Repair Work Of Residentia Lqtr. At Police Line Bharatpur. Repair Work Of Residentia Lqtr. At Police Line Bharatpur.
Tender Value
89.50 Lakhs
Estimated cost
Bid Submission
06 Oct 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
2360
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair Work Of Residentia Lqtr. At Police Line Bharatpur. Repair Work Of Residentia Lqtr. At Police Line Bharatpur.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soil. : - Main wall |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. : - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 3 | M15 grade Nominal Mix (with graded stone aggregate 20mm nominal size). |
| 4 | Demolishing cement concrete including disposal of material within 50 meters lead : - 1 : 3 : 6 or richer mix |
| 5 | Demolishing of RCC work including stacking of steel bars and disposal of unserviceable material within 50 meters lead |
| 6 | Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead : - In cement mortar |
| 7 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement for :- Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases. : - M20 grade Nominal Mix |
| 8 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for : - Suspended floors, roofs landings staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam etc. |
| 9 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. : - Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 10 | Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.: - Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 11 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc up to floor three level excluding the cost of centering and shuttering. : - 1:2:4 ( 1Cement : 2 coarse snad : 4 graded stone aggregate 20mm nominal size.) |
| 12 | Grading for roof water proofing treatment with : - Cementconcrete1:2 :4(1cement:2coarsesand:4gradedstoneaggregate20mmnominalsize) with water proof compound as per manufacture\"s specification. |
| 13 | Random Rubble stone masonry for foundation and plinth in Cement Sand mortar above 30CM thick wall in : - Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 14 | Marble stone flooring table rubbed, 18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. : - Bhaislana,Abu,Kishangarh Zebra. : - Above 3601 Cm2 Slabs |
| 15 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure \"A\" : - 30 mm thick . : - Commercial Veneer both side |
| 16 | Add extra in Flush doors : - For external teak wood lipping on flush door. : - 30mm x 6 mm |
| 17 | Add extra for Sunmica 0.8mm thick. |
| 18 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). |
| 19 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). |
| 20 | Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.: - Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 21 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : - Windows side hung (openable) |
| 22 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 23 | Providing batta (gola) 75mm x 75mm in cement concrete (1 : 2 : 4) including finishing with cement mortar 1 : 3 as per standard design. |
| 24 | Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. |
| 25 | Polished Blue Kota Stone flooring skirting, laid over 20mm thick base of C.M. 1:4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete : - For area of each slab from 2001 to 5000 Sq.Cm : - (a) 25mm thick slab. |
| 26 | Plaster on new surface on walls in cement sand mortar 1:6 including raking of joints etc. complete fine finished :- 20 mm thick |
| 27 | 12 mm thick |
| 28 | Add extra over item No. 12.7 to 12.10 for water proofing compound if used @ 2% of the cement by weight. |
| 29 | 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) |
| 30 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding : - New work (two or more coats) over and including scrapping and priming coat with cement primer |
| 31 | Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) |
| 32 | Painting with enamel paint of approved brand and manufacture to give an even shade : - Two or more coats on new work |
| 33 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding : - New work (Three or more coats) |
| 34 | Applying Birla / JK white cement based putty over cement plaster surface for making even surface. |
| 35 | Repairofdoor,windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : - (i) Wire Gauge 14 mesh x 24 gauge |
| 36 | Stopper of Aluminium with : - Double Rubber Gutka |
| 37 | Dismantling doors, windows and clearstory windows (steel or wood) shutters including chowkhats, architrave and holdfasts etc. complete and stacking within 50 meters lead : - Of area 3 square meter and below |
| 38 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 39 | P& F waste Pipe with all fitting : - P.V.C with C.P nut 32 mm |
| 40 | P.V.C with PVC nut 32 mm |
| 41 | P.V.C. with C.P. nut 40 mm dia |
| 42 | P & F Grating of approved quality/make : - Stainless Steel Sheet size 125mm dia. |
| 43 | P & F Shower arm 15mm dia of approved quality/make. : - C.P.brass heavy & superior quality 150mm Projection. |
| 44 | P & F Bath Shower of approved quality/make. : -C.P. brass fixed. |
| 45 | Labour Charges for removing WVC pan : - Indian/Orissa pan |
| 46 | Making connection of GI distribution branch with GI main including all fitting : - Upto 25mm dia |
| 47 | P & F Bib Cock (IS:8931 Mark) : - Synthetic Material (PTMT) bib cock of approved quality / make, nominal bore, 15mm 86 mm long |
| 48 | (-do-) Fancy Type, 122mm long |
| 49 | P & F Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete : - Brass wt.400 gm. 15mm |
| 50 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make for Wash basin, Gyset etc. : -Synthetic material (PTMT) Inlet connection of approved quality / make 15mm nominal size. |
| 51 | P & F Flush Cock / Flush Valve (IS : 9758 Mark) For WC of approved quality make. : - Brass / Gun metal half-turn wt. 1 kg. of approved quality / make, 25mm nominal bore. |
| 52 | P & F Full way valve (IS:778 Mark) or wheel valve of approved make : - Gun-metal 15mm nominal bore. |
| 53 | (-do-) 25mm nominal bore. |
| 54 | P & F PVC storage Tank (IS : 12701 marked indicating the BIS license No.), of approved make with cover, 25mm dia 1M long G.I. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design : - 300 (-do-) |
| 55 | 500 (-do-) |
| 56 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). : - 20mm nominal outer dia pipes |
| 57 | 32mm nominal outer dia pipes |
| 58 | Renewing glass panes, with putty and nails wherever necessary : - 4mm thick plain glass panes |
| 59 | Chopping loose and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand blasting, cleaning with a jet of water / air as necessary and getting it dried with compressed air including all scaffolding : - Depth 25mm to 50mm |
| 60 | Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-charge including cutting and making good the wall and floor. : - W.C. orissa pan with 100 mm vitreous china P or S trap |
| 61 | Labour charges for removing CI/AC pipes of all sizes including accessories with care and stacking of useful material |
| 62 | P & F rigid pvc pipe (IS:4985 mark) class II/ (4 kg./cm2) approved quality / make including joining the pipe with solvent cement rubber ring and lubricant : -75mm dia |
| 63 | 110mm dia |
| 64 | P & F rigid pvc pipe fittings (IS : 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant : - Coupler (Socket) : - 75mm dia |
| 65 | 110mm dia |
| 66 | Door Tee : - 75mm dia |
| 67 | 110mm dia |
| 68 | Bend 87.5 : - 75mm dia |
| 69 | 110mm dia |
| 70 | Pipe Clip : - 75mm dia |
| 71 | 110mm dia |
| 72 | Plain floor trap : - 110mm dia |
| 73 | Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: - Size 300 cm. dia outside & 300 Cm. depth |
| 74 | Providing and fixing T -iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1 :3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 75 | Providing and fixing steel gate, grating and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 76 | Providing and fixing 1mm thick M.S. sheet garrage door shutters with frame of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at the junction and corners including all fittings and applying a coat of approved steel primer : (Excluding cost of frames) : - Using M.S. Angle 35 x 35 x 5mm frame & diagonal braces. |
| 77 | Finishing with 25mm thick cement plaster on roofs in cement sand mortar 1 : 4 mix including water proofing compound @ 2% of cement used, with neat cement, finishing, curing etc. complete in all respect including making of 300 mm x 300 mm square. |
| 78 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : - 1st course of applying cement slurry @ 4.4 Kg/sqm’ mixed with water proofing compound ‘Impermo’ of Snowcem or equivalent conforming to IS 2645 in recommended proportions. : - IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion. : - IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area. : - IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen@ Kg/sqm.) |
| 79 | Electric work) |
| 80 | S&F following sizes (dia.) of ISI marked medium duty PVC conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. |
| 81 | 20 mm |
| 82 | 25 mm |
| 83 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles,Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch,Modular plate with grid plate,screws,making connections, testing etc. as required. |
| 84 | Short point (up to 3 mtr.) |
| 85 | Medium point (up to 6 mtr.) |
| 86 | Long point(up to 10 mtr..) |
| 87 | Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved makein surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, Hot Dipped Galvanized M.S Modular box of 20 SWG with earth terminal, 6 A modularswitch, 6 A modular socket, Modular plate with grid plate, screws, making connections, testing etc. as required. |
| 88 | On board |
| 89 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.Gr-1 |
| 90 | 3x 1.5 sq.mm |
| 91 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 92 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 93 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 94 | Supplying and fixing of power plug point Modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. Switch and socket outlet, making connection , testing , etc. as required. |
| 95 | Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 x 100 x 60 mm. on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet, making connection , testing , etc. as required. |
| 96 | P & F paper phenolic resin bondedlaminates confirming to IS : 2036 -1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc platednut and bolts as required. |
| 97 | 3.0 mm thick |
| 98 | P & F 18 SWG Sheet steel boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surface or in recessed as required. |
| 99 | 75mm x 75mm x 60mm |
| 100 | 175mm x 100mm x 60mm |
| 101 | 150mm x 75mm x 60mm |
| 102 | P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. |
| 103 | Single pole MCB |
| 104 | 6 A to 32 A rating |
| 105 | Double pole MCB |
| 106 | 40 A to63 A rating |
| 107 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required. |
| 108 | Double door (single phase) |
| 109 | 12 Way |
| 110 | P & F IS:371 marked6 amp surface type ceiling rose including making connection testing etc. as required.Gr-1 |
| 111 | P & F ISI marked6 amp bakelite batten/angle holder including making connection testing etc. as required.Gr-1 |
| 112 | P & F socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required.Gr-1 |
| 113 | P & F ISI markedding dong/musical chime bell including making connection testing etc. as required.Gr-1 |
| 114 | P & F ISI marked (IS :3854) 6 amp. flush type switch including cutting hole in tile and making connection testing etc. as required.Gr-1 |
| 115 | P & F ISI marked (IS :3854) 16 amp. flush type switch including cutting hole in tile and making connection testing etc. as required.Gr-1 |
| 116 | P & F of 3 pin 6 amp. flush type socket including cutting hole in tile and making connection testing etc. as required.Gr-1 |
| 117 | P & F 3/6 pin 16 amp flush type socket including cutting hole in tile and making connection testing etc. as required.Gr-1 |
| 118 | P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. |
| 119 | 10.0 Sq.mm |
| 120 | 2 core |
| 121 | 25.0 Sq.mm |
| 122 | 4 core |
| 123 | Maintenance free Gel EarthingwithPipe in pipe / Pipein striptechnologyfilled with anti corrosive conductive compound ( CPRI Tested )below the ground in 150 - 200 mm dia. earth pit & surrounding filled with required mineralfillingcompound ( MFC should have hygroscopic property to retain the moisture for long time to create low resistance zone) and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete testing of earth resistance as required. of following sizes. |
| 124 | With Pipe in Pipe Technology (Inner pipe dia. / Outer pipe dia. ) 80 - 100 micron GI Coating |
| 125 | GI pipe 2000 mm long, 50 / 25mm, Terminal 12 mm GI Strip |
| 126 | S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. |
| 127 | 10 SWG copper. Wire |
| 128 | P & F double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. |
| 129 | 1200 mm sweep |
| 130 | P&F of IP 20LED tube light 20W with external batten made from CRCA sheet steel suitable to replace T-8/T-12 tubelights,integral driver, 2000 lumens +/- 5% tolerance,system lumens efficacy of 100 lm/watt minimum, expected life time of 25000 burning hours, CCT 5700K, ANSI, CRI 80, Driver efficiency >85%, Life expectancy of driver min. 30000 hrs. PF 0.95 at full load/ 230 volt AC. |
| 131 | Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with \"E\" class insulation material and making connections etc. as required. (New model ceiling fan) |
| 132 | 900/1200 mm sweep (New model ceiling fan) |
| 133 | Labour charges for removing and refixing of Ceiling fan/ Exaust fanfrom site |
| 134 | Charges for oiling, greasing, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required. |
| 135 | Providing and Replacement ofball bearing of ceiling/ exhaust fan as required. (NBC/ SKF) |
| 136 | P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required |
| 137 | 5 step fan regulator 2 Module |
| 138 | P&F of Double ball bearing, capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible copper conductor ,making connections, testing etc. as required. |
| 139 | 225 mm sweep |
| 140 | S & F of capacitor of 230V/ 275V, 50Hz rating ofUsha/ Punsumi/ Priya/ Capital/ JEC/ AMCAP/ CONCAP make |
| 141 | Running capacitor |
| 142 | 4.0 micro farad |
| 143 | SITC of quick make and quick break4 POLEcurrent limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. |
| 144 | With Thermal Magnetic release |
| 145 | up to 100 Amp , 16 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 146 | SITC of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of CRCA sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadeThe panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator) |
| 147 | Supplying and fixing of Aluminium / Copper bus barby means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. |
| 148 | Electrolytic grade Aluminium bus bar |
| 149 | SF of110/220 V, LED (22.5 mm dia ) Indicatinglamp with integral circuit, terminal block, including connection etc. as required. |
| 150 | Red/yellow/Green colour |
| 151 | P & Fof IP20 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Downlight with die-cast aluminum housing & Heat Sink for heat dissipation, high purity reflector with external BIS certified 2.5 KV surge protected driver having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of = 100 lm / watt andlife time of minimum35000 Burning Hours with 70% of intial Lumen maintaned, CCT 3000°K / 4000°K/ 6000°K , maximum power consumption should not more than the specified rating and Fixture shall be of CE complianed. |
| 152 | Surface Mounting |
| 153 | LED Downlight 12 W |
| 154 | Labour charges for dismantling of surface PVC/ Steel conduit including wiring in conduit,conduit fittings and depositing the same with listing of material in store. |
| 155 | Labour charges for dismantling of surface/ recessed switch board of any size and depositing the same with listing of material in store. |
| 156 | Labour charges for dismantling of switch accessories like switch, socket, ceiling rose, holder and depositing the same with listing of material in store. |
| 157 | Labour charges for dismantling of wiring in existing conduit of following size and depositing the same with listing of material in store. |
| 158 | up to 2.5 sq. mm. wire |
| 159 | 4/ 6 sq. mm. wire |
| 160 | P&F of RCBO with overload, short-circuit and earth leakage protection ISI marked (IS12640)/ conforming to IEC 61009/1 complete in all respect including making connections, testing etc. as required. |
| 161 | Two pole 100/300mA sensitivity |
| 162 | 40 A rating |
AI Tender Summary
Tender Timeline
Sep 28, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 07, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender