Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Area Of Delhi Cantt , Upkeep Of Offices And Installations Under Ge ( U ) Pm, Delhi Cantt -10 And Repair / Maintenance To Lt Panels And Lt Cables And Other, DELHI CANTT-Delhi

Military Engineer Services-MES has published Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Area Of Delhi Cantt , Upkeep Of Offices And Installations Under Ge ( U ) Pm, Delhi Cantt -10 And Repair / Maintenance To Lt Panels And Lt Cables And Other. Submission Date for this Tender is 01-11-2021. LT Cable Tenders in DELHI CANTT Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

29437699
Corrigendum : Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Area Of Delhi Cantt , Upkeep Of Offices And Installations Under Ge ( U ) Pm, Delhi Cantt -10 And Repair / Maintenance To Lt Panels And Lt Cables And Other
Open Tender
Indian
Delhi
DELHI CANTT
01-11-2021

Tender Details

Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Area Of Delhi Cantt , Upkeep Of Offices And Installations Under Ge ( U ) Pm, Delhi Cantt -10 And Repair / Maintenance To Lt Panels And Lt Cables And Other Mi Repair And Maintenance Of Summer Appliances Including Desert Cooler And Water Cooler At Dcn Palam Area Of Delhi Cantt , Upkeep Of Offices And Installations Under Ge ( U ) Pm, Delhi Cantt -10 And Repair / Maintenance To Lt Panels And Lt Cables And Other Mi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Oct-2021 Corrigendum No 1 BOQ 25-10-2021
2 25-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 84260.0 /-
Tender Value
INR 42.13 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF SUMMER APPLIANCES INCLUDING DESERT COOLER AND WATER COOLER AT DCN PALAM AREA OF DELHI CANTT , UPKEEP OF OFFICES AND INSTALLATIONS UNDER GE(U) P&M, DELHI CANTT -10 AND REPAIR/MAINTENANCE TO LT PANELS AND LT CABLES AND OTHER MISC WORKS OF CENTRAL AC PLANTS UNDER GE (U) P&M DELHI CANTT-10
Sl. No. Item Description
1Section -I
2Taking downfor servicingof split type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed by Engineer-in-Charge.
3Taking downfor servicingofWindow type AC 1.5/2 TR Capacityincluding cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner OR cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit including PCB, fan, blower, etc, changing connections from heating mode to cooling mode or vice-versa andkeepingthe AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing positioncomplete all specified and as directed by Engineer-in-Charge. Notes for Ser Item No 1 & 2 :- (i) Replacement of defectivespares for making the AC units in satisfactory working conditionwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & refixing of new sparesshall deemed to be included in unit quoted rate. (ii) Penaltywill be charged for not attending complaint from 12 Hoursto 24 hours Rs. 500/- each complaint. Furtherif complaint not attended and rectifiedwithin 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioningtime of complaint,for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency and double of the job order amount to be deducted from contractors dues.
4Supply only 15mm dia PVC pipe medium grade including fittings. (Make:- Prayag/ Supreme/ Prince.)
5Supply only printed circuit board (PCB) compatible with electric accessories and sensors for split type AC/ window type AC of capacity of 1.5/ 2 TR.
6Supply only starting capacitors 80-100 MFD.(Make:- Epcos/ Usha/ Keltron.)
7Supply only starting capacitors 100-120 MFD.(Make : – Usha/ Keltron/Epcos)
8Supply only running capacitor 50+6 MFD. (Make:- Epcos/ Usha/ Keltron.)
9Supply only running capacitor 45+5 MFD. (Make:- Epcos/ Usha/ Keltron.)
10Supply and fixing in repairs of condenser mortor 1/3 HP suitable for window type AC double shaft. (Make:- AUE/ Crompton Greaves/Cool Master.)
11Supply only starting relay SR-1622. (Make:- Hytech/ Renutrol/ Sri Ram/Microtech.)
12Supply only running capacitor 36 MFD. (Make:- Epcos/ Usha/ Keltron.)
13Supply only thermostat switch 2059/ 2064/ 2054. ( Make :- Indfoss/ Renutrol).
14Supply only copper filter double capilary pencil type.
15Supply only regulator knob suitable for 1.5TR /2 TR capacity AC.
16Supply only PVC insulated multi-stranded 3 core flexible cable of size 2.5sqmm. (Make:- Finolex/ Havells/ Polycab/ KEI Industries.) Note for item No 4 to 9 and 11 to 15:- Materials of item No 4 to 9 and 11 to 15 to be incorporated in item No 2 & 3 here-in-before.
17Disconnecting from mains and taking out existing unserviceable sealed compressor unit from the window type Air Conditioner of Cap2 Ton,of any make any type from any locationandSupply , Installingand testing of new sealed unit compressorandone yearwarranty certificate from manufacturer/ dealer includingcleaning and removing dust/dirt from the cooling coil condenser coilwith necessary modification capillary tube etc&Charging of Gas R-22/R-410A/R-32 and commissioning complete all as specified & directed by Engg-in-Charge.,( Make:- Emerson /Tecumseh/LG) Note :- Transportation Charges from siteto trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above.
18-ditto- all as per item No. 17 abovebut window type Air Conditioner ofCapacity1.5 TR.
19-ditto- all as per item No. 17 abovebut spilt type Air Conditioner ofCapacity 2 TR.
20-ditto- all as per item No. 17 above but spilt type Air Conditioner Capacity 1.5 TR.
21Supply & fixing in repairs 1.5 TR capacity window type AC kit including condenser coil, cooling coil, front grill blower motor, chasis, base plate complete set except compressor. (Make:- (Nepoleon/ Commander/ Speed.)
22-ditto- all as per item No. 21 abovebut window type Air Conditioner ofCapacity 2.0 TR. (Make:- Nepoleon/ Commander/ Speed.)
23Taking down unserviceable indoor unitof split AC of any make andsupply & fixing new indoor unit complete set suitable for 1.5 TRcapacity complete all as directed by Engr-in-Charge.(Make:- Nepoleon/ Commander/Camipro.)
24All as per item No. 22 above but spilt type Air Conditioner of capacity2 TR. (Make:- Nepoleon/ Commander/Camipro.)
25Supply and fixing in repairs of1.5TR capacity split type Air Conditioner outdoor kit including condenser coil, blower motor, chasis, base plate complete set except compressor. (Make:- Nepoleon/ Commander/Camipro.)
26-ditto- all as per item No. 24 above but spilt type Air Conditioner of capacity2 TR.(Make:- Nepoleon/ Commander/Camipro.)
27Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), multistranded,unsheathed1100 volts grade in PVC casing caping(heavy grade) of adequit size with all fittings and casing capingaccessories of surface type including one run 6 Sqmm single core unsheathed multistranded copper conductor cable FRLS (conforming to IS-694)as earth wire including taking down old unservisible sub main wiring complete all as specified and as directed. (Make of cable:- RR Kabel/Finolex/ Havells/ Polycab/ KEI Industries.) {Note :-(i) Two runs of cable with one runs earth wire and PVC casing capping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing capping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.}
28Supply & fixing in repairs industrial type plug with two pin and earth confirming to IS/IES-309 of capacity 20 Amps complete all as specified and as directed (Make : Schneider/ Legrand/ ABB/ Seimens/L&T)
29Supply and fixing in repairs metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 32 Amps iincluding taking down old unservisible metal clad socket complete all as specified and as directed. (Make : Schneider/ Legrand/ ABB/ Seimens/L&T)
30Supply and fixing in repairs MCB SP 240 volts 6 to 32 Amps, 10 kA, "C" curve complete all as specified and as directed. (Make : Schneider/ Legrand/ ABB/ Seimens/L&T)
31Material and labour for detecting of leakages of gases in window type /Split Type AC unit of capacity 1.5/2 TR at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
32Supply and fillingrefrigerant gas R-22/R-410A/R-32/R-134A in window type /Split Type AC unit of capacity 1.5/2 TR, Deep Freezer, Refrigerator, Water Cooler of any capacity complete all as specified and as directed. (Make : Mefron/Floron/ Refron.)
33Supply and fixing in repairs of front grill of window type AC of capacity 1.5 TRcomplete all as specified and directed.
34Supply and fixing in repairs of front grill of window type AC of capacity 2.0 TRcomplete all as specified and directed.
35Taking down unserviceable reversible valve for split/ window type AC of capacity 1.5TR and supply & fixing new reversible valve with solenoid coil including required copper pipe complete all as specified and directed by Engr-in-charge:-. (Note:- Supply & filling of refrigerant gasshall be measured and paid under relevent item.)
36-ditto- all as per item No. 35 above but spilt/window type Air Conditioner of capacity2 TR.
37Supply & fixing in repairs heavy duty copper pipe 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts,bolts and screws of required size complete all as specified and directed by Engr-in-Charge. (Make- Malasia/ CAMIPRO/ DIAMOND/ STAR)
38-ditto- all as per item No. 37 above but copper pipe 12mm (1/2") dia/ bore. (Make- Malasia/ CAMIPRO/ DIAMOND/ STAR)
39-ditto- all as per item No. 37 above but copper pipe 15mm (5/8") dia/ bore. (Make- Malasia/ CAMIPRO/ DIAMOND/ STAR)
40Supply and fixing of out door stand for split type AC desert cooler of any capacity made up of angle iron frame of any size grouting on wall or floor as directed and apllying of two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer including taking down old unserviceable one complete all as specified and directed.
41Supply & fixing in repair Indoor Air blower motor for Split type AC 1.5 TR & 2 TR capacity complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
42Supply & fixing in repair Window AC air blower motor for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. (Make-AUE/Crompton Greaves/Cool Master.)
43Supply & fixing in repairs Window AC condenser fan blade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed. (Make- TIPCON/ USHA/ EPCOS/ KELTRON)
44Supply & fixing in repairsSplit AC Condenser fanblade plastic body for 1.5 TR & 2 TR capacity AC complete all as specified & as directed.(Make- TIPCON/ USHA/ EPCOS/ KELTRON)
45Supply & fixing in repairs running capacitor of 2.5 MFD capacitycomplete all as directed. (Make- USHA/EPCOS/KELTRON)
46Supply & fixing in repairs running capacitor of 4 MFD capacitycomplete all as directed. (Make- USHA/EPCOS/KELTRON)
47Supply & fixing in repairsrunning capacitor of 6 MFDcapacitycomplete all asdirected. (Make- USHA/EPCOS/KELTRON)
48Supply only remote control including battery for split AC Cap 1.5/2 TR of make as per site requirement and replace of old one complete all as directed by Engr-in-Charge. (Make-LG/Blue Star/Voltas)
49Supply & fixing in repairs plastic louvers for (Front panel)for Window type AC of capacity 1.5/2 TR complete all as directed by Engr-in-Charge.
50Supply & fixing in repairs of selector switch for fan/cooling of Window AC 1.5/2 Ton complete all as specified & as directed.
51Supply & fixing in repairs of suctionand discharge valve set of size 15mm (5/8""), 6mm (1/4"") and 12mm (1/2"")for Split AC 1.5/2 TR capacity complete all as directed by Engr-in-Charge. {Note:-(i) 15mm (5/8"") or 6mm (1/4"") and 12mm (1/2"") made one set (ii) Supply & filling of refrigerant gasshall be measured and paid under relevent item.}
52M&L for 4 mm thick plywood of grade BWR, type BB including necessary fixing accessories and taking down old one and applying two coat of synthetic enamel paint(1st grade quality) over a coat of pink primer complete all as specified & as directed. (Make:- Century/ Dura/ Green ply/ Kitply.)
53Disconnecting the mains and taking out the unserviceable condenser coilof window type AC of capacity 1.5/ 2TR of any make from any location and supply, fixing and testing new condenser coil as per existing size & patterns for complete all as specified & as directed. (Make:-Suitable for Voltas/Carrier/LG/ Hitachi/ Blue Star)
54-ditto- all as per item No. 53 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
55Dismantling the evaporator/cooling coil of window type Air Conditioner of capacity 1.5/ 2TR, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing the same complete all as specified & as directed by Engr-in-Charge.
56-ditto- all as per item No. 55 above but spilt type Air Conditioner Capacity 1.5/ 2 TR.
57Taking down unserviceable insulation for copper pipe of any dia, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 to 2.0 TR complete all as specified and directed by Engineer-in-charge.
58Taking down unserviceable contactor for split type AC of capacity 1.5 TR/ 2.0TR, supply and fixing new contactor single phase suitable for split type ACcomplete allas specified and directed by Engineer-in-charge.
59Disconnection and removing of serviceable window type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer from its position and fixing the same in other location including all other fixing accessories and testing complete allas specified and directed by Engineer-in-charge.
60Disconnection and removing of serviceable split type AC of capacity 1.5 TR/ 2.0TR of any make and model along with stabilizer (Indoor & Outdoor Unit) from its position and fixing the same in other location including all other fixing accessories and testing complete allas specified and directed by Engineer-in-charge.
61Disconnecting the unserviceable PCB compatible from existing Window/ Split type AC of capacity 1.5/ 2TR and refixing after necessary repair for satisfactory functioning of the AC unit complete allas specified and directed by Engineer-in-charge.
62Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make ofwindow type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and directed by Engineer-in-charge.
63Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make of indoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and directed by Engineer-in-charge.
64Dismantling and removing defective burnt blower unit motor ofcapacity 1.5/ 2.0 TR of any make of outdoor units of split type AC and rewinding the motor with enamel copper winding wire of existing guage and size including replacement of worn out motor bearing etc, refixing and testing complete allas specified and directed by Engineer-in-charge.
65Supply & fixing in repairs of blower fan blade of indoor unit for Split 1.5 TR & 2 TR capacity complete all as specified & as directed.
66Supply & fixing in repairs of metal clad socket of 20 Amps complete all as specified & as directed.(Make:- L & T/ Legrand/ C & S/ ABB/Seimens)
67Collecting of unserviceablevoltage stabilizerof capacity 2 to 5 KVA from the MES store yard of AGE AC(OTBH) or dismantlingthe same from site and transporting to contractors workshopfor locating the fault includingcheckingthe serviceability of electrical/electronic circuits relays andreplacement of defective spare parts , reassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to MES store yard complete all as specified and directed by Engr-in-charge Note :- 1. Replacement of defectivespares and rewinding of transformer of voltage stabilizerwill be measured & paidseparately under relevant items and Labour charges for taking out old spares & fixing of new sparesshall deemed to be included in unit rate quoted.
68Supply onlyfollowing new spare partsof Voltage stabilizerofcapacity 2 to 5 KVA :-
69Voltmeter (Analog) 0 to 300 volts any type shape single phase 50 Hz AC supply (Make:- AE/ MECO/ Rishabh)
70Digitaltype Voltmeter0 to 300 volts any type shape single phase 50 Hz AC supply, (Make:- AE/ MECO/ Rishabh)
71Printer circuit control card suitable for 2 to 5 KVA.
72Input/output switch (Make:-AE/Rishabh/Meco)
73Push on switch (Make:-AE/Rishabh/Meco)
74Indicator with neon bulbs (Make:- AE/L & T/ C & S)
75Trigger Transformer for 2 to 5 KVA.
76Relay for 2 to 5 KVA voltage stabilizer (Make:-Renutrol /Technomac)
77Time relay and High/low voltage cut off circuit with relay suitable for 2 KVA to 5 KVA (Make Renutorl/Technomac) Note for item No 68.01 to 68.09 :- Materials of item No 68.01 to 68.09 to be incorporated in item No 67 here-in-before
78Taking out the burnt winding of transformer of voltage stabilizer and preparing core after cleaning by suitable cleaning agent and rewinding the transformer of voltage stabilizer with super enameld copper wire of existing gauge including varnishing, heating and refiting of capacity 2KVA voltage stabilizer, complete all as specifies & directed by Engr-in-Charge.
79-ditto- all as per item No 69 here-in-before but 4 KVA.
80-ditto- all as per item No 69 here-in-before but 5 KVA.
81Disconnecting from mains and taking downfor servicingofWater Cooler ofCapacity 40/80, 60/120,Ltrs including cleaning of cooling coil, air filters , condenser, compressors, fan motor etc with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs,fan andblower, etc., andkeepingthe Water coolerunit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and installation in same location complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defectivespares for making the water cooler units in satisfactory working condition will be measured & paidseparately under relevant items and Transportation & labour charges for taking down old spares and fixing of new sparesshall deemed to be included in unit rate quoted above.
82Supply onlyfollowing new spare parts of Water cooler unit ofcapacity 40/80 to 60/120 Ltrs:-
83Starting relaysuitable for 40/80 , 60/120 Ltr. (Make: Sri Ram/Renutrol/Micro Tech.)
84Starting Capacitor 25 MFD. (Make :- Usha/Epcos/Keltron)
85Running Capacitor 10 MFD . (Make:-Usha/Epcos/Keltron)
86PVC flexible drainHose pipe 40 mm.
87Condenser fan blade aluminium body for Motor 1/32HP, 1/35HP .(Make: Tipcon/ Usha/Epcos/Keltron)
88Over load protector device for 60/120 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
89Over load protector device for 40/80 ltrs capacity water cooler. (Make: Sri Ram/Renutrol/Micro Tech.)
90Thermostat switch. (Make: Indfoss/Renutrol/Godrej.)
91Self closing chromium plated push taps for water cooler Capacity 40/80,60/120 Ltr.(Make: Usha/Prayag/ Cera/ Essco) Note for item No 74.01 to 74.09 :- Materials of item No 74.01 to 74.09 to be incorporated in item No 72 here-in-before
92Disconnecting the electric and Water connections and taking out the existing unserviceable compressor of any make from water cooler storage type capacity60/120 Ltrs from any location andsupply installation & testing of new sealed unit compressorof similar capacity in same locationalongwith one year warranty certificate from manufacturer/ dealer and cleaning of condenser by machine doing vacum the fully system and supply and charging of oil gas and other necessary lubricants including reconnecting the electric and water connections, transportaion& testing complete all as directed by Engr-in-charge. (Make Tecumseh/Emerson/LG.)
93-ditto- all as per item No. 75 above butWater coolerofcapacity 40/80 Ltrs.
94Disconnecting the electric mains and taking out unserviceable condenser fan motor1/16 HP from water cooler cap.60/120 Ltr and supply and replace with new motor single phase AC 220 V of same capacity including reconnecting the electric connections and testing complete all as directed by Engr-in-Charge. (Make : AUE, Crompton Greaves / Cool Master)
95All as per item No. 77 above but 1/32 HP Water coolerofCapacity 40/80 Ltrs.
96Disconnecting the mains and taking out the unserviceable condenser coil and S & F new condenser coil as per existing size & patterns for Water/Coolers of capacity 60/120 Ltrs complete all as specified & as directed.
97Disconnecting the mains and taking out the unserviceable condenser coiland S & F new condenser coil as per existing size & patterns for Water/Coolers of capacity 40/80Ltrs complete all as specified & as directed.
98Dismantling the evaporator/cooling coil of water cooler capacity 60/120 & 40/80 Ltrs, checking the leakages of gas and rectify the leakages by brazing or as other manner and refixing in same position complete all as specified & as directed by Engr-in-Charge.
99Cleaning & removing the existing paint ofWater Coolers capacity60/120 & 40/80 Ltrs by rubbing & preparing the surface smooth & applying one coat of zinc chrome primer and two coats of synthetic enamel paint (1st grade quality) by spray gun machine of colour as approved by Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
100Taking up or down steel tubing and connection and removing off site15mm bore of pipecomplete all as specified and as directed.
101Supply and fixinggalvanised steel tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.)fixed on wall or floor complete all as specified and as directed.(Make:- JINDAL STEEL/ PRAKASH/ TATA/ OSWAL.)
102Supply and fixing in repairs stop valve 15mm bore dia, fancy type chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unionscomplete all as specified and as directed. (Make:-PARRYWARE/ PRAYAG/ CERA/ ESSCO.)
103Taking down unserviceable PVC connection pipe and Supply and Fixing of PVC connections pipe of 15 mm dia bore with PTMT nuts of length 900 mm complete all as specified & as directed. (Make:- Prayag/ Polytuff)
104Material and labour for detecting of leakages of gases in Water cooler, Refrigerator, deep freezer of any capacity at any location and rectifying the defect to stop the leakage by gas welding or by any other means including cutting and brazing of copper tubes testing and commissioning complete in satisfactory working condition.
105Disconnecting from mains and taking downfor servicingof Refrigerator/Deep freezerofCapacity 165/180/195/310/330/450 and 500 Ltrsincluding detecting the leakage of gas and refilling of refrigerant ,cleaning of cooling coil, condenser, compressors, with vacuum cleaner or cleaning solution includingcheckingthe serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, etc., andkeepingthe Refrigerator unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Replacement of defectivespares for making the Refrigerator/ Deep Freezer units in satisfactory working condition will be measured & paidseparately under relevant items and Labour charges for taking out old spares and fixingof new sparesshall deemed to be included in unit rate quoted.
106Supply onlyfollowing new spare parts of Refrigerator/Deep freezer 165/180/195/310/330/450 and 500 Ltrs capacity:-
107Thermostat switchwith Knob.( Make :- Indfoss/ Renutrol).
108Starting relay 1/6 H.P.Open type with O.L.P. ( Make :-Renutrol/ Sri Ram/ Microtech).
109Starting relay 1/8 H.P. open type with O.L.P.( Make :-Renutrol/ Sri Ram/ Microtech).
110Copper filter single capilary pencil type.
111Vegetable tray PVC for 165 to 330 Ltr capacity ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.).
112Defrost tray for refrigerator capacity 165 to 330 Ltr ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.).
113PVC ice tray flexible.( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
114Refrigerator bottle shelf for 165 to 330 ltr capacity ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
115Waste water tray suitable for different type of Refrigerator. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
116Freezer door for 165/180/195 Ltr capacity. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
117Freezer door for 280/300/330 Ltr capacity. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
118Door Lock for refrigerator 165 to 330 ltrs. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
119Door switch for refrigerator 165 to 330 ltrs . ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
120Interior light fittings with bulb. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
121Door handle suitable for 165 to 330 Ltrs. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
122Refrigerator Glass shelves of capacity 165/180/195 Ltrs. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.)
123Refrigerator Glass shelves of capacity 280/300/310/330 Ltrs. ( Make :- Suitable for Whirlpool/ LG/ Samsung/ Godrej make Refrigerator.) Note for item No 89.01 to 89.17 :- Materials of item No 89.01 to 89.17 to be incorporated in item No 88 here-in-before
124Disconnecting from mains and taking down the unserviceable compressorunit of Refrigerator of any make and type and providing New Compressor suitable for 165 to 195 ltr capacityalongwith one year warranty certificate from manufacturer/dealer including supply of therefrigerant gas R-134A and filling and replacement of filter and put in working condition all as directed by Engineer-in-Charge. (Make :Tecumseh/LG/Godrej.) Note :-The rates quoted by the contractor shall deemed to include the transportation cost from site of installation to contractor"s repair workshop and back.
125All as per item No. 90above but following capacity of Refrigerator:-
126Refrigerator 280/300/310/330 Ltrs capacity.
127Deep Frteezer 400 Ltrs capacity.
128Deep Freezer 500 Ltrs capacity.
129Taking out unserviceable evaporator /freezer from the refrigerator & supply & fixing evaporator/freezer made out of aluminium press type of capacity 280/300/310/330/400 and 500 ltrwith freezer frame and door including connection, complete all as specified & as directed. (Make - Whirlpool/Godrej/Kelvinator/LG/Sumsung.)
130-ditto- all as per item No. 92 but capacity of the refrigerator 165 to 195Ltrs capacity.
131Taking down desert cooler of any type (Steel body/Plastic body) and any capacity from any height / floor andrefixing the same in same location after repair work/ overhauling all as required at site. Note:- Repair work not included in the quoted rate.
132Preparation for old painted surface of desert cooler of any capacity and any make on inner surface & outer surface.Repainting the complete desert coolers ie side panel, bracket, body & desert cooler stand with two coats of synthetic enameled paint (1st grade quality) including two coats of black water proof paint on reserve water tank & marking with “ GE(U) P&M (MES)” letter size of 50mm height in stencil in black/white including servicingandgreasing of fan motor/pump and replacement of PVC pipe worn out nut, bolts and washers complete all as per site requirement. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
133Supply and fixing in repairs wood wool padapproximate weight 800 - 900gms of size 24” sweep desert cooler as per existingcomplete all as specified and directed.
134-ditto- all as per item No 96 above but approximate weight 700 - 800gms and20” sweep.
135Supply and fixing in repairs submersible pump motor 230 Volts , single phase, AC suitable for Plastic body/ Steel body Desert cooler complete all as specified & as directed.(Make- Bajaj/ Crompton/ Khaitan.)
136Supply and fixing in repairs of exhaust fan motor copper woundedhaving 1400 RPM, 150 watts with 500mm sweep suitable for operation on 230 volts, 50Hz, AC supply including fan brackets/ clamps of suitable size and all fixing accessories complete all as specified & as directed. (Make:- Khaitan/ Crompton/ Cool master.)
137Supply and fixing in repairs of desert cooler copper wounded kitfan motor of capacity 90 Watt complete all as specified & as directed. (MakeKhaitan/ USHA/ Crompton Greaves/Bajaj.)
138Supply and fixing in repairs front grill for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicator lamp complete all as specified and directed.
139Supply & fixingin repairs GI wire mesh for desert cooler pad (Set of Three).
140Supply & fixing in repairsPVC pipe for connecting pump and water distributor of size 15 mm complete all as specified & as directed. (Make:- Prayag/ Supreme/ Prince).
141Supply & fixingin repairsPVC elbow for desert cooler of suitable size complete all as specified & as directed.
142Supply & fixingin repairs PVC 4 Way distribution cross for desert cooler complete all as specified & as directed.
143S & Fin repairs flexible copper conductor cable, 3 corePVC insulated & PVC sheathed of size 1.5sqmm complete all as specified and directed. (Make -Polycab/Kalinga Premium/Plaza).
144S & F in repairs desert coolers fan blade of 18 inch sweep of plastic bodycomplete all as specified & as directed..
145-ditto- all as per item No 107 here-in-before but 20 inch sweep.
146Supply and fixing in repairs side panel of desert cooler of 20” sweep made out with GI sheet of 20 SWG duly painted with two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide zinc chrome primer complete all as specified & as directed. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
147Supply and fixing in repairs switch piano flush type single pole one way 5Amp / 6 Amp 230 V for desert cooler all as directed (Make-Anchor/Kinjal/Havells).
148Supply and fixing in repairs 3 pin plug top 5 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells).
149Supply and fixing in repairs 3 pin plug top 15 Amp, 230V for desert cooler complete all as specified and directed (Make-Anchor/Kinjal/Havells).
150Supply and fixing in repairs cooler fan motor bracket sets made up as existing includingpaintingcomplete all as specified and directed.
151S & F in repairs desert cooler body of size 25 inch x 25 inch x 36 inch (height) with side panels (03 Nos) fabricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch, 5 Amp piano switch and tank of depth 11 inch. Painting the complete desert cooler i.e, side panel, bracket body with two coat of synthetic enamel paint (Ist grade quality) over a coat of red oxide zinc chrome primer and two coat of black water proof paint on reserve tank and marking with "GE (U) P&M (MES)" letter size of 50mm height in stencil in black/white all as specified and directed by Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
152Section -II
153Supply only following items for day to day housekeeping and conservancy services to upkeep the AC Plant and Lift Room/OTM Accn. These itms shall be supplied fortnightly by the contractor to the GE Office.
154Mosquito spray 400 ml, (Make- Mortien/Hit/Baygon Spray)
155Floor Cleaner of 2 Ltr, (Make- Lizol or equivalent)
156Toilet Cleaner of 500 ml, (Make- Harpic/ Sanifresh/ Domex)
157Glass Cleaner of 500 ml, (Make- Colin/ Lizol)
158Liquid Soap 200 ml, (Make- Dettol/ Lifebouy/ Savlon)
159Bio Garbage plastic bags of carrying capacity about 50-60 Kg (100 bags in each pkt)
160Air/ Room Freshener 250 ml (spray type), (Make- Odonil/ Godrej Air or equivalent)
161Detergent Powder, (Make- Surf Excel/ Rin/ Arial)
162Insecticide 400 ml, (Make- Baygon/ Hit/Mortein)
163Tissue roll for toilets (weight approximately 227 gms in each roll)
164Hand Sanitizer 500 ML.(Make- Himalaya/ Lifebuoy/Dettol/ Cipla)
165Antiseptic hand sanitizer (Gel) 100 ML. (Make- Himalaya/ Lifebuoy/Dettol/ Cipla)
166Material and labour for office area sanitizationof AC Plant and Lift Rooms of various sizes including corridor/verandah using disinfectant suprayer with specified ratio of disinfectant chemical and water as per Indian Councial of Medical research guidelines underGE (U) P&M Office Area complete all as specified and as directed by Engineer-in-Charge. {Note:-(i) Work to be carried out two times in a month. (ii) The cost of T & P used for sanitization and chemical are deemed to be included in the quoted rate.}
167Section -III
168M&L for disconnecting all electrical LT cables and taking down the old existing unserviceable LT Panel of any size and model including all accessories from Central AC plant at HQ DGIS & Supply, Installation, testing and commissioning in repairs LT PANEL INDOOR TYPE ENCLOSURE (size not less than 2175 mm x 3100 mm x 900 mm ) with angle iron (size 40x40x5mm) frame& including steel structure required for installation on existing cable trench, housing cubicle type, free standing, Main LT panel suitable for 440Volts 3-phase, 50 Hz. AC supply. It shallbeextendibleatbothends, fully compartmentalised, dust proof and vermin proof, fabricated out of 2mm thick CRCA sheet steel enclosure, painted as per the9-tank process & IP-42 protections, as per specifications and suitable for fixing the following accessories complete all as specified and as directed :- (Make- Siemens/ L&T/ ABB/ Schneider/ Legrand/ Crompton Greaves/Power system and controls/Universal Switch gear). Note :- (i)All accessories mentioned below to be fixed in the LT Panel enclosure shall be measured and paid separately under relevant items of this schedule. (ii) The contractor shall get the drawings approved by the accepting officer before placing the orders.
169M&L for disconnecting all electrical LT cables and taking down the old existing unserviceable LT Panel of any size and model including all accessories from Central AC plant at HQ CAMS & Supply, Installation, testing and commissioning in repairs LT PANEL INDOOR TYPE ENCLOSURE (size not less than 2175 mm x 3100 mm x 900 mm ) with angle iron (size 40x40x5mm) frame & including steel structure required for installation on existing cable trench, housing cubicle type, free standing Main LT panel suitable for 440V 3-phase. 50 Hz. AC supply. Itshallbeextendibleatbothends, fully compartmentalised, dust proof and vermin proof, fabricated out of 2mm thick CRCA sheet steel enclosure, painted as per the 9-tank process & IP-52 protections,as per specifications and suitable for fixing the following accessories :- (Make- Siemens/ L&T/ ABB/ Schneider/ Legrand/ Crompton Greaves/ Power system and controls/ Universal Switchgear). Note :- (i)All accessories mentioned below to be fixed in the LT Panel enclosure shall be measured and paid separately under relevant items of this schedule. (ii) The contractor shall get the drawings approved by the accepting officer before placing the orders.
170S & F copper bus bar of capacity 1750 Amps with same size for neutral duly colour coded and supported with DMC/SMC insulators with heat shrinkable sleeve bearing short circuit current to withstand minimum 50 kA for one second, suitable for DGIS panel enclosure as per breaker ratings / approved drawings, complete all as specified and directed by Engr-in-Charge. (Make- Hindalco or of equivalent make)
171M & L for complete wiring of enclosure with hardwares (Cables ,wires,terminals, thimbles etc), suitable for DGIS panel enclosure as per breaker ratings / approved drawings, complete all as specified and directed by Engr-in-Charge.
172S & F copper bus bar of capacity 1250 Amps with same size for neutral duly colour coded and supported with DMC/SMC insulators with heat shrinkable sleeve bearing short circuit current to withstand minimum 50 kA for one second, suitable for CAMS panel enclosure as per breaker ratings / approved drawings, complete all as specified and directed by Engr-in-Charge. (Make- Hindalco or of equivalent make)
173M&L for complete wiring of enclosure with hardware (Cables ,wires,terminals, thimbles etc), suitable for CAMS LT panel enclosure as per breaker ratings / approved drawings, complete all as specified and directed by Engr-in-Charge.
174S & FAircircuit breakers 1250 Amps 4 pole Microprocessor Basedhaving breaking capcity 50 KA at 415 volts with S/C, O/L & E/F protection, compete all as specified and directed by Engr-in-Charge.(MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER )
175S & F Aircircuit breakers 800 Amps 4 pole Microprocessor Basedhaving breaking capcity 50 KA at 415 volts, with S/C, O/L & E/F protection compete all as specified and directed by Engr-in-Charge.(MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER )
176S & F Trip neutral closed (TNC) switch suitable for 800-1250 Amps rating ACB"s compete all as specified and directed by Engr-in-Charge. (Make- Salzer or of equivalent make)
177S & FDigital type Multifunction meter Flush mounted3 phase for measuring parameters (V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh), with suitable rating current transformers with built in selector switches suitable for mounting on LT panel, complete all as specified and directed by Engr-in-Charge. (Make L&T or equivalent inABB/Legrand)
178S & FDigital type Ammeter Flush mounted3 phase, with suitable rating current transformers suitable for measuring range minimum (0-200) Amps with selector switch suitable for mounting on LT panel, compete all as specified and directed by Engr-in-Charge. (Make L&T or equivalent inABB/Legrand)
179S & FPhase indication lights of suitable colour,230V AC suitable for mounting on LT panel, complete all as specified and directed by Engr-in-Charge. (Make ESBEEor of equivalent make)
180S & FOn/Off Trip indication lights of suitable colour,230V AC, suitable for mounting on LT panel compete all as specified and directed by Engr-in-Charge. (Make ESBEEor of equivalent make)
181S & F On/Off Push buttons suitable for mounting on LT panels, compete all as specified and directed by Engr-in-Charge. (Make ESBEEor of equivalent make)
182S & F Miniature circuit breaker (MCB) 6 Amps, single pole (SP), 10 KA, "C" curve complete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER )
183S & F Copper neutral link suitable for DGIS/CAMS LT panel and as per site requirement, complete all as specified and directed by Engr-in-Charge. (Make L&T or equivalent inABB/Legrand/AE)
184S & F Moulded case circuit breakers (MCCB) 320 Amps, 4 Pole, 36 KA, thermal magnetic with rotary handle and spreader compete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER)
185S & FMoulded case circuit breakers (MCCB) 250 Amps, 4 Pole, 36 KA, thermal magnetic with rotary handle and spreader compete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER)
186S & F Moulded case circuit breakers (MCCB) 200 Amps, 4 Pole, 25 KA, thermal magnetic with rotary handle and spreader compete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER)
187S & F Moulded case circuit breakers(MCCB) 160 Amps, 4 Pole, 25 KA, thermal magnetic with rotary handle and spreader compete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER)
188S & FMoulded case circuit breakers (MCCB) 100 Amps, 4 Pole, 25 KA, thermal magnetic with rotary handle and spreader compete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER)
189S & FMiniature circuit breaker (MCB) 32 Amps, 4 Pole, 25 KAcompete all as specified and directed by Engr-in-Charge.(MakeL&T/ LEGRAND/ ABB/ SIEMENS/ SCHNEIDER )
190S & F Power contactor 95 Amps, triple pole (TP), AC 3 duty, with add on block (2 NO+2NC), compete all as specified and directed by Engr-in-Charge.(Make-L&T/ SEIMENS /ABB/ LEGRAND)
191S & F Power contactor 80 Amps, triple pole (TP), AC 3 duty compete all as specified and directed by Engr-in-Charge. (Make-L&T/ SEIMENS /ABB/ LEGRAND)
192S & F Power contactor 70 Amps, triple pole(TP), AC 3 duty compete all as specified and directed by Engr-in-Charge. (Make-L&T/ SEIMENS /ABB/ LEGRAND)
193S & F Power contactor 50 Amps, triple pole (TP), AC 3 duty compete all as specified and directed by Engr-in-Charge. (Make- L&T or equivalent in ABB/Legrand)
194S & F Power contactor 45 Amps, triple pole (TP), AC 3 duty compete all as specified and directed by Engr-in-Charge. (Make-L&T/ SEIMENS /ABB/ LEGRAND)
195S & F Auxillary contactor (2 NO+2NC), suitable for 45-95 Amps power contactors,compete all as specified and directed by Engr-in-Charge. (Make- L&T or equivalent in ABB/Legrand)
196S & F Overload relay 45-75 Amps,compete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS)
197S & FOverload relay 30-50 Amps,compete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS)
198S & F Overload relay 14-23 Amps,compete all as specified and directed by Engr-in-Charge. (MakeL&T/ LEGRAND/ ABB/ SIEMENS)
199S & FOverload relay 9-15 Amps,compete all as specified and directed by Engr-in-Charge. (Make- L&T or equivalent in ABB/Legrand)
200S & F Star/Delta Timer range 3-30 seconds,suitable for LT panelscomplete all as specified and directed by Engr-in-Charge. (Make- L&T or equivalent in ABB/Legrand)
201S & F Auto/Manual selector switch suitable for LT panels ,complete all as specified and directed by Engr-in-Charge. (Make- L&T or equivalent in ABB/Legrand)
202S & F solid state single phasing preventer type VSP 2 complete all as specified and directed by Engr-in-Charge.(Make:- Minilec/ L&T/ Siemens/Legrand/ ABB/ C & S.)
203S & F solid state single phasing preventer type VSP 3 complete all as specified and directed by Engr-in-Charge.(Make:- Minilec/ L&T/ Siemens/Legrand/ ABB/ C & S.)
204Supply, laying & fixing LT XLPE insulated, armoured electric power cable (heavy duty), aluminium stranded conductor, 1100 volts grade of cross sectional area 185 Sq mm, 3.5 core with suitable size cable glands, crimping type cables lugs etc on floor/ wall/ poles including taking down old unserviceable one complete all as specified and as directed. (Make: RR KABLE LTD/ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD/ HAVELLS)
205`-ditto- all as per item No. 154 above but cross sectional area 150 Sqmm, 3.5 core.
206`-ditto- all as per item No. 154 above but cross sectional area 70 Sqmm, 3.5 core.
207`-ditto- all as per item No. 154 above but cross sectional area 35 Sqmm, 3.5 core.
208`-ditto- all as per item No. 154 above but cross sectional area 16 Sqmm, 4 core.
209S & F in replacement Power contactor, 140 Amps, triple pole (TP), AC 3 duty, withadd on block (2 NO + 2 NC), complete all as specified and directed by Engr-in-Charge. (Make-L&T/ SEIMENS /ABB/ LEGRAND)
210Material & Labour for earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thickincluding taking down old onencomplete all as specified and directed. (Make of GI Pipe:-JINDAL/ TATA/ BST/ PRAKASH TUBES/ OSWAL) (Note:- Each protection pipe and earthing lead upto and including 7.5 meter lenght is deemed to be included in the qouted rate of this item.)
211Supply & fixing of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drewn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required32x6 mmgalvanised iron strip including taking down old unserviceable one complete all as specified & as directed.