Health and Family Welfare Government Departments Closing in 0 days TDR #29399746

Design, Supply, Installation, Commissioning, Operation & Maintenance Of Medical Gas Pipeline System ( Mgps ) At Belda Super Speciality Hospital Of West Bengal For 5 Years

Issued by Government Departments · Belda SSH at Paschim Medinipore District, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
01 Nov 2021
0 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Belda SSH at Paschim Medinipore District → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Design, Supply, Installation, Commissioning, Operation & Maintenance Of Medical Gas Pipeline System ( Mgps ) At Belda Super Speciality Hospital Of West Bengal For 5 Years

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 25-Oct-2021 Corrigendum-I Date 01-Nov-2021

BOQ

Name of Work: Design, Supply, Installation, Commissioning, Operation & Maintenance of Medical Gas Pipeline System (MGPS) at Belda Super Speciality Hospital of West Bengal for 5 years
Sl. No. Item Description
1Design, Supply, Installation, Testing, Commissioning of OXYGEN SYSTEM
22 x 10 size Main manifold complete with middle frame with chain for individual cylinder along with Tail Pipe and Non Return Valve for every cylinder and Isolation Valve, Safety Valve, etc.as required for the complete manifold system as per standards
32 x 5 size emergency manifold complete with middle frame with chain for individual cylinder along with Tail Pipe and Non Return Valve for every cylinder and Isolation Valve, Safety Valve, etc.as required for the complete manifold system as per standards
4Fully Automatic control panel Indigenousfor Oxygen Having a constant delivery flow capacity of1500 lpm to 2000 lpm or above at 4.2 bar pressure as perStandards
5Surface/panel/pendant mounted front loading double lock Oxygen outlets with matching Adapters (BS type) as per standards
6Oxygen Flowmeter & Humidifier Bottle with matching adapters: Back Pressure Compensated Flow meter within a range of 0-15 LPM where 0-5 LPM should be with expanded scale. Humidifier bottle should be made of unbreakable polycarbonate materials and autoclavable at 121 degree Centigrade (to be supplied along with required low pressure tubing and face mask) as per standards
7H.P. tubing having anti static core white color5mtrs with kit conversion for Oxygen
8Design, Supply, Installation, Testing, Commissioning of NITROUS OXIDE SYSTEM
92 x 2 size manifold (Primary & Secondary supply) complete with middle frame with chain for individual cylinder along with Non Return Valves for every cylinder, Safety Valve, etc. as required for the complete manifold system as per standards.
10Fully Automatic control panel Indigenousfor Nitrous Oxide Having a constant delivery flow capacity of1000 lpm or above at 4.2 bar pressure as perStandards
112 cylinder Emergency Nitrous oxide arrangement using a high flowdouble stage Regulator withgauges complete with middle frame with chain for individual cylinder along with Non Return Valves for every cylinder as per standards
12Surface/panel/pendant mounted front loading double lock Nitrous Oxide outlets with matching Adapters (BS type) as per standards
13H.P. tubing having antistatic core Blue color 5 mtrs. with Kit conversion for Nitrous Oxideas per ISO Standards
14Design, Supply, Installation, Testing, Commissioning of COMPRESSED AIR SYSTEM
15Compressed Air System complete with 3 nos. of non-lubricated, Reciprocating each of 15 HP Motor with 57 cfm capacity at 8.5Kg/cm2 pressure with Isolation Valve for each compressor, 2 nos. Air dryer with by-pass valve arrangement, Duplex Pressure Reducing Unit each for Air 4 bar & 7 Bar valve arrangement Flexible High pressure SS Hose for each compressor NRV for each compressor, 1 no. Air Receiver of 1500 litre capacity with Safety Valve and interconnecting pipelines, Pressure Gauge with Valve Arrangement in the Air Receiver Valve – Upstream of Air Receiver Automatic Drain Arrangement for air receivers Air Compressor By pass line Pressure Gauge with Valve arrangement in Main line Isolation Valve in the main line
16Supply, Installation, Testing and commissioning of 4-stage air filtration system (suitable for 15 HP Compressor) as per ISO 8573.1.
17Surface/panel/pendant mounted front loading double lock Medical Air-4 bar Outlets with matching Adapters (BS type) as per standards
18Surface/panel/pendant mounted front loading double lock Surgical Air-7 bar Outlets with matching Adapters (BS type) as per standards
19HP colour coded black Tubing having anti static core as per ISO Standards
20Design, Supply, Installation, Testing, Commissioning of VACUUM SYSTEM
21Vacuum Central System Complete with 3 nos. Vacuum Pumps each having 149 cfm PD withFilter, interconnecting pipes, NRV, auto switch gear assy., exhaust silencer And Receiver – 1 No. 2000 liters, 2 nos. Bactria Filters, oil trap filter, etc. NRV for each Vacuum Pump Isolation Valve for each Vacuum Pump Valve - Upstream of Vacuum Receiver Vacuum Drain valve with flask arrangement Filters for each vacuum pump Silencer for each vacuum pump.
22Surface/panel/pendant mounted front loading double lock Vacuum Outlets (BS Type) with matching Adapters
23Ward vacuum Unit : It shall include vacuum regulator along with 0-760 mm of Hg vacuum gauge,600 ml capacity reusable poly carbonatecollection bottle with overflow safety trap andautoclavable at 121 degree Centigrade with plastic slide wall mounted type (to be supplied along with required low pressure tubing with catheter).
24Theatre Vacuum Unit: It shall be trolley mounted. The unit shall include one regulator along with 0-760 mm of Hg vacuum gauge mounted on the trolley stand, having two reusable collection bottles each of 2000 ml capacity and made of unbreakable polycarbonate materials, autoclavable at 121° Centigrade, having over flow safety trap, mounted on the base of trolley unit made of aluminium along with castor wheels and connected with regulator & low pressure tube inter-connections (along with required low pressure tubing with catheter).
25Low Pressure Tubing having anti static core as per ISO Standards
26High Pressure Tubing having anti static core as per ISO Standards
27Supply, Installation, Testing and commissioning of Combined Electrical Control Panel for VacuumSystem (149 cfm each) & Compressed Air system (15HP each) with Triplex/Triplex/ Cascading/ Sequencing facilities and complete with plant Room wiring .
28Design, Supply, Installation, Testing, Commissioning of Distribution Copper Pipe
2912 mm OD x 0.7 mm thick copper pipe
3015 mm OD x 0.9 mm thick copper pipe
3122 mm OD x 0.9 mm thick copper pipe
3228 mm OD x 0.9 mm thick copper pipe
3342 mm OD x 1.2 mm thick copper pipe
3454 mm OD x 1.2 mm thick copper pipe
35Design, Supply, Installation, Testing, Commissioning of Isolation Valve
36Isolation Valve 15 mm
37Isolation Valve 22 mm
38Isolation Valve 28 mm
39Isolation Valve 42 mm
40Isolation Valve 54 mm
41Design, Supply, Installation, Testing, Commissioning of Area Valve Service Unit
422gas valve box configuration with size 15 O2, 22 VAC
433 gas valve box configuration with size 15 O2, 15 MA4, 22 VAC
444 gas valve box configuration with size 15 O2, 15 N2O, 15 MA4, 22 VAC
455 gas valve box configuration with size 15 O2, 15 N2O, 15 MA4, 15 SA7, 22 VAC
46Design, Supply, Installation, Testing, Commissioning of Medical Gas Digital Area Alarm System as perstandards
472 service alarm configuration for O2 and VAC
483service alarm configuration for O2,MA4,VAC
494 service alarm configuration for O2, N2O, MA4, VAC
505 service alarm configuration for O2, N2O, MA4, SA7, VAC
51Design, Supply, Installation, Testing, Commissioning of Ceiling Pendants
52Ceiling Anesthetist Pendants for OT: Supply, Installation, Testing and commissioning of Single Arm Ceiling Pendant with8 nos. of Gas & Vacuum Outlets (2-Oxygen, 2-N2O, 2-Air 4 bar, 2-Vac)
53Ceiling Surgeon Pendants for OT: Supply, Installation, Testing and commissioning of Single Arm Ceiling Pendant with8 nos. of Gas & Vacuum Outlets (2-Oxygen, 1-N2O, 1-Air 4 bar, 2-Air 7 bar, 2-Vac)
54Testing, Commissioning of Distribution Copper Pipe
5512 mm OD x 0.7 mm thick copper pipe
5615 mm OD x 0.9 mm thick copper pipe
5722 mm OD x 0.9 mm thick copper pipe
5828 mm OD x 0.9 mm thick copper pipe
5942 mm OD x 1.2 mm thick copper pipe
60Testing, Commissioning of Isolation Valve
61Isolation Valve 15 mm
62Isolation Valve 22 mm
63Isolation Valve 28 mm
64Testing, Commissioning of Area Valve Service Unit
652gas valve box configuration with size 15 O2, 22 VAC
663 gas valve box configuration with size 15 O2, 15 MA4, 22 VAC
675 gas valve box configuration with size 15 O2, 15 N2O, 15 MA4, 15 SA7, 22 VAC
68Installation, Testing, Commissioning of Distribution Copper Pipe
6912 mm OD x 0.7 mm thick copper pipe
7015 mm OD x 0.9 mm thick copper pipe
7122 mm OD x 0.9 mm thick copper pipe
7228 mm OD x 0.9 mm thick copper pipe
7342 mm OD x 1.2 mm thick copper pipe
7454 mm OD x 1.2 mm thick copper pipe
75Installation, Testing, Commissioning of Isolation Valve
76Isolation Valve 15 mm
77Isolation Valve 22 mm
78Isolation Valve 28 mm
79Isolation Valve 42 mm
80Isolation Valve 54 mm
81Installation, Testing, Commissioning of Area Valve Service Unit
822gas valve box configuration with size 15 O2, 22 VAC
833 gas valve box configuration with size 15 O2, 15 MA4, 22 VAC
844 gas valve box configuration with size 15 O2, 15 N2O, 15 MA4, 22 VAC
855 gas valve box configuration with size 15 O2, 15 N2O, 15 MA4, 15 SA7, 22 VAC
86Installation, Testing, Commissioning of Medical Gas Digital Area Alarm System as perstandards
872 service alarm configuration for O2 and VAC
883service alarm configuration for O2,MA4,VAC
894 service alarm configuration for O2, N2O, MA4, VAC
905 service alarm configuration for O2, N2O, MA4, SA7, VAC
91Operation & Comprehensive Maintenance for entire MGPS charges
92Operation & Comprehensive Maintenance charges for the 1st Year
93O&M charges for Year 2
94O&M charges for Year 3
95O&M charges for Year 4
96O&M charges for Year 5

AI Tender Summary

OUR REF NO 29399746
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 01-11-2021
Authority
Authority Name West Bengal Medical Services Corporation Limited
Work Description Design, Supply, Installation, Commissioning, Operation & Maintenance Of Medical Gas Pipeline System ( Mgps ) At Belda Super Speciality Hospital Of West Bengal For 5 Years
Basic Detail
Tender No WBMSCL/NIT-325/2021, Dated -24.09.2021
Bidding Type Tender
Location
City Belda SSH at Paschim Medinipore District
State West Bengal
Key Dates
Publish Date 25 Oct 2021
Submission Date 01 Nov 2021
Open Date 02 Nov 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 2 Lakhs
Exemption Not Available
Document List
Cdate325.pdf
eProcurement System of Government of West Bengal.pdf
5fca3b95-db6c-4d45-b223-78e94d801aea.html
BOQ_663782.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 25, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 01, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 01, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 02, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Cdate325.pdf

pdf

eProcurement System of Government of West Bengal.pdf

html

5fca3b95-db6c-4d45-b223-78e94d801aea.html

xls

BOQ_663782.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders