Day To Day Maintenance Repairs To Internal External Electric Supply, Water Supply, Dg Set, Lightning Protection System, Security Street Lights, Air Conditioners At Cgae, Nedumbassery, Kochi Day To Day Maintenance Repairs To Internal External Ele, KOCHI-Kerala

Military Engineer Services-MES has published Day To Day Maintenance Repairs To Internal External Electric Supply, Water Supply, Dg Set, Lightning Protection System, Security Street Lights, Air Conditioners At Cgae, Nedumbassery, Kochi Day To Day Maintenance Repairs To Internal External Ele. Submission Date for this Tender is 04-11-2021. Lightening Protection Device Tenders in KOCHI Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

29510670
Corrigendum : Day To Day Maintenance Repairs To Internal External Electric Supply, Water Supply, Dg Set, Lightning Protection System, Security Street Lights, Air Conditioners At Cgae, Nedumbassery, Kochi Day To Day Maintenance Repairs To Internal External Ele
Open Tender
Indian
Kerala
KOCHI
04-11-2021

Tender Details

Day To Day Maintenance Repairs To Internal External Electric Supply, Water Supply, Dg Set, Lightning Protection System, Security Street Lights, Air Conditioners At Cgae, Nedumbassery, Kochi Day To Day Maintenance Repairs To Internal External Electric Supply, Water Supply, Dg Set, Lightning Protection System, Security Street Lights, Air Conditioners At Cgae, Nedumbassery, Kochi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Oct-2021 Amendment and Revised BOQ BOQ 28-10-2021
2 28-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 38000.0 /-
Tender Value
INR 19 Lakhs /-

BOQ Items

Name of Work:DAY TO DAY MAINTENANCE/REPAIRS TO INTERNAL/ EXTERNAL ELECTRIC SUPPLY, WATER SUPPLY, DG SET, LIGHTNING PROTECTION SYSTEM, SECURITY/ STREET LIGHTS, AIR CONDITIONERS AT CGAE, NEDUMBASSERY, KOCHI8779/E8
Sl. No. Item Description
1Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
2Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FR) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable(FR) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-.
3(a ) onelight point controlled by one switch 5 Amps
4(b ) onefan pointpoint controlled by one switch 5 Amps
5(c) One 3pin socket outlet 5 Ampson Independent board
6(d ) One 3pin socket outlet 5 Ampsonsame board
7( e) One bell pointcontrolled by one bell push
8All as per Item No. 2 above but with 4sq mm PVC insulated copper conductor cable(FR) including4 sq mmPVC copper conductor used as earth wirefor power point on independent board for One 3 pin socket outlet, 15 Amps.
9Supply and fix Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
10Supply and fix Socket outlet 2 in 1, 5 Amps flushtype230 Volts, AC, with ISI mark complete all as specified and directed.
11Supply and fix SwitchSocket Combination2 in 1, 5 Amps /16 Ampsflushtype230 Volts, AC, with ISI mark complete all as specified and directed.
12Supply and fixSocket outlet 2 in 1, 3pin 5 Amps flushtype230 Volts, AC, with ISI mark complete all as specified and directed.
13Supply and fix Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
14Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead HT/LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge. Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid. (b) The spares required for the rectification of fault shall be measured under items 15 to 39. (c) 5 Nos complaints will be treated as one job
15Supply only Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed.
16Supply only SwitchSocket Combination2 in 1, 5 Amps flushtype230 Volts, AC, with ISI mark complete all as specified and directed.
17Supply only SwitchSocket Combination2 in 1, 5 Amps /16 Ampsflushtype230 Volts, AC, with ISI mark complete all as specified and directed.
18Supply only Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed.
19Supply only Bell push 5 Amps one way complete all as specified and directed.
20Supply only Electronicfan regulator 230 volts, step type,socket type, hum free 120 watt ISI Marked complete all as specified and directed.
21Supply onlyCeiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed.
22Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fittingcomplete all as specified and directed.
23Supply only of Modular switch, one way, 6Amps complete all as specified and directed.
24Supply only Modular switch, one way, 16Amps complete all as specified and directed.
25Supply only Modular switch, two way, 6 Amps complete all as specified and directed.
26Supply only Modular socket outlet, 5 Amps, 2 and 3 pin combined complete all as specified and directed.
27Supply only Modular socket outlet, 5 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed.
28Supply only Modular fan regulator 230 volts, step type, 120 wattcomplete all as specified and directed.
29Supply only Modular Bell push, 6 Amps complete all as specified and directed.
30Supply only Modular SwitchSocket Combination 16 Amps 6 pin complete all as specified and directed.
31Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed.
32Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed.
33Supply only LED tube light batten 20 watt, 240 volts complete all as specified and directed. Make: Bajaj Cat part No BCLSB 20 WH or equivalent in Havells/Philips/Crompton Greaves.
34Supply only LED bulb 9 watts, 230 volt complete all as specified and directed. Make: CELS Cat part No CLLC-LP-10 or equivalent in Philips/Bajaj/Surya.
35Supply and fix in repairs,LED recess suitable for false ceiling 2 ft X2 ft,36 watts , 240 volts AC supply complete all as specified and directed. Make : Bajaj / Havells/Philips/Crompton Greaves.
36Supply only LED mirror light of 10 Watt complete all as specified and directed. Make:Cat No BCLSB 10 WH of Bajaj or equivalent in HavellsPhilips/Bajaj/Surya.
37Supply only MCB single pole & neutral240 volt C curve 10 KA 63 Amps capacity IP 20 transparent lebel holder fully insulated safety shutters completeincluding suitable sizecopper lugs complete all as specified and directed.
38All as per ser item No 37 above butMCB TPN415 volt C curve 10 KA 40 Amps capacity complete all as specified and directed.
39All as per ser item No 37 here-in-before but MCB single pole, 6 to 32 Amp 240 voltB curve 10 KA complete all as specified and directed.
40Material and labour for Sub main wiring using two runs of single corePVC insulated cable(FR) 4 sqmm copper conductor multi stranded and one run of 4 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note- 3 run of 4 sqmm PVC copper wire and One run of PVC casing capingshall be measured and paid as oneunit.
41Material and labour for Sub main wiring using two runs of single corePVC insulated cable (FR) 6 sqmm copper conductor multi stranded and one run of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC casing and caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC casing caping shall be measured and paid as oneunit.
42Material and labour for Sub main wiring using four runs of single corePVC insulated cable(FR) 6 sqmm copper conductor multi stranded and two runs of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including non metallic PVC conduit pipe ISI marked of size 25 sq mm including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-6 run of 6 sqmm PVC copper wire and One run of PVC conduit shall be measured and paid as oneunit.
43Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 415 volts, MCBs used as incommerDouble door, flush to wall complete all as specified and directed .
44All as per ser item No 43 above but SPN 4 way, double door 240 volts complete all as specified and directed .
45All as per ser item No 43 above but SPN 8 way, double door 240 volts complete all as specified and directed .
46Supply and fix in repairs single pole andneutral enclouser with a two pin andearth plug and socketcomplete with and including one MCB single pole 20 Amps complete all as specified and directed.
47Taking down fan of any type and size after disconnecting, depositing to store yard and Hanging/fixing onlyafter repair/reconditioning fan of any type and size all as directed. NOTE: Repair and reconditioning of fan shall be measured and paid separately under Item Nos.48 to 52.
48Collectingunserviceable ceiling fan 1200mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceablewinding from fan stater & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed. Note : (i) Taking down and refixing after repair work shall be measured and paid under Item No.40 above. (ii) Spare such as Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps etc shall be measured & paid separatetly under item Nos.53 to 60.
49All as per item No48 above but exhaust fan 300 mm sweep
50All as per item No 48 above butexhaust fan 450 mm sweep
51Material and Labour for Scraping down old paint of ceiling fan of any size 1200 mm sweep complete body & blade including down rod filling the cavitieswith filler and making smooth surfaceby applying sand paper painting the ceiling fan by meansspray gun/brush with synthetic enamel white paint complete all as specified and directed.
52Material and Labour for lathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed.
53Supply only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL
54Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample
55Supply only Gun metal bush for ceiling fan complete all as specified and directed.
56Supply only Shackle type rubber reel,"U" clamps, bolts,split pin & washer complete all as specified and directed.
57Supply only Canopy top/bottom suitable for 20mm dia rod complete all as specified and directed.
58Supply only Down rod 300mm long of size 20mm dia ISI marked complete all as specified and directed.
59Supply only Fan blades suitable for 1200mm sweep fan make & type complete all as specified and as directed .
60Supply only 1.2mm thick mild steel top/bottom cover for ceiling fan any size and make complete all as specified and as directed .
61Supply and fixing in repairs Exhaust fan blade (three leaves) of 450mm sweep complete as per sample of the following sizes complete all as specified and as directed .
62All as per item No 61 above but for 300mmsweep
63Supply and fixing in repairs Exhaust fan clamps including frame and louvers with rubber bush, etc suitbale for 450mm sweep complete as per sample complete all as specified and as directed .
64All as per item No 63 above but for 300mmsweep.
65Supply and fixing in repairs Wall mounting fan blade 400 mm sweep (three leaves)and make suitable for fixing and as per sampleof existingfancomplete all as specified and directed.
66Supply and fixing in repairs oscillating mechanism suitable for wall mounting fan any make and typeall complete all as specified and as directed.
67Supply and fixing in repair of Exhaust fan Motor of 450mm sweep heavy duty complete as per samplecomplete all as specified and as directed.
68All as per item No 67 above but for 300mmsweep.
69Material and labour for servicing including cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil forsplittype AC ofanymake/ capacity aftertaking down the whole unit and refixingat the existing locationor any other new location after servicing allas specified and directed. Note: Spare parts shall be measured and paid separately under relevant item.
70Supply and fix in repairs Printed Circuit Board suitable for 2TR CapacitySplit Unit Air Conditioners including remote, etc. all as specified and as directed. NOTE: Make of PCB & remote shall be of existing manufacturer as compatible with the AC.
71Supply and fix in repairs Printed Circuit Board suitable for 1.5TR CapacitySplit Unit Air Conditioners including remote, etc. all as specified and as directed. NOTE: Make of PCB & remote shall be of existing manufacturer as compatible with the AC.
72Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed. Make : LG/ Voltas/ Samsung
73Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer complete all as specified and as directed. Make : LG/ Voltas/ Samsung
74Supply and fix in repairs contactoor suitable for 2 TR Capacity Split type Air Conditioners complete all as specified and directed. Make : LG/ Voltas/Goderj
75Supply and fix in repairs AC blower fan motor for ACsuitable for 2 TR AC suitable operate on 230 Volt AC supply at 50 Hz complete all as specified and directed.
76Supply and fix in repairs Thermostat switch for water cooler/Window AC complete all as specified and directed.
77Supply and fix in repairs Drier stainer filter suitable for AC/Water cooler/Refrigertor complete all as specified and directed.
78Supply and fix in repairs Capacitor 45 MFD complete all as specified and directed.
79Supply and fix in repairs Capacitor 50 MFD complete all as specified and directed.
80Supply and fix in repairs insulationNytrile foam insulation suitable for 5/8 inch copper tube as per site requirement of approved makeall as specified and directed .
81Supply and fix in repairs insulationNytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved makeall as specified and directed .
82Supply and fix in repairs Copper tube5/8 inch size as per site requirement of approved makeall as spd and directed .
83Supply and fix in repairs Copper tube 1/4 inch size of approved makeall as specifiedand directed .
84Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs complete all as specified and directed. Make :LG/ Voltas/ Samsung
85Supply and fix in repairsblower fan motor water cooler capacity 40/80 suitable operate on 230 Volt AC supply at 50 HZ complete all as specified and directed.
86Supply and fix in repairsstarting relay suitable for water cooler capacity 40/80, operate on 230 Volt AC supply at 50 HZ complete all as specified and directed.
87Supply and fix in repairs Evaporator unit (indoor unit ) complete suitable for 2 TR Capacity Split type Air Conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/ Voltas/Goderj
88Supply and fix in repairs Condensing (Out door) unit complete including compressor, etc. suitable for 2 TR Capcity Air conditioners 5 star rating with latest ISEER complete all as specified and directed. Make : LG/Voltas/Goderj
89Supply and fix in repair Bracket stand suitable for 2 TR Capacity Split type AC including Fastners, etc. Complete all as specified and directed.
90Supply and fix in repairsblower fan motorsuitable for deep freezer capacity 320 ltr, operate on 230 Volt AC supply at 50 HZ complete all as specified and directed.
91Supply and fix in repairsstarting relaysuitable for refrigerator capacity 215 ltr capacity complete all as specified and directed.
92Supply and fix in repairsthermostat switchsuitable for refrigerator capacity 215 ltr capacity complete all as specified and directed.
93Supply and fix in repairsdoor gasketsuitable for refrigerator capacity 215 ltr capacity complete all as specified and directed.
94Supply and chargingR-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling applincescomplete all as specified and as directed.
95Supply and chargingR-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces complete all as specified and as directed.
96Excavation in trenches in soft/loose soil not exceeding 1.5 mtrwide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottomsurfaces to required level complete all as specified and directed.
97Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding25 cm complete all as specified and as directed.
98Removing excavated soil and depositing to the sides and returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil after cable is laid complete all as specified.
99Material and labour for providing dry screened river sand as in sand cushioning to under groundcable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid.
100Supply and laying cable protection cover un- reinforced precast concrete cable covers class LV, type-1 flat size 250mmx150mmx40mm for cable protection complete all as specified laid perpendicular to cable as per directed.
101Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 50 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed.
102All as per item No 101 above but of size 35 Sqmm 3.5 core.
103All as per item No 101 above but of size 25 Sqmm 3.5 core.
104All as per item No 101 above but of size 16 Sqmm 4 core.
105All as per item No 101 above but of size 10 Sqmm 4 core.
106Material and Labour for 80 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
107Material and Labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed.
108Supply & Fix in repairs MCCB 4 pole 415 Volts adjustable type of capacity 63 Amps, 10 KA breaking capacity fixed properly at directed location and connecting/testing complete all as specified and directed. Make: Cat part NoIHLE1ABF0063 of Havells or Equivalent in L&T / Legrand.
109All as per Item No 108 here-in-before but of capacity 100 Amps, 10 KA breaking capacity complete all as specified and directed Make: Cat part NoIHLE1ABF0100# of Havells or Equivalent in L&T / Legrand.
110Supply & Fixin repairs MCCB 4 pole 415 Volts adjustable type of capacity 125 Amps, 25 KA breaking capacity fixed properly at directed location and connecting/testing complete all as directed. Make: Cat part NoIHLASF00125# of Havells or Equivalent in L&T / Legrand.
111Supply and fixing shock treatment chartduly framed using 1stclass hard wood frame size 25mmx15mm treated french polish, mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs with 5mm thick plain glass, the area of board 1.20 Square Metre complete all as specified and directed.
112Supply and fix in repairs Copper Air termination rod 12 mm dia single pointed 300mm longalong withbase plate welded at bottom of termination rod, of size 10 cm longfabricated out of 32 x 6 mm thick Copper strip along with making 9mm dia for fixing in fastners complete all as specified.
113Supply and fix in repairs aluminium strip 25x3 mm with saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed.
114Supply and fix in repairs GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed.
115Supply and fix in repairs LED Aviation light with enciosureof ABS material, 50 Hz, IP-40 complete all as specified and directed. Make: BGAV302LED of Bajaj or equivalent in Crompton/Havells/Philips
116Material and labour for general servicing of VCB of capacity 630 Amp by drawing out the VCB, removing the dust, general servicing of the mechanism such as lubricating and applying jelly, cleaning the insulators, providing new nuts and bolts etc and recaliberation of relay, remove moisture, replace unserviceable relay, batteries if any, for auxillary supply, re-installing the VCB in its original position, testing and commissioning etc complete all as specified and as directed.
117Material and labour for general servicing of OCB of capacity 250 Amp by drawing out the OCB, removing the dust, general servicing of the mechanism such as lubricating and applying jelly, cleaning the insulators, providing new nuts and bolts etc and recaliberation of relay, remove moisture, replace unserviceable relay, batteries if any, for auxillary supply, re-installing the VCB in its original position, testing and commissioning etc complete all as specified and as directed.
118Dehydration / filtration of transformer oils of transformer/switch gears to achive die-electric strength not less than 40Kv for 1 miniute at 4mm gap as per relevent IS using portable filteration plant including testing of oil for die electric strength before and after filtration complete all as specified and directed. Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electricity for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor.
119Supply and topping up new transformer oil into conservator tank/body tank of transformer using portable filtration plant and directected. Note:- (i) The transformer oil for topping up shall be with di electric strength more than 40kv for 1 miniute at 4mm gap. (ii) Oil shall be supplied at site in sealed barrel.
120Supply and fix in repairs breather assembly suitable for out door type transformer including taking down u/s from the transformer complete all as specified.
121Supply and filling silica gel inside breather assembly of transformer complete all as specified and directed.
122Supply and fix danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters figures and conventional skull and bones in signal red clour and fixed with MS clamps bolts ans nuts of approved size for HT 25x20 cm size complete all as specified and directed.
123Supply and fix in repairs LED Street light fitting 20 Watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP66 protectioncomplete all as specified and as directed. Make:Cat No CLLC-SL-SS-20 of CELS or equivalent in Crompton/Havells/Philips
124Supply and fix in repairs LED Flood/Focus light fitting 50 Watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP66 protectioncomplete all as specified and as directed. Make:Cat No CLLC-FL-50 of CELS or equivalent in Crompton/Havells/Philips
125Cleaning and preparation of old painted surface of steel pole 9 mtr long excluding planting depth completeand painting with one coat of aluminium paintand makingblack and white strips with synthetic enamel paint30 cm height,each alternative strips ,up to 1.5 mtr height and writing poleNos and applying one coat of cement base paint on PCC coping complete all as specified and as directed.
126Taking out unserrviceable earthing completely and providing Earthing complete with GI earth plate electrode 600 x 600 x 6.0mm buried directly in ground vertically to a depth not less than 2.25 M below GL with top edge of the earth plate not less than 1.5 M below normal GL connected with GI strip 32x6mm by means of bolts, nuts check nut and washers of GI and earth strip protected by GI pipe 40mm bore light grade and watering pipe 20mm bore GI pipe medium grade including one test point for testing purpose with funnel and connected to switch/control board upto 7.5m away from earth electrode including earth work, PCC (1:3:6) type C-1 chamber, RCC (1:2:4) type B-1cover slab 50mm thick with 8mm dia TMT bars reinforcement both ways at 140mm C/C, charcoal, salt, water pipe, wire mesh, lugs etc and testing complete all as applicable and as per Plate No.3 of SSR 2009 complete all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 50mm dia light grade GI protection pipe for earth lead etc., complete.
127Material and Labour for general servicing of Diesel Engine ofDG set including greasing, lubrication, calibratiuon of PT pump etc of DG sets of capacity of 100KVA, after replacement of unservicable parts including necessary lathe work fixing, testing the DG set on full load all as directed Note: (a) All T&P items should be brought at site by the contractor. (b) Grease,lubrication are to be measure in general servicing charges of DG set and no extra cost will be paid by Deptt to the contractor. (c) Parts to be replaced shall be measured and paid separately. The makes of spares shall be of respective DG set manufacturer and as approved by Engineer in charge conforming to the OEM machine. (d) The rate quoted shall be excluding servicing of alternator & selt starter which shall be measured and paid separately under relevent items here-in-after. (e)The general servicingjob works also inclusieve of the following mentioned from (i) to (viii) complete in all respect up to the satisfaction of engineer-in-charge.
128(i) Caliberation of Fuel injection pump (FIP) (ii) Taking out the Self starter to the repair shop and servicing works like replacement of brushes, replacement of burnt wire etc. (iii) Taking out the Fuel tank, removing all the sediments from the tank, pressure cleaning, final cleaning with suitable cleaning materials and chemicals/lotion drying, welding and other repair work for any damage to tank, testing for leakage and refixing complete. (iv) Taking out the radiator, removing all the sediments from the radiator tubes, pressure cleaning, final cleaning with suitable cleaning materials and chemicals/lotion, drying, welding and other repair work for any damage to tank, testing for leakage and refixing complete. (v) Dismantling old unservicable Air cleaner elements and supply and fixing new Air cleaner elements inner and outer including dust cap recommended by the maunufacturer complete. (vi) Dismantling old unservicable oil filter elements and supply and fixing new oil filter recommended by the maunufacturer complete. (vii) Dismantling old unservicable fuel filter elements and supply and fixing new fuel filter recommended by the maunufacturer complete. (viii) Cleaning of carbon from silencer pipe and exhauist pipe and two coats od aluminium paint over one coat of red oxide primer.
129Supply only cup injector suitable for DG set 100 KVA complete all as specified and as directed .
130Supply only injector spring suitable for DG set 100 KVA complete all as specified and as directed .
131Supply onlyseal "O" ring suitable for DG set 100 KVAcomplete all as specified and as directed .
132Supply only Barrel and Plunger suitable for DG set 100 KVAcomplete all as specified and as directed .
133Supply only Seat injector suitable for DG set 100 KVA complete all as specified and as directed .
134Supply onlyValve intake suitable for DG set 100 KVAcomplete all as specified and as directed .
135Supply only Valve Exhaust suitable for DG set 100 KVA complete all as specified and as directed .
136Supply only Tube water transfer for DG set 100 KVA complete all as specified and as directed .
137Supply only Gasket exhaust manifold complete all as specified and as directed .
138Supply only Governer weight for DG set 100 KVA complete all as specified and as directed .
139Supply only Carrier weight for DG set 100 KVA complete all as specified and as directed .
140Supply only Pin pivot for DG set 100 KVA complete all as specified and as directed .
141Supply only generator battery lead set of copper PVC insulated standard (heavy duty) for DG set complete all as specified and as directed
142Supply only Grease of standard make complete all as specified and directed.
143Supply only Lubricating oil (10W40) complete all as specified and directed. Make : Castrol/Hindustan Petroleum/Indian oil
144Supply only Coolant oil standard as recommended by Engine Manufacturer complete all as specified and directed. Make :Castrol/Hindustan Petroleum/Indian oil
145Dismantling the alternator of 100KVA DG Set from its position from the foundation after disconnectionof electric connection with the help of chain pully, removing the bearing with the help of bearing pullar and shifting the alternator to authorised workshop for repair andservicingcomplete checking of connections , terminals, lugstightning of connectionsreplacement of bushes completeand refixing again after in original position andproper alingment complete all as specified and directed.
146Dismantling old unservicable Air cleaner elements and supply and fixing new Air cleaner elements inner and outer including dust cap suitable for100 KVA DG Set complete all as specified and as directed .
147Disconnecting and dismounting the self starter 12 Volts of 100 KVA DG Set from the engine transporting it to workshop for further dismantling for repair reassembling after repair/replacement of unservicable parts, transporting back the self from workshop to E/M installation fixing with the DG set, testing complete all as specified and as directed .
148Supply and fixing in repairs Heavy duty Acid lead battery 12 volt, capacity of 180 Ah for DG set 100 KVA complete all as specified and directed. Make: Battery Model No FXP0-XP1800 of EXIDE or Equivalent in Luminous/Amron.
149Disconnecting existing PVC water tank not exceeding 250 Ltrs capacity and Cleaning water tank with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etcthrough drain pipe or by manually all as specified and directed by Engineer-in-Charge (Tank shall be cleanedquarterly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and reconnecting and refixing in the same position after cleaning and testing for leakages of service tankscomplete all as specified and directed.
150All as per item No. 133 above but exceeding 250 but not exceeding 500 Ltrs capacity
151All as per item No. 133 above but exceeding 500 but not exceeding 1000 Ltrs capacity
152Taking down existing unserviceable water tank after disconnectiong water supply line and supply and fix new Rotational moulded polyethylene water storage tanks having capacity 500 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
153All as per item No. 151 above but 1000 Ltrs capacity.
154Supply and fix in repairs Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25 mm bore complete all as specified and directed.
155All as per item No. 153 above but 40 mm bore
156All as per item No. 153 above but 50 mm bore
157Supply and fix in repairs DOL Starter having capacity upto 7.5 HP 415 volt, 3 phase relay max range 9-15 Amps complete all as specified and directed.
158Supply and fix in repairs Star delta starter including all accessories suitable for 10 HP Pump set 415 volt, 3 phase relay max range 9-15 Amps complete all as specified and directed.
159Supplying and laying 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed complete to walls or in floors etc. after taking out unserviceable pipe complete all as specified and directed.
160Supplying and laying 40mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings fixed complete to walls or trenches, in floors etc. after taking out unserviceable pipe complete all as specified and directed.
161Repair to cast iron sluice valve size of 80 mm bore with flange and any pattern, repacking, stiffing box of sluice valve, spindle including taking out, regrinding/ rethreading, carrying out repair to make the sluice valve serviceable and refixingcomplete all as specified and directed .
162Repair to cast iron sluice valve size of 100 mm bore with flange and any pattern, repacking, stiffing box of sluice valve, spindle including taking out, regrinding/ rethreading, carrying out repair to make the sluice valve serviceable and refixingcomplete all as specified and directed .
163Repair to cast iron sluice valve size of 150 mm bore with flange and any pattern, repacking, stiffing box of sluice valve, spindle including taking out, regrinding/ rethreading, carrying out repair to make the sluice valve serviceable and refixingcomplete all as specified and directed .
164Material and labour for Cleaning of semi underground reservoir by closing of all valves in distribution and dewatering of complete tank and cleaning with wire brush, cloth, bleaching powder, removing dirt, scale from the tank and from mouths of circulating pipes etcthrough drain pipe or by manually, and washing of inner surface using lime and bleaching powder and removing the same until clean surface is obtained, all as specified and directed by Engineer-in-Charge (Tank shall be cleanedyearly and writing with white paint over black base on the tank as "TANK CLEANED ON" with date with 5 cm high letters/ numbers and connecting all connections after cleaning and testing for leakages of tank of capacity 100000 Ltrs complete all as directed. Note: Tank shall be cleanedyearly as directed by Engineer-in-Charge.
165All as per item No. 163 above but UG sump capcity of 25,000 litres.
166Disconnecting submersible motor of capacity 7.5HP 3 phase from electric system and lifting the pump and motor alongwith column pipe supporting wire, rope etc completely and lowering the whole system and connecting the electrical cable to starter after rectification of defects incl testing all as directed. NOTE: (i) The rate quoted shall be only for removal and refixing of submercible motor with accessories. (ii) Repair work of submercible pump shall be measured and paid separately under item No.169 here-in-after.
167Repair works to submersible motorpump set having capacity 7.5HP 3 phase 415 volts, shifting to the civil workshop for removing ofburnt windings, bearing etc, including cleaning the slots, rewinding with newstove enamelled copper wire as per existing size, including changing of bearings, etc , and installation, testing complete as per manufacturer"s instruction with entire satisfaction of Engr-in-charge. Note- Rate quoted shall be inclusive of cost of spares as required for repair work.
168Disconnecting existing water/electric connections, dismantling unservicable electric Motor pump set having capacity 10 HP 3 Phase, opening carefully, taking out old burnt windings, cleaning of solts of motor starter and rotor complete, rewinding the same with super enamelled winding wire of existing gauge/sizeas per exisitngpattern with proper insulating material apply two coats of varnish and heating of windings reassemble the motor with proper sealing, including necessary lathe work to made the pump high efficiency, etc.refixing in the same location, and connection to existing pipe line, testing and commissioning of motor pump set on full load complete to the entire satifcation of the Engineer-in-Charge.
169All as Per ser Item No 167 above but motor having capacity 90 HP
170Supply only geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and complete all as specified and as directed .
171Supply only PVC connections 15mm size for Hot and cold water connection with rubber washer & brass nuts, ISI marked of length 450mm complete all as specified and directed.
172Supply onlySafety plug "brass" ISI marked suitable for 25/50 ltrs geyers complete all as specified and directed.
173Taking down carefully geyser of any make and capacity 25/50ltrs, dismantlingthe geyser for inspection, cleaning of tank, repalcement of defectivepart such as heating element, thermostat switch, spacer ring, safety plug, glass wool, neon lamp, head assembly, rubber gasket, top and bottom cover, inspection plate, copper cable 3 core, 3 pin Top plug, element holding clamp, welding of studs for head assembly, defective inner and outer shell reassembling the geysers with one coat of milky white synthetic enamel spray paint of approved quality after cleaning of all dust rust etc and writingof MES No on the geyser using black paint, Reinstallation of geysers to its original postion complete all as specified. Note :Spare parts such as heating element thermostat switch, spacer ring, heon lamp, head assembly, glass wool, safety plug rubber, gasket, copper cable, top & bottom cover, inspection plate, CP & PVC connection, Plug Top, Outer & Inner shell element holding clamps etcshall be measured & paid for seperately in respective itemshere in after.
174Supply only heating element any type (i.e; Cup,thread or triangular) 1.5 KW,220/230 volts ISI marked.
175Supply only heating element any type (i.e; Cup,thread or triangular) 2.0 KW,220/230 volts ISI marked.
176Supply only bottom cover plate in two halves with self toppiry suitable and as per sample complete all as specified and directed. Make :Bajaj, Peeco, Recold/DITZ
177Supply only phase indicator red colour circular/rectangular shape as suitable and as per sample complete all as specified anddirected.
178Supply only PVC connections wire woven with nickel plated brass adopter, both side threaded 45cm long of suitable size of geyser 450mm complete all as specified and directed.
179Supply and fix in repairs DOL Starter having capacity upto 0.5 to 1.50 HP 230 volt, Single phase relay max range 9-14 Amps complete all as specified and directed.
180Supply and fix in repairs DOL Starter having capacity upto 2 to 3 HP 415 volt, 3 phase relay max range 9-14 Amps complete all as specified and directed.
181Supply and fix in repairs DOL Starter having capacity upto 5 to 7.5 HP 415 volt, 3 phase relay max range 9-14 Amps complete all as specified and directed.
182Supply and fix in repairs Star delta starter including all accessoriessuitable for 20 HP Pump set 415 volt, 3 phase relay max range 14-23 Amps complete all as specified and directed.
183Cleaning the vegetation including grass, bushes, small trees & all vegetation growth complete incl digging out roots of bushes around installation/Sump/OH tanks/ valve chamber including leveling the surface by removing debris to a distance n.exc 50 mtr all as directed.
184Schedule of Credit (Minus) Rs. 97,507.00 NOTE: Bidder shall insert credit amount of Rs. 97,507.00 as ratein Green field under Col-13.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail