Bids Are Invited For Pm 2.5 Sampler - 1.Sampling Principle: Impactor Based Design As Per Epa / Usepa And Cpcb Guidelines Specifications 2.Particle Separation: Omni-Directional Air Inlet With Pm10separation Through An Impactor Followed By Pm 2.5 Separati-Odisha

Forest And Environment Department has published Bids Are Invited For Pm 2.5 Sampler - 1.Sampling Principle: Impactor Based Design As Per Epa / Usepa And Cpcb Guidelines Specifications 2.Particle Separation: Omni-Directional Air Inlet With Pm10separation Through An Impactor Followed By Pm 2.5 Separati. Submission Date for this Tender is 01-11-2021. clocks Tenders in Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

29538847
Bids Are Invited For Pm 2.5 Sampler - 1.Sampling Principle: Impactor Based Design As Per Epa / Usepa And Cpcb Guidelines Specifications 2.Particle Separation: Omni-Directional Air Inlet With Pm10separation Through An Impactor Followed By Pm 2.5 Separati
Open Tender
Indian
Odisha
01-11-2021

Tender Details

Bids Are Invited For Pm 2.5 Sampler - 1.Sampling Principle: Impactor Based Design As Per Epa / Usepa And Cpcb Guidelines Specifications 2.Particle Separation: Omni-Directional Air Inlet With Pm10separation Through An Impactor Followed By Pm 2.5 Separation Through A Wins Impactor 3.Sampling Rate: Sampling Rate Of About 1 M3 / Hr, Unaffected By Voltage Fluctuations And Filter Chocking Maintained By Critical Orifice System, Microprocessor Based Digital Flow Controller And Other Suitable Flow Controller. 4.Filter Holder: Filter Holder, Designed To Accept Any Standard Filter Media Of 46.2 Mm Diameter.5.Samplingdurationrecorder: Time Totalizer To Record The Sampling Duration To The Nearest 0.01 Hour.6.Flow Recorder & Display System : Recorder For Flow Rate, Volume Of Sampled Air, Air Temperature, Filter Temperature, Barometric Pressure And Filter Pressure With 20×4 Lcd Display Showing Real Time Viz.7.Auto Shut Off Facility: Auto Shut Off And Start Facility For The Sampler If Flow Rate Drops By More Than 10 % From The Designed Value With Accuracy ± 2 Min / Month.8.Pump: Oil Free, Low Noise, Driven By Brushless Induction Motor.9.Power Requirement: Single Phase Ac, 220 Volts, 50 Hz Supply, Sampler To Be Unaffected By + / - 10% Fluctuation In Supply Voltage.10.Std. Accessories: The Equipment Is To Be Supplied With Mains Cord And Tool Kit. , Respirable Dust Sampler - 1.General: Equipment Shall Conform To Bis, Is: 5182 ( Part-23 ) : 2006.2.Blower : Noiseless, Brush Less 3. Noise: Operating Noise Of The Equipment Shall Not Exceed By More Than 5 Db ( A ) Than The Ambient Noise Level At A Distance Of 5M From The Equipment. 4. Flow Rate : 0.8-1.4 M3 / Min Free Flow 5.Particle Size: Coarser Particles > 10 Microns Shall Be Separated By A Sharp Cutoff Cyclone And Collected Separately. The Particle Size Of Less Than 10 Microns Shall Be Collected On Glass Micro Fiber Filter Paper Of Standard Size, 203 Mm X 254 Mm To Be Mounted In The Filter Holder.6.Sampling Time : Maximum, Continuously For 24 Hours 7.Sampling Time Recorder : 0 To 9999.99 Hrs.10.Time Totalizer Circuit :For The Detection Of Blower Stoppage Due To Any Reason.11.Power Requirement : 230 + 10 V, Single Phase, 50 Hz Ac 12.Voltage Stabilization : By Built In Voltage Stabilizer With Automatic Shut-Off Beyond 170-270V Gaseous Sampling : Flow Rate : 0.3 To 3 Lpm, + 2% Accuracy , Flow Control: Four Inlet And One Outlet Manifold With Built In Needle Valves For Flow Control At The Inlet, Temperature Controller : Gaseous Sampling Attachment Should Be Fitted With Thermo Electrical Cooling Facilities To Maintain The Impingers At 15O C , Sampling Train: Capacity - 35 Ml Borosilicate Glass Impingers ( 04 Nos. ) , Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
INR 240000.0 /-
Tender Value
INR 96 Lakhs /-

BOQ Items

Sl. No. Item TitleItem Description
1PM 2.5 SAMPLER1.Sampling principle: Impactor based design as per EPA/USEPA and CPCB guidelines specifications 2.Particle Separation: Omni-directional air inlet with PM10separation through an impactor followed by PM 2.5 separation through a WINS impactor 3.Sampling Rate: Sampling rate of about 1 m3 / hr, unaffected by voltage fluctuations and filter chocking maintained by critical orifice system, microprocessor based digital flow controller and other suitable flow controller. 4.Filter Holder: Filter holder, designed to accept any standard filter media of 46.2 mm diameter.5.Samplingdurationrecorder: Time totalizer to record the sampling duration to the nearest 0.01 hour.6.Flow Recorder & Display System : Recorder for flow rate, volume of sampled air, air temperature, filter temperature, barometric pressure and filter pressure with 20×4 LCD display showing real time viz.7.Auto shut off facility: Auto shut off and start facility for the sampler if flow rate drops by more than 10 % from the designed value with accuracy ± 2 min/month.8.Pump: Oil free, Low noise,driven by brushless induction motor.9.Power requirement: Single phase AC, 220 Volts, 50 HZ supply, Sampler to be unaffected by +/- 10% fluctuation in supply voltage.10.Std. Accessories: The equipment is to be supplied with mains cord and tool kit.
2RESPIRABLE DUST SAMPLER1.General: Equipment shall conform to BIS, IS: 5182 (Part-23): 2006.2.Blower : Noiseless, brush less 3. Noise: Operating noise of the equipment shall not exceed by more than 5 dB (A) than the ambient noise level at a distance of 5m from the equipment. 4. Flow Rate : 0.8-1.4 m3/ min free flow 5.Particle Size: Coarser Particles > 10 microns shall be separated by a sharp cutoff cyclone and collected separately. The particle size of less than 10 microns shall be collected on glass micro fiber filter paper of standard size, 203 mm x 254 mm to be mounted in the filter holder.6.Sampling Time : Maximum, continuously for 24 hours 7.Sampling Time Recorder : 0 to 9999.99 hrs.10.Time totalizer circuit :For the detection of blower stoppage due to any reason.11.Power Requirement : 230 + 10 V, Single Phase, 50 Hz AC 12.Voltage Stabilization : By built in voltage stabilizer with automatic shut-off beyond 170-270V Gaseous Sampling : Flow Rate : 0.3 to 3 LPM, + 2% accuracy ,Flow Control: Four inlet and one outlet manifold with built in needle valves for flow control at the inlet,Temperature controller : Gaseous sampling attachment should be fitted with thermo electrical cooling facilities to maintain the impingers at 15o C ,Sampling Train: Capacity - 35 ml Borosilicate glass impingers (04 Nos.),