Repair Replacement Of Lt Line And Electrical Appliances At Sub Station Controlled Switch Gear Earthing Security Light And Connected Items At Af Stn Rajokri Under Age Em Af Rajokri Of Ge Af Gurgaon Repair Replacement Of Lt Line And Electrical Appliances A, GE (AF) Gurgaon-Haryana

Military Engineer Services-MES has published Repair Replacement Of Lt Line And Electrical Appliances At Sub Station Controlled Switch Gear Earthing Security Light And Connected Items At Af Stn Rajokri Under Age Em Af Rajokri Of Ge Af Gurgaon Repair Replacement Of Lt Line And Electrical Appliances A. Submission Date for this Tender is 27-10-2021. Electrification Work Tenders in GE (AF) Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

29375972
Corrigendum : Repair Replacement Of Lt Line And Electrical Appliances At Sub Station Controlled Switch Gear Earthing Security Light And Connected Items At Af Stn Rajokri Under Age Em Af Rajokri Of Ge Af Gurgaon Repair Replacement Of Lt Line And Electrical Appliances A
Open Tender
Indian
Haryana
GE (AF) Gurgaon
27-10-2021

Tender Details

Repair Replacement Of Lt Line And Electrical Appliances At Sub Station Controlled Switch Gear Earthing Security Light And Connected Items At Af Stn Rajokri Under Age Em Af Rajokri Of Ge Af Gurgaon Repair Replacement Of Lt Line And Electrical Appliances At Sub Station Controlled Switch Gear Earthing Security Light And Connected Items At Af Stn Rajokri Under Age Em Af Rajokri Of Ge Af Gurgaon

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Oct-2021 Amendment Other 20-10-2021
2 20-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work : REPAIR REPLACEMENT OF LT LINE AND ELECTRICAL APPLIANCES AT SUB STATIONCONTROLLED SWITCH GEAR EARTHING SECURITY LIGHT AND CONNECTED ITEMS AT AF STN RAJOKRI UNDER AGE EM AF RAJOKRI OF GE AF GURGAON
Sl. No. Item Description
1Supply ,installation ,testing and commissioning of copper chemical earthing as per IS:3043 with size 3 meter long, 50mm dia outer pipe of thickness 2mm filled with highly conducting metellic compounds in gel foam & both end sealed ,electrolytic copper earthing electrodes.The earth pits shall be filled with sufficient quantity ultra high conductive backfill compound with neccessary accessories like lockable pit cover etc complete as required as per standard practices and specification all as specified and as directed.Note: (i) The concrete pit shall be PCC 1:3:6 type C-1 and 40 mm thick pre -cast cover slab of RCC(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided.
2Supply and fixingAir termination, single pointed, copper rod 12mm dia and 300mm long all as specified and as directed
3Supply and fixingCopper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed.
4Supply and fixingmade of gun metal or phosphorus bronze size 75x75x25mm drilled, screwed including 3 nos. 8mm dia 25mm long hex. head screw & brezing all jointscomplet all as specified & directed
5Taking downAir termination, single pointed, copper rod 12mm dia and 300mm long all as specified and as directed .
6Taking down20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and as directed.
7Taking downtest point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw all as specified and as directed.
8Supply and fixing submain wiring with PVC sheathed multi-stranded copper conductor cable 1100 volts grade drawn through in and including steel conduit medium grade of not less than 25 mm dia with conduit accessaries and on pole for1.5 sqmm x 3core andcomplete all as specified and as directed .
9Material and labour for testing ofGI strip type /copper chemical type earthing installed at site with the earth resistance machine and getting the desired output result of less than one ohm all as specified and as directed. Note :-a.The contractor has to arrange the earth resistance machine for the testing of earthing any type b.Cost of equipment, tools & plants & material required for getting the desired output result deemed to be included in the quoted rates.
10M & L for Earthing complete with Copper earth plate electrode 60cmx60cmx3.00mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using Copper iron strip 20×3mm as earthing lead by means ofbolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel, wire meshand 40 mm dia GI protection pipe light grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.
11Supply and installation in replecement of Hot dipped Octagonal galvanized iron pole 8 mtr height, with necessary Foundation RCC 1:1:5:3 with 8Nos.16 mm dia tor bar as main bars and 8mm dia.Tor bars strips@190mm c/c as this reinforcement shall confirm to IS : 1786 latest edition.The foundation shall extend above surroundings ground/drive way level for 200 mm and have DWC 63 mm dia,PVC sleeve cast foundation for cable entry,Excavation,RCC and reinforcement etc as per manufacturer recommendation and the cost ofnecessary foundation , steel bars , strip as per Manufacturer instructions .
12Excavation in trenches not exceeding 1.5 m wide and and not exceeding 1.5 m depth in loose/soft soil and getting out soil all as specified and directed.
13Returning, filling in, with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm completeall as specified and directed.
14Removal of surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete as specified and directed.
15M&L for boring/auguring suitable hole & insertion of pipenot less than 600 mm below existing PCC/road/hard standing complete all directed. Notes:- Cost of equipment, tools & plants & material required for boring shall be deemed to be included in the rates quoted.
16Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
17Supply and laying un-reinforced precast concrete LV cable cover class Type I with 250 x 150 x 40 mm, as specified and directed.
18Taking downthe existing cables from trenches of size up to 25 sqmm 1100 Volt grade completeall as specified and directed.
19Taking downthe existing cables from trenches of Size 35sqmm to 50 sqmm 1100 Volt grade completeall as specified and directed.
20Taking downthe existing cables from trenches of 70 to 120 sqmm 1100 Volt grade completeall as specified and directed.
21Taking downthe existing cables from trenches of 95 sqmm 11000 Volt grade (HT) completeall as specified and directed.
22Supplying and laying in repair XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electrical power cable ( heavy duty ) with aluminum conductor, 11000 volts grade cross sectional area 95 Sqmm x 3 core complete all as specified and directed
23Supply, jointing and testing indoor/outdoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 50-95 Sqmm XLPE cable of 11000 volts (E)grade complete all as specified and directed. (Make / Model - Birla 3 M Ltd, raychem rpg) Note : Cost of cutting of existing end termination joint deemed to be included in unit rate.
24Supply, jointing and testing indoor / out door type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core X 120-185 Sqmm XLPE cable of 11000 volts (E)grade complete all as specified and directed. (Make / Model - Birla 3 M Ltd, raychem rpg) Note : Cost of cutting of existing end termination joint deemed to be included in unit rate.
25M &L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type complete with joining material and accessory suitable for 95sqmm 3 core XLPE armored aluminum conductor cable complete all as specified and directed
26M &L for cable jointing kit for 1.1 KV (Earthed) grade cable for straight through Heat shrink type complete with joining material and accessory suitable for up to 25sqmm 3.5 core XLPE armored aluminum conductor cable complete all as specified and directed
27M &L for cable jointing kit for 1.1 KV (Earthed) grade cable for straight through Heat shrink type complete with joining material and accessory suitable for 35 sqmm to 50 Sqmm 3.5 core XLPE armored aluminum conductor cable complete all as specified and directed
28M &L for cable jointing kit for 1.1 KV (Earthed) grade cable for straight through Heat shrink type complete with joining material and accessory suitable for 70 sqmm to 120 Sqmm 3.5 core XLPE armored aluminum conductor cable complete all as specified and directed
29M &L forcable jointing kit for 1.1 KV (Earthed) grade cable for straight through Heat shrink type complete with joining material and accessory suitable for 185sqmm to 240 Sqmm 3.5 core XLPE armored aluminum conductor cable complete all as specified and directed
30M&L for defect rectification of HT 11 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pules, ECHO fault locator with high frequency distance calculator for cable of size 95 Sqmm x 3 core XLPE 11 KV complete all as specified and directed
31Supply, laying, jointing and testing XLPELTCable insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 4.0 core x 25Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
32Supply, laying, jointing and testing XLPELTCable insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 2core x 25Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
33Supply, laying, jointing and testing XLPELTCable insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 3.5 core x 35Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
34Supply, laying, jointing and testing XLPELTCable insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 3.5core x 50Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
35Supply, laying, jointing and testing XLPELT insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 3.5core x70Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
36Supply, laying, jointing and testing XLPELT insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 3.5core x95Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
37Supply ,installation ,testing and commissioningin replacement of feeder pillar boardof size 60 cm X 45 cm X 30 cm Kiosktype ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) floor mounted , factory assembled, outdoor typeweather and vermin proof (Protection Class IP-54) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatmentand lifting channel, fully compartmentalized design comple Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 400 Amps with colour coding complete all as specified and as directed.
38Supply and fixing in repair,MCCB 250 Amp,3 pole,microprocessor based ,36 KA including under voltage/over voltage relay all as specified and directed.
39Supply and fixedin repair,MCCB200 Amp ,3 pole,microprocessor based ,25 KA including under voltage/over voltage relay all as specified and directed.
40Supply and fixedin repair,MCCB125 Amp ,3 pole,microprocessor based ,16 KA including under voltage/over voltage relay all as specified and directed.
41Material and labour for preparation of old painted surface of steel surface by brushing /cleaning strain grease /oily spots with tinner and two coats of spray painting with spray machine to ,Bus bar Chamber ,feeder pillar box, load line DB and power factor panel etc . complete all as specified and as directed.
42Supply, laying, jointing and testing XLPE insulated,PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098of 1995 and of size 3.5core x 120 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
43Material and labourfor laying GI tubingof size 50mm bore ,light gradefor protection of under groundcablein trench /under road /croosingor fixed to wall /pole all as specified and directed
44Comprehensive maintainance of oil cooled servo voltage stablizer by isolating ,disconnecting of input/output ,supply cable,opening of top of voltage stablizer,detecting of fault ,u/s component in control panel /dimmerstat /PCB etc,cleaning of serviceable parts/ component ,includingreplacement of worn out spare parts etc, if required for following all as specified and directed.
45Voltage stablizer of capacity 25 KVA three phase
46Voltage stablizer of capacity 75 KVA three phase
47Voltage stablizer of capacity300 KVA three phase
48Voltage stablizer of capacity 450 KVA three phase
49M&L for Dehydration including filtration and cleaning of Transformer oil by dehydrating machine incl testing of sample before and after dehydration and filtration and replacement of silica gel all as specified and directed NOTE:- Contractor hasto arrange the dehydration machine and testing kit withoutany extra cost to the dept. Test report to be submitted after completion of job.
50Supply & Filling /pouring of up to the appropriate level Transformer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and as directed NOTE:-Dielectric strength test shall be carried out at site before poring/filling in transformers in the presence of Engr-in-Charge on the site
51Comprehensive maintainance of transformer by isolating ,disconnecting of input/output ,supply cable,opening of top of transformer,detecting of fault ,u/s componentetc,cleaning of serviceable parts/ component ,includingreplacement of worn out spare parts etc, if required for following all as specified and directed.
52Transformer 300/400KVA
53Transformer 160/250KVA
54Transformer 50/75/100KVA
55M&L For taking out VCB trolley from HT control panel 11 KV 3 phase 630 Amp , 21 kA (Make :- Siemens) and cleaning the trolley with CRCremoving all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders all as specified and as directed.
56Material and labour for calibration of IDMT numerical relay as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit for 11 KV system complete in all respect all as specified and as directed.
57M&L For taking out ACB trolley from LT control panel 415 V 3 phase 800 Amp , 50 kA, 4 Pole (Make :- schneider) and cleaning the ACB with CRCremoving all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders all as specified and as directed.
58Material and labour for calibration of ACB relay as per existing load for over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit for LT system complete in all respect all as specified and as directed.
59S&F LED security light fitting 35/36 Watt, having uniformty ratio 0.25 , high pressure die cast aluminium housing , heat resistant toughened glass frame , IP-65 protection complete with lamp & connected items and connection with suitable cable from celing rose to light fitting and fixing on GI pipe bracket made out of suitable dia gi pipe medium grade 1.2 m long bend to shape and fixed on wall with flat iron clamps nut, bolts washers etc specified and directed
60Supply and fixing in replecement of Spring charging Gear for 11KV VCB panel complete all as specified & directed
61S& F HT insulating SYNTHETIC rubber matting 2 m x 1m x12 mm thick all as specified and as directed.
62Compression/crimping type sleeve joints for jointing conductors/ jumper connections including treatment with conducting jelly for 11 KV HT conductor all as specified and as directed.
63S&F in transformer breathers sillica gel (orange) for effective beratheing & to protect transformer oil from moiture Complete all as specified & directed
64Material and labour for servicing of two pole, structure complete including replacement of unserviceable jumper, sleeve vice type connector GI Clamps "T" connector run connector run through clamps, bolts nuts washer connecting lugs/thimbles knife, contacts applyingpetroleumjelly to the moving as well as fixed contacts, tightening all the connection for its smooth functioning and preparing old painted surface of the structure such as poles, cross arms, bracing and supports clamps backplate complete painting of one coats of anti corrosive aluminium paint complete all as specified and directed. Marking the pole No/feeder name with black colour synthetic enamel paint complete all as specified and directed. Note: No Extra payment will be made for the spares required to keep the two pole structure in satisfactory functioning state throughout contract period other then given in schedules.
65Material and labour for servicing of four pole, structure complete including replacement of unserviceable jumper, sleeve vice type connector GI Clamps "T" connector runconnector run through clamps, bolts nuts washer connecting lugs/thimbles knife, contacts applyingpetroleumjelly to the moving as well fixed contacts, tightening all the connection for its smooth functioning and preparing old painted surfaceof the structure such as poles, cross arms, bracing and supports clamps backplate complete painting of one coats of anti corrosive aluminium paint complete all as specified and directed. Marking the pole No/feeder name with black colour synthetic enamel paint complete all as specified and directed. Note: No Extra payment will be made for the spares required to keep the four pole structure in satisfactory functioning state throughout contract period other then given in schedules
66Supply Only Rubbre hand Gloves suitable for 11 KV system
67supply and fix programable Digital KV meter 0-15 KV in HT VCB Panel with 4 way rotary selector switch mounting on adaptorsheet or on existing panel including necessory wiring complete all as specified and directed
68supply and fix programable Digital Ammeter 0-100 Amp in HT VCB Panel with 4 way rotary selector switch mounting on adaptorsheet or on existing panel including necessory wiring complete all as specified and directed
69Supply and fixing IDMT non directional shunt trip relay with two poles arrangement for over current protection with setting 50% to 200% and one pole for earth fault protection with setting 20% to 80% and under voltage protection. Relay should be microprocessor based numerical type. The relay shall be complete with a wide range of standered cominication protocols (Modbus , DNP 3.0, IEC 60870-5-103 etc. ) Relay shall be provide simple and powerfull operation interface. The LEDs and LCD display on the front panel shall be fully programmable to requirments including necessory wiring . The relay should be capable for minimum control following function i. Phase over current protection ii. Instantaneous short circut protection iii. earth fault over current protection iv. output relay latching Make :CromptonCat Part No CGI 14 N or equivalent in schneider/ Havells
70Supply and fixing 11 KV /110 Volt PT Fuse HT HRC complete all as specified and directed
71Material and labour for stone graded course aggregate of 40 mm grade nominal size without any vegetation or chemical including leveling/spreading surrounding HT/LT 2/4 pole structure, LT/HT panel complete all as specified directed .
72Supply and Fixing LED street light luminaire IP-66 grade of proterction with 24 High power LED of 45 watt rating and extendable upto 48 watt ratingwith unique peanut lens to ensure uniform distributioncomplete all as specified and as directed . Make: CG or its equivalent in Wipro/Havells/Philips
73Supply and fixing in repacement of steel weather proof, dust proof, duly powder coatedstreet light junction box of size 300 x 200 x 105mmincluding MCB SP 6 Amps and connecting terminals 4 way and fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and as directed. Make : Hensel/Sintex/Universal Switch Gear control Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.
74Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZAC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work,powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size ( but not less than 2.5 Sqmm)and comprising of the following:- (a) Incoming :- (i)MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA, with microprocessor release - 01 Nos (ii)Voltmeter 0-500 volts digital typewith 4 way rotary selector swicth -01No (iii)Ammeter 0-250 Amp digital type with 4 way rotary selector switch-01No (iv)CTsratio 400/5 A ,class 1, ISI marked -01 sets of three (v) Indicating lamp- 01 set of three (vi)Aluminium bus bar of rating 800A- set of four (b) Outgoing (i) MCCB 4 pole ,250Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release- 01 Nos (ii)MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release- 02 Nos (iii) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release- 02 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class "B", old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCBwithadjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
75S&F in replacement lightning arresters expulsion type complete with all fittings, 30 kilo amp discharge capacity, distribution class maximum working pressure 11000 voltsafter taking down old existing un serviceable lightning arrester etc complete all as specified and directed.
76S&F in replacement L.T. lightning arresters for outdoor use, non-liner resistor type, horn gap and choking coil, maximum working pressure 1100 voltsafter taking down old existing un serviceable lightning arrester etc complete all as specified and directed.
77S&F in replacement Gang Operated Device triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for 11000V, current rating upto 200 ampsafter taking down old existing un serviceable GOD etc complete all as specified and directed.
78Supply and fixing in replacementLED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, after taking down old existing un serviceable floof light etc complete all as specified and directed.
79M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
80S&Fon load change over switchopen executionof capacity250 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and boltsafter taking down old existing un serviceable MCCB/SDFU etc complete all as specified and directed.
81S&Fon load change over switch with SS enclosureof capacity200 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and boltsafter taking down old existing un serviceable MCCB/SDFU etc complete all as specified and directed..
82Supply and fixing in renewal of 3 pole power contactor ML-6 Cat No SS90921 mounted on any type/description LT panel/feeder pillar/wallafter taking down old existing un serviceable contactor etc complete all as specified and directed.
83Supply and fixing in renewal of 3 pole power contactor MNX-110 Cat No CS94137 mounted on any type/description LT panel/feeder pillar/wallafter taking down old existing un serviceable contactor complete all as specified and directed.
84Supply and fixing in renewal ofAnalog Time switchCat No J648B1, 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wallafter taking down old existing un serviceable time switchcomplete all as specified and directed.