State Plan 2021-22- Tss - Energy Optimization At Sewage Pump House, Kuriathy -Supply, Installation, Testing And Commissioning Of 250 Kvar Automatic Powerfactor Correction ( Apfc ) Panel And Ht Metering Cubicle Including Replacement Ofcurrent T, Work-Kerala

Kerala Water Authority-KWA has published State Plan 2021-22- Tss - Energy Optimization At Sewage Pump House, Kuriathy -Supply, Installation, Testing And Commissioning Of 250 Kvar Automatic Powerfactor Correction ( Apfc ) Panel And Ht Metering Cubicle Including Replacement Ofcurrent T. Submission Date for this Tender is 06-10-2021. Power Factor Panel Tenders in Work Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

29368573
State Plan 2021-22- Tss - Energy Optimization At Sewage Pump House, Kuriathy -Supply, Installation, Testing And Commissioning Of 250 Kvar Automatic Powerfactor Correction ( Apfc ) Panel And Ht Metering Cubicle Including Replacement Ofcurrent T
Open Tender
Indian
Kerala
Work
06-10-2021

Tender Details

State Plan 2021-22- Tss - Energy Optimization At Sewage Pump House, Kuriathy -Supply, Installation, Testing And Commissioning Of 250 Kvar Automatic Powerfactor Correction ( Apfc ) Panel And Ht Metering Cubicle Including Replacement Ofcurrent Transforme State Plan 2021-22- Tss - Energy Optimization At Sewage Pump House, Kuriathy -Supply, Installation, Testing And Commissioning Of 250 Kvar Automatic Powerfactor Correction ( Apfc ) Panel And Ht Metering Cubicle Including Replacement Ofcurrent Transforme

Key Value

Document Fees
INR 2500 /-
EMD
INR 35500.0 /-
Tender Value
INR 14 Lakhs /-

BOQ Items

Work Name:State Plan 2021-22- TSS - Energy optimization at Sewage pump house, Kuriathy - Supply, installation, testing and commissioning of 250 kVAR Automatic Power Factor Correction (APFC) Panel and HT metering cubicle including replacement of Current transformer.
Sl. No. Item Description
1Appendix A-Supply and installation of 250 kVAR APFC (Automatic Power Factor Correction) Panel
2Design and Supply, Installation, Testing & Commissioning of APFC panel boards fabricated out of 16 SWG CRCA sheet powder coated in cubicle compartmentalised, totally enclosed, free standing, floor mounted, dust and vermin proof with reinforcement of suitable size angle iron/channel, Galvanized hardware with Zinc passivation, "T" sections wherever necessary, including bottom channel supports, etc fully meeting all the requirements as specified by the Electrical Inspetorate & KSEBL standards.Suitable incomers & outgoings as mentioned below, Suitable Aluminum bus bars with heat shrink insulation sleeves and insulators, Door beadings, 75 x 40 x 40 mm C Channel Base, PANEL SIZE : W 2000 X H 2000 X D 500 mm, BUS BAR : 75 X 12 X 1 ALUMINIUM FOR PHASE & 40 X 6 X 1 ALUMINIUM FOR NEUTRAL, EARTHING : 25 X 3 X 1 mm CU BUS EARTH, CABLE ENTRY : TOP / BOTTOM.INCOMER :630A TPN 1No,METERING:2A SP MCB 6Nos, LED INDICATION (R,Y,B) 1No,MFM CONSERV 3Nos, 630/5A TAPE WOUND CT, 15VA, CL:1-3Nos,AUTO/MANUAL SWITCH 1No,APFC RELAY, 8 STAGE 1No, NEUTRAL LINK1No. OUTGOINGS: 125A TP ICS/ICW=25kA THERMAL MAGNETIC BASED MCCB WITH 3O/C, S/C, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BARRIERNEUTRAL LINK-4Nos, 80A TP ICS/ICW=25kA THERMAL MAGNETIC BASED MCCB WITH 3O/C, S/C, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BARRIERNEUTRAL LINK 1No, 63A TP ICS/ICW=325kA THERMAL MAGNETIC BASED MCCB WITH 3O/C, S/C, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BARRIERNEUTRAL LINK 1No, 32A TP ICS/ICW=25kA THERMAL MAGNETIC BASED MCCB WITH 3O/C, S/C, ROM AND 2 SETS OF SPREADER WITH INTERPHASE BARRIERNEUTRAL LINK 1No,50 kVAR CAPACITOR DUTY CONTACTOR 4Nos,25 kVAR CAPACITOR DUTY CONTACTOR 1No,15 kVAR CAPACITOR DUTY CONTACTOR 1No, 5 kVAR CAPACITOR DUTY CONTACTOR 1No,50 KVAR MPP HEAVY DUTY CAPACITOR 4Nos, 25 kVAR MPP HEAVY DUTY CAPACITOR 1No, 15 kVAR MPP HEAVY DUTY CAPACITOR 1No, 5kVAR MPP HEAVY DUTY CAPACITOR 1No, RED PUSH BUTTON WITH ELEMENT 8Nos, ILLUMINATED GREEN PUSH BUTTON WITH NC ELEMENT 8Nos, AUXILIARY CONTACTOR WITH 4NO 4NC 4Nos.
3Providing an Additional Incomer feeder in existing Main Panel for feeding power supply to proposed APFC Panel as above
4Supply, Installation, Testing & Commissioning of one number Additional Outgoing feeder of 630A rating for feeding power supply to 250 kVAR APFC Panel in the existing Main Panel installed at KWA Kuriyathi Pump House, Thiruvananthapuram. The works involves SITC of one number 630 A 4P 36kA MCCB, necessary control wirings, panel fabrication works using 16 gauge MS sheets etc complete in all respects. Also, the rate is inclusive for extending the equivalent size of existing Al busbars of Main panel to facilitate addition of new APFC PAnel outgoing feeder in this. In addition, the earthing termination works for this new panel cubicle is included in the rate.
5Supply, laying / clamping, testing and commisioning of the following XLPE insulated PVC sheathed armoured heavy duty power cable conductor of best conductivity aluminium 1.1kV grade strictly conforming to IS:1554 (Part-I) 1964 (A2XFY) of the following sizes in cable trench/cable tray /wall using Al/GI/painted MS clamps. Space between clamps not exceeding 60cms amd making good the damages colour washing etc as required and as instructed by engineer in charge.
3.5 core300Sq.mm A2XFY
4core 2.5sq.mm cu contrl cable
6Supply and making end termination with brass compression gland, earth clip and aluminum lugs for following size of XLPE insulated and PVC sheathed aluminum conductor cable of 1.1kV Grade as reqiured.
3.5 core 300sq.mm
7Earthing Conductor: Supply and laying the following sizes of strips on cable tray or wall surface, including necessary clamps (each clamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.
25mmx5mm
8Fabrication, supply and erection of supports fabricated out of MS angles (ISA), MS channel (ISMC), MS flats etc. The supports shall be painted with two coats of Zinc Chromate primer and two coats of enamel paint. The design of supports and its details shall be given for approval to site engineer in charge/consultant before execution.
9Preparation of all drawings submitting and getting approval from Electrical Inspectorate, submitting of Completion certificates and arranging inspection, getting sanctions and energisation certificates, test reports, manuals, technical details, preperation of as-built drawings, obtaining as-built/GA drawings of all equipments from concerned and also obtaining all necessary sanctions from relevant regulatory boards, obtaining power allocation & power connection etc. for commissioning of the whole installation in the premises. All statutory payments will be reimbursed on production of the original receipts.
10Appendix B- Installation of HT Metering cubicle
11Supply, Installation, Testing and Commissioning of :(A) New 11kV HT Metering CTs - 3 Nos. of Ratio:?20/5A, Accuracy class: 0.2S and Burden: 10VA and (B) New HT TOD Meter of latest KSEBL standards (3phase 4 wire HT TOD meter, DLMS compatible, Make: L&T,Accuracy Class: 0.2S, PT Ratio: 11kV/110V, Voltage: 3x63.5V, CT Current -/5A) - 1 No, (C) New 11kV HT Metering PT - 1 No. of ratio: 11kV/110V, Accuracy class: 0.2 and Burden: 25VA in the existing HT Metering cubicle after dismantling the existing CTs, PT & HT TOD Meter including replacement of existing HT Metering wiring connections completely and providing new wiring connections. Also, the HT Metering cubcile"s Al busbar modification works are required to be done to facilitate new CT instalaltion works and all associated works complete in all respects.
12Testing of above CTs, PT & TOD Meter at the TMR Division of KSEBL and obtaining test reports, doing all documentation works and suitable coordination & laisoning works with KSEB for executing the above job.
13Appendix C: Safety and miscellaneous items
14Supply and providing 5 kg. Dry chemical powder type fire extinguisher with hose and clamp including fixing in it in the walls as per regulations.
15Supply and providing 6 mm thick and 1 m wide electrical grade chequered type rubber mat to withstand 3.3 kV dielectric strength conforming to IS 5429/1969
16Supply and providing First Aid Box.
17Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.
18Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.
19Supply and providing 9 litre capacity GI fire bucket painted in post office red with primer coat of red oxide and written with white paint "FIRE" mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damage, colour washing etc. as required.
20Appendix D - Fee for KSEB
21Testing fee and all other Govt fees to be remitted to KSEBL / any other agency.
Disclaimer :