Tender Notification For Scheme No: Mn21el2045 “E/O 821 Houses At Bakkarwala In Brpl” Providing and Fixing of Danger plate with clamps. Trimming of any no. of branches of any size of any type of tree as to keep them away at least 2.00 mtr at the time of trimming in such a way that they do not fall on the GI/ACC shed, live transformer, electric/telephone wire by any means Use, axe, saw, ro Labour charges for digging of the trench of the required size including the backfilling with the excavated earth and ramming the same and disposing the surplus excavated material all complete. Payment shall be released as per actual depth excavated or as Laying of under- ground HT. cable in trench ,docketing with bricks & sand as per BSES specifications, refilling the trench and ramming the surface & removal of malba if any, including supply of IInd class bricks and sand (Sand cushion min 75mm below and 7 Laying of HT/LT cable of following size in S/ Stn. Trench.above 150 sq.mm. Transportation of Electrical equipments or any any kind of materials from store to site or from site to site including laoding and unloading at both ends by using T & P such as Tripod/cranes -> By Full body truck load (9T capacity). Note:- Above item wil Transportation of materiual by hand-cart Supply of HDPE pipes as per IS 4984,PN 4 class PE 63 - 140mm dia. Crossing of roads by trench-less technology by laying of HDPE pipe excluding supply of pipe .Laying by HDD Machine Moling.Drilling and laying. 110/140mm dia. Earthing with 40mmX2.5mt.,GI pipe of B class with Masonary earth pit enclosure on top covered having locking watering arrangement with funnel I/C provision of salt charcoal as per IS 3043. (Resistance should be less than 1 ohm) Salt,charcoal, masonary ma Labour charges for digging of the trench of the required size including the backfilling with the excavated earth and ramming the same and disposing the surplus excavated material all complete. Payment shall be released as per actual depth excavated or as Digging of joints pits as required, docketing with bricks and sand of the joint & refilling with loose earth and ramming the surface including removal malba. Brick and sand shall be supplied by the contractor Laying of under- ground HT. cable in trench ,docketing with bricks & sand as per BSES specifications, refilling the trench and ramming the surface & removal of malba if any, including supply of IInd class bricks and sand (Sand cushion min 75mm below and 7 Laying of under- ground LT cable in trench ,docketing with bricks & sand as per BSES specifications, refilling the trench and ramming the surface & removal of malba if any, including supply of IInd class bricks and sand (Sand cushion min 65mm below and 75 Laying of HT/LT cable of following size in S/ Stn. Trench.above 150 sq.mm. Mounting of HT cables on pole,after passing through suitable size of GI pipe proper Clamping and proving and fixing wooden bush alongwith clamping of end box. of size 3 x 150 sqmm and above /pole.(The length of cable to be mounted on pole should be exclu High Voltage test of 11KV 3x300/ 400 sq.mm cable - Testing Equipment to be provided by the contractor. Laying and connecting of 11KV cable of size 3x150 sq. mm. from HT switch gear to the transformer and LT single core cable of size 630 sq. mm. from TR to LT board including fixing the same by means of proper wooden cleats etc. required (The work include Installation , testing and commissiong of 11/0.433 KV distribution Transformer of following sizes on existing plinth including grouting of frames required on HT & LT side for cables as per BSES Design & practice. 630 KVA Transformer any type. Fixing of fire extinguishers/ bucket by means of proper hooks clamps etc. as required including grouting and painting of hooks/clamps. Mounting , testing and commissiong of following accessories on the existing structure of P/M S/Stn or I/D s/stns . By means of suitable nut, bolts & clamps etc. including mounting on necessary frames electrically interconnecting with each other after Crim Mounting , testing and commissiong of following accessories on the existing structure of P/M S/Stn or I/D s/stns. By means of suitable nut, bolts & clamps etc. including mounting on necessary frames electrically interconnecting with each other after Crimp Making connections at where ever required (feeder pillars/service pillars/ LT panel etc.) with following size of socket including crimping of socket and complete armouring: AL 150 sqmm sockets (Sockets will be supplied by BSES). Painting of nomenclature of size(s) as reqd. on FP/Service Pillar / LT Panel / HT Panel and LT ACBs etc. including supply of paint.rates are per alphabat Making connections at where ever required (feeder pillars/service pillars/ LT panel etc.) with following size of socket including crimping of socket and complete armouring: AL 300 sqmm sockets (Sockets will be supplied by BSES) Making connections at where ever required (feeder pillars/service pillars/ LT panel etc.) with following size of socket including crimping of socket and complete armouring: AL 630 sqmm sockets (Sockets will be supplied by BSES) Supply & Installation of fire buckets filled with sand, including fabrication of frame/stand of suitable size, canopey, grouting on surfce or wall, painting of frame including necessary hardware and consumables. 4 bucket stand Making Cable End termination. Note: End Termination kit will be provided by BSES as free supply. Making Straight through joint. Note: St.Th.joint kit will be provided by BSES as free supply. Transportation of Electrical equipments or any any kind of materials from store to site or from site to site including laoding and unloading at both ends by manually -> By Full body truck load (9T capacity). Note:- Above item will be selected ensuring op Transportation of Electrical equipments or any any kind of materials from store to site or from site to site including laoding and unloading at both ends by using T & P such as Tripod/cranes -> By Full body truck load (9T capacity). Note:- Above item wil Transportation of materiual by hand-cart Transportation of empty cable drum from site to designated store anywhere in Delhi.For Steel Drum Plinthing and erection of Service Pillars / Feeder Pillars as per BSES design including supply of bricks, cement, badarpur, jamuna sand etc. Feeder Pillar RMU installation 3- Function RMU installation 4- Function. Testing and commissioning comprising of Hi-pot test, primary injection, IR & mV Drop test for 3-Function RMU. Testing and commissioning comprising of Hi-pot test, primary injection, IR & mV Drop test for 4-Function RMU. Casting of civil foundation for each 3 Way-RMU. It includes cement, sand, ballast (rodi)and labour. Casting of civil foundation for each 4-way RMU. It includes cement, sand, ballast (rodi)and labour. Extra civil work for step-making (required for smooth operation/maintenance of RMUs)if the RMU is to be installed more than 300mm height from Ground Level. Supply & Erection of MS Frame for 3-Way RMUs. Supply & Erection of MS Frame for 4-Way RMUs. Supply and fixing of wire mesh fencing 2.5 mtr height with gate frame of 3 mtr x 2.5 mtr with complete material including painting eg angle,chain link,wire mesh and civil material etc complete as per specification & drawing of BSES.Angle iron size 50x50x6 Labour charges for digging of the trench of the required size including the backfilling with the excavated earth and ramming the same and disposing the surplus excavated material all complete. Payment shall be released as per actual depth excavated or as Laying of under- ground LT cable in trench ,docketing with bricks & sand as per BSES specifications, refilling the trench and ramming the surface & removal of malba if any, including supply of IInd class bricks and sand (Sand cushion min 65mm below and 75 Transportation of Electrical equipments or any any kind of materials from store to site or from site to site including laoding and unloading at both ends by using T & P such as Tripod/cranes -> By Full body truck load (9T capacity). Note:- Above item wil Transportation of materiual by hand-cart Erection of electrical equipment Including supply of T & P, all consumable items such as welding rods, hacksaw blades etc and minor modification in support structure for fixing as required.For 11 kV, Indoor switchgear, Outgoing panel Laying of MS flat in the excavatd trench including risers, equipment earthing, overlapping of MS flat at the joints by twice of its width and welding of over lapping and cross joints including supply of electrodes, red oxide/bitumin compound , paint et Erection of double compression gland including termination For 2CX10 sqmm, Cu Providing and Fixing of Danger plates. Providing and Fixing of number plates . Providing and Fixing of Phase plates . Providing and Fixing of circuit plates . Digging of earth pit upto depth of 10 ft. inrocky/ semi rocky as per feasibility at site of embedding 600 x600mm earth plate with M.S Flate 50 x8 mm running the same through 3/4 dia G.I. grouting pipe. Earth Plate to be covered by charcoal 200kg. And 10 Supply of Glands 4X25MM Supply of Glands 10X2.5MM Supply of Glands 5X 2.5MM Supply of Galvanized Nut & Bolts Supply of Copper Bus Bar of various size Transportation of electrical equipment I.e.CB,CT,PT,ISOLATORS,LA,CABLE DRUMS etc. from store/any site in Delhi to site of work in Delhi inclding loading and unloading at both ends by using T & P such as Tripod/cranes etc.(Considering max lead of 50KM) a. AC/DC Connections. (11 KV VCB) b. All interpanel wiring if PT and Interlocks. c. Testing of all the Indications of CRP . d. Testing of Breaker Operation e. Testing of Relays with Secondary Injection Testing of Earthfault and Overcurrent Relays(50 & 51N) (11 KV VCB) i Testing of IDMT Char. ii Testing of DMT Feature. iii Testing of Direction Feature (Optional) iv Testing of Programmable LEDs v Testing of I/Os Testing of CTs with Primary Injection Method. (11 KV VCB) i. Ratio Test by Primary Injection. ii. Polarity Test. iii. Knee Point Voltage iv. Connection Verfication of metering and Protection Circuit Watch & Ward Charges. Transportation of electrical equipment from store/any site in Delhi to site of work in Delhi inclding loading and unloading at both ends manually.(Considering max lead of 50KM) Supply of Rubber Mat 1000 mm wide (5 mtr. Length) Erection of electrical equipment Including supply of T & P, all consumable items such as welding rods, hacksaw blades etc and minor modification in support structure for fixing as required.For 9KV LA Erection of electrical equipment Including supply of T & P, all consumable items such as welding rods, hacksaw blades etc and minor modification in support structure for fixing as required.For 11 kV Indoor switchgear, Incomer panel & bus coupler Erection of electrical equipment Including supply of T & P, all consumable items such as welding rods, hacksaw blades etc and minor modification in support structure for fixing as required.For 33 kV/11kv Indoor switchgear, Bus trunking panel with single S/I/T/C of 11 KV Bus-Trunking Chamber suitable for joining the H.T. panel i/c Fabrication of M.S Steel chamber with M.S Steel sheet and Angle Frame,its painting with one coat of primer and two coats of required colour ISI marked paint to match the colour Cable laying of 6.35/11KV,XLPE,stranded Aluminium 3CX300sq. mm Armoured,FRLS outer PVC sheath Making Cable End termination. Note: End Termination kit will be provided by BSES as free supply. Cable laying of 6.35/11KV,XLPE,stranded Aluminium 1CX1000sq. mm Armoured,FRLS outer PVC sheath