Repairs / Replacement Of Internal And External Electrification Of Earthing, Solar Street Lights, Security Lights, High Mast Light And Allied Misc Works At Trichy Under Age ( I ) Coimbatore Repairs / Replacement Of Internal And External Electrificati, TRICHY-Tamil Nadu

Military Engineer Services-MES has published Repairs / Replacement Of Internal And External Electrification Of Earthing, Solar Street Lights, Security Lights, High Mast Light And Allied Misc Works At Trichy Under Age ( I ) Coimbatore Repairs / Replacement Of Internal And External Electrificati. Submission Date for this Tender is 02-11-2021. Electrification Work Tenders in TRICHY Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

29436359
Corrigendum : Repairs / Replacement Of Internal And External Electrification Of Earthing, Solar Street Lights, Security Lights, High Mast Light And Allied Misc Works At Trichy Under Age ( I ) Coimbatore Repairs / Replacement Of Internal And External Electrificati
Open Tender
Indian
Tamil Nadu
TRICHY
02-11-2021

Tender Details

Repairs / Replacement Of Internal And External Electrification Of Earthing, Solar Street Lights, Security Lights, High Mast Light And Allied Misc Works At Trichy Under Age ( I ) Coimbatore Repairs / Replacement Of Internal And External Electrification Of Earthing, Solar Street Lights, Security Lights, High Mast Light And Allied Misc Works At Trichy Under Age ( I ) Coimbatore

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Oct-2021 Corrigendum No 1 BOQ 26-10-2021
2 26-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 32000.0 /-
Tender Value
INR 16 Lakhs /-

BOQ Items

Name of Work: REPAIRS/REPLACEMENT OF INTERNAL AND EXTERNAL ELECTRIFICATION OF EARTHING, SOLAR STREET LIGHTS, SECURITY LIGHTS, HIGH MAST LIGHT AND ALLIED, MISC WORKS AT TRICHY UNDER AGE (I) COIMBATORE
Sl. No. Item Description
1Taking down old/unserviceable /damaged point wiring carefully,of any type (i.e. on wooden batten, surface conduit, casing & capping or concealed conduit) complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, conduit etc. including accessories such as wooden gutties/rowel plug, screw etc including making good disturbed surface to match the existing surface complete all as specified and directed.
2Taking down main switches, distribution board, steel enclosure with MCB’s any number of way and rating including wooden board or from steel board and making good disturbed surfaces complete all as specified and directed.
3Taking down carefully service cable of any nos of wire and size with earth wire on wooden batten/surface conduit/casing & capping complete with its all accessories including making good disturbed surface to match the existing surface complete all as specified and directed.
4M&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multistranded copper conductor 1.5 sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable, 1100 Volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC casing capping and accessories on wall/roof/floor etc, ISI marked with mild steel/ pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed all as specified and directed for the following:-
5One light/fan/Exhaust fan /call bell point controlled by one switch 5 Amp, one way
6Socket outlet, 3pin, 5 amps, on same board
7Socket outlet, 3pin, 5 amps, on independent board
8All as per item No 4 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sqmm multistranded copper conductor wire FRLS. PVC insulated and 2.5 Sqmm copper conductor wire FRLS PVC insulated as earth wire.
9M&L Pointwiringusing approved colour coding as per IS (Red , Black and Green for single phase circuits), with multistranded copper conductor 1.5 sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and including medium grade,non metallic PVC conduit and accessories on wall/roof/floor etc, ISI marked suitable for surface conduit wiring with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, including PVC insulated multistranded copper conductor 1.5 sqmm nominal cross sectional area single core, FRLS cable as earth continuity conductor to common earth and connecting to earth duly completed all as specified and directed for the following:-
10One light/fan/Exhaust fan point controlled by one switch, 5 Amp, one way
11Socket outlet, 3 pin, 5 amps, on same board
12Socket outlet, 3pin, 5 amps, on independent board
13All as per item No 6 here-in-before but for one socket outlet of 15 Amps fixed on independent board with 4.0 Sqmm multistranded copper conductor wire FRLS PVC insulated and 2.5 Sqmm copper conductor wire FRLS PVC insulated using as earth wire.
14S&F Switch, piano type, single pole, one way, 5 Amp,240V, 50Hz AC, all as specified and directed
15S&F Switch, piano type, single pole, one way, 15 Amp, 240V, 50Hz AC, all as specified and directed
16S&F Socket outlet, multi purpose, 2 in 1, 3 Pin, 5 Amp, 230V, 50Hz AC, all as specified and directed.
17S&F Socket outlet, multi purpose, 2 in 1, 3 Pin, 5 Amps and 15 Amp, flush type, 230V, 50Hz, AC, all as specified and directed.
18S&F Ceiling rose, poly carbonate, isolated body withtwo to three terminals complete all as specified and directed.
19S&F MCB DB"s, sheet metal enclosures, single pole and neutral, 230Voltwith 200 Amps rated bus bar and Double Door Type of following type/cap complete all as specified and directed:_
2012 Way
218 way
224 way
23S&F MCB DB"s, sheet metal enclosures, TPN, 4 way, 415 Volt with 200 Amps rated bus bar and Double Door complete all as specified and directed
24S&F MCB, SP, 5 to 40 Amps, 240 Volts complete all as specified and directed.
25S&F MCB, SPN, 6 to 40 Amps, 240 Volts complete all as specified and directed.
26S&F Isolator, TPN, 63 Amps, 415 Volts complete all as specified and directed.
27S&F LED tube light fittings, 4 feet with fixture 20 watts, 230v, 50HZ including connecting up with PVC two core copper conductor cable from ceiling rose to fittings complete all as specified and directed.
28S&F LED tube light fittings, 2 feet with fixture 10 watts, 230v, 50HZ including connecting up with PVC two core copper conductor cable from ceiling rose to fittings complete all as specified and directed.
29S&F Lamp holder PVC polycarbonate type with back plate suitable for batten fittings including LED lamp 9 watt including taking down old unserviceable one all as specified and directed
30S&F Fan regulator, stepped, electronic type, flush type (socket type) suitable for ceiling fan 240V, AC, 50 Hz, all as specified and directed.
31M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level, top edge of the plate not less then 1.5M below nominal ground level connected to galvanised earth lead wire 4mm dia by means of bolts and cheek nut and washer of galvanised iron including GI protection pipe and watering pipe all as shown in electrical plate No 3 of SSR Pt I including connection with main switch board all as specified including taking out old u/s earthing from existing location all as directed by Engr-in-Charge..
32Disconnecting electrical wire from ceiling rose, taking down ceiling fan of any type/size and make, removing substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning including replacement of worn-out/ unserviceable spares as required, replacement of PVC insulated unsheathed stranded twisted copper conductor cable of size 1.5 Sqmm up to 1.0 Mtr long assembling the repaired ceiling Fan, testing and hanging at position, connection with point wiring & Testing complete all as directed. Note : Replacement of worn out defective/unserviceable spare parts, flexible wire etc/ rewinding of ceiling fan and painting shall be measured and paid separately under relevant item of the schedule)
33All same as in item No. 23 here in before but for exhaust fan 300 mm sweep complete all as specified and directed.
34All same as in item No 23 here in before but for exhaust fan 380 / 400mm sweep complete all as specified and directed.
35All same as in item No. 23 here in before but for wall mounting fan up to 400 mm sweep complete all as specified and directed.
36Rewinding of the motor of ceiling fan of any make and size (1200 mm sweep) with super enameled copper wire of existing gauge to obtain the specified and satisfactory RPM as per manufacturers specification, including replacement of all insulation materials, varnishing heating, drying, assembling of stator & rotor etc including testing complete all as specified and directed.
37All as per item No. 27 above but for exhaust fan of any make/type and size 300 mm sweep complete all as specified and directed.
38All as per item No. 27 above but for exhaust fan of 380/400 mm sweepcomplete all as specified and directed.
39All as per item No. 27 above but for wall mounted fan of any make/type and of size up to 400 mm sweep complete all as specified and directed.
40S&F Ball bearing of any size and type suitable for any type/make/size of ceiling fan complete all as specified and directed.
41S&F Condenser, oil base type, 440 Volts, AC, 50 HZ and rated capacity 2.5 MFD to be incorporated against item No 27 above as required including connecting up complete all as specified and directed.
42S&F Condenser, oil base type, 440 Volts, AC, 50 HZ and rated capacity, 3.15 MFD to be incorporated against item No.27 above as required including connecting up complete all as specified and directed.
43S&F Capacitor, oil base type, 440 Volts, AC, 50 HZ and rated capacity, 4 MFD to be incorporated against item No.27 above as requiredincluding connecting up complete all as specified and directed.
44S&F PVC insulated sheathed twin core round stranded copper conductor flexible cable of size 1.5 Sqmm as required including connecting up complete all as specified and directed.
45S&F PVC insulated sheathed round stranded copper conductor cable of size 2.5 Sqmm, 3 core. as required including connecting up complete all as specified and directed.
46Supply only gun metal bush of suitable size for exhaust fan of any type / size as per existing type complete all as specified and directed.
47All as per item No. 37 above but suitable for wall mounted fan of any type / size as per existing type complete all as specified and directed.
48S&F Exhaust fan blade for 300 mm sweep fan complete all as specified and directed
49Taking out geyser of any make and capacity for necessary repair /replacement including refixing at its original position after repair with replacement of passivated bolt, nut, washer etc. complete all as specified and directed. Note: passivated bolt, nut, bolt and washer etc. measured andpaid separately.
50S&F PVC steel wire reinforced inlet (Cold water) connection pipe 45cm long with thread brass chromium plated adopter including taking out unserviceable connection pipe from Geyser and complete all as specified and directed.
51All as per item No. 41 above but for outlet (hot water) connection brass chromium plated adopter complete all as specified and directed.
52S&F connection and testing thermostat with cutout for setting temperature 0- 90C including taking out old unserviceable thermostat from Geyser complete all as specified and directed.
53S&F connection indicator lamp with transparent cover as per existing size & shape including taking out old unserviceable indicator lamp complete all as specified and directed.
54S&F gun metal safely valve all as per existing including taking out unserviceable valve complete all as specified and directed.
55S&F connection and testing heating element thread/push type as per existing size & shape of capacity 1.5 KW including taking out unserviceable element complete all as specified and directed.
56All as per item No. 46 above but 2.0 KW complete all as specified and directed.
57Transportation ofcooling appliance split type AC, water cooler of any type make and capacity for carrying out the following phase of works :- (a) Dismantling of cooling appliances, opening up cable unit for strip Inspection, segregation of serviceable and unserviceable strip Inspection, segregation of serviceable and unserviceable motor/ condensing coil and other spare parts all as directed. (b) Replacement ofcomponents like blower motor condensing coil by repaired/new/reconditioned components as per existing to ensure smooth and efficient functioning of cooling appliance all as directed by Engineer in charge. (c) Carrying out fresh lubrication using grease/oil after cleaning and washing of old lubricating substance. (d) Carrying out spray painting to cooling appliance by 1st quality synthetic enameled paint as per existing colour code over existing painted surface including touching up of Red oxide/primer on the rusted surface after necessary preparation including writing of MES number in black paint all as directed and specified. (e) Assembling the complete unit by repaired new components/spare and existing serviceable components including testing to ensure smooth and efficient functioning of appliance to the entire satisfaction of engineer in charge. NOTE :- Replacement of allspare parts likerelays, capacitors, bushes clamps front grill, outer cover and Charging of refrigerant to compressor, rewinding and replacement of defective spare partsof split type AC & water cooler shall be measured and paid separately under respective items.
58Carrying out repair to blower motor of 1.5/2.00 TR split type AC (dismantled vide item No 48 above) including rewinding with super, enameled copper wire of appropriate gauge including replacement of bushes/bearing, mounting bushes, rubber base, varnishing and heating and painting by two coat of synthetic enamel paint over existing painting painted surface complete all as specified and directed.
59All as per item No 49 here in before but blower motor for water cooler storage type Model ST480 capacity 40/80 Ltr complete all as specified and directed.
60M&L Charging of F/22 gas to split type AC of capacity 1.5/2.0 TR capacity of any make after detecting and rectifying leaks, flushing the system with liquid nitrogen, dehydrating and evacuating the system including replacement of dryer/capillary tube complete all as specified and directed.
61All as per item No 51 here-in-before but of R/12 gas for water cooler 40/80 ltr capacity complete all as specified and directed.
62Repair tovoltage stabilizer of 4/5 KVA capacity of any type and make after taking out all spare parts, serviceable items keep at side further disposal as directed and rewinding of burn out unserviceable transformer reuse & unserviceable items keep for-former with super enamel copper wire (as per existing gauge) including heat varnishing and insulating material complete including replacement of volt meter existing range, relays, switches, socket out let 3 pin 5/15 Amp, porcelain fuse cutout of existing make & type and painting with two coats of synthetic enamel paint over a coats of red oxide primer including testing complete all as specified and directed.
63Supply only the following parts/components/materials for split type AC"s relevant item No 48 complete all as specified and directed.:-
64Dual Capacitor, 50+5 MFD, 400 Volts complete all as specified and directed.
65Dual Capacitor, 55+5 MFD, 440 Volts complete all as specified and directed.
66Terminal block, 4 pole, 20 Amps complete all as specified and directed.
67Contactor, 2pole, 25 Amps complete all as specified and directed.
68Air filter suitable for slit AC indoor unit complete all as specified and directed.
69Drain hose assembly complete all as specified and directed.
70M&L Wiring for circuit /sub main wiring using FR PVC insulated copper conductor cable of size 2 x6 sqmm along with 1 x 4 Sqmm, single core cable as earth continuity to be drawn in and including non metallicPVC conduitin surface / recessed as directed by Engr-in-charge.(Note: Two runs of PVC insulated cable with one run of earth wire and one run of conduit including accessories shall be measured as one length)
71Dismantling the S&F new compressor from split AC of capacity 1.5 Ton of same/existing model duly fitted with compressor oil and including copper filter capillary tube etc charging the sys with refrigerant gas including testing & commissioning and removing the old unserviceable compressor complete all as specified and as directed.
72S&F Single phase electronic energy meter with LCD display as per IS 13779, 10-60 Amps cap optical communication port including taking out old unserviceable meter complete all as specified and directed.
73S&F new compressor of water cooler of capacity 40/80 ltr same/existing modal duly fitted with compressor oil and including copper filter capillary tube etc charging the sys with refrigerant gas including testing & commissioning of water cooler including taking out old unserviceable compressor complete all as specified and directed.
74S&F Blower motor for water cooler of capacity80/150 ltr or 40/80 Ltr including testing and taking down old unserviceable one complete all as specified and directed.
75S&F Over load relay for water cooler up to 40-150 ltr capacity including taking down old unserviceable one complete all as specified and directed.
76S&F Energy saving and environmental friendly, long life, LED street light, 25 watts, made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07. including bracket made by GI pipe 40 mm bore to required shape with all accessories including taking down old unserviceable one complete all as specified and directed.
77S&F Switch piano type single pole, one way, 5 Amp, 240V, 50Hz, AC, including taking down old unserviceable one, complete all as specified and directed.
78S&F Switch piano type, single pole, one way, 15 Amp, 240V, 50Hz AC, including taking down old unserviceable one, complete all as specified and directed.
79S&F Sockets outlet, multi purpose, 2 in 1, 3 Pin, 5 Amp 230V, 50Hz AC, including taking down old unserviceable one, complete all as specified and directed.
80S&F Sockets outlet, Multi purpose, 2 in 1, 3 Pin, 5 amps and 15 Amp, flush type, 230V, 50Hz AC, including taking down old unserviceable one, complete all as specified and directed.
81S&F Fan regulator, stepped electronic, fan regulator, flush type, (switch type) suitable for ceiling fan, 240V, AC, 50 Hz, including taking down old unserviceable one, complete all as specified and directed.
82S&F Switch socket combination, Multi purpose, 2 in 1, 3 Pin, 5 Amps, 230V, 50Hz AC, including taking down old unserviceable one, complete all as specified and directed.
83S&F Switch socket combination, Multi purpose, 2 in 1, 3 Pin, 5 Amps and 15 Amp, flush type, 230V, 50Hz AC, including taking down old unserviceable one, complete all as specified and directed.
84S&F Modular type switch, 6 amps, one module including taking down old unserviceable one, complete all as specified and directed.
85S&F Modular type multi purpose socket, 6 amps, two module including taking down old unserviceable one, complete all as specified and directed.
86S&F Modular type switch, 16 amps, one module including taking down old unserviceable one, complete all as specified and directed.
87S&F Multi purpose socket, 16 amps, 2 module including taking down old unserviceable one, complete all as specified and directed.
88S&F Modular type fan regulator, 120 W, 2 module including taking down old unserviceable one, complete all as specified and directed.
89Dismantling compressor from refrigerator of capacity286/310 ltr S&F new compressor same/existing model, duly fitted with compressor oil and including copper filter, capillary tube, etc charging the system with refrigerant gas including testing & commissioning all as directed.
90Dismantling desert cooler of any capacity servicing and replacement of tullu pump and repair and rewinding of blower motor any make and Sizewith super enameled copper wire of existing gauge to obtain the specified and satisfactory RPM as per manufacturers specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator & rotor etc and testing complete all as directed.
91S&F Call bell, 230 V, AC, single pole all as specified and directed
92S&F Bell push, flush type, 5 Ampcomplete all as specified and directed
93Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M deep for foundation/trenches and getting out in soft/loose soil complete all as specified and directed.
94Removing excavated material to a distance not exceeding 50m and depositing at a level not exceeding 1.5M above ground complete all as specified and directed.
95Returning/filling in layers, including spreading leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed.
96M&L Sand cushioning to PVC cable with sand and punning to provide required protection of cables complete all as specified and directed.
97Supply and laying burnt bricks, sub class B of old size, laid dry in trenches for cable protection complete all as specified and directed.
98Supply and Laying in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs and testingXLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, complete all as specified and as directed for cables of cross sectional area and coreof following sizes:- Note : Excavation and earth work, sand, pipe and bricks will be measured and paid separately
9950 Sqmm, 3 1/2 core
10025 Sqmm,3 1/2 core
10116 Sqmm, 4 Core
10210 Sqmm, 2 Core
1036.0 Sqmm, 2 Core
104M&L Cutting the existing bituminous road/concrete floor and including returning filling and making good using PCC 1:3:6 to match with the existing surface complete all as specified and as directed Note : Excavation and earth work, sand, pipe and bricks will be measured and paid separately
105S&F GI tubing, light grade of following size for protection of cable in trenches/on pole complete all as specified and as directed
10640mm dia
10725 mm dia
108S&F Bracket made out of 1.5M long, 40 mm bore, light grade, galvanised iron steel tubing for fixing light fitting all as directed by Engineer-in-Charge including dismantling taking out old unserviceable bracket complete all as specified and directed.
109M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level, top edge of the plate not less then 1.5M below nominal ground level connected to galvanised earth lead wire, 4 mm dia by means of bolts and cheek nut and washer of galvanised iron including 20mm bore GI protection pipe, GI 20mm watering pipe, medium grade with funnel, requisite quantity of common salt, charcoal dust, including excavation and earth work in any type of soil, PCC pit in cement concrete 1:2:4, type B-1, necessary form work, precast RCC cover, angle iron frame 40x40x5mm etc including connection with O/H conductor on poles / main switch board / Panel / FPBall as specified or indicated including testing on completionincluding taking and/removing old unserviceable earthing from existing location all as directed by Engr-in-Charge..
110M&L Earthing complete with galvanised iron earth plate electrode 60cmx60cmx3.15mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including GI strip 25x4mm as earth lead by means of bolts, nuts, check nuts and washers of copper/brass, 40 mm GI pipe light grade as protection pipe up to DB,GI 20mm watering pipe medium grade with funnel, , requisite quantity of common salt, charcoal dust, including excavation and earth work in any type of soil, PCC pit in cement concrete 1:2:4, type B-1, necessary form work, precast RCC cover, angle iron frame 40x40x5mm etc including testing of earthing complete all as specified and shown on Electrical Plate No 5 of SSR (Part-I). Note : On testing, if the desired earth resistance is not obtained, the earthing shall be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engr-in-Charge.
111S&F LED street light fitting, 60 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, with IP 65/66 protection complete all as specified and directed.
112M&L Dismantling Solar street lights, 15 watts capacity for carryout required repairs and replacing the following items, re-assembling after replacement of spare parts, drain out and refilling distilled water in batteries connecting up complete all as specified and directed
113LED light fitting 15 watts operated by DC power supply
114Tubular battery, 12 V, 80 AH
115Charge controller, 5 Amps
116S&F MCB, TPN, 415 volts, up to 63 A capacity, Service Breaking Capacity 10KA complete all as specified and directed.
117S&F Insulators, 150mm dia, 150mm height, pin type, porcelain vitreous, white, brown, green including one galvansied mild steel spindle, two galvanised iron washer and one GI nut suitable for 11000 volt grade HT OH line including taking down unserviceable insulators complete all as specified and directed.
118M&L Lighting arrestors, expulsion type complete with all fitting, transmission class, discharge capacity 65 KA, suitable for HT 11 KV complete with necessary connection and testing including taking down old unserviceable one complete all as specified and directed.
119S&F Post top lantern, LED type, 20 watt, 230 V, AC, outdoor type with decorative post top for 360 degree indirect light, IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
120S&F LED flood light, 170 watt, 230 V, AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp suitable for high mast application, highlighting architectural facade and general purpose lighting complete all as specified.
121S&F MCCB 63 Amps capacity, 16 KA, 04 pole with fixed thermal andmagnetic setting complete all as specified and directed.
122S&F MCCB 100 Amps capacity, 25 KA, 04 pole with fixed terminal magnetic setting complete all as specified and directed.
123S&F Kit kat rewirable fuse carrier with base including extension strip of capacity 320 amps, 415 volts, 50 Hz, fixed in repairs complete all as specified and directed.
124S&F Kit kat rewirable fuse carrier with base including extension strip of capacity 200 amps, 415 volts, 50 Hz, fixed in repairs complete all as specified and directed.
125S&F Kit kat rewirable fuse carrier with base including extension strip of capacity100 amps, 415 volts, 50 Hz fixed in repairs complete all as specified and directed.
126S&F Battery 3.8 volt suitable for security light timer, fixed in repairs complete all as specified and directed
127S&F Digital display timer functioning in rechargeable battery suitable for controlling street light, fixed in repairs complete all as specified and directed
128S&F 3 Phase contactor suitable for security light controller/APFC panelas per sample existing model, fixed in repairs complete all as specified and directed
129S&F Street light thermoplastic junction box made of thermoplastic, IP 65, suitable for 10 sqmm to 25 sqmm cable metric knockouts for cable entry and front hinged shutter, having busbar, 100 Amps, single phase, 2 wire, system to connect cable of size 10 sqmm including one number MCB, SP, 6 amps complete all as specified and directed.
130M&L GI Earth continuity conductor or main earthing lead of size 25mmx4mm, fixed on wall or recess or buried in ground or drawn in conduit pipes complete all as specified and directed.
131M&L Wiring for security lights from cable junction box to light fittings using FR, PVC insulated copper conductor cable of size 2 Nos of 1.5 sqmm along with 1 No 1.5 sqmm single core cable for earth continuity to be drawn in and including non metallic PVC conduit in surface / recessed as directed by Engr-in-charge.(Note: Two runs of PVC insulated cable with one run of earth wire and one run of conduit including accessories shall be measured as one unit length)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy