Environment and Forests Government Departments Closing in 0 days TDR #29435398

Tender For The Purchase Of Multi Water Quality Parameters Go Through The Quotation Request , The Hydrolab Multiparameters For Marine Application Should Be A Portable, Intelligent Water Quality Instrument And Sensors Options Include Conductivity, Optica

Issued by Government Departments · Kanchanvadi, Near Patel Colony no.9, Jamnagar, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Oct 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanchanvadi, Near Patel Colony no.9, Jamnagar → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For The Purchase Of Multi Water Quality Parameters Go Through The Quotation Request , The Hydrolab Multiparameters For Marine Application Should Be A Portable, Intelligent Water Quality Instrument And Sensors Options Include Conductivity, Optical Dissolved Oxygen ( Do ) , Ph / Orp, Turbidity, Nitrate, Chlorophyll, And Temperature. With 4 Smart Sensor Ports Which Permit Interchangeability And / Or Replacement By The Users In The Field. All Data Should Be Displayed In A Single Display.The Water Quality Instrument Must Include Sensor Screw Tool For Easy Replacement Or Change Of Smart Sensors Under Normal Operating Conditions And To Prevent Premature Damage Of Any Of The Smart Sensors Under Normal Operating Conditions.Sensor Description:Barometric Sensor Should Sensor Range Shall Be 300 – 1100 Mbars With Accuracy Of ± 3 Mbar And Resolution 0.01 Mbar, Ambient Temperature: Temperature Range Should Be -20° To +70°C With Accuracy Of ±2°C And Resolution Of 0.1°C, Optical Dissolved Oxygen Sensor – Smart Sensorthe Optical Do Sensor Shall Comply With Epa-Approved Should Measurefrom 0 To 60 Mg / Lshould Have Accuracy Of 0.1Mg / L Of Reading From 20 To 60 Mg / L. Resolution: 0.01Mg / L, Conductivity Sensor Should Measure Range:0-350Ms / Cm T, Ds : 0-350Ppt, Salinity350psu, Accurcay Should Have ± 0.5% & Resolution , The Conductivity Sensor Should Have Report Measurements As: Actual Conductivity ( Μs / Cm, Ms / Cm ) , Specific Conductivity ( Μs / Cm, Ms / Cm ) , Salinity ( Psu, Ppt ) , Total Dissolved Solids ( Tds ) ( Ppt, Ppm ) , Resistivity ( Ohms-Cm ) , And Density ( G / Cm3 ) , Display: It Should Be Built-In Lcd Screen In Itself To Provide Clear, Instant Visual Indicators Of Overall Readiness, Sensor Status, Power Voltage, And Connectivity. Also Want Titanium Sensor Guard To Avoid Corrosion. Communicate Connections: Should Have The Ability To Communicate Wirelessly Through Bluetooth Wireless Technology. Also, It Should Be Able To Log Data Directly To Windows / Android / Mac Devices. The System Must Be Able To Record Live Reading When Connected To A Cable, Wireless Bluetooth Display And Based On Windows / Android / Apple Devices With The Application.Accuracy: ±0.1 Ph Unit.Minimum Orp Range: ±1400 Mv. Orp Sensor Accuracy:±5.0 Mv

BOQ

Name of Work: Purchase of Printer Aqua troll multiparameter
Sl. No. Item Description
1The Hydrolab multiparameters for marine application should be a portable, intelligent water quality instrument and sensors options include Conductivity, Optical dissolved oxygen (DO), pH/ORP, Turbidity, Nitrate, Chlorophyll, and temperature. With 4 smart sensor ports which permit interchangeability and/or replacement by the users in the field. All data should be displayed in a single display.The water quality instrument must include sensor screw tool for easy replacement or change of Smart Sensors under normal operating conditions and to prevent premature damage of any of the Smart Sensors under normal operating conditions.Sensor Description:Barometric Sensor should Sensor range shall be 300 – 1100 mBars with accuracy of ± 3 mBar and resolution 0.01 mBar,Ambient Temperature: Temperature range should be -20° to +70°C with accuracy of ±2°C and resolution of 0.1°C,Optical Dissolved Oxygen Sensor – Smart SensorThe optical DO Sensor shall comply with EPA-approved should measurefrom 0 to 60 mg/LShould have accuracy of 0.1mg/l of reading from 20 to 60 mg/L. Resolution: 0.01mg/l,Conductivity Sensor should measure range:0-350mS/cm T,DS : 0-350PPT, Salinity350PSU,Accurcay should have ± 0.5% & Resolution ,The conductivity sensor should have report measurements as: actual conductivity (µS/cm, mS/cm), specific conductivity (µS/cm, mS/cm), salinity (PSU, ppt), total dissolved solids (TDS) (ppt, ppm), resistivity (Ohms-cm), and density (g/cm3),Display: It should be built-in LCD screen in itself to provide clear, instant visual indicators of overall readiness, sensor status, power voltage, and connectivity. Also want Titanium Sensor guard to avoid corrosion. Communicate Connections: should have the ability to communicate wirelessly through Bluetooth Wireless Technology. Also, It should be able to log data directly to windows/Android/MAC devices. The system must be able to record live reading when connected to a Cable, Wireless Bluetooth display and based on windows/Android/ Apple devices with the Application.Accuracy: ±0.1 pH unit.Minimum ORP range: ±1400 mV. ORP sensor accuracy:±5.0 mV

AI Tender Summary

OUR REF NO 29435398
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 11-10-2021
Authority
Authority Name Zoological Survey Of India
Work Description Tender For The Purchase Of Multi Water Quality Parameters Go Through The Quotation Request , The Hydrolab Multiparameters For Marine Application Should Be A Portable, Intelligent Water Quality Instrument And Sensors Options Include Conductivity, Optical Dissolved Oxygen ( Do ) , Ph / Orp, Turbidity, Nitrate, Chlorophyll, And Temperature. With 4 Smart Sensor Ports Which Permit Interchangeability And / Or Replacement By The Users In The Field. All Data Should Be Displayed In A Single Display.The Water Quality Instrument Must Include Sensor Screw Tool For Easy Replacement Or Change Of Smart Sensors Under Normal Operating Conditions And To Prevent Premature Damage Of Any Of The Smart Sensors Under Normal Operating Conditions.Sensor Description:Barometric Sensor Should Sensor Range Shall Be 300 – 1100 Mbars With Accuracy Of ± 3 Mbar And Resolution 0.01 Mbar, Ambient Temperature: Temperature Range Should Be -20° To +70°C With Accuracy Of ±2°C And Resolution Of 0.1°C, Optical Dissolved Oxygen Sensor – Smart Sensorthe Optical Do Sensor Shall Comply With Epa-Approved Should Measurefrom 0 To 60 Mg / Lshould Have Accuracy Of 0.1Mg / L Of Reading From 20 To 60 Mg / L. Resolution: 0.01Mg / L, Conductivity Sensor Should Measure Range:0-350Ms / Cm T, Ds : 0-350Ppt, Salinity350psu, Accurcay Should Have ± 0.5% & Resolution , The Conductivity Sensor Should Have Report Measurements As: Actual Conductivity ( Μs / Cm, Ms / Cm ) , Specific Conductivity ( Μs / Cm, Ms / Cm ) , Salinity ( Psu, Ppt ) , Total Dissolved Solids ( Tds ) ( Ppt, Ppm ) , Resistivity ( Ohms-Cm ) , And Density ( G / Cm3 ) , Display: It Should Be Built-In Lcd Screen In Itself To Provide Clear, Instant Visual Indicators Of Overall Readiness, Sensor Status, Power Voltage, And Connectivity. Also Want Titanium Sensor Guard To Avoid Corrosion. Communicate Connections: Should Have The Ability To Communicate Wirelessly Through Bluetooth Wireless Technology. Also, It Should Be Able To Log Data Directly To Windows / Android / Mac Devices. The System Must Be Able To Record Live Reading When Connected To A Cable, Wireless Bluetooth Display And Based On Windows / Android / Apple Devices With The Application.Accuracy: ±0.1 Ph Unit.Minimum Orp Range: ±1400 Mv. Orp Sensor Accuracy:±5.0 Mv
Basic Detail
Tender No 4-102/3-2/2021/stores/ (ZSI-IOCL)/37
Bidding Type Tender
Location
City Kanchanvadi, Near Patel Colony no.9, Jamnagar
State Gujarat
Key Dates
Publish Date 04 Oct 2021
Submission Date 11 Oct 2021
Open Date 12 Oct 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
733db6fc-fa50-4c6e-824a-62ba07fa00b9.html
BOQ_685292.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 04, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 11, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 12, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

733db6fc-fa50-4c6e-824a-62ba07fa00b9.html

xls

BOQ_685292.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders