Public Works Department-PWD has published Sitc Of Electrical Installation, Lan And Telephone Points For Modular Furniture Installed In Various Rooms At Scert Bhawan, Defence Colony, New Delhi. Sub Head Expansion Existing Martrix Ip-Pbx System And Its Network Sitc Of Electrical Installation, L. Submission Date for this Tender is 04-10-2021. Electrical Maintenance Tenders in at site Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SITC of following card in Existing Matrix Genx IP pbx system , i/c re- numbering, programming, connection etc. as reqd. (Make - Matrix ) |
2 | SLT 20 ( Intercom Card ) |
3 | CO8 Card ( Trunk Line Card ) |
4 | NX DBM VOCODER64 Card (VOCODER Daughter-board Module for IP-PBX ) having Support Maximum 64 Simultaneous VOCODING Channels, UCS and UMG Server Licenses are Supplied with 4 Built-in VOCODER Channels, |
5 | Supplying, installation fixing and testing of SIP Phoneswith 240*64 Pixels Graphical LCD with Backlight, Built-in 16 Programmable Keys( 4 Context sensitive and 12 DSS ) for Feature, Line, Extension , hand free, volume control, ringer control, auto answer, auto dial ,re-dial., mute, conference, incoming call,Directory dialing by name,name and number display etc as reqd.( Make -Matrix ) |
6 | Supplying and fixing of following pairs kron type tag box fitted in M.S. box i/c locking arrangement etc. with connection / interconnection, testing to be connected with existing Matrix IP-PBx system etc. as reqd.(Make: - Matrix/Surya / Ushitel) |
7 | (a) 200 Pairs |
8 | (b) 20 Pairs |
9 | (c)10 pairs |
10 | Supplying and laying of 20 pairs 0.50mm dia PVC insulated, PVC sheathed copper conductor unarmoured jelly field telephone cable on surface of wall, /existing channel/pipe to extend the existing Matrix IP-PBX network etc. as reqd.( Make: - Delton /Polycab /Havell"s ) |
11 | Supply, Installation, Testing & Commissioning of 24 Port L2 Gigabit Managed Smart Switch, 2 x SFP+ 10G (Mini-GBIC),System Should have 4K Active VLANs, Switching Capacity of switch is of 128 Gbps having Forwarding performance (64-byte packet size): 95.20 Mbps, Secure Shell (SSH), RADIUS, TACACS+, 16 MB Flash Memory, 128 MB RAM, 24 x 10/100/1000 + 2 x combo Gigabit SFP+ 10G ports, GUI Based Programmable, System on Panel Indication: Link activity, Port transmission speed, 16k MAC Address Table Size, AC 120/230 V (50/60 Hz ) Internal Power Supply Unitto be installed with existing Matrix based IP-PBX system for SIP Phones Connectivity( Make: - D-Link/ Cisco / HP ) |
12 | Supplying, Installation , Testing & Commissioning of 9 U Networking Rack with comaptibility with 19" standards, Front Door with toughned Glass, 1 Fan with top mounting, Power Strip for power connections, 500mm or more depth etc as reqd. ( Make: - Ushitel / Surya / R. Tech ) |
13 | Supply, Installation, Testing & Commissioning of 24 Port loaded Jack Panel, Staggered 24 Port panel in 1U Rack Unit, Copper Alloyed Contact Material, EIA 568A/B wired, PC + glass fiber, UL 94V-0, black color, Front Port Labelling, 22-24 AWG WireAccumulation complete as required.( Make - D- Link/ Digilink / A-Link ) |
14 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. ( Make - AGK/ BEC / SETIA ) |
15 | 25 mm |
16 | 32 mm |
17 | Supply, Installation, Testing & Commissioning of CAT 6 Patch Cord 1 Mtr, 4 pair 26 AWG stranded copper wire, Pre-terminated with RJ45 plugs, Slim clear anti-snag slip on boots, Suitable for EIA 568A or 568B wiring,UL® Listed, meets all TIA and ISO requirements. Complete in all respect as required by site completion. ( Make - D-Link/ Digilink/ A-Link ) |
18 | Supplying and drawing of UTP 4 pair CAT 6 LAN in the existing surface/ recessed Steel/ PVC conduit to be connected with existing Matrix IP-PBX netowrk as required. ( Make -D- Link /Digilink / AMP ) |
19 | 1 Run |
20 | 2 Run |
21 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit to be connected with exsting Matrix IP-PBX network as required. (Make - Delton / Finolex / Polycab ) |
22 | a) 2 Pairs |
23 | Supplying and fixing following modular type switch/ socket on the existing switch box/ cover including connections etc. as required. (Make:- Legrand/ Anchor/ Crabtree ) |
24 | Internet socket Outlet |
25 | Telephone socket outlet |
26 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Make:-Copper Wire:-KEI/Havells/ Finolex/RR Kabel) |
27 | Group C |
28 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make:- MS Conduit- AKG/BEC/NIC, Copper Wire:- KEI/Havells/ Finolex/ RR Kabel, Modular switch box:- MK/ Northwest/ Legrand) |
29 | Group C |
30 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. (Make:-KEI/Havells/ Finolex/ RR Kabel) |
31 | 3X 1.5 sq.mm. |
32 | 6 X 1.5 sq.mm. |
33 | 3 X 4 sq.mm. |
34 | 6 X 4 sq.mm. |
35 | 3 x 6 sq. mm |
36 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (Make:- MS Conduit- AKG/ BEC/ NIC) |
37 | 20 mm |
38 | 25 mm |
39 | 32 mm |
40 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required .(Make:- MK/ Northwest/ Legrand) |
41 | 5/6 A switch |
42 | 15/16 A switch |
43 | 6 pin 15/16 A socket outlet |
44 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.(Make:- MK/ Northwest/ Legrand) |
45 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (Make:- MK/ Northwest/ Legrand) |
46 | 1 or 2 Module (75 mmX75 mm) |
47 | 8 Module (125 mmX125 mm) |
48 | 12 Module (200 mmX150 mm) |
49 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. .(Make:- MK/ Northwest/ Legrand) |
50 | 1 or 2 Module |
51 | 6 Module |
52 | 3 Module |
53 | Supplying & fixing Cable End Box (Loose wire box) suitable for triple pole & neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. (Make:- L&T/ Legrand/ ABB) |
54 | Supplying & fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (Make:- L&T/ Legrand/ ABB) |
55 | 12way (4 + 36), Double door |
56 | Supplying & fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole & neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with testing & commissioning etc. as required.(Make:-L&T/ Legrand/ ABB) |
57 | For 8 way, Double door SPN MCBDB |
58 | For 14 way, Double door SPN MCBDB |
59 | Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make:- L&T/ Legrand/ ABB) |
60 | 12 way, Double door |
61 | 8 way, Double door |
62 | 16 way, Double door |
63 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:- L&T/ Legrand/ ABB) |
64 | Single Pole |
65 | Single pole and neutral |
66 | Triple pole and neutral |
67 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make:- L&T/ Legrand/ ABB) |
68 | 100 Amp, 16 KA,TPMCCB |
69 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85,Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make:-Havells/Crompton/ Orient/ Khaitan) |
70 | Supplying, installation, testing & Commissioning of Surface/Wall Mounted 20W integrated LED 4 feet Fitting with Epoxy powder coated white/Grey extruded aluminium channel Complete with Mounting Brackets & accessories as required with connections. (Make :- Phillips/ Halonix/ Polycab/ Crompton/ Havells) |
71 | Supplying, installation, testing & Commissioning of36-40 Watt Eintegrated LED 2X2 Panel recessFitting with Epoxy powder coated white/Grey extruded aluminium channel housing for efficient heat dissipation Complete with Mounting Brackets , chain & accessories as required with connections. (Make :- Phillips/ Halonix/ Polycab/ Crompton/ Havells) |
72 | Supplying and Laying of one number following size XLPE insulated, PVC sheathed Aluminium conductor armoured power cable of 1.1 KV grade of following size on wall surface pipe as reqd. . (Make:- FINOLEX/RR Kable/ SKYTONE/ Havells/ Polycab/ Rallison) |
73 | 3.5x35 sqmm (Clamp with 1mm thick saddle) |
74 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make:-Northwest/ Legrand / MK) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy