Repair Or Maintenance Of Summer Appliances Window Type, Split Type, Cassette Type Acs And Allied Services At Kashmir House Under Ge New Delhi Repair Or Maintenance Of Summer Appliances Window Type, Split Type, Cassette Type Acs And Allied Services, NEW DELHI-Delhi

Military Engineer Services-MES has published Repair Or Maintenance Of Summer Appliances Window Type, Split Type, Cassette Type Acs And Allied Services At Kashmir House Under Ge New Delhi Repair Or Maintenance Of Summer Appliances Window Type, Split Type, Cassette Type Acs And Allied Services. Submission Date for this Tender is 05-11-2021. Air Conditioner Tenders in NEW DELHI Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

29518962
Corrigendum : Repair Or Maintenance Of Summer Appliances Window Type, Split Type, Cassette Type Acs And Allied Services At Kashmir House Under Ge New Delhi Repair Or Maintenance Of Summer Appliances Window Type, Split Type, Cassette Type Acs And Allied Services
Open Tender
Indian
Delhi
NEW DELHI
05-11-2021

Tender Details

Repair Or Maintenance Of Summer Appliances Window Type, Split Type, Cassette Type Acs And Allied Services At Kashmir House Under Ge New Delhi Repair Or Maintenance Of Summer Appliances Window Type, Split Type, Cassette Type Acs And Allied Services At Kashmir House Under Ge New Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR OR MAINTENANCE OF SUMMER APPLIANCES WINDOW TYPE, SPLIT TYPE, CASSETTE TYPE ACs AND ALLIED SERVICES AT KASHMIR HOUSE UNDER GE NEW DELHI
Sl. No. Item Description
1Labour for checking and attending complaints of ACs,Refrigerators, etc. of any capacity, rectification of minor defects and make the equipment functional complete all as specified and directed. Note:- (a)Any parts required forreplacementshall be measured and paid separately under respective items (b)The contractor should detail minimum one AC Mechanic & one helper to attend complaints in Kashmir House .The complaint should be attended on same day. (c))If the complaint not attended/not completed on same dayrecovery will be done as follows:- (i) For first day Rs.200/- (ii)For second day Rs.300/- (iii)For every next day Rs.500/-
2Servicing of Window type AC 1.5/2 Ton capacity ofany make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checkingof electric circuit for smooth functioning of AC complete all as specified and directed.
3All as per item No 2.00 here-in-before but Split type AC of any type and 1.5/2 Ton capacity complete all as specified and directed.
4Servicing of three phase cassette type split AC 3.5 to 4.0 Ton capacity of any make / model with indoor and outdoor unit by taking out the AC, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed. Note: Unserviceable spare parts, required to be replaced, shall be measured and paid separately under respective items.
5Supply only running capacitor combination50 mfd + 6 mfd 230 Voltfor AC upto 4.00 Ton complete all as specified and directed.
6Supply only Running capacitor 6 mfd 230 voltcomplete all as specified and directed.
7Supply only Running capacitor 4 mfd 230 voltcomplete all as specified and directed.
8Supply & charging gas refrigerant R-22 /410 A/ or as existing to window type/Split type/Cassette/Package type AC up to 4 Ton capacity including removing of leakage if any and testing complete all as specified and directed.
9Supply only starting relay suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
10Supply onlyover load protector suitable for 1.5 Ton capacity AC complete all as specified and directed.
11Supply only thermostat switch suitable for 1.5/2 Ton capacity ACcomplete all as specified and directed.
12Supply only item ofstarting relay suitable for 4.0 Ton capacity AC complete all as specified and directed.
13Supply only item ofover load protector suitable for 4.0 Ton capacity AC complete all as specified and directed.
14Supply only item ofthermostat switch suitable for 4.0 Ton capacity AC complete all as specified and directed.
15Supply and fixingin replacementreciprocating type compressor 1.5 Ton capacity of the same make and model as per existing make of ACs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed.
16Supply and fixingin replacementreciprocating type compressor 2 Ton capacity of the same make and model as per existing make of ACs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed.
17Supply and fixingin replacementRotarytype compressorupto 2 Ton capacity of the same make and model as per existing make of ACs, refixing including brazing work etc, pressuretesting & establishing vacuum for dehydration complete all as specified and directed.
18Supply and fixingin replacement ofthree phase compressor suitable for 3.5 to 4.0 Ton capacity of the same make and model as per existing make of ACs complete all as specified and directed.
19Supply only wiring kit suitable for 1.5/2 Ton capacity AC complete all as specified and directed.
20Supply only air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity, window type ACs complete all as specified and directed.
21Supply only air filter synthetic/ nylon as per existing size and shape suitable for 1.5/2 Ton capacity split type ACs complete all as specified and directed.
22Supply only item ofair filter synthetic / nylon type as per existing size and shape suitable for 3.5/4.0 Ton capacity cassette type split ACs complete all as specified and directed.
23Supply only new fan motor (indoor/outdoor) 1/4, 1/5 HP single/double shaft as per existing model suitable for Splittype ACs 1.5/2 Ton capacity complete all as specified and directed.
24Supply only in replacementnew DC fan motor (indoor/outdoor) 1/4, 1/5 HP single/double shaft as per existing model suitable for Splittype ACs 1.5/2 Ton capacity complete all as specified and directed.
25Supply only fan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton ACs of any make/type complete as per requirement on site all as specified and directed.
26Supply only DCfan motor single/double shaft as per existing model suitable for 3.5/4.0 Ton cassette typeAC"s of any make/type complete as per requirement on site all as specified and directed.
27M&Lfor rewinding of fan motor suitable for ACs up to 4 Ton capacity with super enameled copper winding wire of same gauge including replacement of insulating material, bushes and shaft complete all as specified and directed.
28Supply only PVC insulatedflexible copper conductor 3 core 1100V Grade of size 2.5 sqmm complete all as specified and directed.
29Supply only PVC insulatedflexible copper conductor 3 core 1100V Grade of size 4.0 sqmm complete all as specified and directed.
30Supply only condensor fan blade made out ofplastic suitable for upto 2 Ton capacity window type ACs complete all as specified and directed.
31Supply only condensor fan blade made out ofplastic suitable for upto 2 Ton capacity split type ACs complete all as specified and directed.
32Supply only condensor fan blade made out of aluminium suitable for upto 4.0 Ton capacity cassette type split ACs complete all as specified and directed.
33Supply only evaporatingair blower made out ofsuitable for upto 2 Ton capacity for window type ACs complete all as specified and directed.
34Supply only evaporatingair blower made out of suitable for upto 2 Ton capacity for split type ACs complete all as specified and directed.
35Supply only indoor air blower made out ofsuitable for upto 4.0 Ton capacitytype split ACs complete all as specified and directed.
36Supply only synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split AC units complete all as specified and directed.
37Supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split AC units complete all as specified and directed.
38Supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9 mm ("3/8") for refrigerant copper piping of split AC units complete all as specified and directed.
39Supply onlyin replacement of synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16 mm ("5/8") for refrigerant copper piping of split AC units complete all as specified and directed.
40M&L for replacement of front grill suitable for window type ACs upto 2 Ton capacity of any make of AC as per existing size and shape complete all as specified and directed.
41M&L for replacement of reverse valve system suitable to 1.5/2 Ton split/window AC for heating option complete all as specified and directed. (Note : Gas charging shall be paid and measured under respective item)
42Supply onlycopper tubing heavy duty inner dia 6 mm (1/4") for refrigerant for ACs complete all as specified and directed.
43Supply onlycopper tubing heavy duty inner dia 13mm (1/2") for refrigerant for ACs complete all as specified and directed.
44Supply onlycopper tubing heavy duty inner dia 9 mm (3/8") for refrigerant for ACs complete all as specified and directed.
45Supply onlycopper tubing heavy duty inner dia 16 mm (5/8") for refrigerant for ACs complete all as specified and directed.
46Supply onlycondensing coil suitable for 1.5/2 Ton splittype ACs as per existing size/shape and as per existing make complete all as specified and directed.
47Supply onlyevaporating coil suitable for 1.5/2 Ton splittype ACs as per existing size/shape and as per existing make complete all as specified and directed.
48Supply onlybrass flare nut/connector heavy duty of size 6 mm/9 mm (1/4", 1/2") as per existing make complete all as specified and directed.
49Repair to control processing board (Remote control kit) with hand set including replacement of current transformer, ICs, diods, resistances, sensors etc complete for 1.5/2 Ton split type ACs of any make & model complete all as specified and directed.
50Repair to control processing board (Remote control kit) inverter typewith hand set including replacement of current transformer, ICs, diods, resistances, sensors etc complete for 3.5/4 Ton split type ACs of any make & model complete all as specified and directed.
51Supply and fixingin replacement split type AC 1.5/2 Tonindoorunit kitwithPCB complete withsensor complete with fixing plate suitable to non inverter type AC complete all as specified and directed.
52Supply and fixingin replacement split type AC 1.5/2 TonindoorPCB unit kitcomplete withsensor complete with fixing plate suitable to inverter type AC complete all as specified and directed. Make:- Carrier, Blue star, Napolean & Totaline
53Supply and fixingin replacement split type AC 1.5/2 Ton outdoor unit kit complete with compressor, condensor coil,condensor fan with blade and sensor suitable to non inverter typeexisting model and make of AC complete all as specified and directed. Make:- Carrier, Blue star, Napolean & Totaline.
54Supply and fixingin replacement split type AC 1.5/2 Ton outdoor unit kit complete with compressor, condensor coil, condensor fan with blade and sensor suitable toinverter typeexisting model and make AC all as specified and directed.Make:- Carrier, Blue star, Napolean & Totaline.
55Supply and fixingin replacement window AC kit 1.5/2 TonPCBwith sensorcomplete with condensing coil, fan motor, blower and motor, compressor and grill complete suitable to non inverter type existing model and make of AC complete all as specified and directed. Make:- Carrier, Napolean & Skoda.
56Supply onlyair direction changer louver motor (swing motor) suitable for split type ACs as per existing make and model complete all as specified and directed.
57Supply only in replacement cordless Remote for inverter type ACsHot & cool suitable for 1.5 Ton AC as per sample complete all as specified and directed.
58Supply onlyin replacement cordless Remote for ACssuitable for 1.5 Ton AC as per sample complete all as specified and directed.
59Servicing of Refrigerators of 165 to 310 ltrcapacitysingle door ofany make / model by cleaning of condensing coil with wire & brush to remove dust includingcheckingof electric circuit for smooth functioning complete all as specified and directed.
60Supply and fixingin replacementnew compressor suitable for 280/310ltr capacity refrigerator reciprocating type complete all as specified and directed.
61Supply and fixing of monkey menace protection device with PVC spikes size as per sample complete all as specified and directed.
62Taking down AC of any type, any capacity and any make, dismantling of copper pipe, transportation to workshop for carrying out necessary repairwork, transportation back to location of installation , reinstallation/refixing in position after complete repairs as required and making functional includingtesting complete all as specified and directed.
63Supply and fix drain pipe of any size suitable for split AC of capacity 1.5/2/3.5/4 TR as per sample complete all as specified and directed.
64M&L in replacement for MetalClad Plug & socket board SP&N enclosure with single pole and earth metal plug & socket suitable for 20 Amps MCB AC, 220 V, 50Hz complete all as specified and directed.
65M&L for checking and attending complaints of maintenance contract for VRF units capacity 32 HP installed at South Hutments including replacement of fan motor, compressor as per existing , brazing to joints. gas top up, repair to display along with connected accessories, short circuiting of wiring rectification and its replacement, including repair/ replacement to LCD display servicing or descaling of cooling fins and removal of dirt by pressure washing etc. complete all as specified and directed. Note: Entire work shall be carried out by OEM only
66Supply, installing, testing and commissioning in replacement factory made and tested Outdoor type, platform mounted, Phase Sequence Corrector of capacity 63 A , 3 Phase 4 Wire, 415 volts, 50 Hz, platform mounted. The Phase Sequence Corrector shall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick Stainless Steel Sheet 316L thick & suitable frame work/ support made out of 75 mm Stainless Steel flat channel, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:- Make:- Havells/ Schneider / ABB/ L&T/Universal Switch Gear Control. Note- Work includes civil work like excavation and preparation of PCC Plinth
67Item No. 66.00 contd.. Phase Sequence Corrector of capacity 63 A , 3 Phase 4 Wire, 415 volts, 50 Hz with facility to change over from automatic to manual, microprocessor release (over load, short circuit, instantaneous Single phasing, Phase reversal ), pre trip alarm and individual fault indication LED with fully rated neutral with inbuilt protection. The over load release shall be adjustable type, Protection:-Avoid damages during Phase sequence changes or reversal. • The Sequence Corrector will switch off, during the Single Phasing or Imbalance voltage occur & later, Auto-reset after restoration. • No break downs of Three phase system due to the change in sequence. • Bye Pass Selector switch in case of controller Faulty.
68Item No. 67.00 contd.. The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Certification Short Circuit withstand strength should be 50kArms for 1.0 Sec with initial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
69Supply, install, commissioning and testing in replacement of LT panel board outdoor type floor mounted, factory made, powder coated made out of outside body of 2.00 mm thick Stainless Steel Sheet 316L thick & suitable frame work/ support made out of 75 mm Stainless Steel flat channel,, locking arrangement, front side and rear side opening arrangement of suitable size, Incl mounting onduly grouting or welded on floor. Aluminium bus bar TPN of 600 A for MCCB to all feeders to accommodate following items:- (a)Incoming MCCB 250 Amp 50 kA 4 pole, microprocessor based energy release-01 no Cat No HMT250NR Hageurs, Equivalent in Legrand/ Schneider (b) Outgoing MCCB 100 amp 40 KA 3pole,microprocessor based energy release-04 no HNS100 NR (c)RYB indication for each incoming & outgoing supplies-01 set (d)Voltmeter, amp meter, digital type with CTs &selector switch-01 set (e)Termination of all cables with suitable size thimble and gland-1job (f) Termination of all cables with suitable size thimble and gland-1 job . Make for SS enclosure :- Havells/ Schneider / ABB/ L&T/Universal Switch Gear Control. Note- Work includes civil work like excavation and preparation of PCC Plinth
70Supply, install, commissioning and testing in replacement of LT panel board indoor type floor mounted of factory made powder coated made out of outside body of 2.00 mm thick Stainless Steel Sheet 316L thick & suitable frame work/ support made out of 75 mm Stainless Steel flat channel, locking arrangement, front side and rear side opening arrangement of suitable size, Incl mounting onduly grouted or welded on floor. Aluminium bus bar TPN of 600 A for MCCB to all feeders to accommodate following items:- (a)Incoming MCCB 200 Amp 50 KA 4 pole,microprocessor based energy release -01 no.Cat No HMT250NR Haguer, equivalent in Legrand/ Schneider (b) Outgoing MCCB 100 amp 40 KA 3pole -04 no microprocessor based energy release -01 no.Cat No HNS100NR Hager, equivalent in Legrand/ Schneider (c) Changeover on load for open execution 200 Amp (d)RYB indication for each incoming & outgoing supplies-01 set (e)Voltmeter, amp meter, digital type with CTs &selector switch-01 set (f)Termination of all cables with suitable size thimble and gland-1job (g) Termination of all cables with suitable size thimble and gland-1 job . Make for SS enclosure :- Havells/ Schneider / ABB/ L&T/Universal Switch Gear Control . Note- Work includes civil work like excavation and preparation of PCC Plinth
71Collecting the U/S single phase voltage stabilizer of capacity from 02 KVA to 05 KVA from MES complaint cell to local workshop/in-situ for repair and open the stabilizer taking out u/sspare incl replacement of the same with new one, incl testing complete all as specified and directed. (Note : Replacement of spare parts will be measured and paid separately as per Schedule as supply only )
72Supply only relay for voltage stabilizer suitable for 2 KVA to 5 KVA capacity stabilizer complete all as specified and directed.
73Supply only printed circuit board (PCB) suitable for 5 kVA capacity stabilizer complete all as specified and directed.
74Supply only main transformer suitable for 5 kVA capacity stabilizer complete all as specified and directed.
75Supply only connector block porcelain 4 way suitable for 30 Amps capacity complete all as specified and directed.
76S&F in replacement plug top3 pin, 15 Amps, 230 volts, 50 Hz AC complete all as specified and directed.
77M&L for taking down Split/Window AC and shifting from one position to other within the premises with copper tubing indoor plate and copper tubing with all accessories with making good the disturbed surfaces with cement plaster and POP complete all as specified and directed.
78S&F submain wiring in replacement with two runs PVC insulated unsheathed FRLS stranded copper conductor cable of size 4.0 Sqmm alongwith one run of PVC insulated unsheathed stranded copper conductor cable of size 2.5 sqmm as earth wire connected to earth dollyfixed on surface of wall/ceiling/in concealed PVCconduits complete including cutting chases and making good to walls at disturbed area all as specified and directed. Note :- Two run of 4.0 sqmm copper conductor cable,one run of 2.5 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
79All as per item No 78.00 here-in-before but size of cable 2 x6 sqmmcomplete along with cable 1x2.5 sqmm FRLS type for continuous earth wire and connected to common earth dolly complete all as specified. Note :- Two run of6 sqmm copper conductor cable, one run of 2.5 sqmm copper cable and one run of PVC conduit shall be measured as one unit length
80Supply only factory made load line DBs double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 12 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as outgoing complete all as specified and directed.
81Supply only factory made load line DBs double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as outgoing complete all as specified and directed.
82Supply only MCCB TP 125 Amp, 25kA thermal type complete all as specified and directed.
83Supply only MCCB TP 160 Amp, 25kA thermal type complete all as specified and directed.
84Supply only MCB SP 40-63 Amp, 10kA complete all as specified and directed.
85Supply & fix non-metallic 20 mm external dia PVC rigid conduit concealed on surface to wall / ceiling for drain out of water from split type and window typebut inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks up to outdoor unit to ground floor level complete all as specified and directed.
86Supply only in replacement of MCB SPN 20-32 Amp, 10kA complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail