Provn Of Three Phase Electric Connection And 100 Kva Dg Set With Amf Panel For Oxygen Generation Plant At Mh Jabalpur Under Ge ( W ) Jabalpur Provn Of Three Phase Electric Connection And 100 Kva Dg Set With Amf Panel For Oxygen Generation Pl, JABALPUR-Madhya Pradesh

Military Engineer Services-MES has published Provn Of Three Phase Electric Connection And 100 Kva Dg Set With Amf Panel For Oxygen Generation Plant At Mh Jabalpur Under Ge ( W ) Jabalpur Provn Of Three Phase Electric Connection And 100 Kva Dg Set With Amf Panel For Oxygen Generation Pl. Submission Date for this Tender is 30-10-2021. Diesel Generators Tenders in JABALPUR Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29527271
Corrigendum : Provn Of Three Phase Electric Connection And 100 Kva Dg Set With Amf Panel For Oxygen Generation Plant At Mh Jabalpur Under Ge ( W ) Jabalpur Provn Of Three Phase Electric Connection And 100 Kva Dg Set With Amf Panel For Oxygen Generation Pl
Open Tender
Indian
Madhya Pradesh
JABALPUR
30-10-2021

Tender Details

Provn Of Three Phase Electric Connection And 100 Kva Dg Set With Amf Panel For Oxygen Generation Plant At Mh Jabalpur Under Ge ( W ) Jabalpur Provn Of Three Phase Electric Connection And 100 Kva Dg Set With Amf Panel For Oxygen Generation Plant At Mh Jabalpur Under Ge ( W ) Jabalpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Oct-2021 Corrigendum No. 01 Other 23-10-2021
2 23-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 66000.0 /-
Tender Value
INR 33 Lakhs /-

BOQ Items

Name of Work: Provn of three phase electric connection and 100 KVA DG Set with AMF panelfor oxygen generation plant at MH Jabalpur under GE (W) Jabalpur.
Sl. No. Item Description
1Basic Rate : Refer Schedule"A" Notes
2Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 95sqmm, 3.5 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion complete all as directed. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE. Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately under respective items of BOQ.
3Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 70sqmm, 3.5 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion complete all as directed. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE. Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately under respective items of BOQ.
4Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor of cross section area 95 sqmm, 3 core conforming to IS 7098 / (PART-II) 1985 with the latest amendments and testing on completion complete all as directed. Make:- Havells or Finolex or Gloster or Plaza or Universal as approved by GE. Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately under respective items of BOQ.
5M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70sqmm to 120sqmm and testing on completion complete all as directed. Make:- M SEAL or RAYCHEM or DENSON or CAB SEAL as approved by GE.
6M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70sqmm to 120sqmm and testing on completion complete all as directed. Make:- M SEAL or RAYCHEM or DENSON or CAB SEAL as approved by GE.
7M&L for earthing complete with galvansided steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.50M deep below ground level) with top edge of earth plate not less than 1.75M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
8M&L for earthing complete with galvansided steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.50M deep below ground level) with top edge of earth plate not less than 1.75M deep below normal ground level, connected to galvanised iron wire 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI wire and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
9M&L for chemical earthingwith copper earth plate electrode 900x600x5mm thick burried directly in earth pit not less than 4.70M below normal ground level and complete size of pit 1.60 X 0.61 M, earth plate connected to copper strip 32x6mm by means of copper/ brass nut & bolts duly brazed, earth strip protected with 40mm bore medium grade GI pipe from electrode and upto and including the earth test point of gun metal/ phosphorous bronze of size 75x75x25mm, 15mm bore medium grade GI watering pipe including funnel, wiremess providing alternate layer of 10cm each charcoal, salt and potassium nitrate (KNO3) layer respectively upto 1.20M and including all necessary excavation, returning filling in, removal of surplus soil to a distance not exceeding 50M, PCC pit in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate), RCC Cover 40mm thick in RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) reinforced with 8mm dia MS deformed bars @ 100 mm c/c both ways including MS handle of 12mm dia round bar to be placed on and including angle iron frame made out of 40x40x6mm angle iron section complete all as specified and shown in concerned TD drawing of CE Jabalpur Zone. Note:- Copper strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
10Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
11Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
12Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed.
13Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed.
14Supply and laying un-reinforced precast concrete cable covers, Class HV, Type1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed.
15Supply and laying un-reinforced precast concrete cable covers, Class LV, Type1, flat, size 250mm x 150mm x 40mm complete all as specified and as directed.
16Supply and fixing/ laying of 50mm bore dia GI pipe light grade in trenches/ under roads/ along pole/ wall including all fittings, ISI marked as required for cable protection etc complete all as specified and directed.
17Supply, fixing and stretching of new aluminum conductor steel reinforced of any sizefor over head line securing on pole complete including binding wire, jointing sleeves aluminium tap and PG clamp etc complete all as specified and directed. Make: Indian Aluminium Co or Bharat conductor or Aluminium India as per approved by GE
18M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel of any sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and dircted.
19Supply and fix new pin type porcelain, vitreous, white/brown/ green insulator 150mm high and 150mm dia including one galvanised milds steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for HT 11000 volts grade complete all as specified and directed. Make : JAYSHREE or JAIPURIA or WS insulator as approved by GE
20M&L for new lightning arrestor Metal Oxide type complete with all fittings, transmision/ distribution class 10 KA, current rating 12 kA suitable for 11 KV system, discharge capacity 65 kilo amps and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed. Make:- SCHNENIDER orBHEL or GE POWER or W/S INSULATORS or SOUTHERN INSULATORS or OBLUM as approved by GE.
21Supply and fixing of new switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 25mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 200 Amp 11000 Volts including dropout fuse set 12 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. Make:- JAIPURIA or PACTIL or BHEL or MEI as approved by GE.
22M&L for danger notice plate of size 25x20cm, made out of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of appropriate size for HT system complete all as specified and directed.
23Supply and fixing 11.0M long steel tubular swaged pole type 410 SP-55 complete with cast iron base plate, finial taper plug, nuts, bolts, screws and washers all as specified including two coats of painting with black bituminous paint upto embedded portion before fixing of poles and two coats of painting withaluminium paint over a coat of primer on exposed surface after fixing complete all as shown in TD drawing No. CEJZ/TD/824/91, Sht No1/2 dt 16.04.91 including following items/ works complete:- (a)Excavation in post holes in any types of soil, returning filling in, well ramming and disposal of surplus soil to a distance not exceeding 50Mfrom the starting points complete all as specified and directed. (b)PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation up to ground level complete all as specified and directed. (c)PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in copings/ collars, bed plates, plinth block etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed. (d)M&L for writing letters or figures (Block, Roman, Italic or Indian) with and including thick enamel paint of approved shade not exc 5cmin height complete all as specified and directed. Make:- NATIONAL TUBING CO. or JINDAL or BHARAT ISPAT UDYOG or JAI BHARAT POLES as approved by GE.
24Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 100 KVA (Level-3), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5%, continuous rating of capacity 100KVA including bushing on HT end & cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.0M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class "B" bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 100mm thick with PCC 1:2:4 type B-1 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- (a)One cable box on primary (HV) side having cable glands suitable for OH conductor (consisting of 3 Nos porcelain HT bushings with brass/ gun metal bushing rods complete with nuts and washers). (b)One cable box on secondary (LV) side consisting of 4 Nos porcelain bushing with GM bushing rods complete with GM nuts, and washers with one No. cable gland suitable for reception of outgoing LT armoured cables of suitable size. (c)Oil conservator tank with filter type, drain valve and oil level gauge.
25(d)Dehydrating breather with first fill of dehydrating agent. (e)Themometer pocket on tank cover. (f) One No. 100mm dia dial type thermometer vapour pressure type having range 0-1200 C with temp reading pointer, max temprature indicator and resetting device. (g)Rating plate with terminal markings. (h)Two earthing terminals on tank/ tank cover to facilitate fixing of 32x6mm GI earth strip. (j)Oil level gauge. (k) Oil drain and filter valves. (l)Oil filter hole with cap/plug with connections complete. (m)Lifting lugs. (n) Air relief valve plug. (o) Plain solid cast steel detachable rollers - 04 Nos. (p) First fill of fresh transformer oil conforming to revevant IS and tested upto 50 KV dielectric strength upto top of core. (q) Extra bushing for neutal outside the LT cable box for providing independent earthing for neutral. (r)Provision of 2 Nos danger boards 250x200mm size made out of 1.6 mm thich MS plate, vitreous enameled white, with letters, figures of voltage and conventional skull and bones in signal red colour, one at HT side and other on LT side. (s) Any other fittings/ accessories so as to confirm the whole transformer to IS-1180 (Part-I) : 2014. (t) Base channel 100x50mm of suitable length duly fixed on platform/ plinth including making locking arrangement. (u) Inspection Cover Make :ABB or SCHNIEDER (AREVA) or Crompton Greavesor RAJASTHAN TRANSFORMERS or ITE Gurgoan or GE Power as approved by GE.
26Supply, installation, commissioning and testing ofAPFC panel of60 KVAr capacity, AC, outdoor type (approximate size 1500x600x1800mm), weather and vermin proof suitably ventilated 440 Volts, 50 cycles, AC supply, factory made fully compartmentalized made out of 3.15mm thick CRCA steel sheet for load bearing and 2mm thick CRCA steel sheet for non load bearing, CPRI approved duly wiring & connection with and icluding FRLS copper flexible wire of suitable rating for power control, panel shall be dully powder coated with 8tanks sheet treatment (de-greasing, water rinsing, de-rusting, activation- phosphating, passivation thickness of powder coating shall no be less than 80 microns), double door with locking arrangement, bus bar chamber to accommodate 04 Nos epoxy painted high conductivity copper bus bars of suitable rating for phase/ neutral with colour coated insulator sleeves including phase indication neon lamps set, danger notice plate, necessary cable glands, cable connections, panel shall be fixed/ mounted on apporx 75cm above from GL on and including suitable size of Base Channel/ Angle Iron or any other section (Zinc metal coated) frame work/ support as per site requirement but not less than of angle iron frame of section 50x50x6mm including all necessary bolts, nuts and washers etc over and including PCC platform of size not less than 1.70x0.80x0.75M height (outer dimensions), 0.60M above GL and 0.15M below GL in PCC 1:2:4 type B2 using 40mm graded stone aggregate, foundation 150mm thick and 150mm extending on both sides of PCC platform in PCC 1:4:8 type D2 using 40mm graded stone aggregate including necessary excavation & earth work and plaster/ rendering in CM 1:4 on all sides of PCC platform upto 15cm below from GL and two coats of white wash on plastered surfaces including prepration of surfaces etc including testing & commissioning with & including following fixures/ fittings complete all as specified and directed:- (A)INCOMING (i)MCCB 4 Pole, 160 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 volts with rupturing capacity 36 KA -01 No. Make:- L&T or Legrand orABB or Schneider as approved by GE. (ii)3 phase ammeter accuracy class 1 - 01 No. Make: C&S Cat No. CSM-A13-S1 or equivalent model of other make-AE/ Legrand / L&T / ABB / as approved by GE.
27(iii) 3 phase volt meter accuracy class 1 - 01 Set Make: C&S Cat No. CSM-A-V3-S1 or equivalent model of other make-AE/ Legrand / L&T / ABB / as approved by GE. (iv)LED phase indication lamps RYB-01 Set Make : As approved by GE. (v) MCB SP, 02 Amps, "C" series, 240/410 volts, 50Hz, 10kA - 03 Nos. Make:- L&T or Legrand orABB or Schneider as approved by GE. (vi)APFC relay with three CT, one per phase AC -01 Set Make: C&S Cat No. CSPF 200-15 or equivalent model of other make-Legrand / L&T / ABB / Schneider/ Hensel as approved by GE. (vii)Automatic/ malual switch - 01 No. Make: C&S Cat No. RCP2BD2 or equivalent model of other make- Legrand / L&T / ABB / Schneider/ Hensel as approved by GE. (B) OUTGOING (i) Capacitor 20 kVAr heavy duty, 440 volts, cylindrical -03 Nos Make : Legrand Cat No.415130 or equivalent model of other make L&T / ABB / Schneider as approved by GE. (ii) MCB TPN, 63 Amps, "C" series, 415 volts, 50Hz, 10kA - 03 Nos. Make:- L&T or Legrand orABB or Schneider as approved by GE. (iii)Capacitor duty contactor 20 kVAr, 3 pole -03 Nos Make : L&T Cat No. MO-20 CS 90021 or equivalent model of other make- Havells / Schneider/ ABB/ Legrand as approved by GE. (iv)ON/ OFF push button -03 Sets Make : C&S Cat Nos. RB2-BA4 & RB2-BA3 or equivalent model of other make- Havells / Schneider/ ABB/ Legrand as approved by GE. (v) LED 22.5mm dia Red & Green -03 Sets Make : C&S Cat Nos. RB2-BVL04 (Red) & RB2-BVL03 (Green) or equivalent model of other make- Havells / Schneider/ ABB/ Legrand as approved by GE. (vi)As per load condition, sensing CT 200/5 shall be provided along with APFC panel. Make : C&S Cat Nos. CSPF 200-15 or equivalent model of other make- AE/ Havells / Schneider/ ABB/ Legrand as approved by GE.
28(vii) Armoured 1.50 Sqmm 2 core copper conductor cable of make as approved by GE of suitable length shall be provided for sensing CT. Make of APFC Panel : Tricolite or Mc Layers or Universal Switchgearl as approved by GE. Notes: (i) GA drawing for APFC panel shall be got approved from GE before manufacturing of the panel. (ii) Contractor shall make all necessary arrangement for pre dispatch inspection by GE"s representative at manufacturer"s workshop. (iii)Manufacturer"s test report for powder coating shall also be provided with panel. (iv)Quoted rate shall be deemed to be included for complete materials & labours as required for full functioning of APFC panel and other provisions as mentioned here-in-before including necessary testing if required.
29Supply, fabricating and erecting/ fixing / installation of outdoor LT panel with projected globe roof for rain water protection (feeder pillar box), CPRI approved outdoor type (approximate size 1200x450x1000mm), weather and vermin proof suitably ventilated for 440 volts, 3 phase 4 wire system, AC supply, factory made fully compartmentalized made out of 3.15mm thick CRCA steel sheet for load bearing and 2mm thick CRCA steel sheet for non load bearing, protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour, double door with both side opening alongwith locking arrangement, bus bar chamber to accommodate epoxy painted high conductivity copper bus bars of 400 Amps for phase and 200 Amps for neutral rating with colour coated insulator sleeves including phase indication neon lamps set, danger notice plate, necessary cable connections with suitable size of cable lugs and glands, internal wiring with suitable size copper conductor cable, panel shall be fixed/ mounted on apporx 75cm above from GL on and including suitable size of Base Channel/ Angle Iron or any other section (Zinc metal coated) frame work/ support as per site requirement but not less than of angle iron frame of section 50x50x6mm including all necessary bolts, nuts and washers etc over and including PCC platform of size not less than 1.20x0.65x0.75M height (outer dimensions), 0.60M above GL and 0.15M below GL in PCC 1:2:4 type B2 using 40mm graded stone aggregate, foundation 150mm thick and 150mm extending on both sides of PCC platform in PCC 1:4:8 type D2 using 40mm graded stone aggregate including necessary excavation & earth work and plaster/ rendering in CM 1:4 on all sides of PCC platform upto 15cm below from GL and two coats of white wash on plastered surfaces including prepration of surfaces etc including testing & commissioning with & including following fixures/ fittings complete all as specified and directed:-
30(i)Ammeter of rating (0-500Amps) digital type with 03 Nos CT 250x5 Amps and selector switch - 01 Set Make : C&S or AE or L&T or Schneider or ABB or Legrand as approved by GE. (ii) Volt meter of rating (0-500V) digital type with selector switch - 01 Set Make : C&S or AE or L&T or Schneider or ABB or Legrand as approved by GE. (iii) INCOMING MCCB 4 Pole, 250 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 50 kA -01 No. Make:- L&T or Legrand orABB or Schneider as approved by GE. (iv) OUTGOING (a) MCCB 4 Pole, 200 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 50 kA -01 No. Make:- L&T or Legrand orABB or Schneider as approved by GE. (b) MCCB 4 Pole, 160 Amps, Thermal Magnetic Release, Ics = 100% of Icu, 415 Volts with rupturing capacity 25 KA -01 No. Make:- L&T or Legrand orABB or Schneider as approved by GE. (v) LED phase indication lamps RYB-03 Sets Make : As approved by GE. Make of Panel: Tricolite or Mc Layers or Universal Switchgearl as approved by GE. Notes: (i) GA drawing for panel shall be got approved from GE before manufacturing of the panel. (ii) Contractor shall make all necessary arrangement for pre dispatch inspaction by GE"s representative at manufacturer"s workshop. (iii)Manufacturer"s test report for powder coating shall also be provided with panel. (iv)Quoted rate shall be deemed to be included for complete materials & labours as required for full functioning of panel and other provisions as mentioned here-in-before including necessary testing if required.
31Supply, installation, commissioning and testing of Servo controlled voltage stabilizer of cpacity 150 KVA conforming to BIS 9815: Part-I (1994) (reaffirmed 2009), 3 phase, 50 Hz, naturally oil cooled, out door, unbalanced type, copper wound, metallic body duly powder coated with lifting hooks two Nos., digital display type, relay free smooth and silent operation with Ist fill of transformer oil up to level conforming to revevant IS having following specifications with and incuding fixing on PCC plateform:- (a) Input voltage (360-480) volts and output voltage stabilized at any deigned/ desired voltage 415 volts with + 1% (adjustable). (b) Rated frequency 50 Hz.
32(c) No distortion in wave form. (d) Responding time not to exceed 20 mille seconds. (e) Sensitivity (+/-) 1% (f)Rate of correction 8 volt/ second for single phase and 20 volt/ second for phase to phase. (g) Digital display Voltmeter/ Ammeter (h) At no load- losses less than 0.5% and at full load- losses less than 2.5%. (j)Over load/ short cicuit protections. (k) High/ low voltage cut off (l)By pass arrangement in case of emergency (m)Single phase sequence change protection (n) Foundation/ Plinth/ Base: PCC platform of size extended 0.50M all round of voltage stabilizer (outer dimensions), 0.60M above GL and 0.15M below GL in PCC 1:2:4 type B2 using 40mm graded stone aggregate, foundation 150mm thick and 150mm extending on all sides of PCC platform in PCC 1:4:8 type D2 using 40mm graded stone aggregate including necessary excavation & earth work and plaster/ rendering in CM 1:4 on all sides of PCC platform upto 15cm below from GL and two coats of white wash on plastered surfaces including prepration of surfaces complete. Make :APLAB or AE or BRENTFORDor SINETRAC as approved by GE. Note:- Quoted rate shall be deemed to be included for complete materials & labours as required for full functioning of Servo controlled voltage stabilizer including PCC foundationas mentioned here-in-before and necessary testing if required.
33M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and sub base of floors, path/ paving etc complete all as specified & directed.
34M&L for 40mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed. Note:- Stack measurements after considering engineering practice for voids shall be recorded in MB for payment of this item.
35Supply, installation, testing and commissioning complete of OEM manufactured, static silent (Sound proof enclosure) Diesel Engine Driven Generating set capable of delivering 80 KW (100 KVA) output, 415 Volts (AC three phase, 4 Wire system of supply) 50 Hz at 0.80 minimum power factor conforming to IS: 10001/10002 for engine and IS:13364 for alternator. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with AMF control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe including all mounting accessories as required/ suitable for installation at Jabalpur (MP) complete including, anti-vibration pads, including all features to comply with latest CPCB guidelines and comprising of followings:- Note:- Capacity of engine, alternators shall be worked out taking all derating factors into consideration.
36(a) ENGINE (prime mover): Diesel engine 1500 RPM, direct injection, four (04) cylinders inline, four stroke, confirming to ISO 3046/BS 5514, naturally turbo charged, capable of giving adequate BHP (Not less than 126.5 BHP) to drive alternator capable of delivering 80 KW (100 KVA) at outdoor atmoshpheric conditions at Jabalpur, 12/24 Volts (as per manufacturer recommendations) electric battery start, complete with dynamically balanced fly wheel, all standard fittings/ fixtures as per manufacturers with and including suitable panel with tachometer, lub oil temperature, pressure gauze and frequency meter and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and engine protection systems (shut down, high water temperature, low lub oil, oil pressure, over speed etc), fuel tank and first fill of lub oil and other consumables items etc complete. MAKE:- CUMMINS or equivalent model of other make- CATERPILLAR or KIRLOSKAR or GREAVES COTTON LTD. as approved by GE.
37(b) Alternator: Brushless, self excited, self regulated, AC alternator, 3 phase 415 Volts, 4 wire rated for output of 100KVA/ 80 KW, minimum power factor 0.8, 1500 RPM, IP23 protection class enclosure, insulation class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match with the engine as specified above. MAKE: STAMFORD or equivalent model of other make- CATERPILLAR or GREAVES COTTON LTD. or KIRLOSKAR or JYOTI as approved by GE.
38(c) BASE PLATE:Made out of structural steel as per manufacturers recommended design/specifications complete.
39(d) Accoustic Enclosure: (i)Engine alternator assembly mounted on AVM with silencer and SS exhaust below suitably optimized to meet stringent sound emission standards as laid down by MOEF/ CPCB. (ii) Base rail with-draw type fuel tank with a drain plug, air vent inlet and outlet connections, level indicator, manhole etc. (iii)Sub base fuel tank with minimum 13 Hours capacity at 75% load. (iv)12 Volt dry battries with connecting leads and terminals. (iv)90% gloss RAL9003 white pure polyester powder coated and base in black colour. Note: Enclosure shall be designed for reducing the sound level as under with following conditions as laid down in GSR No. 371 (E) dt 17 May 2002: (i)75 DB at a distance of 1.0M at 75% load under field condition. (ii) 70 DB at 3.0M from Gen set when DG set is working at full load along with testing conformance, labelling certificaton, etc
40(e) AMF Control Panel: RAL 9003 white powder coated control panel manufactured with CRCA sheet. Control panel shall have following features:- (i) Water and lube oil drain outlets to be located on the outer surface for easy of maintenance & cleanliness. (ii)MCCB of suitable rating as per manufacturer recommendations with overload and short circuit protection. (iii) Controller as per manufacturer recommendations which displays Voltage, Current, KW, PF, Frequency, KWh. (iv)Indicating lamps for "Load On" and "Set Running". (v) Current Tranformers of suitable rating as per manufacturer recommendations (vi)Copper cables of suitable capacity with incoming and outgoing terminations. (vii) Control fuses duly wired and ferruled. (viii) All standard relays, circuits and protection required for automatic operation of Gen set. (ix)Power cables : Uninyvin copper conductor cables between Alternator & Control Panel inside the canopy.
41(f) Foundation/ Plinth/ Base: PCC platform of size extended 0.50M all round of DG set (outer dimensions), 0.60M above GL and 0.15M below GL in PCC 1:2:4 type B2 using 40mm graded stone aggregate, foundation 150mm thick and 150mm extending on all sides of PCC platform in PCC 1:4:8 type D2 using 40mm graded stone aggregate including necessary excavation & earth work and plaster/ rendering in CM 1:4 on all sides of PCC platform upto 15cm below from GL and two coats of white wash on plastered surfaces including prepration of surfaces complete.
42(g) Miscellaneous: Tool kit, operation and maintenance catalogue, spare parts list, overhauling manuals, guarnatee card etc shall be provided as per manufacturer standard practices as and when asked.
43General Notes for item No. 48.00:- (i) The DG set shall be taken over only after it has been tested as per relevant IS specification/ instructiions by the contractor in the presence of an officer nominated by the accepting officer. (ii) All the expenses incurred on the above test including provision of testing apparatus required to carry out the above mentioned test shall be born by the contractor without any extra cost to the government. If the result of the test is not found satisfactory, the contractor shall at his own expense, replace the defective equipments/ materials/ accessories or any thereof as directed by the GE. Decision of accepting officer shall be final conclusive and binding in this respect.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail