Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #29495983

Providing Functional House Hold Tap Connection ( Phase-I ) Including Supply Of 15 Mm Dia Pvc Pipe Of Average Length Of 15 Mtr, Saddle Piece ( As Required Size ) , 15 Mm Dia Bib Cock Etc All Complete Including Newly Added Pipeline ( Parallel Or Exten

Issued by Government Departments · LAKSHMIPUR, West Bengal
Tender Value
82.46 Lakhs
Estimated cost
Bid Submission
25 Oct 2021
0 days left
EMD
1.65 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
LAKSHMIPUR → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing Functional House Hold Tap Connection ( Phase-I ) Including Supply Of 15 Mm Dia Pvc Pipe Of Average Length Of 15 Mtr, Saddle Piece ( As Required Size ) , 15 Mm Dia Bib Cock Etc All Complete Including Newly Added Pipeline ( Parallel Or Extension Or Damaged Line Repair ) At Lakshmipur W / S Scheme In Nadia District Under Nadia Arsenic Civil Division-Ii, P.H.E. Dte.

BOQ

Name of Work:Providing Functional House Hold Tap Connection (Phase-I) including supply of 15 mm dia PVC pipe of average length of 15 mtr, Saddle piece (As required size), 15 mm dia Bib cock etc all complete including newly added pipeline (parallel or extension or damaged line repair) at Lakshmipur W/s Scheme in Nadia District under Nadia Arsenic Civil Division-II, P.H.E. Dte.
Sl. No. Item Description
1Providing FHTC from the existing CI/DI/uPVC/HDPE/GI/AC distribution pipeline by installing 10 mm NB Gun-metal Ferrule conforming to IS 2692:1989 with latest amendments on the said pipeline with supply, fitting & fixing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc and supply & laying of 15mm NB PVC (schedule 80)/20mm OD HDPE (PE100, PN16) pipe (average 15m length) with all necessary specials 1.0 metre below the ground connecting the ferrule including cutting trenches in all sorts of soil and filling up trenches as per direction of the Engineer-in-charge and upto a point just inside the premises of the household or as directed by EIC. Supply and installation of a 15mm dia. alloy iron Bib Cock (tested to 21 Kg/cm2) above 1.0 Mtr. from ground, an alloy Stop Cock of 15 mm dia. with brass spindle (tested to 21 Kg/cm2) to be fitted in a position as directed by E.I.C. G.l pipe of TATA make (medium duly) of 2 metre length with all necessary specials to continue from the end of the HDPE/PVC pipe and upto 1.0 m above ground within the premises of household. Note : 1.PVC pipe shall of Schedule 80 (medium duty) conforming to ASTMD -1785 and threaded to match with Gl Pipes as per IS : 1239 (Part -1). 2.Rate is exclusive of supply and delivery of 10mm NB gun-metal Ferrule. 3.Payment of supply & laying of 15mm NB PVC (schedule 80)/20mm OD HDPE (PE100, PN16) pipe with all necessary specials 1.0 metre below the ground will be made on actual measurement basis. The rate of this item is Rs. 117/- per metre.
2Page No-2 Item No-4 (Approved rate of SE/EC vide Memo No 1627/EC. Dt : 29/08/2018 w.e.f. 01/09/2018): \"Labour for boring (horizontal) through any kind of soil for road crossing LDS including hire charges & labour for supply of subtable dia crossing upto full width road with necessary tools, trackles, inclu. Necessary arrangement for boring & pushing reqd. inclu. fixing, jointing, pumping out accumulated water, lighting arrangement, sealing of two casing ends by B/W (1:4) etc. as per direction of EIC. (B/W to be given seperately) (calculated Base rate).80 mm dia
3125 mm dia
4200 mm dia
5250 mm dia
6300 mm dia
7Making Village Road (average 3m width) crossing by horizontal auger boring for accomodation of laying of average 3 (three) nos. 15mm dia Gl pipes for FHTC or as per direction of Engineer-in-Charge.
8Collection of House Hold Details at Prescribed Format through Mobile App / Hard Copy including Geo-Reference as directed by EIC and Submission of the same to PHE Dte in soft copy.
9Supply & laying of 15mm NB PVC (schedule 80)/20mm OD HDPE (PE100, PN16) pipe with all necessary specials 1.0 metre below the ground will be made on actual measurement basis
10Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials, jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) PVC Pipes(Dia)i) 25 mm dia
11ii) 40mm dia
12Withdrawing of DI/CI pipes / AC pipe/UPVC Pipe after excavation of earth and with the help of chain pully derrick etc. by dismantling of jointing of rubber gasket joint or lead joint or flangejoint and stacking the withdrawn pipes and specials at site store /road flank godown etc. all complete as per direction of ElC.c) 250 mm dia to 350 mm dia Pipe
13Supplying, laying, fiting, fixing and jointing of UPVC pipes conforming to IS:4985-2000 with latest revision and amendments, if any, with necessary UPVC/CI specials, CIDF sluice valves, as per relevant I.S. specification including labour charges for earth work in excavation in any kind of soil including mixed soil with boulder ,road sub-grade and its flanks but excluding moorum and laterite or sand stonehard arock including cutting of brick payment without damaging the existing telephone/electrical cable line etc.(in case of damage of any type of cable line during excavation, necessary damaged charges as applicable by the respaective authority will be borne by the agency in his own cost. Loading, unloading, carrying of pipes, specials, valves from the local store to work site and lowering laying of pipes specials valves carefully in trenches maintaining proper levels and alignment ,jointing the pipe and specials including supplying of good quality/approved brand solvent cement (as per IS:14182-1994 including cost of all fabricated PVCfitting i.e. tees,bend, reducers, adopter etc.as per IS:101-1988 and making flange joints including supplying required quantity of nuts, bolts and rubber insertion (CIDF sluice valves will be supplied by the department free of cost) as required at site by adopting suitable method so as to facilate the maintenance of pipe line locally as per conventional method including back filling the trenches with good earth obtained from excavation of trenches including consolidation with watering in layer not exceeding 150mm thk. with maintaining an average depth of cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C
14N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line.ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list.iii)No part payment at any stage on account of supply of materials shall be entertained.iv)Payment will be made on actual consumption of materials.v)UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list.vi)Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so.vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate ofentire item.viii)All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill(A) Pressure Rating : Class - III(i) Laying of pipe line including cost of pipe only excluding cost ofspecials/fittings & valvesi) 50 mm OD UPVC line
15ii) 63 mm OD UPVC line
1675 mm OD UPVC line
1790 mm OD UPVC line
18200 mm OD UPVC line
19Construction of different dia Sluice valve /Air valve /Washout chamber in different sizes for village road where light traffic run and for main road where heavy traffic run as deptt.approved drawing with 25cm thick brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over150mm.thick sand filling in foundation including earth work in excavation and disposal of excess earth from work site with RCC (1:1.5:3) cover slab 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour & materials as per Departmental Dwg. [Reinforcement type:- Other manufactuerers not specified]i) 80 mm to 150 mm dia pipe
20i) 200 mm dia pipe
21Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 mIn ground floor including roof (a) upto 150 mm. thick
22(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
23Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
24Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety
25Providing 10 mm NB Gun-metal Ferrule conforming to IS 2692:1989 on the existing CI/DI/uPVC/HDPE/GI/AC distribution pipeline with supply, fitting & fixing of all other accessories like saddle piece of required size to fit the existing distribution pipeline, specials, nut & bolts, rubber sheet, washers etc, including cutting trenches in all shorts of soil and filling up trenches as per direction of the Engineer-in charge.[ N.B: As per Circular Memo No-PHE/ EIC/ 370/2021 Dated:26th July, 2021 excluding cost of ferrule @ Rs-446/- of this item i.e- 922.00-446.00 =476.00/-]
26Drum Sheet Walling 1.40m (av.) high on Sal-bullah /Eucalyptus bullah piling 10 cm dia. and 3.25m longdriven 1.75m (av.) below G.L. and 75cm centre tocentre including fitting fixing 3 nos. of half bullah pieces (from 10 cm dia) and drum(empty bitumen)sheet (approved condition) of height 1.5m , cuttingand straightening drum sheet (each joint must havelap length of min.50mm) including cost of necessary nails, bolts, nuts etc. and providing 2 to 3m long halfbullah ties of 10cm dia. @ 2.25 m centre to centrefixed with 10 cm dia. bullah posts driven 1.5m belowG.L. including cost of all materials and one coat ofcoal tarring to all bullah etc. complete as per direction.(i) Using Eucalyptus bullah
27Supplying Eucalyptus-bullah piles at work site, including dressing and making one end pointed 100/0.78+1 = 129 Nos 96/6 = 16 Nos100/20 +1 = 6NosTotal = 129+16+6 =151 Nos X 6.0Mtr = 906.0 M (v) 100mm diameter
28Labour for driving Sal-bullah / Eucalyptus bullahpiles by monkey in sorts of soil including hoisting andplacing piles in position, protecting the pile headwith iron ring and cutting and shaping heads beforeand after driving and including hire and labour for necessary driving appliances and all tackles. 129 X1.75 + 6 X 1.5 =234.75 Mtr(v) 100mm diameter
29Labour for fitting and fixing 10 cm. to 13 cm. diameter Sal-bullah/Eucalyptus-bullah as ties andrunners including necessary nails, bolts and nuts. 16 X 6 X 2=192 .0 Mtr 4.0X2=8.0 Mtr 6.0Mtr X2 =12.0 MtrTotal=212.0 Mtr.
30Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) c.(ii) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth.
31Add GST @12% and Labour welfare cess 1% on total item no. 1 to 16 as per PWD Schedule

AI Tender Summary

OUR REF NO 29495983
AUTHORITY Government Departments
TENDER VALUE 82.46 Lakhs
LAST DATE 25-10-2021
Authority
Authority Name Public Health Engineering Department
Work Description Providing Functional House Hold Tap Connection ( Phase-I ) Including Supply Of 15 Mm Dia Pvc Pipe Of Average Length Of 15 Mtr, Saddle Piece ( As Required Size ) , 15 Mm Dia Bib Cock Etc All Complete Including Newly Added Pipeline ( Parallel Or Extension Or Damaged Line Repair ) At Lakshmipur W / S Scheme In Nadia District Under Nadia Arsenic Civil Division-Ii, P.H.E. Dte.
Basic Detail
Tender No WBPHED/05/EE/NACD-II OF 2021-22
Bidding Type Tender
Location
City LAKSHMIPUR
State West Bengal
Key Dates
Publish Date 08 Oct 2021
Submission Date 25 Oct 2021
Open Date 27 Oct 2021
Finance
Tender Value 82.46 Lakhs
Tender Fee Ref. Documents
EMD 1.65 Lakhs
Exemption Not Available
Document List
6dad700c-50c9-4738-9fbd-b81644e17075.html
BOQ_667187.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 08, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 25, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 27, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

6dad700c-50c9-4738-9fbd-b81644e17075.html

xls

BOQ_667187.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail