Internal Electrification In A Type Shops 16 No B 10 No C 25 No .Construction Of L.T. Line In Front Of A B And C Led Street Light, S / L Of Cable, Bus Bar Panel For Connection Of A, B, C Type Shops At Nmy Khair Aligarh
Tender Overview
Project Description
Internal Electrification In A Type Shops 16 No B 10 No C 25 No .Construction Of L.T. Line In Front Of A B And C Led Street Light, S / L Of Cable, Bus Bar Panel For Connection Of A, B, C Type Shops At Nmy Khair Aligarh
BOQ
| Sl. No. | Item Description |
| 1 | Wiring point for light with 1.5 sq.mm FRLSH P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit 2mm thick with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement beforeconcreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash..SI No 138( C) +187(A). |
| 2 | Wiring point for fan with 1.5 sq.mm FRLSH P.V.C. insulated multistrandsingle core Copper Conductor cable in PVC conduit 2mm thick with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & ceiling rose / angle / batten holder on 3 mm thick phenolic laminated backelite sheet etc complete in all respects as directed, including matching color wash. SI No 140( C) +187(A). |
| 3 | iWiring point for plug with 1.5 sq.mm FRLSH P.V.C. insulated multistrandsinglecore Copper Conductor cable in PVC conduit 2mm thick with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthing wire drawn inside the conduitpartly concealedin wall& partlylaidin slab along with the reinforcement before concreting,complete with modular typeswitch & socket etc, complete in all respect including matching colour wash.SI No 141( C) +187(C). |
| 4 | Supply and wiring of sub main withtwo number 6 sq. mm. FRLSH PVC insulated 1100 V grade multi strand single core copper conductor cable in 25 mm dia heavy duty 2 mm PVC conduitpartly concealedinwall andpartlylaid in slab alongwith reinforcement before concreting, with one number 4sq mm FRLSH PVC insulated multi strand copper conductor cable as earth continuity wire drawn in completein all respect. SI No 222(C) |
| 5 | Supply and burying of 40 mm dia. x 4.5 metres long G.I. pipe vertically for earthing having 12 mm dia. holes spaced 75 mm apart drilled up to 2 metres from the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in G.I. pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board ,30 cm square C.I. box with hinged cover masonary enclousure funnel at top ,alternate layers of charcoal/ coke and salt at least 150 mm thick alround etc. as per directions of engineer-in- charge complete in all respects as per drawing.SI No 701 |
| 6 | Supply and fixing of one number 8 to 6 SWG G.I. Wire in 15mm dia. G.I. Pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sandlabour. T and P other material required for proper completion of the work as directed at site. SI No 721 |
| 7 | Supply and fixing of 6 to 32Amp Amp MCB (10 KA)C Curve. CatA SI No 1002 |
| 8 | Supply and fixingof 6 Amp to 32 Amp DPMCB (10KA). CCurve. CatA SI No 1009 |
| 9 | Supply and fixing surface/flush mounting 4 ways SPN distribution board with additional metal door withoutMCB complete in all respects, as directed at site by engineer in charge. Cat A. SI No 1022(A) |
| 10 | Supply and fixing surface/flush mounting 8 ways SPN distribution board with additional metal door withoutMCB complete in all respects, as directed at site by engineer in charge. Cat A. SI No 1024(A) |
| 11 | Supply and fixing of power plug with 20A/240 V flush typemodular switchand 5 pin 20 A/250 V flush type universal modular socket, switch on concealed M.S. box including supply of all materials labour T&C etc. required for proper Completion of work. SI No 1139(A) |
| 12 | Supply and fixing of hexagonal/ round G.P. fan box of approved make made up of 1.0 mm thick ISI marked G.P. sheet spot welded four to eight holes 25.4 mm for pipe entry of tmm G.P. sheet made upper and lower cover duly screwed fitted with 300 mm round zink coated M.S. Bar x 12 mm and brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof beforeconcreting along with supply of all materials, labor, T & P etc. required forproper completion ofthe work .SI No 1149 |
| 13 | Supply and fixing of electronic fan regulator(Modular) 120-280 V ISI Marked on the existing switch board including making connection, required, materials, labour T/P for proper completion of work to the satisfaction of engineer in chargeof work. SI No 1203(C) |
| 14 | Supply and wiring of submain with two number 2.5 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in20mm dia heavy duty (2mm thick ) PVC conduitconcealed in wall along with reinforcement befor concreting with one number 1.5 Sqmm FRLSH PVC insulated 1100 volt grade Multistand single core copperconductor as earth continuity wire including matching colour wash etc. complete in all respects. SI No 1304(C) |
| 15 | Supply and erection of steel tabular pole 9.50 meter long designated 410 SP-36 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respects SI No 616 |
| 16 | Supply and fixing of 100 mm x 110 mm x 80 mm pin insulator including G.I. bolts spindle nuts etc. complete in all respects. SI No 621 |
| 17 | Supply and fixing of 230 mm x 32 mm x 1.5 mm galvanized steel straps including holes for shackle insulator pins and bolts etc. complete in all respects. SI No 622 |
| 18 | Supply and erection of ‘D’ clamps of 50 mm x 6 mm flat iron on steel tubular poles/steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint. SI No 623 |
| 19 | Supply and erection of overhead line with ACSR conductor on poles/service bracket including binding etc. complete in all respects. SI No 627 |
| 20 | Supply and erection of overhead line with GI wire no 8 to 4 SWGon poles/service bracket including binding etc. complete in all respects. SI No 628 |
| 21 | Supply and erection of hexagonal/cradle type guaredofGI wire no 8 to 4 SWG including binding etc. complete in all respects. SI No 629 |
| 22 | S/E of stay set at least 3.5 met res away from the pole complete with galvanized 19 mm dia.x 1.80 metre long stay rod, 30 cm x30 cm x6.3 mm anchor plat,thimble stay clamps,stay insulator ,19 mm x 600 mm double screw tightner 1/3.15 mm G.I. stay wire etc. in 1:3:6 cement concrete in all respects. SI No 631 |
| 23 | Painting of the electric pole with 2 coats of aluminiuin paint over red oxide primer Etc. SI No 634 |
| 24 | Supply and burying of 600 mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20 mm dia G.I. pipe and funnel for watering and one earthing lead of one no.8 to 10 SWG GI wire in 15 mm dia G.I. pipe up to switch board (from appron to switch board the cost of GI pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonary housing alternate layers of charcoal /coke and salt at least 150 mm thick alround etc. as per directions of engineer-in-charge complete in all respects as per drawing. SI No 702 |
| 25 | Supply and fixing of LED Street light Fitting with mandatory driver set having dia cast aluminium body and lenses suitable for 110 to 130 watt confirming to IP66 Protection having company LOGO engraved complete in all respect including labour.12100-14300 System lumens high power LED with lenses.>110 lm / w,PF > 0.95, THD < 10% at full load, CRI>70, potted driver set ( not circuitory), phase to phase protection at 440V &>300V auto cut and restart feature, with five years warrantee. CAT-AAA. SI No 1424 |
| 26 | Supply and fixing and concealing of 50 mm dia. 2 mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction ofEngineer in charge. SI No 152(A) |
| 27 | Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 70 sq. mm 3-1/2 core SI No 501(M) |
| 28 | Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 95 sq. mm 3-1/2 core SI No 501(N) |
| 29 | Supply and fixing of brass nickle plated compression gland for PVC insulated &armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouringofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge. 70 sq. mm 3-1/2 core. SI No 503(M) |
| 30 | Supply and fixing of brass nickle plated compression gland for PVC insulated &armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouringofthe cable shall be properly connected with the earth as per direction of Engineer-Incharge. 70 sq. mm 3-1/2 core. SI No 503(N) |
| 31 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 70 sq. mm SI No 504(H) |
| 32 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 95 sq. mm SI No 504(i) |
| 33 | Supply and Fixing of Tape off box 32 Amp to 100 Amp TPN for Sandwich alumininum bus bar trunkingcompletein all respect. TPN – 32 to 100 A – 1 NoDP MCB 6-32 A – 8 No CAT A SI No 929/1009 |
| 34 | Supply and Fixing of Tape off box250 Amp to 400 Amp TPN for Sandwich alumininum bus bar trunking completein all respect. SI No 931 |
| 35 | Providing, laying and fixing of 100 mm dia GI Pipe (medium class) in ground complete with GI fitting including trenching(75 cm deep) and refilling etc as required.DSR 14.13.3 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender