Housing Urban and Rular Development Government Departments Closing in 0 days TDR #29430576

Construction Of Building For Iccc At Sultanpur Lodhi District Kapurthala Construction Of Building For Iccc At Sultanpur Lodhi District Kapurthala

Issued by Government Departments · Sultanpurlodhi, Punjab
Tender Value
1.63 Crore
Estimated cost
Bid Submission
18 Oct 2021
0 days left
EMD
3.27 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Sultanpurlodhi → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Building For Iccc At Sultanpur Lodhi District Kapurthala Construction Of Building For Iccc At Sultanpur Lodhi District Kapurthala

BOQ

Name of Work: CONSTRUCTION OF BUILDING FOR ICCC AT SULTANPUR LODHI, DISTT KAPURTHALA (PUNJAB)
Sl. No. Item Description
1Construction of Main Building
2Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
3Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer\"s specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth- 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm.
4Cement concrete 1:5:10 with 40 mm gauge stone ballast.using concrete mixing volumetric type
5Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
6Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded.
7Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
8Lintels
9Ground Floor
10First Floor
11Extra rate for First Floor
12Shelves
13Ground Floor
14First Floor
15Extra rate for First Floor
16Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
17Slab
18Ground Floor
19First Floor
20Extra rate for First Floor
21Second Floor
22Extra rate for Second Floor
23Beams
24Ground Floor
25First Floor
26Extra rate for First Floor
27Columns
28Ground Floor
29First Floor
30Extra rate for First Floor
31Second Floor
32Extra rate for Second Floor
33Lift Walls
34Ground Floor
35First Floor
36Extra rate for First Floor
37Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
38Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
39Ground Floor
40First Floor
41Extra rate for First Floor
42Second Floor
43Extra rate for Second Floor
44Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
45Ground Floor
46First Floor
47Extra rate for First Floor
48Centring and shuttering for columns (Square or rectangular or poly gonal in plain)
49Ground Floor
50First Floor
51Extra rate for First Floor
52Second Floor
53Extra rate for Second Floor
54Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc
55Ground Floor
56First Floor
57Extra rate for First Floor
58Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
59Ground Floor
60First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
61First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..
62Ground Floor
63First Floor
64Extra rate for First Floor
65Second Floor
66Extra rate for Second Floor
67Third Floor
68Extra rate for Third Floor
69115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure.
70Ground Floor
71First Floor
72Extra rate for First Floor
7312.5mm thick cement plaster 1:5.
7420 mm thick cement plaster 1:5 in two coats work.
7512.5 mm thick cement plaster 1:4.
76Extra rate for Smooth Surface of Ceiling.
77Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS ClampU-PVC pipes (working pressure 4kgf. / sqcm)pipe 110 mm dia.
78Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm bend
79Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
80Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
81Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
82Providing and fixing in position gratings 150mm x 150mm for gully trap.PVC grating
83Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
84First Floor
85Extra rate for Second Floor
86Second Floor
87Extra rate for Second Floor
88Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
89Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
90For fixed portion & Chaukhat
91For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
92Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on one side.
93Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
94Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate andwith stainless steel cover plate etc. complete as per the direction of Engineer-in-charge.
95Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop .
96Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. 1 (size of door up to 700mm)
97Earth filling with good quality earth obtained from out side the plinthincluding compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compactingwithrammer complete as per specifications.
98Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres.
99Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
100Ground Floor
101Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
102First Floor
103Extra rate for First Floor
104Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :.
105Ground Floor
106First Floor
107Extra for First Floor
108Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing
109Ground Floor
110First Floor
111Extra for First Floor
112Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles havepigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm
113Ground Floor
114First Floor
115Extra for First Floor
116Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..
117Ground Floor
118First Floor
119Extra for First Floor
120Extra labour for projected nosing of stair case of any shape and design
121Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
122Precast chequered tiles of 20mm thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps on landings.
123Ground Floor
124Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
125Providing Polyester Powder coating 60to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work.
126Providing and fixing stair case railing made out of M.S. square bars 20mm x 20mm as vertical part 0.70 m high fixed with M.S. base plate of 40mm x 40mm x 6mm and flat iron 40mm x 6mm as hand rail complete in all respect.
127Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects.
128Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
129Ground Floor
130First Floor
131Extra rate for First Floor
132Second Floor
133Extra rate for Second Floor
134Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm
135Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm
136Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
137Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to getrequired finish
138Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade.
139Applying priming coat with metal primer on new steel or iron work including preparation of surface.
140Painting two or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work
141Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
142Construction ofPlinth protection complete as per drawing.
143Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
144Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type
145115 mm thick brick wall laid in cement mortar 1 :4 without reinforcement in foundation and plinth.
146Earth filling with good quality earth obtained from out side the plinthincluding compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compactingwithrammer complete as per specifications.
147Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling(Using mechanical mixer for mixing of material)
148Conglomerate floor 40mm thick cement concrete topping 1:2:4(Using mechanical mixer for mixing of material).
14912.5 mm thick cement plaster 1:5complete in all respect as per specifcation, drawing andto theentire satisfication of Engineer-In-Charge.
150Outer Infrastructure
151Construction of Boundary Wall With Grill
152Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
153Cement concrete 1:5:10 with 40 mm gauge stone ballast.using concrete mixing volumetric type
154First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
155Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
156Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
157Reinforced cement concrete M-20mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
158Centring and shuttering for Columns ( Square or Rectangular or ply gonal in plain)
159Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
160Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
161First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
16212.5 mm thick cement plaster 1:4.
163Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
164Iron grated doors, including pintle hinges and arrangements.
165Finishing walls with Premium Acrylic smooth exterior paintwith silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm
166Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
167Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
168Construction of Internal Concrete Roads, Pavements with Pavers & foot Path
169Earth filling with good quality earth obtained from out sideincluding compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compacting with road roller complete as per specifications.
170Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
171Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications
172Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufacturedby block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge.
173Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.
174Plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165mm and top width 115mm fixed in position including carriage to site of work complete as per technical clause 408 of MORT&H specifications
175Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
176Providing and Laying Out DoorPrecast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurrycontainingpigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
177Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
178Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
179Sub Work-1 Internal Water Supply, Sewerage, Sanitation
180Sub Head-1 Internal Sewerage System
181Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type A
182110mm o/d single socket SWR UPVC pipe lines laid complete
18375mm o/d single socket SWR UPVC pipe lines laid complete
184Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
185For 110mm i/d pipes
186Elbow 90 Degree (All side socketed)
187Coupler
188P Trap/Floor Trap 110mm x 110mm
189For 75mm i/d pipes
190Coupler
191Floor Trap 110mm x 75mm
192Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc.as per standard design minimumdepth of water should be 150 mm with a minimum seal 50mm.
193100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm
194Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
195Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal
196Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.
197uPVC Pipe 6 Kgf/cm250mm i/d
198Sub Head-2 Internal Water Supply System
199CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
200CPVC SDR 11 Pipe & fitting 16mm o/d
201SDR 11 CPVC pipes & fittings 20mm o/d
202CPVC SDR 11 Pipe & fitting 25mm o/d
203Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
204Through wall 11.43 cm thick
205Through wall 22.86 cm thick
206Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879in G.I. Pipe lines complete in all respect.
20715mm i/d G.I. Union
20820mm i/d G.I. Union
20925mm i/d G.I. Union
210Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.
21125mm i/d Brass Ball valves
212Sub Head - 3 Sanitary Installation
213Providing and fixing in position Chinaware Indian Orisa water closetsize 580 x 440 mm of approved make (to the approval of the Engineer-in-charge) consisting of10 ltr. PVC flushing cistern including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
214Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
215Providing and fixing jet spray with 2\"-6\" long PVC pipe.With PTMT nut
216Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
217Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tubeconnection 300 mm long complete.
218Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
219Size 49 cm dia (above counter round)
220Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
221Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
222Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm
223Providing and fixingin positiontowel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
224C.P. brass towel Rails size 15mm dia 610mm long
225Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x 375 mm with PTMT nut
226Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
227Providing and fixingin position C.P. brass soap dishof approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
228Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
229C.P. brass Bib cock long nose/ long body without flange
230C.P Brass bib cock foam flow without flange
231Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
232C.P.brass 15mm Angle valve without flange
233C.P.brass 15mm Concealed stop cock with flange
234Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
235Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long
236Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backingfixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on topcomplete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm)
237Providing and fixingin position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inletof approved make (to the approval of Engineer-in-charge) complete in all respect.
238Providing & fixing in position 15 mm i/d C.P brass wall mixerof approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. brass wall mixer without telephonic shower
239Providing and fixing in position premium range C.P. Brass Fittings and accessoriesof approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass Accessories:
240C.P. brass toilet roll holder with flap
241Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs
242Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect.
243Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks
244Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod andPlastic Ball
245Brass Ball Cock with rod andPlastic Ball 32mm i/d
246Brass Ball Cock with rod andPlastic Ball 25mm i/d
247Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
248G.I. tank nipple 25mmi/d
249Construction of Plateform complete as per specification& as desired by Enginer-in-charge
250Sub Head-4 Flooring and Wall Tile
251Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
252Ground Floor
253Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
254First Floor
255Extra rate for First Floor
256Providing and laying Rectified Porcelainfloor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Fine sand) for new flooring complete
257Ground Floor
258First Floor
259Extra Rate for First Floor
260Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
261Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
262Ground Floor
263First Floor
264Extra Rate for First Floor
265Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..
266Ground Floor
267First Floor
268Extra Rate for First Floor
269Extra labour for projected nosing of stair case of any shape and design
270Sub Head -5 Water Coller & Air Conditioning
271Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
272Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
273Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer
274Supply & Erection of automatic voltage stabilizer for storage type water cooler, Wall mounted, Heavy duty, copper wounded with volt meter etc. along with 3 core cord of suitable length and 3 pin power shoe including erection, connection & testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. Make... V – Guard or its equivalent.
275Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to theapproval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
276Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Make:- Toshiba, Mitsubishi Electric, Daikin, O\" General, Hitachiwith 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipewithin building and installing charges complete in all respects
277Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Star Make:- Toshiba, Mitsubishi Electric, Daikin, O\" General, Hitachi with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipewithin building and installing charges complete in all respects
278Providing laying hard soft copper concealing of copper pipes of dia 12.7mmod (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.
279Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.uPVC Pipe 6 Kgf/cm240mm i/d
280Electrical services
281Providing Internal Electrical Installations
282RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (withfinishing the surface):-Make :- PVC Pipe = Anchor, Polycab, Norpack, Adarh Plast, Diplast. PVC Copper Wires =Polycab, Tamra,KEI,Ecko, RR kabel, Rallison, Havell\"s, V-Guard, CMI, HPL.Accessories:-North-West(Nova), Havell\"s (Crab Tree), Legrand (Myrius), Hager
283Wiring fan point with sheet metal fan box
284Wiring light point
285Wiring call-bell point
286Wiring 3 pin 6 Amp. wall socket point
287Wiring 3 Pin 6 Amp. Plug control comprising wall socket point
288Wiring 3 pin 16/20 amp. power plug control point
289Wiring light point with double control switches.
290PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Make:-Polycab, Tamra,KEI,Ecko, RR kabel, Rallison, Havell\"s, V-Guard, CMI, HPL.
291Overall size 1sq.mm (Un-sheathed)
292Overall size 2.5sq.mm (Un-sheathed)
293Overall size 4sq.mm (Un-sheathed)
294Overall size 10sq.mm (Un-sheathed)
295Overall size 16sq.mm (Un-sheathed)
296Overall size 25sq.mm (Un-sheathed)
297XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-POLYCAB,RR KABEL,RALLISON,HAVELLS,.
298Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
299PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Make:- Anchor, Polycab, Norpack, Adarh Plast, Diplast.
300Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
301Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed
302Supply and erection of PVC flexible pipe complete without compression glands,locking arrangement, check-nuts as required:-
303PVC flexible pipe 40mm dia.
304Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:-
305PVC compression Socket gland 40mm dia.
306HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
307Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan.
308COPPER EARTHING (Upto 14 metre in Length):-iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
309Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
310Additional Length 20mm x 3mm thick Copper Tape .
311SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets, power switch and sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including connections and petty material etc.Make :-Anchor / Fine
3126/10amp. One Way Modular Switch (One Module)
3136amp. 2/3 Universal Modular Shuttered Socket (two Module)
314Modular Telephone Socket (RJ-11) One Module
315Modular RJ-45 Modem Jack for Computer (One Module)
316Supply and erection of Modular Cover Frame (Complete set) on the existing metal box including fixing and connection of existing switches and sockets and other petty material etc:-
317Modular Cover Frame One or Two Module
318Modular Cover Frame Six Module
319Modular Cover Frame Eight Module
320Supply and erection ofPVC Channel (uPVC Trunking) with cover of various sizes (On Surface) on wall, Flat angle, internal & external angle, Flat Tee, End cap and mounting boxes including the cost of joint cover, fixing and other petty material etc.:-
321PVC Channel (uPVC Trunking) 100mm x 50mm
322End Cap 100mm x 50mm
323Mounting Box 1-3 Module
324Mounting Box 4-5 Module
325Mounting Box 8 Module
326MINIATURE CIRCUIT BREAKERS:-Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuitcurrent fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- GROUP-A: Siemens (Beta Guard), Legrand (Lexic) , Schneider (Acti-9), L&T (Exora),Hager
327MCB Single Pole 6-32amp. (10kA, Curve-C)
328MCB Double Pole 6-32amp. (10kA, Curve-C)
329MCB Four Pole 40amp. (10kA, Curve-C)
330MCB Four Pole 50, 63amp. (10kA, Curve-C)
331SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-Make:-Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) ,Schneider (Acti-9), L&T (EXORA), HAGER
332TP&N Horizontal Double Door Distribution Board 6 way each.
333Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
334Cable End Box for TPN 6 Way
335ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure):-Supply and erection ofOn Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-Make:- HPL / L&T / C&S
336On Load Change Over Switch Four Pole 100amp., 415volts (With Sheet Enclosure)
337LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS):-Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work .
338Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB\"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:-digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc.
339Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:-
340LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB\"s40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm)
341LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB\"s40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm)
342MOULDED CASE CIRCUIT BREAKERS:Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevantPWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc Make: L&T, ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)):Hager,Legrand
343MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting
344MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting
345MCCB Four Pole 160amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting
346MCCB Four Pole 200amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting
347DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level includingexcavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Make :-TeleRex,Gemni,CPE,Dura Line
348Double walled corrugated (DWC) HDPE pipe120/103.5mm (outer/ inner dia.)
349Supply and erection of LED batten 40watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make:- BAJAJCat No. BCLAB40W ,JAQUAR CAT NO. LGLZ01X040XC, PHILLIPS Cat no:-BN108C LED 40 S PSU CDL WH , CROMPTON:-LDL-40-CDL,C&S:-LTTB4F40WLED /W,HAVELLS:-STOUTPLUS1200BS40WLED840SPCWH
350Supply and erection of LED batten 20watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make: Jaquar LGLZ01X020XC / Philips BN02IC LED20S PSU CW GR/ Havells ENDURALINEARNEOBS20WLED830SPCWH,Crompton:-LDL-20-CDL, C&S:-LTTB4F20WLED/W
351Supply and erection of Ceiling Fan 1200mm , 48\" with double ball bearing including flexible wire & petty material etc. for connections and testing . complete in all respects as appd. and desired by the Engineer in-charge at site. Makes:- Crompton Entrust 50- Opel White/ Havell\"s ES-50/ ANCHOR:-Panta Turbo Star code 13671WH / V-Guard Coolgate 48, Halonix:- Zephyr(ISI With )
352Supply and erection of Heavy duty Exhust Fans 300mm 900RPM with louver shutter, double ball bearinglonger life including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. Make:-Crompton EXHD300-6-1 /Havells Turbo Force SP / Anchor Anmol Heavy Duty .
353Supply and fixing of triple compartment under floor trunking size 225mmx38mmmade out of 1.6mm thick pregalvanised sheetcomplete with all accessories and fixing accessories as per site requirement all as required & specified. Make:-LEGRAND /MK/ OBO
354Supply and fixing of coupler/joint sleevfortriple compartment under floor trunking size 225mmx38mmwith all accessories and fixing accessories as per site requirement all as required & specified. Make:-LEGRAND /MK/ OBO
355Supply and fixing of Junction Box 225*225mm with flyover fortriple compartment under floor trunking size 225mmx38mmwith all accessories and fixing accessories as per site requirement all as required & specified. Make:-LEGRAND /MK/ OBO
356Supply and fixing of Pop-up type flush-mounting boxes (6modules) with matt aluminium finish, Soft opening cover with damper and push & slide locking system, all fixing accessories as per site requirement all as required & specified. Make:-LEGRAND /MK/
357Providing EPBAX System
358Supply, Installation, Testing & Commissioning of the Switching system of the EPABX should be designed with IP at the core allowing fully distributed IP solutions across data networks in 19” Rack Mountable,7 universal slots in single Node and should support card Analog Extension Card , Digital Extension Card , for the respective addition / expansion. Analog & Digital extensions can be increased in the steps of 8, 16 & 32 Ports. Analog Trunks , PRI, BRI Trunks, E1 & SIP Trunks . Single card/module should support 2 or more PRIs, It should support 100% IP or 100 % TDM or a hybrid of IP/TDM technologies.1.2. The EPBAX configured for 04 trunk lines, 32 analogue extension card and 02 Sip Extension. The system should support IP Communication Devices (wired and wireless) e.g. IP Phones (Hard and Soft phones), Mobile IP Phones, multimedia PCs, SIP phones, Video phones (Hard & soft), etc.1.3. The system should also support Legacy TDM communication devices (Digital and analog 2 Wire telephone instruments with or without caller-id (Both FSK and DTMF), Fax, modems, ISDN phones etc. 1.6. The proposed system should support direct SIP integration with Microsoft Lync 2013 including following. Vendor should provide proper document towards certification with Microsoft Lync 2013 integration.1.16. The system should support at least 228 analog extensions in a single node and up to 600 analog Extensions in multiples nodes, at least 400 Digital Phones in a single node and 600 digital phones in multiple node, support at least 600 SIP extensions in a single node, Support 600 DECT/SIP DECT phones. support at least 224 DECT base stations and over 4000 SIP-DECT Base stations. should support minimum 56 Analog Trunks ,56 ISDN BRI trunks,14 PRI Trunks.Fax over IP with T.38 Interface and should support minimum 140 channels.240 SIP access channels.1.26. The system should have in-built Auto Attendant and Voice Mail system. complete in all respects as approved and desired by the Engineer in-charge at site. Make : Tadiran/ Aastra/ Nortel/ Ericsson/Mitel/Cisco
359Supply and Erection ofIP base Operator-cum-maintenance console with Small Backlit Display, Direct Dialling Keys, Duplex Speaker Phone, Touch sense keysincluding all features listed in Product Boucher complete in all respect as desired by the engineer in charge at site. Make:Tadiran/ Aastra/Nortel/Ericsson/Mitel/Cisco
360Supply & erection of Basic Phone with CLIP and display completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Beetel Model M51/C51/P-Tel/ Binatone/PANASONIC/Siemens.
361Supply Installation Testing and commissioning of IP- SIP Featured Phones, with callers logs, redial lists, and 3 programmable keys, Transfer, Callers List, Hold, Redial, Goodbye, Options, 2 volume keys, Mute (with LED) and Speaker (with LED) as well as a 4-way navigation with Select/OK key, Hearing aid compatible (HAC) handset Full-duplex quality speakerphone Wideband handset and speaker phone codecs: G.711 µ-law / A-law, G.729, G.722, AMR*, AMR-WB(G.722.2)*, G.726, iLBC, BV16, BV32, L16 Echo cancellation, Comfort noise utilization, Packet loss concealment, Voice Quality Metrics, including MOS,Headset Mode support ,complete as per specification and as desired by EIC,PoE Class 1,Level\"\"V\"\" energy efficiency rated power adapters available,Dual 10/100 Mbps Ethernet portsCompatible with EPABX System Without Addition Programming completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Tadiran/Aastra/Nortel/Ericsson/Mitel.
362Supply and erection 50 Pairs MDFwith Krone Modules & Lockable Box complete in all respect as desired by the engineer in charge at site. Make: Krone/M-Tel/Reliance/ A-Tel/Airtel
363Supply & Erection of 10 PairMDF with Original Krone Modulelock & keyfacility completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Krone/M-Tel/Reliance/ A-Tel/Airtel
364Supply & Erection of 20 PairMDF with Original Krone Modulelock & keyfacility completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Krone/M-Tel/Reliance/ A-Tel/Airtel
365Supply & erection of02 Pair 0.5mm PVC Dual sheathed Telephone Cable as per ITD Specification 113-B With Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ HIMCOM/Shalimar.
366Supply & erection of10 Pair 0.5mm PVC Dual sheathed Telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar.
367Supply & erection of20 Pair 0.5mm PVC Dual sheathed Telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar.
368Supply & erection of50 Pair 0.5mm PVC Dual sheathed Telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar.
369Supply & erection of 1KVA Online LIT sine wave UPS/ Power Plant with in built SMF batteries having 30 Minutes backup time complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.Make-APC/NUMERIC/ UNILINE/EATON/AQUA POWER.
370PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Make:- Anchor, Polycab, Norpack, Adarh Plast, Diplast.
371Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
372DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level includingexcavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Make :-TeleRex,Gemni,CPE,Dura Line
373Double walled corrugated (DWC) HDPE pipe50/38mm (outer/ inner dia.)

AI Tender Summary

OUR REF NO 29430576
AUTHORITY Government Departments
TENDER VALUE 1.63 Crore
LAST DATE 18-10-2021
Authority
Authority Name Public Works Department
Work Description Construction Of Building For Iccc At Sultanpur Lodhi District Kapurthala Construction Of Building For Iccc At Sultanpur Lodhi District Kapurthala
Basic Detail
Tender No 5 dated 7.9.2021
Bidding Type Tender
Location
City Sultanpurlodhi
State Punjab
Key Dates
Publish Date 04 Oct 2021
Submission Date 18 Oct 2021
Open Date 18 Oct 2021
Finance
Tender Value 1.63 Crore
Tender Fee 10000
EMD 3.27 Lakhs
Exemption Not Available
Document List
21d823a2-d7a1-438b-8a52-da2b83913042.html
BOQ_152490.xls
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 04, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 18, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 18, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

21d823a2-d7a1-438b-8a52-da2b83913042.html

xls

BOQ_152490.xls

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders