Provn Of External Services And Allied Work For Installation Of Oxygen Generation Plant And Provn Of Medical Gas Pipe Line Supply System At 165 Military Hospital Dimapur Provn Of External Services And Allied Work For Installation Of Oxygen Generation Plant, Dimapur-Nagaland

Military Engineer Services-MES has published Provn Of External Services And Allied Work For Installation Of Oxygen Generation Plant And Provn Of Medical Gas Pipe Line Supply System At 165 Military Hospital Dimapur Provn Of External Services And Allied Work For Installation Of Oxygen Generation Plant. Submission Date for this Tender is 12-10-2021. Gas Generators Tenders in Dimapur Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

29360038
Corrigendum : Provn Of External Services And Allied Work For Installation Of Oxygen Generation Plant And Provn Of Medical Gas Pipe Line Supply System At 165 Military Hospital Dimapur Provn Of External Services And Allied Work For Installation Of Oxygen Generation Plant
Open Tender
Indian
Nagaland
Dimapur
12-10-2021

Tender Details

Provn Of External Services And Allied Work For Installation Of Oxygen Generation Plant And Provn Of Medical Gas Pipe Line Supply System At 165 Military Hospital Dimapur Provn Of External Services And Allied Work For Installation Of Oxygen Generation Plant And Provn Of Medical Gas Pipe Line Supply System At 165 Military Hospital Dimapur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-10-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 183400.0 /-
Tender Value
INR 1.08 Crore /-

BOQ Items

Name of Work: PROVN OF EXTERNAL SERVICES AND ALLIED WORK FOR INSTALLATION OF OXYGEN GENERATION PLANT AND PROVN OF MEDICAL GAS PIPE LINE SUPPLY SYSTEM AT 165 MILITARY HOSPITAL DIMAPUR.
Sl. No. Item Description
1Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
2Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed.
3Excavation in trenches, n exc 1.5 m wide and depth exc. 1.50 m but n.exc 3.00 m ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed.
4Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cmcomplete all as specified and as directed .
5Removing exvated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point completeall as specified and as directed .
6Material and labour for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
7Material and labour for mild steel TMT bars 10mm dia and over, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
8Material and labour for mild steel TMT bars 6mm dia to 8 mm dia, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
9Material and labour for mild steel TMT bars 5mm dia and over upto 10 mm dia as in stirrups, cut to length bent to shape required, including cranking bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips complete all as specified and as directed.
10Material and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. (Note: Formwork and reinforcing bar shall be measured and paid separately in relevant items.)
11Material and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts concrete complete all as specified and as directed. (Note: Formwork and reinforcing bar shall be measured and paid separately in relevant items.)
12Material and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. (Note: Formwork and reinforcing bar shall be measured and paid separately in relevant items.)
13Material and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span concrete complete all as specified and as directed. (Note: Formwork and reinforcing bar shall be measured and paid separately in relevant items.)
14Material and labour for RCC M-25 (Design Mix) (using 20mm graded stone aggregate) as in Chajja complete all as specified and as directed. (Note: Formwork and reinforcing bar shall be measured and paid separately in relevant items.)
15M & L for use and waste of form work to concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to battercomplete all as specified and as directed.
16M & L for use and waste of form work to sides of pillars, posts, struts, piers, piers, columns and stanchions of square, rectangular or polygonal shapewith rough finished surfaces of concretecomplete all as specified and as directed.
17M & L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc with rough finished surfaces of concrete flat complete all as specified and as directed.
18M & L for use and waste of form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar work, etc. not exceeding 200mm thick with rough finished surfaces of concrete flat complete all as specified and as directed.
19M & L for use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges with rough finished surfaces of concrete flat complete all as specified and as directed.
20Material and labour forbrick work with sub class `B` bricks, old size,straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
21S & F mild steel framed work such as grills, gratings etc. with ornamentaland intricate design for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. conforming to Fe-290 Gde E-165 complete all as specified and directed.
22Supply and fixing expanded metal, weight not.exc. 4.00 Kg Per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel membersall as specified and directed.
23M & L for moorum/ red bajrifillings under floor or pavings, in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
24Material and labour for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
25Material and labour for earth filling under floor , spreading and leveling in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
26Material and labour for 40 mm thickPCC 1:2:4 type B0 (using 12.50 mm graded stone aggregate) as damp proof course to horizontal or vertical surfaces including necessary form works, applying evenly a coat of blown type bitumen @ 1.50 Kg / Sqm blending with clean dry sand @ 0.05 Cum / Sqm including 150 micron thick polythene film laid on a coat of bitumen primer @ 0.30 to 0.50 Kg per Sqm complete all as specified and directed.
27Materials and labour for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base of floor, finished the surface fair and even to receive subsequent layer complete all as specified and directed.
28Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smoothwithout using extra cement completeall as specified and as directed.
29Materials and labour for rendering 15mm thick plaster in cement mortar (1:6)on fair faces of brick work or concrete surfaces on wall and finished even and smooth without using extra cement complete all as specified and as directed.
30Materials and labour for rendering 15mm thick plaster in cement mortar (1:4)on fair faces of brick work or concrete surfaces on wall and finished even and smooth without using extra cement complete all as specified and as directed.
31Materials and labour for 15 mm thick rendering on fair faces of brick work mixed with water proofing compound as manufacturer instructions in cement mortar (1:4) on wall andfinished the surfaces even and smooth without using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid seperately.
32Supply only integral water proofing compound (WPC) of best quality (ISI marked on packet) completeall as specified and as directed.
33Materials and labour for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed.
34Materials and labour for preparation of new plasteredsurfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
35Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed.
36Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed.
37Supply and fixing steel work in tubular trusses i.e truss bottom, top bend, sides, side supports, holding plates, posts and base plate etc. including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 etc complete all as specified and as directed .
38Material & labour mild steel screw bolts 11mm to 15mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of boltnot exc.15cm long complete all as specified and as directed.
39Supply and fixing rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410-W (Gde E-250) quality- Acomplete all as specified andas directed.
40Material and labour for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girthand applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
41Material and labour for preparation of new or previously untreated steel or iron surfaces of any description n.exc 10 cm width or girthand applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
42Supply and fixing in repair steel rolling shutters of lath thickness 1.00 mm, gear operated type with bevel gear box and crank handles including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete all as specified and directed.
43Materials and labour for sand filling under floors or foundation with approved quality coarse sandincludingspreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose)
44Material and labour for rubber pressed glossy type vibro compaced precast colour concrete interlocking paver block made with grey cement and no pigment, any shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 grade all as specified and as directed .
45Material and labour for glazed ceramic coloured tiles (Premium Quality) of size 300x200x7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match with the shade of tiles laid over and including 10mm thick cement plaster in CM (1:4) complete all as specified and as directed.
46Supply and fixing 15mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid under floors complete all as specified and as direcetd.
47Supply and fixing 20mm bore galvanised steel water tubing medium grade including all fittings and fixed complete to walls/ceiling or laid under floors complete all as specified and as direcetd.
48Supply, hoisting and fixing in proper position ISI marked multi-layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), of capacity 1000 litres with and including ball brass valve, with polythelene float and fly nut complete screwed down or iron pipe of 20 mm dia complete all as specified and as directed .
49Supply and fixing 15mmbore bib tapscastcopper alloywith crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and as directed.
50Supply and fixing 12mm thick prelaminatedparticle boardinterior grade, prelaminated both side with decorative choice laminationsfixed with screws to timber frame work including second class hard wood beading on cutting exposed edges and polishing complete all as specified and as directed.
51Material and labour for well seasoned 2nd class hard wood timber in scantlings, clean sawn, timber framed and fixed complete all as specified and as directed.
52Materials and labour for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as infloor,finished the surface fair and even to receive subsequent layer including necessary formwork complete all as specified and directed.
53Materials and labour forPCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as inkerb stone complete all as specified and directed.
54Material and labour for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary use and waste of formwork complete all as specified and as directed.
55Material and labour for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in surface channel and like etccompleteall as specified and as directed.
56Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc.completeall as specified and as directed.
57Add or deduct for each 25 mm girth or part thereof over or under 30cm from item No. 56 here-in-before. (For adjustment only)
58Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts gradecontrolled by one way switchincluding 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continuitywire connected to common earth dolly drawn through and including stove enamelledsteel conduit, flame proof of adequate sizewith all accessoriesand PVC rectangular boxes for mounting switchsocket and fan regulator etc complete all as specified and as directed. Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
59.-Ditto- all as per item No 58.00 here-in-before butfor one 3 pin 16 Amps switch socket combination on independent boardwith 2.50 sqmmPVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.50 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor and -ditto-.
60Supply and fixing Piano switch flush button single pole one way 6 Amps complete all as specified and as directed.
61Supply and fixingswitch socket combination 2 in 1, 6A/16A, 5 in 1 flush type complete all as specified and as directed.
62Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly asearth continuity conductor, drawn through and including stove enamelledsteel conduit, flame proof of adequate size with all accessoriescomplete all as specified and as directed. Note : Three runs of 4 Sqmm cable andone run of stove enamelled steel conduit shall be measured as one unit for payment purpose.
63Supply and fixing LED light fittings 1 x 16 watt flame proof, CMRI certified recommended for gas / vapour group of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc complete with all accessorioes prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
64Supply and fixing LED light fittings 1 x 90 watt flame proof, CMRI certified recommended for gas / vapour group of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc complete with all accessorioes prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
65Supply and fixing of flame proof exhaust fan of 12" and connecting up including provision of cable from ceiling rose / connector to fan complete all as specified and directed.
66Supply and fixingMCB DB SPN 8 ways double door, powder coated including bus bar neutral link, earth bar and din rail,recessed with wall surfaces complete all as specified and as directed.
67Supply and fixing MCB 6 to 32 Amps, SP, 240 Volt "B" series, breaking capacity 10 KA complete all as specified and as directed.
68Supply and fixing MCB 6-32 Amps, SPN, 240 Volt "B" series, breaking capacity 10 KA complete all as specified and as directed.
69Supply and fix ceiling rose surface Polycarbonate/ PVC three terminal complete all as specified and as directed.
70Supply and fixingMCB DB TPN 4 ways double door,including bus bar neutral link, earth bar and din rail,recessed with wall surfaces by chase cutting and making good surfaces of wallcomplete all as specified and as directed.
71Supply and fixing isolator TPN, 63 Amps, 415 volts complete all as specified and as directed.
72Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised earthing lead of 4mm diaby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessoriesall as specified and as directed. (Note: Earth lead upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.)
73Supply and fixing filled oxygen jumbo cylinder of capacity 7000 Ltr (cylinder water capacity 46.70 Ltr approx) confirming to IS-7825 Part-II, having size of cylinder 1.445 m (height including valve) x 0.232 m (approx dia), approx weight of filled cylinder shall be 51 Kg approx with and including regulator, pressure meter and connected accessories complete all as specified and directed. complete all as specified and as directed.
74Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
75Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to requirred thickness complete all as specified and as directed. (Note: Thickness of sand cushioning after punning down shall be measured for payment purpose)
76Supply ,installation, testing and commissioning floor mounted transformer of capacity 63 KVA step down, outdoor type, 3 Phase, 50 Hz, AC oil immersed, air naturally cooled (ONAN type), with external cooling tubes/radiators, double wound core type, copper wound having voltage ratio 11 KV/433 V corresponding to principal tapping, Delta connected primary winding (HV side) and star connected on secondary winding (LV side) in accordance with vector group DYN -11 (Vector group 4) with neutral brought out on LV side and,constant output so as to alter/vary secondary voltage of +7.5 % in steps of 2.5% by means of manual offload tap changing arrangements complete and conforming to IS-1180 (Part-I): 2014, Maximum loses of transformer shall be energy efficiency level 3 as per IS-1180:2014, Temperature rise in oil 40°C and windings 45°C, Having percentage of impedence not more than 4.75% complete with all standard fittings and accesssories, gauges, first filling of transformer oil etc complete all as specified and comprising with the following fittings and accessories :- (a) Externally hand operated off-circuit Tap Switch with position indicator and locking device. (b) Conservator with oil gauge, filling hole with plug & drain hole with plug.
77(c) Under carriage with four plain rollers (d) Oil filling hole cum air release plug - 01 No (e) Drain valve cum sampling valve-01 No (f) Filter valve with plug - 01 No (g) Rating Plate & Diagram Plate - 01 No (h) Lifting lugs for Transformer - 02 Nos (j) Lifting lugs for lid -02 Nos (k) Earthing terminals - 02 Nos (l) Thermometer pocket - 01 No (m) Silica gel breather - 01 No Make: NGEF/Votamp/PME/Andrew Yule /ITF Gurgaon / Universal. Note : (i) The contractor shall provide BEE certified Transformer with latest star rating offered by the Manufacturer.(ii) The transformer shall be tested in factory premises before despatch by the representative of Accepting Officer. (iii) The quoted rate shall also deemed to be included for transformer platform of size 2500 x 2500 x 1000 mm with PCC 1:4:8 type D2 foundation and brickwork all around in CM 1:6 including plastering, whitewashing complete.
78Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, including painting of black & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed. (Note: Excavation and earth work and PCC shall be measured and paid separately under respective items)
79Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in coping of pole foundationcomplete all as specified and as directed.
80Material and labour for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed.
81Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed.
82Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz with 9 insulator of rating upto 200 Amps complete all as specified and as directed.
83Supply, install, testing and commissioning of lightening arrestor expulsion type complete with all fitings, transmission class, discharge capacity 65 KA suitable for working voltage of11000 Volts including all necessary fittings all as per IS-3070 Part-III and IEC 1994 includingcomplete all as specified and as directed.
84Supply and fixing expulsion type drop out fuse unit suitable for 11000 volt and current rating upto 50 to 100 Amps shall be mounted on and including MS channel complete with two post insulator for 11000 volts including necessary clamps, nuts, bolts , washers, the exposed steel surface shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
85M & L for LT cable route indicator of 80 mm dia CI plate duly engraved( cable LT 11 KV), bolted with 40x6mm flat MS angle iron member of height 0.6 mtr and embeded in PCC 1: 3:6 type C-2 (using 40 mm graded aggregated) of size 20cm x 20cm x 30cm block including necessary earth work complete all as specified and as directed.
86Supply and fixing Danger notice plate of 25x20cm size and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters(Local & Hindi language), figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT pole complete all as specified and as directed.
87Supply and laying broken stone aggregate of gauge 40mm to 80 mm for loose filling surrounding the transformer for protection complete all as specified and as directed.
88Supply, installationtesting and commissioning ofServo Voltage stablizer for automatic operation, 3 phase, 50 Hz, copper wound, unbalanced type for automatic controlling/regulating of coltage comprising of auto transformer, servo motor, intelligent micor controller based circuit, and other fittings and accessories, naturally oil cooled indoor type & designed for input voltage variation between 300 volt to 480 volt with output voltage stablizer at 415 V with accuracy ± 1% and rate of correction >8V/Sec and of capacity 50 KVA complete all as specified and as directed with following features complete all as specified and directed :- (a) Digital control module is equipped with an advancec Micro controller technology and self controllable design. (b) display of input and output voltage, outputload current and status indications, it has soft touch buttons for ease of operation. (c) overload protection is provided in case output feedback is disconnected orloose connected. It detects the failure and displays FAIL and output goes to minimum, whereas in normal cards output goes to maximum. (d) Low and High voltage protection shoul be provided to ensure safety of the connected load. Protection in case output feedback is disconnected or loose connected (e) Low & high voltage protection. (f) TDR is programmable from 1 second to 180 seconds and also with the option of bypassing the same through push button. (g) Hysteresis is intoduced (to a value, again programmable from 1 V to 13V) to minimize hunting of motor, when there is a lot of fluctuation in the power supply. (h) By pass arrangement.
89Supply, laying connecting and testing XLPE insulated (Earthed) cable in trenches / or fixed on pole etc in screenedPVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with stranded alluminium conductor, 11000 volts grade, cross sectional area 120 Sqmm, 3 core, Confirming to IS-7098 (Part-II) 1985 complete all as specified and as directed. Note : Earth workwill be measured and paid separately under respective item.
90Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 185 Sqmm 3.5 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etccomplete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item.
91Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 50 Sqmm 3.5 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etccomplete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item.
92Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 4 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etccomplete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item.
93Supply and fixing heat shrinkable type end termination cable jointing kit outdoor type suitable for XLPE insulated cable 120 Sqmm to 185 Sqmm size, 3 core, 11 KV including testing on completion complete all as specified and as directed.
94Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of 32 x 6mm sizeby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessoriesall as specified and as directed. (Note: Earth strip upto a length of 7.50 m from earthplate shall be deemed to be included in quoted rate.)
95Supply and fixing 100 mm bore dia GI pipe, light grade including all fittings laid under road crossings or fixed to pole complete all as specified and directed.
96Supply and fixing 80 mm bore dia GI pipe, light grade including all fittings laid under road crossings or fixed to polecomplete all as specified and directed.
97Supply, install, testing and commissioning of main LT Panel board, TPN 415 volts, 50 HZ out door kiosk type floor mounted CPRI approved factory made, double door dust, vermin and weather proof IP-65, fabricated out of crca sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connentions, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current of 200 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCBs (intake point) will be carried out with TPN coper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following:-
98(a) LT capacitor bank of capacity 5 KVARx 3 Nos, 415 volts connected with main bus bar through 32 Amps MCCB with multistage Power factor correction inbuilt with the LT Panel. (b) MCCB 125 Amp 4 Pole 50 Hz 415 Volt with thermal magnetic relaese having rupturing capacity 16 KA-01 Nos (Incoming). (c) MCCB 100 Amps 3 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 16 KA-01 Nos (Outgoing) For sub/distribution panel. (c) MCCB 32/40 Amps 3 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 16 KA-01 Nos (Outgoing) For capacitor control. (d) 3 Phase digital multi function meter model A, class 1.5 A with relay vega Series-01 Nos. (e) Indicating lamp 240 volts LED type-Set of three. (f) On load change over of 200 Amp Capacity-01 Nos (g) Single phase preventor (VSP-3) -01 Nos
99Supply, install, testing and commissioning of sub /distribution LT Panel board, TPN 415 volts, 50 HZ out door cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-65, fabricated out of crca sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connentions, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current of 200 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCBs (intake point) will be carried out with TPN coper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following:-
100(a) MCCB 100 Amp 4 Pole 50 Hz 415 Volt with thermal magnetic relaese having rupturing capacity 16 KA-01 Nos (Incoming). (b) MCCB 63 Amps 3 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 16 KA-01 Nos (Outgoing) -For oxygen plant. (c) MCCB 32 Amps 3 Pole 50 Hz 415 V with thermal magnetic release having rupturing capacity 16 KA-01 Nos (Outgoing)- for plant room lighting and sockets. (d) 3 Phase digital multi function meter model A, class 1.5 A with relay vega Series-01 Nos. (e) Indicating lamp 240 volts LED type-Set of three. (f) Single phase preventor (VSP-3) -01 Nos
101Supply, Installing, testing and commissioning sound proof acoustic enclosurediesel engine driven generating set, fully wired 415 volts, +/- 1.5%, 3 phase 4 wire 50 HZ, +/- 0.5% 0.80 PF of capacity62.5 KVA, 50KW having continous rating at 1500 RPM(Rated output 114.70KW Prime continious rating), brushless self excited and minimum of 83 BHP capacity engineturbo charged water cooled complete under NTP condition with provision for 10% overload for 1hr on 12hr running and common base plate frame engine standard instrumental panel, self exciting and self regulating control panel with accessories, self starter 12 volts with battery 90 AH , 12 volts -01 Nossystem with battery charging unit SCR typeand battery cable leads , exhaust pipe withcladdingby asbestos rope, sound proof canopy as per CPCB norms II etc. Diesel engine set as per IS 10001 and alternator as per IS -13364 with inbuilt electronic speed governer with micro processor based control panel with floor mounted fuel tank not less than 12 hours running capacity including necessary anti vibration pads including standard control panel as recommended by the manufacturer .
102(a) (i) Fly wheel to suit coupling (ii) Flexible coupling with guard, bolts and nuts,etc.for exhaust system (iii) Dry type air cleaner filters (iv) Radiator with guard and radiator fan (v) Fuel pump complete with fuel injection systems (vi) Electronic speedgovernor (vii) Fuel filter (viii) Lub oil filter (ix) Self starter 12 Volts DC (x) Exhaust silencer industrial type with pipe 3 m long (xi) Turbo charger (xii) Lub oil pump (xiii) Lub oil cooler assembly (xiv) Alternator 12 V for charging of battery (xv) One hand rotary type fuel pump connected with heavy duty pipe upto the tank (xvi) Instrumental panel with the following:- (aa) Self starting key and switch (ab) Lubricating oil pressure guage (ac) Battery charging ammeter (ad) Hour meter and RPM indicator (ae) Lub oil temp guage (af) Water temp guage (xvii) Control panel with MCCBas per OEM- 1 No (xviii) Emergency stop push button outside of the container/ Canopy.
103(b) Alternator:-It shall be self excited self generated balanced 415 volts, 3 phase, 50 Cycles per second, 62.5 KVAat 0.8 PFor nearest in higher capacity, 1500 RPM, star connected, 4 wire, drip proof enclosure, air cool with radial fan mounted on rotor, screen protected, self ventilated enclosure as per IS 4722/IS 2613 & IEC 34.10 with drip proof enclosure with damper winding on pole faces, static automatic voltage regulator to provide voltage regulation +/-1% and harmonic factor better than 2% from no load to full load from 0.8 to unity power factor, efficiency 92% at 100% load/0.8PF, voltage drop at full load = 20% and insulation of H class and above as per standard practice of OEM (c) Starting batteries 12 V, 90 AH maintenance free with suitable size of cable including fitting and terminals on angle iron frame(self starter sytem with 12 volt DC) - 01 NoMake Exide/ Amaron/Nicco/ Amco. (d) Fuel tank: Made of 1.6 mm thick CRCA sheet and having continous running of 12 hours at full load with level indicator to indicate the oil level of diesel tank, fuel strainer air vent inlet and out let connections with MS pipe of suitable size complete all as specified and as directed.
104(e) Sheet steel components pre-treated with zinc phosphate prior to polyster powder coating (f) Zinc plated or stainless steel fasteners (g) EPDM quality gasket (xix) Provison of light inside the canopy. (xx) Radiator filling access facility from out side (h) Engine and alternator shall be mounted through AVM Pads on common channel iron base frame. (j) Noise level, less than 75db (A) at 1 mtr distance controlled by providing specially designed alternator to controlled the sound at air entry and exit of the enclosure.(The make of Acoustic enclosure shall be OEM of DG Set) (Foundation: Cost of PCC foundation as per manufacturer"s instructions shall be deemed to be included in the Quoted rate)
105AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL: factory made cubicle type floor mounted LT panel board, outdoor kiosk type made out of MS angle not less than 25 x 25 x 5mm , and 3.15 thick MS CRCA sheet, fron opening type, protection class IP-65, dust, weatherproof and vermin proof duly powder coated after seven tank process, with elecctrolytic grade copper bus barof 200Amps capacity for three phase and neutral, with all standard switch gear such as power contactors, relays etc. and protection , internal wiring of adequate size PVC insulated multistranded copper conductor cable etc and also consisting of following:- (a) MCCB 415 Volts, 125 Amp, rating 4 pole 16 KA rupturing capacity, Microprocessor based release for incoming supply with overload, short circuit and earth fault protection-02 (Incoming from commercial and stand by supply). (b) Ammeter 0-100 Amps, 96x96 mm square dial flush type ISI marked with selectyor switch 3 way-01 set (c) Voltmeter 0-500 volts 96x96 mm square dial flush type ISI marked with rotary selector switch 3 way -01 set. (d) Phase indicator lamps (R-Y-B)- 1 set. (e) Frequency meter digital type 45 to 55 Hz-1 No (f) KWH Meter 3 Phase unbalanced load1200 Amps capacity incl CT coil-1 set (g) All standard relays, circuits and protection required for automatic operation of Gen Set.
106Supply installation, testing & commissioning of Oxygen Base Unit 10+10 emergncy MANIFOLD with and including OXYGEN CONTROL PANEL as per description of 2 bank of 10 sylinders. the oxygen manifold would be of above size of bulk oxygen cylinders. It is suitable to with stand a pressure of 2400 PSI.The main frame are made out of 50 X 50 X 6 mm angle iron and bottom frame of 20 X 20 mm ms square are install in such a way that the cylinders must be stage for use in upright position and are not fell down under any circumstances. The gases passed through inter-connecting tail pipes duly fitted with suitable bull nose and nut adopter for cylinder valve and tube size is 10 mm OD Copper tube duly annealed having wall thickness 1.5 mm in spiral shape and the other end of the tail pipe are fixed with non-return valve. The non return valve are fixed in brass block of size 25 mm square vertically which are fitted with high pressure copper tube of size 15mm OD having wall thickness 1.5 mm. Both the arms of manifold further fixed in automatic control panel. All the joints of copper tube, brass block, and inter connecting tubes are welded with silver brazing. Pressure release safety valve also provided. The manifold is fabricated in such a way to give distribution flow of 1500 ltrs per minute. The manifold would be enamel painted as per color code. All above work would be done strictly as per specification and entire satisfaction of Garrison Engineer complete all as specified and directed.
107Supply installation, testing & commissioning of OXYGEN CONTROL PANEL CE Marked - Fully Automatic Digital SPECIFICATION:The control panel would be supplied as a pre-tested and pr-sated self-contained unit. The control panel is installed in the middle of both arms of manifold and fabricated in such a way that it would withstand of working pressure 2400psi and test pressure would be 3500psi. It would also supply a flow of 2000 Itrs. Per minute at a pressure of 4 bar (60psi) constantly on either bank. FEATURES • Electric audio-visual indicators for each bank status. • Electrically audio-visual indicators at the time of manual changeover. • Impact and weather resistance colored cover. • Independent gauges and indicators. • manual change over from on line bank to reserve bank and vise versa. • In built low-pressure audiovisual alarm.
108Supply installation, testing & commissioning of Oxygen Base Unit 3+3 emergncy MANIFOLD with and including OXYGEN CONTROL PANEL as per description The oxygen manifold would be of above size of bulk oxygen cylinders. It is suitable to with stand a pressure of 2400 PSI.The main frame are made out of 50 X 50 X 6 mm angle iron and bottom frame of 20 X 20 mm ms square are install in such a way that the cylinders must be stage for use in upright position and are not fell down under any circumstances. The gases passed through inter-connecting tail pipes duly fitted with suitable bull nose and nut adopter for cylinder valve and tube size is 10 mm OD Copper tube duly annealed having wall thickness 1.5 mm in spiral shape and the other end of the tail pipe are fixed with non-return valve.The non return valve are fixed in brass block of size 25 mm square vertically which are fitted with high pressure copper tube of size 15mm OD having wall thickness 1.5 mm. Both the arms of manifold further fixed in automatic control panel. All the joints of copper tube, brass block, and inter connecting tubes are welded with silver brazing. Pressure release safety valve also provided. The manifold is fabricated in such a way to give distribution flow of 1500 ftrs per minute. The manifold would be degreased and purged with inert gas before commissioning. The manifold would be enamel painted as per color code. All above work would be done strictly as per specification and entire satisfaction of Garrison Engineer complete all as specified and directed.
109Supply installation, testing & commissioning of OXYGEN CONTROL PANEL CE Marked - Fully Automatic Digital SPECIFICATION:The control panel would be supplied as a pre-tested and pr-sated self-contained unit. The control panel is installed in the middle of both arms of manifold and fabricated in such a way that it would withstand of working pressure 2400psi and test pressure would be 3500psi. It would also supply a flow of 2000 Itrs. Per minute at a pressure of 4 bar (60psi) constantly on either bank. FEATURES • Electric audio-visual indicators for each bank status. • Electrically audio-visual indicators at the time of manual changeover. • Impact and weather resistance colored cover. • Independent gauges and indicators. • manual change over from on line bank to reserve bank and vise versa. • In built low-pressure audiovisual alarm.
110Supply and fixing Copper tube of 12 mm dia soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition complete all as specified and directed.
111Supply and fixing Copper tube of 15 mm dia soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition complete all as specified and directed.
112Supply and fixing Copper tube of 22 mm dia soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition complete all as specified and directed.
113Supply and fixing Copper tube of 28 mm dia soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition complete all as specified and directed.
114Supply and fixing Copper tube of 42 mm dia soiled drawn seamless deoxidized, non-arsenical, half hard, tempered and degreased as per BS EN 13348:2001 duly supported with manufacturer test certificates for physical properties and chemical composition complete all as specified and directed.
115Supply and fixing of GASTERMINAL UNIT: Terminal Units (Gas Outlets) with adaptors/probe for oxygen, compressed air and vacuum: Matching adaptors to the gas outlet mentioned above i.e. adaptor for oxygen, air and vacuum. The terminal units would have following features. a. It would be front insertion type. b. Terminal unit would have mechanism with check valve. C. Allow single hand operation. D. On first insertion of probe the probe shall sit in a standby position. At the stage there shall be no gas flow. E. Only on pressing the probe second time, the gas supply would start. F. They would close automatically when connected apparatus is removed. G. For allowing on line maintenance the terminal unit would be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened. H. The outlet would be non interchangeable for specific gas and it would accept only correct medical gas adopter/Probe. I. It would be color coded as per HTM 2022 J. The design of this outlet would be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. K. It would only supply with correct probe/ adopter.
116Supply and fixing of ISOLATION VALVES :CE Marked ISO 9001-2008 SPECIFICATION: To control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves would be provided. These valves would be of nickel-plated brass body having PTFE seat and inner outer seals. These valves would have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets would be used in between nuts and valve to prevent leakage. All the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies would be on approachable height for easily operation of 12mm dia size complete all as specified and directed.
117Supply and fixing of ISOLATION VALVES :CE Marked ISO 9001-2008 SPECIFICATION: To control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves would be provided. These valves would be of nickel-plated brass body having PTFE seat and inner outer seals. These valves would have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets would be used in between nuts and valve to prevent leakage. All the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies would be on approachable height for easily operation of 15mm dia size complete all as specified and directed.
118Supply and fixing of ISOLATION VALVES :CE Marked ISO 9001-2008 SPECIFICATION: To control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves would be provided. These valves would be of nickel-plated brass body having PTFE seat and inner outer seals. These valves would have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets would be used in between nuts and valve to prevent leakage. All the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies would be on approachable height for easily operation of 22mm dia size complete all as specified and directed.
119Supply and fixing of ISOLATION VALVES :CE Marked ISO 9001-2008 SPECIFICATION: To control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves would be provided. These valves would be of nickel-plated brass body having PTFE seat and inner outer seals. These valves would have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets would be used in between nuts and valve to prevent leakage. All the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies would be on approachable height for easily operation of 28mm dia size complete all as specified and directed.
120Supply and fixing of ISOLATION VALVES :CE Marked ISO 9001-2008 SPECIFICATION: To control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves would be provided. These valves would be of nickel-plated brass body having PTFE seat and inner outer seals. These valves would have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets would be used in between nuts and valve to prevent leakage. All the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies would be on approachable height for easily operation of 42mm dia size complete all as specified and directed.
121Supply and fixing of MEDICAL GAS MONITORING ALARM: CE Marked(AREA-WISE/MAIN) SPECIFICATION:- A Gas failure Alarm would be provided which must be capable of monitoring all the Medical Gases. This alarm would be of ELECTOMECHANCIAL TECHNOLOGY, To detect the fault, pressure sensors, which detect deviation from the normal operating limits, would be installed. Each pressure Gas would displayed by colored LEGEND"S to show normal and "Low" conditions.At the time of receiving the fault the normal windowl indicator stop indication and other window would blink and it also gives audio alarm. The alarm panel would have a test facility to check the internal circuits, mute facility for making silent the buzzer, acknowledgement facility for receiving the fault and reset facility for resetting the alarm after rectifying the fault. TECHNICAL SPECIFICATIONS 1. NO/NC type Selectable DIP switches/ sensor. 2. contacts Volt free 3. Input voltage : 240 volt AC 4. Input circuit : Optocouped by using isolating Device 5. Output Circuit : 12 volt DC. 6. Contact rating : 1 Amp/240 volt AC. 7. Window size : 26 mm/ indication lamps. 8. Colour : Bright Red/ Yellow/ Green. 9. Lead Life : More than 800 hrs. 10.Flash rate : 50 / Min. 11.Power consumption : 1.5 Wt. Maximum 12. Mounting : wall mounted 13. Temperature limit : 60 oC 14.Humidity Limit : 95% RH 15. Power supply : AC/240 Volt + 10%
122Supply and fixing of BPC Flowmeter with humidifier bottle CE MARKED- would be BPC single type Pipeline Flow Meter unit duly fitted with the fine adjustment valve. It would be backpressure compensated to bear and control the Oxygen Pressure approx. 60psl. Flow meter unit would be consisting of double wall rotta-meter has range of flow 0 to 13 Itrs. per minute with fine adjustment valve. The rotta meter and humidifier bottle would be made of clear, impact resistance polycarbonate (duly graduated). This unit would be have attachment to fit humidifier bottle of capacity 100 MI. consist of clear, impact resistance polycarbonate jar. This would also have Reciprocating on top for flow meter/plastic cap having nozzles for outlet tubes and the inlet tube end would be multi function combination bubblierl nebulizer to add the humidity and create an aerosol in Medical Gas min marks would be on jar. This unit would be supplied with PVC Clear green tube of 1.5mtrs. Long duly fitted with disposable Oxygen mask complete all as specified and as directed.
123Supply and fixing of AUTOMATIC DUAL SUPPLY CHANGE OVER SITC of automatic digital duel supply & one output oxygen gas change over, Made out of MS sheet dully powder coated, having independent pressure gauges showing incoming and outgoing gases status, with digital pressure reading and micro processed based pressure sensors, along with twin shuttle valve for auto changeover of gas along with 3 no isolation valve suitable for 200-400 LPM of oxygen flow @ 4 bar max. In case of variation in supply delivery pressure the digital reading numbers become RED and in case of normal the same numbers remain GREEN. At the time RED there should be buzzer. Two no oxygen regulator should also be provided. The unit is capable for uninterrupted oxygen supply.Necessary arrangements with control/valves and by pass system need to be catered for connection from oxygen plant and future expansion all as specified and directed.
124Supply and fixing of BHP (Bed head panel 4 ft long made out of 1.6 laminated aluminium sheet die pressed in such a shape that looks good as per requirement. The modular medical turn king system/bed head panel: would be fabricated of aluminous die pressed 1.6 mm thick imported laminated sheet in such a way to provide 100% safe and efficient means to deliver all the gases as well as electrical to the patient/staff in intensive care conditions. To enclosed all piping, electrical wires, monitor wire ect it would be also 6AMP ELECTRIC SOCKET fitted continuously running on wall The design of modular BHU would consist of aluminum section to meet the requirement of HTM 2002, NFPA and other international standard. There would be no sharp edges having smooth finish and without any visible Reciprocatings etc.It would be have ability fix medical gas outlets, electrical sockets, 4 NO.S it would be fitted with.MAKE(MEC) all as specified and directed.
125Supply and fixing of ISOLATION VALVES BOX ASSEMBLY: CE MARKED ISO 9001-2008 SPECIFICATION: To control the pressure as well as for maintenance quarter turn open at 90-degree ball type valves would be provided. These valves would be of nickel-plated brass body having PTFE seat and inner outer seals. These valves would have stainless steel ball of specific ID clearance so that line pressure would not drop. For installation only PTFE gaskets would be used in between nuts and valve to prevent leakage. All the nuts for fixing the ball valve would be of brass with brass nozzles for easily brazing with copper tube. Al ball valve assemblies would be on approachable height for easily operation. And enclosed in powder quoted visible box. TECHNICAL SPECIFICATION 1. Leakage Clause : 1 2. Temperature range : Ambient 3. Working Pressure : 7.5 bar maximum 4. Test pressure : 50 bar maximum 5. Standard : As per HTM 2022 6. Size : 15mm to 28 mm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail