 5.6mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat as per Technical Specification Clause 508. (excluding seal coat)
46Providing and laying Seal Coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A,Type B( by paver finisher ) & Type C as per Technical Specification Clause 510.
47Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 cement concrete blocks of size as per table 1300.2 cast in cement concrete of grade M-15
48Providing concrete for plain cement concrete M-10 in open foundations complete as per drawing and Technical Specification Clauses 802,803,1202 and 1203.(Using 43 Grade OPC Cement PCC M-10 for levelling coarse of toe wall & protection Wall)
49Bill No. 5 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
50STANDARD METAL DELINEATOR Supply and Installation of Road delienators ( Road way Delienators ) as per MORT&H clause 806.The structure shall be manufactured in roll forming process and shall have height not less than 800 mm above the ground, width not less than 100 mm and shall extend not more than 300mm below the ground while being installed in confirmation with IRC:79 1981or as directed by engineer in charge.The delineator shall be painted with powder coat of minimum 40 microns thickness for protection against corrosion, on top of which Type XI retro reflective sheeting shall be pasted on both sides.The delienator shall consist minimum retro reflective unit exposed area of 330 cm2 white color, full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67 2012 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI table specification.The front and back faces of the delineator should be curved with a radius of not more than 200 mm and with delta angle (or central angle of curve) lying between 20o and 30o, to increase the visibility of the delineator for vehicles moving in continuous curves. The delineator shall have grooves across the length to make the reflective sheets vandal-proof.
51Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of TwoPlates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plateswill be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
52MMGSY Citizen" s information Board- Providing and fixing of typicalMMGSY Retro Reflective information board as peras per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottomduly rivetted with MSangles of 35 x 35x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
53Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height,firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.ii) 600mm Equilateral & Triangle
54Providing and fixing Retro Reflective MMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of TwoPlates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plateswill be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
55Supplying & Fixing of Molded Shank Raised Pavement Markers / Cat"s Eyemade of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer"s recommendation and complete as directed by the engineer.The contractor shall submit a two year warrantyfor satisfactory field performance including stipulated retro-reflectance of the reflecting panel, to the Engineer.
56Road marking with Hot Applied Thrmoplastic compund with reflectorizing Glass beads on Bituminous surface - providing and laying of hot applied thermoplastic compund 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes complete.
57Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. iv) 800mm x 600mm Rectangular
58Painting lines, dashes, arrows, etc. on roads in two coatson new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
59Rubble fillling in foundation trenches as per drawing and technical specification Clause 305.3.9( below Protection Wall)
60Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)"
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy