| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-12-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 31-12-2021 |
| 2 | 13-12-2021 | revised BOQ | BOQ | 24-12-2021 |
| 3 | 13-12-2021 | amendment in tender documents | Other | 24-12-2021 |
| 4 | 09-12-2021 | cancellation of fwd letter | Other | 24-12-2021 |
| 5 | 09-12-2021 | change in crtical dates | Date | 24-12-2021 |
| 6 | 09-12-2021 | amendment tender documents | Technical Bid | 24-12-2021 |
| 7 | 03-12-2021 | change in critical dates 03 Dec | Date | 16-12-2021 |
| 8 | 25-11-2021 | change in critical dates 25 Nov | Date | 09-12-2021 |
| 9 | 15-11-2021 | change in critical dates | Date | 01-12-2021 |
| 10 | 09-11-2021 | 2ND CHANGE IN CRITICAL DATES | Date | 22-11-2021 |
| 11 | 21-10-2021 | 1ST CHANGE IN CRITICAL DATES | Date | 16-11-2021 |
| Sl. No. | Item Description |
| 1 | B/R PORTION |
| 2 | S & F in repair HDPE white/Black notted nylon net of size 25mmX25mm with 1mm thickness, weatherproof, U V stabilized and chemically and breaking strength of 23.08 Kg per yarn, melting point of 160 degree celcius holding with J-type hook and nylon seathing net streched using 2mm dia SS (SWR) wire at 3m c/c spacing complete all as specified and directed. |
| 3 | S & F nylon bird proofing net of mesh size 25mmX25mmX3mm including all PVC ties and clip ,weaving as for doors and other vertical members/area complete all as specified and directed. |
| 4 | S & F turbo ventilators 600mm dia spirally vanned fixed with poly baseintegrated bearing housing with rotation speed for winds upto 1Km /hr. and suitable to sustain wind speed up to 125 Km/hr.winds with all aluminum integrated and reinforced, encased main with twin ZZ ball bearingsof SS and vary pitch of aluminum base fitted and flushed to the existing roofing profile complete all as specified and directed. (Make:- B K Garg Metals & Alloy/ Fapal Roofs India P Ltd/ DURA/ BANSAL Roofing) |
| 5 | Taking down chowkats or frame n. exc 1.50 Sqm with shutter (without taking off shutters from frames) and making good the same to match with existing surfaces complete all as specified and directed. |
| 6 | S & FAluminum frame for door,windows,vantilators with one or more rebates including joining cleats for fixing etc. duly Powder coatedcomplete all as specified and directed. |
| 7 | S & F Powder coated (min 50 micron thick coating of any colour) Aluminum door shutter with aluminium sectionweighing 0.55kg/m including necessary jointing cleats glazing clips, rubber neoprene packing, handles 2 Nos in each door, ss hinges, anodized aluminum snap beading, screw etc. complete all as specified and directed. |
| 8 | S & FPowder coated (min 50 micron thick coating of any colour) Aluminum window and ventilators shutters side hung type without sash bars,aluminium section weighting 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing,anodised aluminum snap beading,screws,anodised aluminum fitting such as peg stays 150mm long 1 no, ss hinges type B-21 100 mm long minimun 3 Nos., suitable handle 2 Nos. complete all as specified and directed. |
| 9 | S & F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminumalloy sheet foundation box, main body with stainless steel cover,govering pivot made of brass, other parts made of mild steel heavy duty (ISI marked) complete all as specified and directed. |
| 10 | S & F Aluminum extruded section body door closer hydraulically regulated designation no 3 universal type suitable for door shutter up to 851 to 1000 mm in width and for weight of shutter between 61 to 80 kg and fixed complete all as specified and directed. |
| 11 | S & F Sheet glass 5.50mm thick ordinary quality and glazing with and includingbeading in square not exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 12 | Taking down cement plaster or cement lime plaster from PCC/stonesurface/brick surfaces including raking out joints hacking for keyscrubbing down with water etc. complete all as specified and directed. |
| 13 | M & L for rendering 15 mm thick in cement mortar (1:6) on other then fair faces of brickwork or concrete surfacesfinished even & smooth without using extra cement complete all as specified and directed.. |
| 14 | M & L for preparation of new plastered surfaces of walls and applying two coats ofoil bound distemper of approved shade on one coat of primer complete all as specified and directed. |
| 15 | Hacking out old broken glass any thickness, size, quality or description from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads including S&F 3 mm thick plain sheet glass ordinary quality in square not exceeding 0.5 complete all as specified and directed. |
| 16 | S&F PUF (Poly Urethane Foam) insulation of minimum density 40 Kg/Cum to windows not exceeding2.00 Sqmas sealant complete all as specified and directed. |
| 17 | Demolition ofcement concrete (unreinforced) of any descriptionand any position not otherwise specifically provided for etc. and removal of debris to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 18 | M & L for Pre-cast cement concrete block masonry Type C-1 1:3:6 (20mm graded stone aggregate ) exc 10cm in width and setting in cement mortar 1:4 complete all as specified and directed. |
| 19 | M & L for 10 mm thick renderingin cement mortar 1:6 on brick work or concrete surfaces including finishing plaster surface even and smooth without using extra cement complete all as specified and directed. |
| 20 | M & L for machine cutkota stone slab flooring 20-25mm thick over and including cement screedbaseor bedding layer 15mm thick of cement mortar (1:6) etc jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirrorpolishing complete all as specified and directed. |
| 21 | M & L for 18- 20 mm thick granite (of any type) prepolished (mirror) stone tiles machine cut, laid over cement screed and jointed with grey (Table Top) cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing including to edges complete all as specified and directed. |
| 22 | S & Fin repairs bib tap, cast copper alloy chromium plated, with crutch or butterfly handle, screweddown, screwed for iron pipe or for brass ferrule of 15 mm bore complete all as specified and directed. |
| 23 | S & Fin repairs stop valve, cast copper alloy chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions for 15mm bore and fixedcomplete all as specified and directed. |
| 24 | S & F Vitreous china wash hand basin, white, of size 550x400mm flat back excluding taps, waste, chain and plug but including brackets, cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 25 | S & F waste fitting brass chromium plated 32mm bore with long screwed shanks and fly nuts including 32mm PVC waste pipe for WHBcomplete all as specified and directed. |
| 26 | S&F SS chromium plated grating 125mm dia of weight not less than 50gm for floor trap / Nahani trap complete all as specified and directed. |
| 27 | S&F in repair aluminum anodized tubular towel rail, 20mm dia, \"D\" type, 60cm long between flanges complete all as specified and directed. |
| 28 | S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, ISI marked of 110mm bore complete all as specified and directed. |
| 29 | S & F Gypsum Board 12mm thick in false ceiling fixed with screw Hanger 6 mm dia G.I (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long and Anodized aluminum snap grid frame works as per manufacturers instructions as in false ceiling complete all as specified and directed. |
| 30 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ), removing serviceable tiling to store and rubbish off the premises complete all as specified and directed. |
| 31 | M & L for Light Shadevitrified ceramic tiles 10 mm thick (Square/rectangular) polished, area of each tileexceeding 0.36 Sqm but not exceeding 0.42 Sqm ,in floor over and including 10 mm thick screed bed in cement mortar 1:4 etc, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. |
| 32 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 33 | Excavatingin post holes (or similarholes ) in any type of strata each n. exc 0.5 Cum , getting out, removingsurplussoil to a distancenotexceeding50mtr and making good surface complete all as specified and directed. |
| 34 | M & L forPCC 1:3:6 Type C2 using 40mm grade stone aggregate as in foundation complete all as specified and directed. |
| 35 | M & L for mild steel rolled section such as angles etc. as in purlins, rafter confirming to grade Fe-410-W(Gde-E-250) quality \"A\" complete all as specified and directed. |
| 36 | S & F mild steel screw bolts (machine made) not exceeding 5cm in length and 5 to 10mm dia with hexagonal or square head at one end and screwed the other each screwed to be fitted with washers and hexagonal or square nut complete all as specified and directed. |
| 37 | M & L for chequred or plain MS plates, channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment to grade Fe-410W E-250 quality \"A\" complete all as specified and directed. |
| 38 | M & L for preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of zinc crome primer complete all as specified and directed. |
| 39 | S & F Pre painted galvalume aluminum zinc coated GI based corrugated steel sheet 0.50 mm thick any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 40 | M & L for 100 mm thick Cement Concretein sub base to floors, type D-2, PCC 1:4:8 ( 40mm graded aggregate ) complete all as specified and directed. |
| 41 | M & L for 60mm thick, M 35 grade, Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 ,with grey cement and no pigment over and including 25mm thick sand complete all as specified and directed. |
| 42 | M & L for precast PCC blocks or slabs for kerb or similar work 150 mm thick (1:2:4) mix type B-1 using 20 mm graded aggregated with plain or interlocking joints as directed complete in walls setting in CM (1:6) complete all as specified and directed. |
| 43 | M & L for coloured glazed ceramic tiles of size 300x200x7mm thick as in vertical surfaces set and jointed in near cement slurry and pointed in white or coloured cement to match over and including 10mm thick screed bed or bedding layer of cement mortar 1:4 complete all as specified and directed. |
| 44 | Supply only HDPE white/Black notted nylon net of mesh size 25mmx25mmwith thickness of wire1mm , weather proof, U.V stabilized complete all as specified and directed |
| 45 | Supply only SWR wire 4mm in thickness |
| 46 | INTERNAL ELECTRIFICATION |
| 47 | Taking down carefully existing copper/aluminium point wiring for light/fan/sockets complete with all accessories such as switches sockets ceiling rose, wall bracket etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface etc. complete all as specified and directed. |
| 48 | Taking down submain wiring any type and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface etc. complete all as specified and directed. |
| 49 | Taking down DB any type and removing dismantled material and making good disturbed surface of walls/floors etc. matching with existing surface etc. complete all as specified and directed. |
| 50 | M & L for point wiring for one light / fan pointcontrolled by one one way switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi stranded copper conductor cable FR-LSH passing through and including concealed PVC conduit 20 mm dia,heavy duty, ISI marked including new steel terminal sunken boxes suitable for modular switch/socket flush to surface including PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in cement mortar (1:3) and finishing the surface to match with existing surface etc. complete all as specified and directed. |
| 51 | All as per srl item No.48.00above but for one 3 pin socket out let 5 Amp on independent board for special power supplycomplete all as specified and directed. |
| 52 | AllaspersrlitemNo.48.00above but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent boardincluding provn of2.5 Sqmm unsheathed, multi strandedcopper conductor cable FR-LSH continues as earth wire connected to earth dolly for special power supply complete all as specified and directed. |
| 53 | S & F modular switch piano , 6 Amp 240 VoltAC,1 module(ISI Marked) one way including decoraive frame/ cover plate etc. complete all as specified and directed. |
| 54 | S & F modular socket, 2 module, outlet 5 Pin 6 Amp 230 volts AC including decorative frame/cover plate etc. complete all as specified and directed. |
| 55 | S & F modular switch 1 module16 Amp, for outletmultipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC including decorative frame/ cover plate etc. complete all as specified and directed. |
| 56 | S & F modular socket , 2 module6 /16 Amp,3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC including decorative frame/ cover plate etc. complete all as specified and directed. |
| 57 | S & F Modular type box for AC including mini MCB SP 20 Amp 240 volts heavy duty including consealed sunken box with ISI plug top complete all as specified and as directed. |
| 58 | S & FLED Recessed full lit luminaire with glare free uniform illumination with longer life and less maintenance 50Win 2 ft x 2 ft (>100 Lumen/Watt) fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to fitting connection etc. complete all as specified and directed. Make: Crompton, Cat No. LCTLRN-50-FO-CDL.WW.TL or equivalnet from make mentioned in Appendix \"B\". |
| 59 | S & FLED Recessed full lit luminaire with glare free uniform illumination with longer life and less maintenance 36 Win 2 ft x 2 ft (>100 Lumen/Watt)complete fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to fitting connection etc. complete all as specified and directed. Make- Crompton Part No.LCTLRN--36-FO-CDL or equivalent from make mentioned in Appendix \"B\". |
| 60 | S & FWall mounted fan 450mm sweep with step type regulator 230V silver colour, glossy finish material, metal complete all as specified and directed. Make- Havellsmodel V-3 or equivalent from make mentioned in Appendix \"B\". |
| 61 | S & F modular ceiling rose surface bakelite 65mm x 50mm, 2 to 3 terminalswith back plate PVC/polycarbonate, isolated body etc. complete all as specified and directed. |
| 62 | M & L for Sub main wiring with four single core cable PVCinsulated unsheathed of copper multi strandard conductor FR-LSH cable of size10 sqmm, 1100 votls grade drawing through and including concealed PVC conduit 40 mm diaheavy duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 10 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in cement mortar (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed. (Note:- Four runs of main cable and one run of earth cable and one run of conduit will be measured as one unit.) |
| 63 | M & L for Sub main wiring with two single core cable PVCinsulated unsheathed of copper multi strandard conductor FR-LSH cable of size6 sqmm, 1100 votls grade drawing through and including concealed PVC conduit 20 mm diaheavy duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in cement mortar (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed.(Note:- Two runs of main cable and one run of earth cable and one run of conduit will be measured as one unit.) |
| 64 | M & L for Sub main wiring with two single core cable PVCinsulated unsheathed of copper multi strandard conductor FR-LSH cable of size4 sqmm, 1100 votls grade drawing through and including concealedPVC conduit 20 mm diaheavy duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in cement mortar (1:3) and finishig the surface to match with existing surface, etc. complete all as specified and directed. (Note:- Two runs of main cable and one run of earth cable and one run of conduit will be measured as one unit.) |
| 65 | S & F VTPN DB double door sheet metal enclosuremade out of CRCA mild steel sheet concealed surface mounting VTPN, 12 way, 230 Volt, with 200 Amprated bus bar suitable for fixing MCBs, isolators etcincluding MCCB of rating 100 Amp, 25 kA,4 pole,complete all as specified and directed. Make: Model Ekinox TPN DB-VTPN 507753 of Legrand or equivalent from make mentioned in Appendix \"B\". |
| 66 | S & F MCB TPN 63 Amps C curve, rupturing capacity 10 KA etc complete all as specified and directed. Make: Model DX MCB 4087 94 or equivalent from make mentioned in Appendix \"B\". |
| 67 | S & F MCB TP 40 Amps C curve, rupturing capacity 10 KA etc complete all as specified and directed.Make: Model DX MCB 4086 59 or equivalent from make mentioned in Appendix \"B\". |
| 68 | S & F MCB TPN 32 Amps C curve, rupturing capacity 10 KA etc complete all as specified and directed. Make: Model DX MCB 4087 91 or equivalent from make mentioned in Appendix \"B\". |
| 69 | S & F MCBSP 6C curve, rupturing capacity 10 KA etc complete all as specified and directed. Make: Model DX MCB 4085 87 or equivalent from make mentioned in Appendix \"B\". |
| 70 | S & F MCBSP 10C curve, rupturing capacity 10 KA etc complete all as specified and directed. Make:- Model DX MCB 4085 90 or equivalent from make mentioned in Appendix \"B\". |
| 71 | S & F MCBSP 25 C curve, rupturing capacity 10 KA etc complete all as specified and directed.Make:- Model DX MCB 4085 94 or equivalent from make mentioned in Appendix \"B\". |
| 72 | S & F double door sheet metal enclosuremade out of CRCA mild steel sheet concealed surface mounting SPN, 16 way, 230 Volt, with 200 Amprated bus bar suitable for fixing MCBs, isolators etcincluding taking down old complete all as specified and directed. |
| 73 | M & L for chemical earthing complete with copper earth plate electrode (98% conductivity when annealed) of size 900 mm x 600 mm x 5 mm thick buried directly in ground (earth pit not less than 4.00 m deep below normal ground level) with top edge of the plate not less than 4.00 m deep below normal ground connected to and including copper earth strip 32 mm x 6 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixed with charcoal 250 KG, Crystal salt 200 KG, magnesium sulphate of 150 KG and vegetable soil all around the plate up to 350 mm above from top edge of plate and ballance portion filling with excavated soil in layers n.exc 25 mm thick and providing 15 mm bore galvanised iron medium grade watering pipe, 40 mm bore galvanised iron light grade pipe for earth stripprotection, including all excavation earth work in any type of strata, PCC 1:3:6 type C1 for chamber of internal size 300 mm x 300 x300 mm with 120 mm thick wall and 700 mm x 700 mm x150 mm thick bed concrete, RCC 1:2:4,type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/Sqm)with cast iron frame, funnel with wire mesh, test point etc complete all as specified and directed.Note: (i) Earth strip and GI protection pipe up to length 7.5m shall deemed to be included in rate of above item. (ii) The earth resistance value shall be less than 1 Ohm. Failing to achieve the value contractor shall re-do without any extra cost. |
| 74 | Supply and fix Copper strip 20 x 3.15 mmwith saddels and fixing screws for roof conductors and down conductors above ground/earthing lead fixed to wall on batten or recess or chased or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall with and including epoxy based insulatorsor any other indicated situation for loop earthing etc. complete all as specified and directed. |
| 75 | M & L for flameproof point wiring for one lightpoint controlled by one one way switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi stranded copper conductor cable FR-LSH in and including concealed in stove enamelled steel conduit of20 mm diaheavy duty including all accessories such as Tee bend, Elbow etc. ISI marked, fire proof steel terminal sunken boxes flush to surface including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly including cutting chasis to wall and making good disturbed surfaces with cement mortar (1:3) and finishing the surface to match with existing surface, etc. complete all as specified and directed. |
| 76 | M & L for flameproof point wiring for one 3 pin socket outlet, 5 amps, independent,with cables 1.5 sq. (nominal area) PVC insulated, unsheathed multi stranded copper conductor cable FR-LSH in and including concealed in stove enamelled steel conduit of20 mm diaheavy dutyincluding all accessories such as Tee bend, Elbow etc. ISI marked, fire proof steel terminal sunken boxes flush to surface including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FR-LSH connected to common earth dolly including cutting chasis to wall and making good disturbed surfaces with cement mortar (1:3) and finishing the surface to match with existing surface, etc. complete all as specified and directed. |
| 77 | M & L for flameproof point wiring for one One 3 pin socket outlet, 15 amps, independent,with cables 4 sq. (nominal area) PVC insulated, unsheathed multi stranded copper conductor cable FR-LSH in and including concealed in stove enamelled steel conduit of20 mm diaheavy duty including all accessories such as Tee bend, Elbow etc. ISI marked, fire proof steel terminal sunken boxes flush to surface including PVC insulated unsheathed 4 Sqmm copper conductor cable FR-LSH connected to common earth dolly including cutting chasis to wall and making good disturbed surfaces with cement mortar (1:3) and finishing the surface to match with existing surface, etc. complete all as specified and directed. |
| 78 | S & F flame proof switch rotary type with termination box in LM6, 16Amp,single pole ON-OFF ,250 Volt complete all as specified and directed. |
| 79 | S & F LED Flame proof batten suitable for twin T8 tube of 20W , IP 65 protected complete all as specified and directed. Make :- Cat part No EXTN2LT8-16/20 of Crompton or equivalent from make mentioned in Appendix \"B\" for flame proof light. |
| 80 | S & F switch flame proof switch-socket and plug combined in LM6,16Amp,2pin+earth, horizantal pin,250 Volt complete all as specified and directed. |
| 81 | S & F switch flame proof switch-socket and plug combined in LM6,25Amp,2pin+earth, horizantal pin,250 Volt omplete all as specified and directed. Make:- Sudhir, cat No-SS/OA/1010-3 or equivalent from make mentioned in Appendix \"B\". |
| 82 | M & L forSub main wiring with four single core cable PVCinsulated unsheathed of copper multi strandard conductor FR-LSH cable of size4 sqmm, 1100 votls grade drawing through and including concealed stove enamelled steel conduit 40 mm diamedium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in cement mortar (1:3) and finishig the surface to match with existing surface, etc. complete all as specified and directed. (Note:- Four runs of main cable and one run of earth cable and one run of conduit will be measured as one unit.) |
| 83 | S & FSub main wiring with two single core cable PVCinsulated unsheathed of copper multi strandard conductor FR-LSH cable of size10 sqmm, 1100 votls grade drawing through and including concealed stove enamelled steel conduit 20 mm diamedium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 10 sqmm unsheathed multistranded FR-LSH copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc. complete all as specified and directed. (Note:- Two runs of main cable and one run of earth cable and one run of conduit will be measured as one unit.) |
| 84 | S & F Flame proof MCB Distribution Board, 16 way suitable for fixing MCB with rated bus bar 200 Amp, IP65 & IP66,215 Volt complete with following :-(a) FP MCB TPN 32 Amp-01 (Incoming) (b) FP MCB SP 6 Amp-04 Nos (c) FP MCB SP 10 Amp--02 Nos(d) FP MCB SP 25 Amp--04 Nos |
| 85 | AIR CONDITIONING |
| 86 | Supply, installation, commissioning and testing hi wall split air conditioner units indoor/outdoor unit complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of capacity2 TR complete all as specified and directed. |
| 87 | SPECIAL ITEM OF WORK |
| 88 | Supply,Installation, testing and commissioning FRP induced drought counter flow bottle shape cooling tower with FRP basin, PVC fills, SS sprinkler pipe, FRP body, hot dipgalvanised suction and discharge screen, access ladder, weather proof electric motor, die cast aluminium / FRP blade fan, Motor guard, in let out let,quick fill, drain and over flow nozzle connection for 100TR capacity Air Conditioning plant, water flow rate: 1500LPM, Hot water temperature- 37 C, Cold water temperature 32º C, Wet bulb Temperature-28º C, Diameter/Hight:2800mm/3200mm, Fan diameter/ Nos of Blade: 1500mm/04 Nos, Moror HP/RPM: 5HP/960RPM, including 1.5 Mtr High 3x3 Mtr Platform complete by constructing PCC (1:3:6) block masonry 40cm in width ( all round) in cement mortar 1:6,plaster to exposed surfaces in cement mortar 1:4, filling of soil from ground level to 1.5 m high and top of platform provided with 100mm thick PCC (1:2:4) floor smooth finish using extra cement complete including necessary excavation and earthwork all as specified and directed. |
| 89 | Supply, installation, commissioning and testing FRP induced drought counter flow bottle shape cooling tower withFRP basin, PVC fills, SS sprinkler pipe, FRP body, hot dipgalvanised suction and discharge screen, access ladder, weather proof electric motor, die cast aluminium / FRP blade fan, Motor guard, in let out let,quick fill, drain and over flow nozzle connection for 50TR capacity Air Conditioning plant, water flow rate: 750LPM, Hot water temperature- 37 C, Cold water temperature 32 C, Wet bulb Temperature-28 C, Diameter/Hight:1900mm/2400mm, Fan diameter/ Nos of Blade: 1200mm/04 Nos, Moror HP/RPM: 2HP/960RPM, including 1.5 Mtr High 2x2 Mtr platform complete by constructing PCC (1:3:6) block masonry 40cm in width ( all round) in cement mortar 1:6, plaster to exposed surfaces in cement mortar 1:4, filling of soil from ground level to 1.5 m high and top of platform provided with 100mm thick PCC (1:2:4) floor smooth finish using extra cement complete including necessary excavation and earthwork all as specified and directed. |
| 90 | S & F ERW or Induction butt weld M.S. tube black conforming to IS 1161-1979grade Yst 240, of size 140mm dia including jointing complete all as specified and directed. |
| 91 | S & F ERW or Induction butt weld M.S. tube black conforming to IS 1161-1979grade Yst 240, of size 90mm diaincluding jointing complete all as specified and directed. |
| 92 | M &L for cutting of existing MS pipe of 90 dia and welding, brazing and make tee connection by fabricating the same complete all as specified and directed. |
| 93 | All as per srl item No.88.00above but 150mm dia. |
| 94 | S & F Butterfly valve of 150mm dia complete all as specified and directed. |
| 95 | S & F Butterfly valve of 90mm dia complete all as specified and directed. |
| 96 | EXTERNAL ELECTRIFICATION |
| 97 | Supply, lay and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, LT electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete laying in existing duct and clamping on wall / floor etc. all as specified and directed. |
| 98 | Supply, lay and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, LT electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete laying in existing duct and clamping on wall / floor etc. all as specified and directed. |
| 99 | S & F PVC Insulated, FRLS Round sheathed ,Bright annealed bare copper conductor Heavy duty industrial cable of size 6 sqmm 4 core, suitable for voltage 1100 Volt as per IS 694:1990 complete laying in existing duct and clamping on wall / floor etc. all as specified and directed. |
| 100 | S & F PVC Insulated, FRLS Round sheathed ,Bright annealed bare copper conductor Heavy duty industrial cable of size 10 sqmm 4 core, suitable for voltage 1100 Volt as per IS 694:1991 complete laying in existing duct and clamping on wall / floor etc. all as specified and directed. |
| 101 | S & F 4 way VDB TPNdouble door sheet metal enclosuremade out of CRCA mild steel sheet concealed surface mounting 415Volt, with 200 Amprated bus bar suitable for fixing MCBs, isolators etc. including MCCB of rating 63 Amp, 16 KA, 4 Pole complete all as specified and directed. |
| 102 | Supply and fixing socket DB with 3P+N+E-FP 32 A made out of made out of CRCA mild steel sheet 415 Volt, suitable for fixing MCBs, isolators etc. complete all as specified and directed. |
| 103 | Supply,Installating, testing and commissioningof LT panel indoor type ,size 1000mm X 900 mm X450 mm metal enclosed fixed type,free standing,floor mounting,compartmentalized,modular type suitable for indoor installation,cubical type,factory assembled in bolted design fabricated from 2 mm thick CRCA sheet steel frame work and powder coated, degree of protection IP-54 as per IS-13947,consisting high conductivity copper bus bar of rating 200 amps and of suitable size with heat shrinkable sleeves,fault rating 36 kA for 1 sec, including multifunctional digital voltmeter,ammeter,frequency meter and power factor meterwith comprising the followings:- |
| 104 | MCCB200 Amp, 36 kA,4 Pole Make Legrand Model DXP-250 4202 38-01 NosMCCB 100Amp, 25 kA,4 PoleMake Legrand Model DXP-160 4200 85-02 NosMCCB 63 Amp, 25 kA,4 PoleMake Legrand Model DXP-160 4200 83-01 NosMultifunctional meter L&T WL404010OOO-01 No.RYB Indicator set-01 NoNote:- (i) The MCCBs should be fixed type.(ii) The panel shall complete with all internal wiring and bus bars of suitable ratings.(iii) Cable entries shall from the rear bottom at the back of the panel through gland plates.(iv) System may comprise of main horizontal bus bars and auxilary vertical bus bars, Bus bars/Connection shall be suitably sleeved by heat shrinkable colored sleeves.(v) Panel manufacturer should posses CPRI test certificate of rated capacity(vi) Equivalent component from make given in Appx \"B\"may be incorported |
| 105 | SCHEDULE OF CREDIT RS 106779.5 |