Name of Work: Implementation of 24 X 7 water supply – under Sujala at VSS Nagar in ward No.11 & 17 (Part), BMC, Bhubaneswar for the work Chlorination work (chlorine Dosing pump & Analyzer, etc.)
Sl. No.
Item Description
1
Provision for supply testing and commissioning of chemical feed pump 0 to 100 in propertion to 4 to 20 mA signal.100 SPM@75Hz and 67 SPM @50Hz Motor frequency range=15 to 75 Hz Auto/manual, Remote,while running or at rest,5:1 Turn down ratio,Over and above there will be provision for manual stroke variation. The disch piping and fitting starting from the pump flange upto the tank nozzle including VFD 3 phase input and 415 volt 3 phase output and will have a rating of 3 HP. Inverter will receive a signal of 4 to 20 mA signal with electricinstallation etc. all complete
2
Installation charges of chemical feed pump with storage tank & accessories including all piping arrangement and hire charges of Hydra etc all complete
3
Supplying of control panel with VFD for running of chlorine dosing pump and motor etc compatable with SCADA & PLC system etc all complete as per direction of Engineer-In-charge
4
Supply, of On line Chlorine Analyser with following technical specification
5
i,e.Single Channel free Chlorine Analyser,Transmitter-Aqua4trans DualChannel,FRC sensor FMNSX5 with 10 feet cable(with manual PH compensetion),Complete system pre mounted on plate with FTCs foe sensors,Power supply110-240VAC,Trans 2\" pipe/wall /Panel mount type,RangeFRC-0-5 ppm,Complete plate mounted system,(The Analyzer must be pre wired on plate,we will provide only power supply & pipe connection system)
6
Supply & Installation of PH analyser with following specifications:- Measurement-PH/ORP(Platinum), Temperature range-0-60 degree C (32 to 140 degree F),Maximum Pressure-6 Bar(90PSI), (ABB/E&H/Forbes Marshal)
7
Chages for installation, Testing & commissioning ofOn line Chlorine Analyser including laying of connecting uPVC pipe Sch-80 & power supply arrangements etc. complete as per requirement & direction of Engineer in Charge.