| 1 | Material and labor for replacement of unserviceablecut sealed compressor of window type/split type ACs 1.5TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, includinggas charging complete and testing after completion of work at MES store yard for satisfactory functioningNOTE:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions(ii)The new compressor unit will be purchased fromauthorized dealers only as perexisting make and model |
| 2 | Material and labor for replacement of unserviceablecut sealed compressor of split type ACs2TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning-:NOTE:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii)The new compressor unit will be purchased fromauthorized dealers only as perexisting make and model |
| 3 | Material and labor for replacement of unserviceablecut sealed compressor of split typeInvertors ACs1.5/2TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii)The new compressor unit will be purchased fromauthorized dealers only as perexisting make and model |
| 4 | Material and laborfor rewinding of blower motor ofSpeed 900 RPM of window/Split Air conditioner of cap. 1.5/ 2tonany make with super enameled copper conductorincluding replacement of worn out bushes ,Shaft and capacitor etchant testing complete all as specified and directed |
| 5 | Material and labourfor replacement of Swing motor for indoor unit of window/Split Air conditioner of cap 1.5/2 TR and complete all as specified and directed |
| 6 | Material and labourfor replacement of condensor fan motor of Speed 900 RPM of window/Split Air conditione rcomplete all as specified and directed |
| 7 | Supply and fixingrunning capacitor clip type of cap. 50/2+4+6 MFD, 240 volts 50 cycles for window type/Split typeair conditioner 1.5 Ton.complete all as specified and directed |
| 8 | Supply and fixing over load protector with relay No 1622/2085for 1.5 Ton cap for window type AC.complete all as specified and directed |
| 9 | Material and labour for replacement of thermostat switch for AC cap.1.5/2.00 toncapacity.complete all as specified and directed |
| 10 | Material and labourfor replacement of defective wiring set (with suitable copper wire) of window type AC cap. 1.5 Ton/2 Ton complete all as specified and directed |
| 11 | Material and labourfor replacement of defective wiring set (with suitable copper wire) of split type AC cap. 1.5 Ton/2 Ton (Both indoor and outdoor unit complete all as specified and directed |
| 12 | Material and labourfor flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-22 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction complete all as specified and directedNote: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost. |
| 13 | Material and labourfor flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R -32 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction complete all as specified and directedNote: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost. |
| 14 | Material and labourfor flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-410 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction complete all as specified and directedNote: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost. |
| 15 | Material and labour for replacement of cooling coil for indoor unitsplit type ACCap.1.5 /2.0TR complete all as specified and directed |
| 16 | Material and labour for replacement of copper condenser unit (Heating Condenser) for out door unit for split type ACCap.1.5 /2.0TR complete all as specified and directed |
| 17 | Material and labour for chemical wash for indoor/out door unit for split /window type ACCap.1.5 /2.0TRcomplete all as specified and directed |
| 18 | Material and labour for replacement of cooling coil for window type ACCap.1.5 /2.0TR complete all as specified and directed |
| 19 | M/L for replacement of blade of condensing fan motor (as per sample) for window/split type (outdoor unit) AC cap1.5/2.0 Ton.complete all as specified and directed |
| 20 | Material and labourfor taking out window type AC from site of any cap.and makefor servicing incl. cleaning with air blower , cleaning and washing fins of cooling coil with caustic soda mixed water, taking out all dirt , sludge deposited, cleaning of air filter incl. oiling / greasing of condensing fan motor , spray painting of outer cover with 2 coats of synthetic enameled paint of approved colouras directed with writing of serialNo SM/MES No. and reinstalled the AC in position with fixing of putty etc. complete all as specified and directed(Note : Any damage occurred during repair for which contractor will be responsible to rectify defects without any cost to the Govt). |
| 21 | S&F in repairs of following unserviceable items in existing split type AC of existing make complete all as specified and directed |
| 22 | Connector unit |
| 23 | Foam type insulating flexible pipe fitted on suction /discharge copper tubes. |
| 24 | PCB Card for split type AC of capacity 1.5 TR |
| 25 | PCB Card for split type AC of capacity 2 TR |
| 26 | Remote hand set for split type AC 1.5/2 TR Capacity |
| 27 | Valve 1/2 \" ,1/4 \" and 5/8 \"for split type of capacity 1.5/2.0 TR |
| 28 | Cooling coil and room temperature sensor |
| 29 | Display unit for 1.5/2 Ton AC |
| 30 | Blower motor of indoor unit of split type of cap 1.5 /2 TRas per existing make/mode complete all as specified and directedl |
| 31 | copper pipe of size 1/4 \" from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed |
| 32 | copper pipe of size 1/2 \" from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed |
| 33 | copper pipe of size 5/8 \" from outdoor unit to indoor unit including soldering and brazingcomplete all as specified and directed |
| 34 | Material and labour forrefixingsplit type of capacity 1.5/2 TR from one site to another site complete all as specified and directed |
| 35 | Material and labour for replacement of PT relay for split type Acs of Capacity 1.5/2 TR as per existing make complete all as specified and directed |
| 36 | Material and labour for replacementairfilter for split type ac for 1.5/2 TR complete all as specified and directed |
| 37 | Material and labour for replacementout unit jali for split type ac for 1.5/2 TR complete all as specified and directed |
| 38 | Material and labour for replacement Outdoor fan motor as per existing for 2.0 Ton Spilt AC complete all as specified and directed |
| 39 | Material and labour for replacement Outdoor fan motor as per existing for 1.5 Ton Split AC complete all as specified and directed |
| 40 | Material and labour for replacement Compresser Capacitor as per existing for 1.5/2.0 Split type AC complete all as specified and directed |
| 41 | Material and labour for replacement Swing Patti as per existing for 1.5/2.0 Split type AC complete all as specified and directed |
| 42 | Material and labour for replacement Drain pipe as per existing for 1.5/2.0 Split type AC complete all as specified and directed |
| 43 | Material and labour for replacement Drain tray as per existing for 1.5/2.0 Split type AC complete all as specified and directed |
| 44 | Material and labour for replacement PCB Transformer as per existing for 1.5/2.0 Split type AC complete all as specified and directed |
| 45 | Material and labour for replacementPCB for 1.5/2.0 Ton Invertor type AC as per existing complete all as specified and directed |
| 46 | Material and labour for replacementFan motor of 1.5/2.0 Ton split type invertor Acs as per existing complete all as specified and directed |
| 47 | Material and labour for replacementoutdoor heating condenser of 1.5/2.0 Ton split type invertor Acs as per existing complete all as specified and directed. |
| 48 | Material and labour for replacement Sensor of 1.5/2.0 Ton split type invertor Acs as per existing complete all as specified and directed. |
| 49 | Material and labour for replacement Control remote of 1.5/2.0 Ton split type invertor Acs as per existing.complete all as specified and directed |
| 50 | Material and labour for replacement of electrical wiring two run of single core 6 sq mm (Nominal area)multithreaded copper conductor PVC insulated sheathed cable including one 4 Sq mm solid copper conductor PVC insulated cable in and including 20 mm dialrigidmetallic conduit completeincluding junction boxes with metallic sheet top cover and other accessories complete all as specified and directedNOTE:- Two run of mainwire,one run of earth wire and pipe shall be measured as one length. |
| 51 | Material and labour for replacement ofsingle pole and neutral enclosurewith 2 pinearth industrial plugand socket complete with one MCB SP 25 Amps complete all as specified and directed |
| 52 | Material and Labourfor replacement of unserviceable hermitically sealed compressor suitable forwater cooler cooling capacity 40 liters/hour with new uncut sealed compressor supplied by manufacture complete.(Makes :-Tecumesh/Kirlosker copeland)Note:- i) Old sealed compressor received from the water cooler will be property of contractorii) The ate quoted by the contractor including all charges like transportation , filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition iii )The new sealed unit will be purchased from authorized dealer. |
| 53 | Material and Labour for Replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hrcomplete all as specified and directed |
| 54 | Materialand Labour forReplacement of relay with over load protectors for 40 Ltr/hr cooling capacitysuitable as per site requirementcomplete all as specified and directed |
| 55 | Material and Labour forReplacement of condensor fan of motor HP- 1/32 ,RPM-1300 suitable forwater cooler havingcooling cap 40 Ltr/hrwith clips and motor fixing stand with fan blade. complete all as specified and directed |
| 56 | Material and Labour for Replacement of thermostat switch with knob for water cooler. having cooling capacity 40 Ltrs / hrcomplete all as specified and directed( Make : Renutrol no 1051 or Indofoss No2064/Annapurna ) |
| 57 | Material and Labour forReplacement of starting capacitor 40/60 Mfd oil filled240 volt AC Supplycomplete all as specified and directed Make ; Tesla |
| 58 | Material and Labour for Replacement of running capacitor of 10 Mfd oil filled complete all as specified and directedMake: Asian/ Atlas/Epcos/SPAN/Sharda |
| 59 | Material and Labour for Replacement ofcapacitor of 3 Mfd complete all as specified and directed Make: Asian/ Atlas/Epcos/SPAN |
| 60 | Material and Labour for brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple complete all as specified and directed |
| 61 | Material and Labour for replacement of top cover of water cooler with rubber beading, hinges screws etc complete for 40 Ltr/Hr cap. water cooler complete all as specified and directed |
| 62 | Material and Labour for rewinding of condensing fan motor of water cooler (1/35 HP) cap. 40 Ltr/Hr with supper enameled copper wire of suitable gauge (Make: Devidayal/Chetak/Atlatcomplete incl. insulating material and replacement of gun metal bush & capacitor 2.5 MFD. complete all as specified and directed( Make:Epcos/Asian /Unistar) |
| 63 | Material and labour for replacement of fan blade for condensing fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/Hr water cooler. complete all as specified and directed |
| 64 | Material and Labourforcondenser unit complete suitable for 40 Ltr/Hr cap. water cooler repairs of leakages in system including gas charging flushing out the system brazing,welding and jointing the suction reed and discharge reedcomplete all as specified and directed |
| 65 | Material and labourfor flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with suitable refrigerant, oil charging complete in compressor of water coolar all as directed & with entire satisfactioncomplete all as specified and directedNote: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost. |
| 66 | Material and labour for rewinding of Desert Cooler fan motor 3 speed,1400 RPM any make of cap. 1/5 HP with super enameled copper wire of appropriate size . Make: DEVIDAYAL /CHETAK complete incl. replacement ofbush, shaft and oil filled capacitor 4 MFD,240 voltsof complete all as specified and directed Make: Unistar / Kell/ Asian/ Siemens. |
| 67 | Material and labour for replacementof oil filled type capacitor for fan motor cap. 4 MFD , 240 voltscomplete all as specified and directed suitable for desert cooler fan motor . Make: Unistar/ KELL /Asian/Siemens/Jyoti . |
| 68 | Material and labour for replacement of front grill (moveable) of the Desert Cooler made out of 20 gauge PGI sheet complete incl.Selector switch with knob,indicator etc. Suitable for 4000 /5000 cfmDesert Cooler complete all as specified and directed |
| 69 | Material and Labour for replacment ofBottom water tank of size 750x750x200 mm fabricated out of 18 gauge PGI sheet.inclnuts bolts and washers etccomplete all as specified and directed |
| 70 | Material and labour for replacement of side supporting columns to be fabricated out of 20 gauges PGI sheet of size 80x80x800 mm incl. necessary nut, bolts etc . complete all as specified and directed |
| 71 | Material and labour for replacement of side penal made out of 22 gauge PGI Sheet with suitable handles including painting to match with the existing desert cooler complete all as specified and directed |
| 72 | Material and labour for replacement of top covermade out of 22 gauge PGI Sheet including painting to match with the existing desert coolercomplete all as specified and directed |
| 73 | Material and labour for painting to old steel surfaces of Desert cooler up to 5000 cfm with two coatsof synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES NO etccomplete all as specified and directed |
| 74 | Material and labour for replacement of Desert Cooler fan motor cap. 1/5 HP threespeed, 1400 RPM single phase with fan blade, stand and selector switch. complete all as specified and directed Make: Crompton/ GEC/COOL HOME. |
| 75 | Material and labour replacement ofsubmersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 wattcomplete all as specified and directed |
| 76 | Material and labour for replacement of Wood / wool chips pad for Desert Cooler of size 00 x 550 x30 mm (set of three pads) superior quality . complete all as specified and directed |
| 77 | Material and labour for replacement of supporting jali of wood/wool chips pad set made out of hard MS wire and fitted in side louvers complete all as specified and directed |
| 78 | Material and labour for replacementof selector switch with knob three speed for D/C fan motorcomplete all as specified and directed. |
| 79 | Material and labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 23/0.0076 cross sectional area superior qualitycomplete all as specified and directed |
| 80 | Material and labour for replacement of PVC water distributor of 3 out lets withMS nuts & bolts complete (as per sample) complete all as specified and directed |
| 81 | Material and labour for replacement ofPVC elbow suitable for desert cooler (as per sample) complete all as specified and directed |
| 82 | Material and labour for replacement of PVC pipe 15 mm dia heavy duty for D/Cooler Pumpcomplete all as specified and directed |
| 83 | Material and labour for replacement of3 pin plug top cap 5 Amp AC 240 Volts 50 Hzcomplete all as specified and directed |
| 84 | Material and labour for replacement of motor fixing ring for desert cooler eight screw / clip type(asper sample) complete all as specified and directed |
| 85 | Supply and fix in repair voltage stablizer for automatic operation single phase naturally air cooled indoor type having low and high voltage cut-off protection, inbuilt thermal protection & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and of capacity of 5 KVA wall mountable.complete all as specified and directed.Make: V guard VND 500 or equivalent in blue bird or microtech complete all as specified and directed. Note: rates for fixing of existing ACs and power supply via volatge stabilizer deemed to be considered in quoted rates. |
| 86 | Material and labour for taking out deep frezzer of any size and any make to the workshop for general body work repairs including patch work and hinges and locking work complete after removing rusted part and repairing complete fabrication work what ever is required complete making it in good presentable condition after painting work complete all as specified and directedNote: Rates for transportation to and fro from site to workshop shall be deemed to be included in the quoted rates. |
| 87 | Material and Labourfor flushing of system , testing and repairs of leakages in system charging of Gas(between inner cooling cabin and outer fabrication) , Oil complete incl. testing andcommissioning of deep frezzer of capacity upto 300 Ltrs of any makecomplete all as specified and directedNote: Spares to be used in repair,gas charging and transportation to workshop and back to site shall be deemed to be included in the quoted rates. |
| 88 | Material and Labourfor replacement of unserviceable hermitically sealed compressor suitable fordeep freezer of capacity 300 Ltrs with new uncut sealed compressor supplied by manufacture complete.(Makes :-Tecumesh/Kirlosker copeland)Note i) Old sealed compressor received from the water cooler will be property of contractor(ii) The rate quoted by the contractor including all charges like transportation, filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition.( iii )The new sealed unit will be purchased from authorized dealer. |
| 89 | Supply onlyDesert cooler metal body tank capacity 50ltrs fan rpm 1275 rpm heavy duty copper wound single phase motor cooling media as as per overall size 650mm X 650mm X 800mm consisting of thick metal sheet with inbuilt flotvalve 18 inch anti corresive painted fan & motor body complete and large pad area with heavy duty water circulating submercible pump with flexible pipe,delivers & acessories and power consumtipion 230V 50 Hz 235 watt complete, miniumum 2 years warranty by the dealer complete all as specified and directed |
| 90 | Material and labourfor replacement of unserviceable hermiticallysealed compressor of Refrigerator 310/280 Ltr. Capacity with fresh new uncut sealed compressor including +suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage,gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii)The new unit will be purchased from authorizeddelar Make: Carrier/Voltas |
| 91 | All as per ser item No82 above but for 165/170/180 Ltr capacity refrigerator .Make. Carrier/Voltas |
| 92 | Material and labour for replacement of relay suitable for 280/310 Liters cap.refrigerator (Make:- Renutrol/Shriram/Anpurna/KLIXON) |
| 93 | all as per ser item No 84 but cap 165 Literscomplete all as specified and directed |
| 94 | Material and labour for replacement of thermostat automatic `R\" frost with knob suitable for 165/286/310 liters cap refrigerator (Make :-Anpurna/Indofos) |
| 95 | Material and labourfor replacement of door gasket of best quality complete suitablefor 280/310 liters cap. refrigerator as per manufacturer\"s instructioncomplete all as specified and directed |
| 96 | All as per ser item No.87 above but for 165 Ltrs Cap. complete all as specified and directed |
| 97 | Material and labour for replacement Bulb for pin /screw type , 230 Volts suitable for 286/310 Ltrs Cap. Refrigerator complete all as specified and directed |
| 98 | Material and labour for preparation of surfaces andpainting with applying two coats of synthetic enamel paint old paintedon external surfaces of refrigerator except cooling coil and the compressor unit which will be painted with two coats of heat resistant black paint for 286/310 ltrs capacity refrigerator including writing of the words in height unto 4cm i.e. SM No MES No complete all as specified and directed.(Note: Refrigerators to be painted at different locations of different units) |
| 99 | All as per ser item No.90 above but 165 Ltrs capacity.refrigerator complete all as specified and directed |
| 100 | Material and labourfor replacement of refrigerator door handle of 165/ 286/310 Ltrs Cap. of any make.and model complete all as specified and directed |
| 101 | Material and labourfor replacement offreezer assy (including gas charging R-134/600 ) complete with screw, jointing of tubes etc. and testing of cap. 280/310165 Ltrs. refrigeratorcomplete all as specified and directed |
| 102 | All as per ser item No.93 above butof capacity 165/175 Ltr refrigeratorcomplete all as specified and directed |
| 103 | Material and labourfor replacement of condensor unit of refrigerator cap. 280/310 Ltrs of any make includingjointing of tubes andtesting etc. complete all as specified and directed.(gas charging will be measure and paid under relevant item separately ) |
| 104 | All as per ser item No.95 above butfor 165 ltrs capacity refrigerator.complete all as specified and directed |
| 105 | Material and labourfor replacement of timer of refrigerator cap. 280/310/165 Ltrs of any make complete all as specified and directed |
| 106 | Material and labourfor replacement of PCB of refrigerator cap. 280/310/165 Ltrs of any make complete all as specified and directed.Hitachi/Voltas |
| 107 | M & L for replacement of cooling coil of refrigerator cap 280/310/165 Ltrs as per existing complete all as specified and directed |
| 108 | M & L for replacement of capilary of refrigerator cap 280/310/165 Ltrs as per existing complete all as specified and directed |