Ups To Yadadri ( 5X800 Mw ) Ups To Yadadri ( 5X800 Mw ) , 2 X 180 Kva Ups, 240V Ac 1 Ph Output ( Unit-1, 2, 3, 4, 5, Common For Stage-I, Common For Stage-Ii ) , 2 X 10 Kva Ups, 240V Ac 1 Ph Output ( Foph & Fous, Rwph Stg-I & Ii Each, Chp Mcc-3 Stg-I & Ii Each, Chp Mcc-4 Stg-I & Ii Each, Ahp Mcc-2 Stg-I & Ii Each ) , 2 X 20 Kva Ups, 240V Ac 1 Ph Output ( Fwph Stg-I, Aua Stg- I & Ii Each ) , 2 X 30 Kva Ups, 240V Ac 1 Ph Output ( Chp Mcc-1, 2 Stg-I & Ii Each, Ahp Mcc-1 Stg-I & Ii Each ) , 1 X 130 Kva Ups, 240V Ac 1 Ph Output ( Fgd Stage-Ii ) , 1 X 100 Kva Ups, 240V Ac 1 Ph Output ( Fgd Stage-I ) , Cables From Battery To Ups, Ups Output To Acdb-1 & Ii, Size 2 , Cables From Battery To Ups, Ups Output To Acdb-1 & Ii, Size 1 , Cables From Battery To Ups, Ups Output To Acdb-1 & Ii, Size 4 , Cables From Battery To Ups, Ups Output To Acdb-1 & Ii, Size 00 , Cables From Battery To Ups, Ups Output To Acdb-1 & Ii, Size 000 , Cables From Battery To Ups, Ups Output To Acdb-1 & Ii, Size 0000 , Acdb-I & Acdb-Ii ( 176 Feeders Each ) ( Unit-1, 2, 3, 4, 5 ) , Acdb-I & Acdb-Ii ( 110 Feeders Each ) ( Common For U-1, 2 ) , Acdb-I & Acdb-Ii ( 103 Feeders Each ) ( Common For U-3, 4, 5 ) , Acdb-I & Acdb-Ii ( 65 Feeders Each ) ( Fgd Stg-I ) , Acdb-I & Acdb-Ii ( 78 Feeders Each ) ( Fgd Stg-Ii ) , Acdb-I & Acdb-Ii ( 7 Feeders Each ) ( Foph & Fous ) , Acdb-I & Acdb-Ii ( 9 Feeders Each ) ( Rwph Stg-I ) , Acdb-I & Acdb-Ii ( 6 Feeders Each ) ( Rwph Stg-Ii ) , Acdb-I & Acdb-Ii ( 15 Feeders Each ) ( Fwph Stg-I, Ahp Mcc-1, 2 Stg-I & Ii Each ) , Acdb-I & Acdb-Ii ( 30 Feeders Each ) ( Chp Mcc-1, 2 Stage-I & Ii Each ) , Acdb-I & Acdb-Ii ( 20 Feeders Each ) ( Chp Mcc-3 Stage-I & Ii Each, Aua Stg-I & Ii Each ) , Acdb-I & Acdb-Ii ( 10 Feeders Each ) ( Chp Mcc-4 Stg-I&Ii Each ) , Acdb-I & Acdb-Ii ( 35 Feeders Each ) ( Ahp Mcc-1 Stg-I & Ii Each ) , Bhms ( For 180 Cells ) , Bhms ( For 110 Cells ) , Discharge Resistor Bank For 2X180 Kva Ups , Discharge Resistor Bank For 2X30 Kva Ups , Mandatory Spares For Stg-I , Mandatory Spares For Stg-Ii , Erection Supervision And Commissioning Charges Of 2 X 180 Kva Ups ( Unit-1, 2, 3, 4, 5, Common For Stage-I, Common For Stage-Ii ) , Erection Supervision And Commissioning Charges Of 2 X 10 Kva Ups ( Foph & Fous, Rwph Stg-I & Ii Each, Chp Mcc-3 Stg-I & Ii Each, Chp Mcc-4 Stg-I & Ii Each, Ahp Mcc-2 Stg-I & Ii Each ) , Erection Supervision And Commissioning Charges Of 2 X 20 Kva Ups ( Fwph Stg-I, Aua Stg- I & Ii Each ) , Erection Supervision And Commissioning Charges Of 2 X 30 Kva Ups ( Chp Mcc-1, 2 Stg-I & Ii Each, Ahp Mcc-1 Stg-I & Ii Each ) , Erection Supervision And Commissioning Charges Of 1 X 130 Kva Ups ( Fgd Stage-Ii ) , Erection Supervision And Commissioning Charges Of 1 X 100 Kva Ups ( Fgd Stage-I ) , Freight Charge For Inr Portion Of Stage I , Freight Charge For Inr Portion Of Stage Ii , Freight Charge For Inr Portion Of Spares , Type Test Charges, If Applicable