}

Purchase Of Gel Documentation System For The Department Of Hod Vpa Purchase Of Gel Documentation System For The Department Of Hod Vpa , Gel Documentation System ? System Should Automatically Recognize Application-Specific Tray And Adjust Imaging Paramet, HOD,VPA, LUVAS, Hisar-Haryana

Lala Lajpat Rai University Of Veterinary And Animal Sciences-LUVAS has published Purchase Of Gel Documentation System For The Department Of Hod Vpa Purchase Of Gel Documentation System For The Department Of Hod Vpa , Gel Documentation System ? System Should Automatically Recognize Application-Specific Tray And Adjust Imaging Paramet. Submission Date for this Tender is 21-10-2021. Spare Part Tenders in HOD,VPA, LUVAS, Hisar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

29343916
Corrigendum : Purchase Of Gel Documentation System For The Department Of Hod Vpa Purchase Of Gel Documentation System For The Department Of Hod Vpa , Gel Documentation System ? System Should Automatically Recognize Application-Specific Tray And Adjust Imaging Paramet
Open Tender
Indian
Haryana
HOD,VPA, LUVAS, Hisar
21-10-2021

Tender Details

Purchase Of Gel Documentation System For The Department Of Hod Vpa Purchase Of Gel Documentation System For The Department Of Hod Vpa , Gel Documentation System ? System Should Automatically Recognize Application-Specific Tray And Adjust Imaging Parameters And Software Options Accordingly. ? System Should Do Automatic Camera Adjustments And Should Provide Flexibility To Image A Wide Variety Of Applications, Including Nucleic Acid And Protein Detection. ? Should Be Able To Visualize Stain Free Gels, Dna, Rna And Protein Gels ? System Should Have Precalibrated Focus For Any Zoom Setting Or Sample Height ? System Should Haveat Least Two Auto-Exposure Algorithms ( Rapid Or Optimal ) . ? System Should Havemultitouch Capable ? System Should Havedisplay Resolution 1, 024 X 768 Pixels 9.7 ( 24.64 Cm ) ? System Should Have 21 X 14 Cm ( W X H ) Dimensions Of Imaging Area. ? System Should Have 6.3 Mp Cmos Detector With 2.4 Μm X 2.4 Μm Pixel Size And 65.53 Pixel Density ( Gray Levels ) With >3.5 Orders Of Dynamic Range ? System Should Have Trans-Uvb ( Standard ) , Epi-White ( Standard ) , Trans-White ( Optional ) , Trans-Blue ( Optional ) Excitation Source ? System Should Have One Universal 535–645 Nm Emission Filter To Accommodate A Large Portfolio Of Detection Methods With Protein ( Stain Free Gels, Oriole Fluorescent Gel Stain, Silver Stains, Coomassie Blue Stains, Coomassiefluor Orange And Sypro Ruby Stains ) And Nucleic Acid Gels ( Ethidium Bromide, Sybr Green, Sybr Safe, Sybr Gold, Gelred Stain, Gel Green Stain, Fast Blast Dna Stain And Uview Stain ) , And Blots ( Stain Free Blots, Colorimetric Blots And Ponceau S Stain ) . ? Data Output: 16-Bit Or 8-Bit: Scn, Tiff, Jpeg Image Files ? Should Be Easy To Install Using A Single Usb Connection ? System Should Be Supplied With The Software Capable Of Accurate And In-Depth Analysis Of Gel Data. Gel Analysis Software Should Be Compatible With Window Computer. ? Software Should Not Require License Registration During Installation And Should Provide A Minimum Of Five User Licenses. Software Should Generate Publication-Ready Images. The Image Software Should Enable The Highest Level Of Automation In Hardware And Calibration. ? Software Should Have Customizable Reports, User-Defined Data Charts With Instant Access To Excel Functionality, Snapshot Tool To Copy Images, Lane Profiles, And Graphs, Easily Accessible Targeted Analysis Features, Flexible Lane And Band Detection And Quantification Tools Including Volumetric Tools ? System Should Have Safe Gel Cutting And Excision Facility. It Should Be Provided With A Uv Shield And Two Uv Proof Viewing Googles To Protect The User From Uv Lights During Direct Excision. ? System Should Be Supplied With Holder For Sample Trays, Uv Shield And Viewing Googles. ? The Quoted Model Of The Instrument Must Have Been Supplied In A Minimum Of 10 Government Institutes In Last 3 Years. The User Reserves The Right To Verify The Usability, Spare Parts Availability And Maintenance Of The Equipment. The Spare Parts Of The Instruments Must Be Made Available For A Period Of 10 Years From The Date Of Submission Of Tender.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Oct-2021 Date Extension Date 21-10-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 35000.0 /-
Tender Value
INR 7 Lakhs /-

BOQ Items

Name of Tender:PURCHASE OF Gel Documentation Systemfor the department of VPA
Sl. No. Item Description
1Gel documentation system ? System should automatically recognize application-specific tray and adjust imaging parameters and software options accordingly. ? System should do automatic camera adjustments and should provide flexibility to image a wide variety of applications, including nucleic acid and protein detection. ? Should be able to visualize stain free gels, DNA, RNA and Protein gels ? System should have precalibrated focus for any zoom setting or sample height ? System should haveat least two auto-exposure algorithms (rapid or optimal). ? System should havemultitouch capable ? System should havedisplay resolution 1,024 x 768 pixels 9.7" (24.64 cm) ? System should have 21 x 14 cm (W x H) dimensions of imaging area. ? System should have 6.3 MP CMOS detector with 2.4 µm x 2.4 µm pixel size and 65.53 pixel density (gray levels) with >3.5 orders of dynamic range ? System should have Trans-UVB (standard), Epi-white (standard), Trans-white (optional), Trans-blue (optional) excitation source ? System should have one universal 535–645 nm emission filter to accommodate a large portfolio of detection methods with protein (stain free gels, Oriole Fluorescent gel stain, silver stains, Coomassie blue stains, Coomassiefluor orange and SYPRO Ruby stains) and nucleic acid gels (Ethidium bromide, SYBR Green, SYBR Safe, SYBR Gold, GelRed stain, Gel Green stain, Fast Blast DNA stain and UView stain), and blots (Stain free blots, Colorimetric blots and Ponceau S stain). ? Data output: 16-bit or 8-bit: SCN, TIFF, JPEG image files ? Should be easy to install using a single USB connection ? System should be supplied with the software capable of accurate and in-depth analysis of gel data. Gel analysis software should be compatible with window computer. ? Software should not require license registration during installation and should provide a minimum of five user licenses. Software should generate publication-ready images. The image software should enable the highest level of automation in hardware and calibration. ? Software should have customizable reports, user-defined data charts with instant access to excel functionality, snapshot tool to copy images, lane profiles, and graphs, easily accessible targeted analysis features, flexible lane and band detection and quantification tools including volumetric tools ? System should have safe gel cutting and excision facility. It should be provided with a UV shield and two UV proof viewing googles to protect the user from UV lights during direct excision. ? System should be supplied with holder for sample trays, UV shield and viewing googles. ? The quoted model of the instrument must have been supplied in a minimum of 10 government institutes in last 3 years. The user reserves the right to verify the usability, spare parts availability and maintenance of the equipment. The spare parts of the instruments must be made available for a period of 10 years from the date of submission of tender.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail