| Sl. No. | Item Description |
| 1 | Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/ foundation of Pole / Stays / Pipe etc getting out in Hard dense soil, complete all as specified and as directed. |
| 2 | Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 Metre depth for laying of UG Cable/ foundation of Pole / Stays etc getting out insoft disintegrated rock, complete all as specified and as directed. |
| 3 | Excavating in Trenches,exc. 1.50 Metre but not exc. 3.00 Metre in depth, for laying of UG Cable/ foundation of Pole / Stays etc getting out inHard rock, complete all as specified and as directed. |
| 4 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. |
| 5 | Removing Surplus soils to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed. |
| 6 | Removing Surplus rock to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed. |
| 7 | Dismantling unserviceable Steel Tubular Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed. NOTE :(i) Unserviceable Poles will be dismantled at Ground Level and disturbed ground shall be made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.(ii) Earth work, demolition of cement concrete for taking out serviceable poles will be measured and paid seperately under relevant item |
| 8 | Demolition and dismantling cement concrete (unreinforced) in situ of any description and in any position not otherwis especifically provided for pole coping , foundation etc complete all as specified and as directed. |
| 9 | Dismantling Stay Assembly of any description and any size including Mild Steel Clamps with Bolts, Nuts and Washers etc., complete all as specified and as directed. NOTE: Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed ground shall be made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately. |
| 10 | Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed. |
| 11 | Dismantling Insulators like Pin type, Shackle type from existing Electric Poles of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed. |
| 12 | Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc., complete all as specified and as directed. |
| 13 | Dismantling Earth Wire, Cradle Guarding, etc., complete all as specified and as directed. |
| 14 | M&L Cement Concrete 1:4:8 type- D-2 (using 40mm graded stone aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., complete all as specified and as directed. |
| 15 | M&L Cement Concrete 1:3:6 type- C-2 (using 40mm graded stone aggregate) as in Foundation of Poles, Stays, etc.complete all as specified and as directed. |
| 16 | M&L Cement Concrete 1:2:4 type- B2 (using 20mm graded stone aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces fair and even including necessary formwork required at Site(s), complete all as specified and as directed. |
| 17 | Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally from Top of Coping) including writing MES Pole No. with synthetic Enamel Paint (First Grade/quality), complete all as specified and as directed. NOTE : Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items. |
| 18 | Erecting LT Steel Tubular Swaged Pole of any size/description (Serviceable Pole obtained from Item No. 7 here-in-before) including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally from Top of Coping) including writing MES Pole No. with synthetic Enamel Paint (First Grade/ quality), complete all as specified and as directed. NOTE :–(a)Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items. (b)Cost of transporting the Serviceable Pole to location of work within 500 mtr is deemed to be included in the Quoted Unit Rate. |
| 19 | M&L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 16mm, size of Plate 230x230x6mm including 7/3.15 mm Galvanised Stay Strand, complete all as specified and as directed. NOTE: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, etc., Loop Insulator, etc. will be measured and paid under approprite Items. |
| 20 | M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primerone Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed. |
| 21 | Refixing only Cross-arms, Bracings, Supports, Clamps and Back Plates (serviceable materials i.e. Structural Steel Sections obtained from Item No. 10 here-in-before) including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed. |
| 22 | S & F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 100 mm Height, 65 mm dia for 1100 Volt gradecomplete all as specified and as directed. |
| 23 | Fixing only Insulator Pin type Porcelain, Vitreous including one Galvanised Mild Steel Spindle Two Galvanised Iron Washers and One Galvanised Iron Nut, of any size 1100 Volt grade (Serviceable Insulator obtained from Item No. 11 here-in- before) complete all as specified and as directed. |
| 24 | S & F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 150mm Height, 150mm dia for 11 KV grade, complete all as specified and as directed |
| 25 | Fixing only Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, of any height and dia 11 KV grade, (Serviceable Insulator obtained from Item No.11 here-in-before) complete all as specified and as directed |
| 26 | S & F Shackle type, Porcelain, Vitreous, White or Brown Insulator of size 75 mm height 90 mm dia including Galvanised Mild Steel 31x3 mm Strap, 12 mm dia Insulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt, complete all as specified and as directed. |
| 27 | Fixing only Shackle type Porcelain, Vitreous of any size with mild steel strapInsulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt grade (Serviceable Insulator obtained from Item No. 11 here-in-before), complete all as specified and as directed. |
| 28 | S & F Disc type insulatorporcelain, vitreous,145 mm high and 255 mm dia ball and socket Type white , brown or green insulatorsingle Disc Assembly for tension with Tension Clamps for conductors working pressure 11000 Volts, complete all as specified and as directed. |
| 29 | Fixing only Disc type insulatorporcelain, vitreous,of any size and socket type white, brown or green insulator single disc assembly for tension with tension clamps for conductors working pressure 11000 Volts (Serviceable Insulator obtained from Item No. 11 here-in-before), complete all as specified and as directed. |
| 30 | S & F Loop type insulator vitreous white, brown or green, large size with overall dimensions 90 x 65mm,clearance of hole 16mm dia, complete all as specified and as directed. |
| 31 | S & F Aluminium conductor steel reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on electric poles and binding to Insulators with aluminium binding wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed.NOTE : Cost of Binding Wire is deemed to be included in the quoted Unit Rate. |
| 32 | ReleasingACSR conductor of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing the conductor, removing excess sag, maintaining proper distance between Conductors as ordered, and binding to insulators with aluminium binding wire complete all as specified and as directed. NOTE : (i) Cost of Binding Wire is deemed to be included in the Quoted Unit Rate. (ii) Dismantling ACSR or AAC Conductors from the Disturbed Span in existing position for stretching will be measured and paid seperately under respective item of schedule |
| 33 | S&F Galvanised Steel Wire 3.15 or 4.0mm dia as earth continuity conductor and fixed to pole, binding with aluminium binding wire, complete all as specified and as directed.NOTE : Cost of Binding Wire shall deem to be included in the Quoted Unit Rate. |
| 34 | S&F Cradles, hexagonal/rectangular fabricated with galvanised steel wire with 4.00 mm dia including binding with aluminium binding wire, complete all as specified and as directed.NOTE : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate. |
| 35 | ReleasingGI Wireof existing OH lines by un-binding from insulator of any description, re-fixing after stretching, re-stringing GI Wire, removing excess sag, maintaining proper distance between conductors as ordered, and binding to insulatorswith aluminium binding wire complete all as specified and as directed.NOTE : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate. |
| 36 | M&L Danger notice Plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolt and nuts of approved size, for LT, 20x15 cm size including dismantling unserviceable one, complete all as specified and as directed . |
| 37 | M&L Danger notice Plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolt and nuts of approved size, for HT 25x20 Cm size including dismantling unserviceable one, complete all as specified and as directed . |
| 38 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 10 Sqmm 2 Core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed. |
| 39 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 10 Sqmm 4 core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed |
| 40 | LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 16 Sqmm 2 core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed |
| 41 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 16 Sqmm 4 core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed. |
| 42 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 25 Sqmm 4 core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed. |
| 43 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 35 Sqmm 3 ½ core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed. |
| 44 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 50 Sqmm 3 ½ core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed. |
| 45 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 70 Sqmm 3 ½ core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed. |
| 46 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 95 Sqmm 3 ½ core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed. |
| 47 | Supply & laying LT UG XLPE sheathed PVC insulated screened,PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 Volt grade, cross-sectional area 120 Sqmm 3 ½ core,laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed. |
| 48 | Supply & laying HT XLPE cable, insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electic power cable (heavy duty) with aluminium conductor, conforming to IS:7098 (Part II), 11 KV, ‘E’ Grade, cross-sectional area 95 Sqmm 3 Core, laid in trenches / on surface of wall / along with Pole in and passing throughcable protection corrugatedpipe & connecting to GOD or transformerunitand testing, complete all as specified and as directed. |
| 49 | Laying only LT UG Cable of any description and size (serviceable Cable obtained from Item No. 50 here-in-after), laid in trenches / on surface of wall / along with pole in and passing throughcable protection corrugatedPipe & connecting to OH Lines or switch fuse unit and testing, complete all as specified and as directed.NOTE FOR( ITEM NO 38 TO 49) : (i) Earthworks, Corrugatted pipe for cable protection,will be measured and paid separatewly under appropriate Items. (ii) Steel cable glands of adequate size , aluminium cable socket/ lugs ( bottle/ plate ) of required size at end termination in panel boards/ DBs , & Mild steel flat clamp of size not less than 40x5mm for securing cable pipe along pole , on wall with nut, bolt, washers etc is deemed to be included in the item rate quoated. |
| 50 | Taking down/out unserviceable UG Cables of any Cross Sectional Area and connections and joints including pipes, bricks, etc of any description laying in trenches or fixing with walls / poles, segreating serviceable Bricks/Precast covers, pipes, cables etc, and keep in safe custody for reuse, complete all as specified and as directed.NOTE : Earthwork will be measured and paid under appropriate Items. |
| 51 | M&L cable end jointing kit outdoor termination cold shrinkable type complete withJointing materials with all accessories suitable for XLPE 11 KV (Earthed), 3 Core, armoured aluminium conductor cable of size 70 Sqmm to 95 Sqmm complete all as specified and as directed |
| 52 | Supply and laying across road crossing reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 200mm complete all as specified and as directed |
| 53 | S&F Expulsion Fuse, single pole, channel type / drop out type suitable as per site requirement with working pressure 11 KV grade of capacity 50 to 100 Amps including taking down unservice-able Fuses, complete all as specified and as directed. |
| 54 | S&F lightning Arrester Expulsion type complete with all fittings transmission class discharge capacity 65 KA suitable,for working pressure 11000 Voltsincludingdismantling of old unserviceable and connection to earth electrode, complete all as specified and directed. |
| 55 | S&F Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted on insulator and fitted on steel frame , current rating 200 Amps, mechanically operated mechanism from ground level consisting ofoperating rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable length worked from ground level and with locking arrangement mild steel flat Iron clamp 50x6 mm including dismanting old unserviceable switch air break of any descrip tion, complete all as specified and as directed |
| 56 | Supply and laying 50mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-:16205 part 24 2017, PE 63 of pressure rate 4 Kg/sq.cm with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 57 | Supply and laying 63mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-:16205 part 24 2017, PE 63 of pressure rate 4 Kg/sq.cm with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 58 | Supply and laying 77mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-:16205 part 24 2017, PE 63 of pressure rate 4 Kg/sq.cm with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 59 | Supply and laying 90mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-:16205 part 24 2017, PE 63 of pressure rate 4 Kg/sq.cm with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 60 | S&F Straight Through Joints (Epoxy Type) including Jointing Kit complete for making Joints suitable for LT UG XLPEAluminium Conductorelectric Power Cable of size 16 Sqmm to 25 Sqmm, 4 Core,1100 Volt gradecomplete all as specified and as directed. |
| 61 | S&F Straight Through Joints (Epoxy Type) including Jointing Kit complete for making Joints suitable for LT UG XLPEAluminium Conductorelectric Power Cable of size 35 Sqmm to 70 Sqmm, 4 Core,1100 Volt gradecomplete all as specified and as directed. |
| 62 | .Dismantling air break gang operated switchesHT 11 KV 3 Phaseany capacity ( 200 / 400 ) Amps vertical / horizontal mounted including insulators and operating mechanism for repair / replacement of broken / worn out components and insulators etc.with or without taking down from Pole and carrying unserviceable to store for keeping in safe custody as directed by Engnr-in-Charge.Note(i). Parts needed to be replaced shall be measured and paid seperately as supply only against appropriate item of of schedule. However labour component involved in replacement is included inunit rate quoated against this Item.The rate shall deemed to be included for handling ofserviceable materialsfor reuse to site and / or removing to MES store as directedii).Any minor repairs involved to make the GODfunctionaleven if not notified by Engnr-in-Charge shall be carried out by the Contractor without any extra cost to the Department. |
| 63 | Supply only the following parts suitable to incorporate against item No.80 above. |
| 64 | (a).Male contact / moving contact blade |
| 65 | (b).Female contact / Fix contact Jaw |
| 66 | (c).Tinned copper flexible jumper 200 A / 400 A |
| 67 | (d).MS Jumper carrierMake- Jaipuria, Pactil |
| 68 | (e). Back connector plate |
| 69 | M&Lpreparing old painted surfaces by scraping and removing old paints, rust, etc. from steel tubular poles (above the planting depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, cable protection pipe, brackets, etc. and applying one coat of red oxide zinc chrome primer, alternate yellow & black strips painting (4 No. each strip 200 mm wide) and remaining portion of pole and cross arms, cable protection pipe, brackets, etc. treated with two coats of aluminium paint,complete all as specified and as directed. |
| 70 | M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from steel tubular poles (above the planting depth and PCC Copings of 11.0 metre length pole) and Mild Steel Cross Arms, cable protection pipe, brackets, etc. and applying one coat of red oxide zinc chrome primer, alternate red & black strips painting (4 No. each strip 200 mm wide) and remaining portion of pole and cross arms, cable protection pipe, brackets, etc. treated with two coats of aluminium paint,complete all as specified and as directed. |
| 71 | M&L writing Pole No. on steel tubular (8cm in height) with synthetic enamel paint (White) on base of black paint in round shape of 15 cm dia, complete all as specified and as directed. |
| 72 | Treaming of tree branch, girth not exc. 50 mm around OH electric lines and cleaning upto 3.00 Metre from the OH Electric lines, removing tremmed branches from site (s) and stacking as ordered, complete all as specified and as directed. |
| 73 | Treaming of tree branch, girth , girth exc. 50 mm but not exc. 100 mm around OH electric lines and cleaning upto 3.00 Metre from the OH Electric lines, removing tremmed branches from site (s) and stacking as ordered, complete all as specified and as directed. |
| 74 | Treamingof tree branch, girth exc. 100 mm but not exc. 150 mm around OH electric lines and cleaning upto 3.00 Metre from the OH Electric lines, removing tremmed branches from site (s) and stacking as ordered, complete all as specified and as directed. |
| 75 | Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical /Water supply Installation premises, around Pole, along the boundary Fencing, removing rubbish from the site of work and deposting where directed not exc. 100 Metre from the starting point, complete all as specified and as directed. NOTE : The Item shall be operated maximum 2 times in the entire period of the Contract and the measurement will be taken every time independently for Payment. |
| 76 | S & F MCCB 4 Pole, 415 Volts, with Thermal release range 63 (A) breaking capacity 16 KA , Ics = 100% Icu, Thermal Magnetic : O/L & S/C protection, connecting cables of any size, testing andtaking out unserviceable one from panel , complete all as specified and as directed. |
| 77 | S&F MCCB 4 Pole, 415 Volts, with Thermal release range 100 (A) breaking capacity 25 KA , Ics = 100% Icu, Thermal Magnetic : O/L & S/C protection, connecting cables of any size, testing andtaking out unserviceable one from panel , complete all as specified and as directed. |
| 78 | S&F MCCB 4 Pole, 415 Volts, with Thermal release range 125 (A) breaking capacity 25 KA, Ics = 100% Icu, Thermal Magnetic : O/L & S/C protection, connecting cables of any size, testing andtaking out unserviceable one from panel , complete all as specified and as directed. |
| 79 | S&F MCCB 4 Pole, 415 Volts, with Thermal release range 160 (A) breaking capacity 25 KA , ,Ics = 100% Icu, Thermal Magnetic : O/L & S/C protection, connecting cables of any size, testing andtaking out unserviceable one from panel , complete all as specified and as directed. |
| 80 | S&F MCCB 4 Pole, 415 Volts, with Thermal release range 200 (A) breaking capacity 25 KA , Ics = 100% Icu, Thermal Magnetic : O/L & S/C protection,connecting cables of any size, testing andtaking out unserviceable one from panel , complete all as specified and as directed. |
| 81 | S&F MCCB 4 Pole, 415 Volts, with Thermal release range 250 (A) breaking capacity 36 KA , Ics = 100% Icu, Thermal Magnetic : O/L & S/C protection, connecting cables of any size, testing andtaking out unserviceable one from panel , complete all as specified and as directed. |
| 82 | Taking up or downPPR/ UPVC25mm or galvanised steel tubing 20 mm bore (dia) including connections and fittings from trenches, walls, floors, etc complete all as specified and as directed. |
| 83 | Taking up or down PPR/ UPVC32mm or galvanised steel tubing 25 mm bore (dia) including connections and fittings from trenches, walls, floors, etc complete all as specified and as directed. |
| 84 | Taking up or downPPR/ UPVC50 mm/ 63 mmor galvanised steel tubing 40 or 50 mm bore (dia) including connections and fittings from trenches, walls, floors, etc complete all as specified and as directed. |
| 85 | Taking up or downgalvanised steel tubing 80 mm bore (dia) with flanged ends/ socketincluding disconnecting from trenches, walls, floors, etc complete all as specified and as directed. |
| 86 | Taking up or downgalvanised steel tubing 100 mm bore (dia) with flanged ends/ socketincluding disconnecting from trenches, walls, floors, etc complete all as specified and as directed. |
| 87 | Supply &Laying Unplasticiscd PVC pipes 25 mm bore diaof pressure rating 10 kgf/cm2 complete to walls, ceilings or in floors etc. complete all as specified and as directed. |
| 88 | Supply &Laying Unplasticiscd PVC pipes 32mm bore diaof pressure rating 10 kgf/cm2 complete to walls, ceilings or in floors etc. complete all as specified and as directed. |
| 89 | Supply &Laying Unplasticiscd PVC pipes 32mm bore diaof pressure rating 10 kgf/cm2 laid in trenches complete all as specified and as directed. |
| 90 | Supply &Laying Unplasticiscd PVC pipes 50 mm bore diaof pressure rating 10 kgf/cm2 laid in trenches complete all as specified and as directed. |
| 91 | Supply &Laying Unplasticiscd PVC pipes 63 mm bore diaof pressure rating 10 kgf/cm2 laid in trenches complete all as specified and as directed. |
| 92 | Supply, laying and testing Tubes, \" Medium Grade \" galvanised, 40 mm bore with all fittings; laid in trenches complete all as specified and as directed. |
| 93 | Supply, laying and testing Tubes, \" Medium Grade \" galvanised, 50 mm bore with all fittings; laid in trenches complete all as specified and as directed. |
| 94 | Supply, laying and testing Tubes, \" Medium Grade \" galvanised, 80 mm bore with all fittings; laid in trenches complete all as specified and as directed. |
| 95 | Supply, laying and testing Tubes, \" Medium Grade \" galvanised, 100 mm bore with all fittings; laid in trenches complete all as specified and as directed.NOTE for item No 89 & 90 :(i) GI Flanged sockets, rubber or fibre board gasket wherever required will be Measured and Paid separately under respective Items as Supply only rate, however labour component involved for fixing is deemed to be included in the unit rate quoated. |
| 96 | Material and labour for joint with rubber or fibre board gasket for flanged pipe and fittings bore of pipe 80 mm |
| 97 | Material and labour for Joint with rubber or fibre board gasket for flanged pipe and fittings bore of pipe 100 mm |
| 98 | Supply only GI Flange of 80mm dia pipe with mild steel nut, bolt & washers of adequate size complete all as specified and as directed. |
| 99 | Supply only GI Flange of 100mm dia pipe with mild steel nut, bolt & washers of adequate size complete all as specified and as directed. |
| 100 | Fixing only tubes any grade 20mm bore with renewal of all fittings, to walls ceilings or laying in floors serviceable materials obtained from Item No-77 here-in before and making good the disturbed surfaces in cement mortar 1:3 complete as directed. |
| 101 | Fixing only tubes any grade 25mm bore with renewal of all fittings, to walls ceilings or laying in floors serviceable materials obtained from Item No-78 here-in before and making good the disturbed surfaces in cement mortar 1:3 complete as directed. |
| 102 | Laying only Steel Tubing 40 mm bore and connections in new or old position (in trenches.), (serviceable pipes and connections obtained from Item No.79 here-in-before) including cleaning both inner and outer surfaces of Pipes by using of wire brush, replacement of unserviceable sockets complete all as specified and as directed. |
| 103 | Laying only Steel Tubing 50 mm bore and Connections in new or old position (in trenches.), (serviceable Pipes and Connections obtained from Item No.79here-in-before) including cleaning both inner and outer surfaces of Pipes by using of wire brush, replacement of unserviceable sockets complete all as specified and as directed.NOTE FOR ITEM NO 95 to 98:(i)New GI fittings where ever required shall deem to be included in the QUOTED UNIT RATE. |
| 104 | Supplied and fixed Ball brass valveshigh pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixedcomplete all as specified and as directed for |
| 105 | (a)20 mm dia of pipe |
| 106 | (b)15 mm dia of pipe |
| 107 | S & F UPVC Ball valve 50 mm Outer dia heavy weightas per pre requirement of the site with handle screwed both ends for UPVC Pipes or for unions complete all as specified and as directed. |
| 108 | S & F UPVC Ball valve 65 mm Outer dia heavy weightas per pre requirement of the site with handle screwed both ends for UPVC Pipes or for unions complete all as specified and as directed. |
| 109 | M & L cast iron sluice valve 80mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both ends flanged, having gun metal working parts, stainless steel spindle with cast iron hand wheel with all necessary fixing arrangements such as gaskets, mild steel nuts, bolts, washers, etc. and testing including taking down unserviceable sluice valve, complete all as specified and as directed. |
| 110 | M & L cast iron sluice valve 100mm bore (dia), comply with IS:14846-2000, Class PN-1.6, both ends flanged, having gun metal working parts, stainless steel spindle with cast iron hand wheel with all necessary fixing arrangements such as gaskets, mild steel nuts, bolts, washers, etc. and testing including taking down unserviceable sluice valve, complete all as specified and as directed. |
| 111 | Dismantling water tanks and removing to store capacity Exc 250 & n exc 500 Litrscomplete all as specified and as directed. |
| 112 | Dismantling water tanks and removing to store capacity Exc 500 & n exc 1000 Litrscomplete all as specified and as directed. |
| 113 | Supply and fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I Capacity 500 Litres |
| 114 | Sypply and fixing Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I Capacity 1000 Litres |
| 115 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc in existing position capacity Exc 500 and not exc 1000 Ltrs without damaging tank complete all as specified and as directed |
| 116 | All as per item no 108 here-in before but tank size Exc 250 and not exc 500 Ltrs complete all as specified and as directed |
| 117 | Scrapping down, cleaning all Internal surfaces ofwalls, floors, roof, incoming & outgoing, over flowpipe lines , etc of RCC over head reservoir of capacityone lakh Litres located at kolhapur Military station removing the accumulated sand / silt from the chambers, depositing where directed at a distance not exc. 50 Metre complete all as specified and as directed. |
| 118 | Scrapping down, cleaning allsurfaces ofwalls, floors, roof, incoming & outgoing, over flow pipe lines , etc of RCC over head reservoir of capacity40,000 Litres located at kolhapur Military station removing the accumulated sand / silt from the chambers, depositing where directed at a distance not exc. 50 Metre complete all as specified and as directed. |
| 119 | Scrapping down, cleaning allsurfaces ofwalls, floors, roof, drainage system etc of Under Ground Clear water sumpone lakh Litres located at kolhapur Military station removing the accumulated sand / silt from the Chambers, depositing where directed at a distance not exc. 50 Metre complete all as specified and as directed. |
| 120 | Repair to water level indicator ofOH Reservoirby replacement of brass float ball 30 mm dia 2mm thick mild steel pulley flexible steel wire rope from brass float ball to measuring key and painting to indicator with 2 coat of synthetic enamelpaint and marking number with red/black reflective type colour complete and all as directed by Engr-in-charge. |
| 121 | Scraping old paint of Electric induction Motor 10HP Motor,suction , delivery pipes, sluice valves, NRV Valves (Approx coverage area 5-7 Sqm) and painting with onecoats of red oxide paint and two coat of syntheticenameal paint of shade as directed by Engnr-in-Charge including writing Sm No. , MES No.complete as all specified and as directed |
| 122 | Servicing / over hauling of 3 Phase 415 Volts 1440 RPM10 HP Mono block motor pump set (Motor Make--Kirloskar/ CG) Installed at Kolhapurpump House comprising:- (a). Taking out Motor from its Position by decoupling from Suction delivery linesand disconnecting all cable connections.(b) Dismantaling of induction Motor complete part by part carefully , testing all coils , degreasing bearingand display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts.(c) Heating & varnishingto stator with super quality varnish and dried out properely with external heat as ordered & directed(d) Replacement of pump Gasket set and gland packing rope. (e). Reassembeling the motor complete with all existingserviceable parts obtained against Item 115 (b), greasing the bearing with bearing grease and new parts (to be measured and paid separately as supply only) as ordered by Engineer in Charge. |
| 123 | (f) Reinstall the Mono block Motor pump set at its existing Position , Suction delivery lines by replacing unserviceable nut bolts of existing sizeconnecting all cable connections and testing on completion Note (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis deemed to be included in unit rate quoted against this Item. (ii). Any unforeseen minor repair and minor parts (Total cost less than Rs 200) that are not covered under Item No-116 , (a) to (e) but required to complete the repair work / smooth functioning of Motor shallbe deemed to be included in rate quoted. Transportation of Stator / Rotorparts for machining , rewinding at work shopare deemed to be included in unit rate quoted.(iii). Rewinding of stator / rotor of motor, any machine workwhere involved shall be measured and paid separetely against relevant item of this schedule. |
| 124 | Supply only the following Items of 10 HP Motor to incorporate againstItem No-115here-in-above |
| 125 | (a) DE ( Driver End ) Bearing as per existing size Make- SKF, NBC |
| 126 | (b). NDE ( Non Driver End ) Bearingas per existing size Make- SKF, NBC |
| 127 | (c) Bakelite connection terminal plate with brass nuts bolts and washers |
| 128 | (d) SS Pump Shaft sleeveforPump shaft |
| 129 | (e) CI Impeller as per Existing |
| 130 | Rewindingburnt coilsof Induction Motor stator cap 10 HPobtained from Item Ser No-115 here-in-above with super enamelled copper winding wire as per existing size and guage to achieve therequired /specifiedRPM including taking out old unserviceable winding ,cleaning/ repairing damaged slots , completeas directed |
| 131 | Welding Turningand machining works of Pump Shaft obtained from Item No 115here-in-before to true size to match with the new parts / existing serviceable parts forproperallignment and smooth operation of Motor Pump set completeall as specified and as directed |
| 132 | S & F cast Iron foot valve of size 80 mm to suction pipe of motorpump setby disconnectinglifting suction Pipe fromUG sumpand fixing in position aftertaking down existing unserviceable foot valve complete all as specified and as directedNote (i). Nuts Bolts washers and rubber gasket of adequate size requiredis deemed to be included in rate quoted against this Item. |
| 133 | Supply and fixing 3 Pole Power contractor suitable for 10 HP Motor star delta starter starter inbuilt in panelor as per existing including taking down existing unserviceable one and connecting complete all as specified and as directed. |
| 134 | Supply and fixing relay suitable for 10 HP Motor star delta starter starter or as per existing including taking down existing unserviceable one complete all as specified and as directed. |
| 135 | Supply, laying , fixing , passing through pipe or cable tray PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694,6 core 4 Sqmm 1100 Volts Grade cable includingincluding taking out old unserviceable cable connected from electric induction Motor to starter complete all as specified and as directed. |
| 136 | Supply & Installation hot dip galvanised & powder coated perforated cable tray, 12 SWG thickness, 50mm depth, width not less than 200mm,Std Length 2.5 to 3mtr, rigid structure, corrossion resistance for indoor/ outdoor application, including necessary bend, tees, cross,with all mounting and fixing accessories to walls/ ceilings as per site requirement & fixing completeall as specified and as directed |
| 137 | Servicing onlywindow type air conditioner after visiting at installed site of capacity 1.5 Ton of any make/ type by replacing unserviceable parts,and cleaning of cooling coil, condensing coil,oiling, greasing of blower motor, checking of electrical circuit installation at same location or at site as directed commissioningtesting for smooth operation and proper cooling effect complete all as specified and as directed. Note: (a).Any Parts required for replacement, charging of gas required shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis deemed to be included in unit rate quoted against this Item.(b) Rate quated shall be deemed to be inclusive of transportion from Site to work shop & back after repair within permises.( c)Any unforeseen minor repair and minor parts that are not covered under Item but required to complete the repair work / smooth functioning of AC shallbe deemed to be included with the rate quoted. |
| 138 | Supply only thefollowing Items to incorporate againstrelevant repairable summer appliances (Window AC) item No 124here-in- before |
| 139 | (a)Blower motor complete suitable for window type AC upto 1.5Ton.as on site all as specified and directed by Engr-in-Charge. |
| 140 | (b)Indicator suitable for window type AC up to 1.5Ton. |
| 141 | (c)Thermostat switch suitable for window type AC up to 1.5Ton. |
| 142 | (d) Control knob suitable for thermostat switch and selector switch ofwindow type AC up to 1.5Ton |
| 143 | (e) Selector switchsuitable for window type AC up to 1.5Ton |
| 144 | (f)Relay box suitable for window Type AC upto 1.5Ton. as on site. |
| 145 | (g) Plastic airfilter suitable for window AC upto 1.5Ton.as on site. |
| 146 | (h) Condenser fansuitable for window type AC up to 1.5Ton as on site. |
| 147 | (j)Fan for blower motor suitable for window type AC up to 1.5Ton. as on site. |
| 148 | (k) Front grill as per existing suitable for Window type AC upto 1.5Ton as on site. |
| 149 | (l)Hermetically uncut sealedcompressor unit receprocating type forwindow Type Air conditioner 1.5 Ton |
| 150 | Material and labour for System fusing, welding, soldering, brazing ,vaccumising , charging of refrigerant gas as per existing to window Type 1.5 Tonand leak testing complete all as specified and as directed |
| 151 | Rewinding transformer of voltage stabalizer of capacity 05 KVA with existing guage copper winding of capacity range 90 to 280 Volts complete all as specified and as directed. |
| 152 | Transporting unserviceable refrigerator of any capacity and make to ascertain the quantam of repairs involved display unserviceable spares / items for inspection of Engnr -in Charge. Assembling of refrigerator with serviceable parts and unserviceable parts to be replaced with new ones as ordered commissioningtesting for smooth operation and proper cooling effect complete all as specified and as directed.Notes: (a).Any Parts required for replacement, charging of gasrequired shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis deemed to be included in unit rate quoted against this Item. (b) Rate quated shall be deemed to be inclusive of transportion from Site to work shop & back after repair within permises.( c)Any unforeseen minor repair and minor parts that are not covered under Item but required to complete the repair work / smooth functioning of refrigeratorshalldeemed to be included in the rate quoted. |
| 153 | Supply only thefollowing Items to incorporate againstrelevant repairable summer appliances (refrigerator) item No 128here-in- before |
| 154 | (a).Auto defrost thermostat switch for refrigerator of capacity upto 310 Ltrs.as on site. |
| 155 | (b). Open type relay for refrigerator of capacity upto 310 Ltrs. as on site.. |
| 156 | (c). Over load protectorfor refrigerator of capacity upto 310 Ltrs. as on site. |
| 157 | (d)Hermetically uncut sealedcompressor unitfor refrigerator of capacity upto 310 Ltrs. as on site |
| 158 | Material and labour for System fusing, welding, soldering, brazing ,vaccumising , charging of refrigerant gas as per existingfor refrigerator of capacity upto 310 Ltrsand leak testing complete all as specified and as directed |
| 159 | Transporting unserviceable Deep freezer of any capacity andmake to ascertain the quantam of repairs involved display unserviceable spares / items for inspection of Engnr -in Charge. Assembling of deep freezer with serviceable parts and unserviceable parts to be replaced with new ones as ordered commissioningtesting for smooth operation and proper cooling effect complete all as specified and as directed. Notes:(a).Any Parts required for replacement, charging of gasrequired shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis deemed to beincluded in rate quoted against this Item. (b) Rate quated shall be deemed to be inclusive of transportion from Site to work shop & back after repair within permises.( c)Any unforeseen minor repair and minor parts that are not covered under Item but required to complete the repair work / smooth functioning of Deep freezer shalldeemed to be included in the rate quoted. |
| 160 | Supply only thefollowing Items to incorporate againstrelevant repairable summer appliances (Deep freezer) item No 131here-in- before |
| 161 | (a).Thermostat switch suitable for Deep freezer of capacity up to 500 Ltrs.as on site |
| 162 | (b). Open type relay for Deep freezer of capacity upto 500 Ltrs. as on site |
| 163 | (c). Over load protectorfor Deep freezer of capacity upto 500 Ltrs as on site |
| 164 | (d)Hermetically uncut sealedcompressor unitfor Deep Freezer capacity 310 Ltr |
| 165 | Material and labour for System fusing, welding, soldering, brazing ,vaccumising, charging of refrigerant gas as per existing for Deep freezer of capacity upto 500 Ltrsand leak testing complete all as specified and as directed |
| 166 | Transporting unserviceable water cooler of any capacity andmake to ascertain the quantam of repairs involved display unserviceable spares / items for inspection of Engnr -in Charge. Assembling of water cooler with serviceable parts and unserviceable parts to be replaced with new ones as ordered commissioningtesting for smooth operation and proper cooling effect complete all as specified and as directed. Note: (a).Any Parts required for replacement, charging of gasrequired shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis deemed to be included in rate quoted against this Item. (b) Rate quoted shall be inclusive of transportion from Site to work shop & back after repair within permises.( c)Any unforeseen minor repair and minor parts that are not covered under Item but required to complete the repair work / smooth functioning of water cooler shall bedeemed to be included with therate qouted. |
| 167 | Supply only thefollowing Items to incorporate againstrelevant repairable summer appliances (water cooler) items No 134here-in- before |
| 168 | (a).Relay suitable for water cooler capacity 40-80 Ltr , As on site. |
| 169 | (b).Over load protectorsuitable for water coolercapacity40-80 Ltr, As on site. |
| 170 | (c). Condenser fan motor single phase 230 Volt complete with fan suitablefor water cooler 40-80 LtrAs on site. |
| 171 | (d).Automatic thermostat switch suitable for water cooler40/80 LtrAs on site. |
| 172 | (e)Hermetically uncut sealedcompressor unitfor water cooler40/80 Ltr |
| 173 | Material and labour for System fusing, welding, soldering, brazing ,vaccumising , charging of refrigerant gas as per existing for Deep freezer of capacity upto 500 Ltrsand leak testing complete all as specified and as directed |
| 174 | S & F Energy saving new generation environmental friendly long life versatile LED street light in aluminium pressure die cast housing with toughened glass cover (IP66 rating)with high power LEDs as light source and electronic driver of capacity 30 watts, pre wired, necessary mounting arrangements including provision of 1.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required includingtaking down old unserviceable Street Light Fitting fixed at any height form existing location of any description complete all as specified and as directed. Make Jaquar Cat No LSRT01S030XW or equvalent in Syska, Philips as approved by GE. |
| 175 | S & F Energy saving new generation environmental friendly long life versatile LED street light in aluminium pressure die cast housing with toughened glass cover (IP66 rating)with high power LEDs as light source and electronic driver of capacity 36 watts, pre wired, necessary mounting arrangements including provision of 1.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required includingtaking down old unserviceable Street Light Fitting fixed at any height form existing location of any description complete all as specified and as directed. Make: Jaquar Cat No LSRT01S036XW or equvalent in Syska, Philips as approved by GE |
| 176 | S & F Energy saving new generation environmental friendly long life versatile LED street light in aluminium pressure die cast housing with toughened glass cover (IP66 rating)with high power LEDs as light source and electronic driver of capacity 45 watts, pre wired, necessary mounting arrangements including provision of 1.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required includingtaking down old unserviceable Street Light Fitting fixed at any height form existing location of any description complete all as specified and as directed.Make: Jaquar Cat No LSRT01S045XW or equvalent in Syska, Philips as approved by GE |
| 177 | S & F Energy saving new generation environmental friendly long life versatile LED street light in aluminium pressure die cast housing with toughened glass cover (IP66 rating)with high power LEDs as light source and electronic driver of capacity 60 watts, pre wired, necessary mounting arrangements including provision of 1.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required including necessary GI pipe medium grade, bracket 40 mm dia 1.5 mtr long bend to required shape and taking down old unserviceable Street Light Fitting fixed at any height form existing location of any description complete all as specified and as directed. Make: Jaquar Cat No LSRT01S060XW or equvalent in Syska, Philips as approved by GE |
| 178 | S & F Energy saving new generation environmental friendly long life versatile LED street light in aluminium pressure die cast housing with toughened glass cover (IP66 rating)with high power LEDs as light source and electronic driver of capacity 72 watts, pre wired, necessary mounting arrangements including provision of 1.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required including necessary GI pipe medium grade, bracket 40 mm dia 1.5 mtr long bend to required shape and taking down old unserviceable Street Light Fitting fixed at any height form existing location of any description complete all as specified and as directed. Make: Jaquar Cat No LSRT01S072XW or equvalent in Syska, Philips as approved by GE |
| 179 | S & F Energy saving new generation environmental friendly long life versatile LED street light in aluminium pressure die cast housing with toughened glass cover (IP66 rating)with high power LEDs as light source and electronic driver of capacity 90 watts, pre wired, necessary mounting arrangements including provision of 1.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required including necessary GI pipe medium grade, bracket 40 mm dia 1.5 mtr long bend to required shape and taking down old unserviceable Street Light Fitting fixed at any height form existing location of any description complete all as specified and as directed. Make: Jaquar Cat No LSRT01S090XW or equvalent in Syska, Philips |
| 180 | S & F LEDflood light luminariein aluminium high pressure die cast housingwith toughened glass cover & lens (IP65 rating), high power LEDs as light source and electronic driver of capacity50watts, pre wired, necessary mounting arrangements including provision of 2.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required and taking down old unserviceable flood Light Fitting fixed at any height form existing location of any description complete all as specified and as directed. Make: Jaquar Cat No LFLD02S050XW or equvalent in Syska, Philips as approved by GE |
| 181 | S & F LEDflood light luminariein aluminium high pressure die cast housingwith toughened glass cover & lens (IP65 rating), high power LEDs as light source and electronic driver of capacity70watts, pre wired, necessary mounting arrangements including provision of 2.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required and taking down old unserviceable flood Light Fitting fixed at any height form existing location of any description complete all as specified and as directed. Make: Jaquar Cat No LFLD02S070XW or equvalent in Syska, Philips as approved by GE |
| 182 | S & F LEDflood light luminariein aluminium high pressure die cast housingwith toughened glass cover & lens (IP65 rating), high power LEDs as light source and electronic driver of capacity90watts, pre wired, necessary mounting arrangements including provision of 2.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required and taking down old unserviceable flood Light Fitting fixed at any height form existing location of any description complete all as specified and as directed. Make: Jaquar Cat No LFLD02S090XW or equvalent in Syska, Philips as approved by GE |
| 183 | Supply and fixing land scape lighting LED post top with decorative circular design compliant to dark sky norms with polycarbonate opal diffuser and IP 65 protection 45 Watt fitting complete with3 Mtr pipe as in poleincluding provision of 1.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required and taking down old unserviceableLight Fitting fixedof any description complete all as specified and as directed. Make: BajajCat No BGCP 45W LED WW or equvalent in Jaquar, Syska, Philips as approved by GE |
| 184 | Supply and fixing land scape lighting bollard Aluminium die cast housing, opal white PC diffuser, IP54 with in-built LED,3 x 10 x 0.5Wattcomplete fittingincluding provision of 1.5 Sqmm twin core copper conductor cable multi stranded from fitting and other end connected to tapping point of length required and taking down old unserviceablebollard light Fitting fixedof any description complete all as specified and as directed. Make: Jaquar Cat No LBLD01R305XW or equvalent in Syska, Philips as approved by GE |
| 185 | Supply & erecting Hot-Dip Galvanized (HDG) Octagonal Poles for Street Lighting in single sectionof 4 Mtr. height ,Top – 70mm dia, Bottom – 130mm dia and 3mm thickness sheet. Base plate of minimum dimension 200mm X 200mm X 12 mm, includingfoundation bolts (4 nos with 3 nos of nuts and washers in each), with decorative single arm bracket for mounting the light fittings1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts etc, bakelite sheet with one 6A SP MCB andstud connector ( 4 Nos) inside the pole at door opening for cable connection,complete llas specified and as directed. NOTE : Earthwork, Cement Concrete for foundation , etc. will be measured and paid under approprite Items. Make:Bajaj Type BOP-4030 or Equivalent of make as per Appx \"A\" as approved by GE. |
| 186 | Supply & erecting Hot-Dip Galvanized (HDG) Octagonal Poles for Street Lighting in single sectionof 5 Mtr. height ,Top – 70mm dia, Bottom – 130mm dia and 3mm thickness sheet. Base plate of minimum dimension 200mm X 200mm X 12 mm, includingfoundation bolts (4 nos with 3 nos of nuts and washers in each), with decorative single arm bracket for mounting the light fittings1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts etc, bakelite sheet with one 6A SP MCB and 16 sqmm stud type connector ( 4 Nos) inside the pole at door opening for cable connection,complete all as specified and as directed. NOTE : Earthwork, Cement Concrete for foundation , etc. will be measured and paid under approprite Items.Make:Bajaj Type BOP-5030 or Equivalent of make as per Appx \"A\" as approved by GE. |
| 187 | Supply & erecting Hot-Dip Galvanized (HDG) Octagonal Poles for Street Lighting in single sectionof 6 Mtr. height ,Top – 70mm dia, Bottom – 130mm dia and 3mm thickness sheet. Base plate of minimum dimension 200mm X 200mm X 12 mm, includingfoundation bolts (4 nos with 3 nos of nuts and washers in each), with decorative single arm bracket for mounting the light fittings1000 mm long, bent at an angle of 120 degree, with necessary holding brackets, hold fasts etc, bakelite sheet with one 6A SP MCB andstudconnector ( 4 nos) inside the pole at door opening for cable connection,complete all as specified and as directed NOTE : Earthwork, Cement Concrete for foundation , etc. will be measured and paid under approprite Items.Make -Bajaj Type BOP-6030 or Equivalent of make as per Appx \"A\" as approved by GE. |
| 188 | S & FRectangular pole mountedcable junction box suitablefor 3 Phase 440 Volt , 20 Amps of size 200 x140x 95 mm ( IP 55 Protection)made out of SMC sheet 5 mm thickness, cable entry at botton, left hinged door, with & includingPVC Bus bar Terminal connection plate for cable connection, SP MCB 6 Amps, andMS clamps to secure box with pole , complete all as specified and as directed.Make: Sintex or Equivalent of make as per Appx A as apptroved by GE. |
| 189 | S&F Surface Mounting Time Switch 240 Volt, 50 Hz, 16-20 Amp rating and connecting with contactor with cable terminations including taking down old unserviceable Time Switch, complete all as specified and as directed.Make Legrand Cat No 4127 94 or Equivalent of make as per Appx A as apptroved by GE |
| 190 | S & F Contactor for Street Light Time Switch Type 3 pole contactors,40 Amp, 415 Volt, including taking down old unserviceable Contactor, complete all as specified and as directed |
| 191 | M&L for taking down LED Light Fitting of any Watt/Make, repairing the same by opening Cover, re-wiring the Light Fitting with existing size Copper Conductor Cable, multi-stranded, replacing unserviceable Parts as required/ ordered, refixing Light Fitting in Original Position after repaired and connecting up, complete all as specified and as directed.NOTE :– (a)Spare Parts such as LED driver etc.required will be measured and paid under appropriate Item(s) as ‘Supply only’.(b)Labour Element for replacement of unserviceable Parts is deemed to be included in the Quoted Unit Rate. |
| 192 | Supply only thefollowing Items to incorporate againstrelevant repairable (street lights) item No 151here-in- before |
| 193 | (a) LED Driver (as approved) for 18 WattRoad Way Lighting Luminaires Voltage Tapping at 230/240 Volt, |
| 194 | (b) LED Driver (as approved) for 24 WattRoad Way Lighting Luminaires Voltage Tapping at 230/240 Volt, |
| 195 | (c) LED Driver (as approved) for 36 WattRoad Way Lighting Luminaires Voltage Tapping at 230/240 Volt, |
| 196 | (d) LED Driver (as approved) for 45 WattRoad Way Lighting Luminaires Voltage Tapping at 230/240 Volt, |
| 197 | Taking down carefully existing unserviceable aluminium/copper point wiring (light, fan, sockets or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials from site and making good disturbed surfaces of walls, floors, ceilings all as specified and as directed. |
| 198 | M & L for point wiring complete with and including single core PVC FRLS insulated unsheathed flexible multistaranded copper conductor cables 1.5 Sqmm (22/0.30mm) 1100 Volts grade drawn through and including heavy grade PVC rigid conduits 20mm or higher dia as reqd at site totally concealed in walls / floors/ ceilings including all conduit accessories / fittings/junction boxes/ inspection covers etc of heavy grade, ISI marked and sunken terminal boxes of factory made 16 SWG pressed steel housing , totally concealed in walls covered with modular white colour cover plate with inner frame suitable to modular switch and sockets, fan regulators etc. including 1.5 Sqmm (22/0.30m) 1100 Volt grade FRLS, PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earth wire connected to metallic bodies of luminaires/ fans etc. at one end and to common earth dolly at other end all as specified , directedfor:- |
| 199 | (a)One light point controlled by one, one way switch 6 Amps |
| 200 | (b)One fan point / exhaust fan pointcontrolled by one, one way switch 6 Amps and regulator |
| 201 | (c)One 5 pin 6 Amps switch socket outlet point controlledby one,switch on independent board |
| 202 | (d)One bell point controlled by one, bell switch 6 Amps |
| 203 | (e)One 5 pin 6 Amps switch socket outlet point controlled by one switch on same board |
| 204 | Description all as per 157 here-in before but using 2.5 Sqmm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 /16 ampssocketcombination point including necessary running of 2.5 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to common earth dollyall as specified and as directed. |
| 205 | M & L for point wiring completewith and including single core PVC FRLS insulated unsheathed flexible multistaranded copper conductor cables 1.5 Sqmm (22/0.30mm) 1100 Volts grade drawn through and including heavy grade PVC casing caping as reqd at site surface mounted on walls / ceilings including allaccessories ISI marked and sunken terminal boxes of factory made 16 SWG pressed steel housing , totally concealed in walls covered with modular white colour cover plate with inner frame suitable to modular switch and sockets, fan regulators etc. including 1.5 Sqmm (22/0.30m) 1100 Volt grade FRLS, PVC insulated, unsheathed flexible multi stranded copper conductor cable as continuous earth wire connected to metallic bodies of luminaires/ fans etc. at one end and to common earth dolly at other end all as specified , directedfor:- |
| 206 | (a)One light point controlled by one, one way switch 6 Amps |
| 207 | (b)One fan point / exhaust fan pointcontrolled by one, one way switch 6 Amps and regulator |
| 208 | (c)One 5 pin 6 Amps switch socket outlet point controlledby one,switch on independent board |
| 209 | (d)One bell point controlled by one, bell switch 6 Amps |
| 210 | (e)One 5 pin 6 Amps switch socket outlet point controlled by one switch on same board |
| 211 | Description all as per 1 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 /16 ampssocket socket combination point including necessary running of 2.5 Sqmm PVC insulatedmultistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to common earth dolly complete all as specified andas directed. |
| 212 | Supply and fixingModular switch piano flush type, one way 6A, single module complete all as specified andas directed. |
| 213 | Supply and fixingModular switch piano flush type, oneway 16A, one module complete all as specified andas directed. |
| 214 | Supply and fixing Modular Bell push 6A ,one module complete all as specified andas directed. |
| 215 | Supply and fixing Modular socket outlet multipurpose, 6A -5 pin combined 2 module,complete all as specified andas directed. |
| 216 | Supply and fixing Modular socket outlet multipurpose,6A/16A - 3 pin 16 A, and 3 pin 6 Amps combined two module, complete all as specified andas directed. |
| 217 | Supply and fixing modular stepped type electronic fan regulator flush type, 120W - 2 module suitable for 230V 50Hz AC supply complete all as specified andas directed. |
| 218 | Supply and fixing in repair switch piano flush type, one way 6A, complete all as specified andas directed. |
| 219 | Supply and fixing in repair switch piano flush type, two way 6A,complete all as specified andas directed. |
| 220 | Supply and fixing in repair Bell push 6A , flush typecomplete all as specified andas directed. |
| 221 | Supply and fixing in repair switch piano flush type, oneway 16A,complete all as specified andas directed. |
| 222 | Supply and fixing in repair socket outlet multipurpose, 6 A - 5 pincomplete all as specified andas directed. |
| 223 | Supply and fixing in repair socket outlet multipurpose, 6A/16A-6 Pin complete all as specified andas directed. |
| 224 | Supply and fixing in repair stepped type electronic fan regulator flush type, suitable for 230V 50Hz AC supply complete all as specified andas directed. |
| 225 | S& F ceiling rose surface type PVC 50 mm dia 3 terminals including PVC mounting block, White/Ivoryfinish,ISImarked complete all as specified and as directed. |
| 226 | S & F in repair Bell ding dong,single pole type suitable for operation on AC. 230 volts, 50 Hz AC supply complete all as specified andas directed.. |
| 227 | M & L lamp holder, (Angle/ bracket), PVC/ Polycarbonate type insulated body with back plate of brass terminal suitable for batten fittings complete all as specified andas directed. |
| 228 | Supply and fixing 22 Watt high quality PC design Glaze LED Batten with decorative end caps light fitting230 Volts withintregrated electronic driver connector block etc complete with all accessories prewired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed.Make- Jaquar Cat No-LGLZPCX022XW or equivalent of make as per Appx \"A\" as approved by GE. |
| 229 | Supply and fixing 10 Watt LED high quality designPC Batten aluminium extruded with decorative end caps light fitting230 Volts withintregrated electronic driver connector block etc complete with all accessories prewired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. Make- Jaquar Cat No-LGLZ01X010XW or equivalent of make as per Appx \"A\" as approved by GE |
| 230 | S & F Energy saving new generation 10 Watts LED bulk head fitting IP 65 Luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including necessary LED bulb 10 Watt complete all as specified and as directed |
| 231 | S & F downlights LED recess-mounted designer panel round with aluminium die cast housing 12W Cutout: Ø141mm including necessary LED bulbcomplete all as specified and as directedMake- Jaquar Cat No-LNRO01R012XW or equivalent of make as per Appx \"A\" as approved by GE |
| 232 | S & F Ultra slim LED panel made from extruded aluminium housing frame (recess / pendant) 2ft x 2ft, 40 Wattincluding necessary LED tube complete all as specified and as directed. Make- Jaquar Cat No-LSVR01S040XC or equivalent of make as per Appx \"A\" as approved by GE. |
| 233 | Fixing only serviceable ceiling rose, obtained from item No 156 here-in-before complete all as specified andas directed. |
| 234 | Supply only Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/ CFL/LEDdirect fit lamp, in B-22 cap complete all as specified and as directed |
| 235 | Taking down carefully existing unserviceable main switch /cutout /DBs of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, floors as per the existing finishes all as specified and as directed. |
| 236 | S&F Distribution board sheet metal enclosure double door, factory made fixed flush with wall inside niches for mounting MCBs 230 Volts with 200 amps ratedbus bars with front openable cover singlepole and neutral 4 way consumer unit complete all as specified and as directed |
| 237 | S&F Distribution board sheet metal enclosure double door, factory made fixed flush with wall inside niches for mounting MCBs 230 Volts with 200 amps ratedbus bars with front openable cover singlepole and neutral 8 way consumer unit complete all as specified and as directed |
| 238 | S&F Distribution board sheet metal enclosure double door, factory made fixed flush with wall inside niches for mounting MCBs 230 Volts with 200 amps ratedbus bars with front openable cover singlepole and neutral 12 way consumer unit complete all as specified and as directed |
| 239 | S & F sheet metal enclosure MCB DB TPN 4 way vertical type with 200 Amps rated bus bar 415 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed. |
| 240 | S & F TPN phase segregated vertical type 4 way 415 volts, 50 Hz distribution board double door, factory made fixed flush with wall inside niches suitable for MCCB incomer 415 Volts, IP 43 protection & for mounting MCBs230 Volts making electrical connections complete all as specified and as directed. |
| 241 | Supplied & fixedSingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V 20 Amps complete all as specified and as directed |
| 242 | Supplied & fixedSingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V 10 Amps complete all as specified and as directed |
| 243 | S& F MCB single polerated capacity 5 to 32 A, 240V breaking capacity 10 KA \"C\" series complete all as specified and as directed |
| 244 | S& F MCB single pole rated capacity 40 to 63 A, 240V breaking capacity 10 KA \"C\" series complete all as specified and as directed |
| 245 | S& F MCB single pole and neutral rated capacity 6 to 32 A, 240V breaking capacity 10 KA \"C\" series complete all as specified and as directed |
| 246 | S& F MCB tripple pole and neutral rated capacity16 to 32 A, 415 V breaking capacity 10 KA \"C\" series complete all as specified and as directed |
| 247 | S& F MCB tripple pole and neutral rated capacity40 to 63 A, 415 V breaking capacity 10 KA \"C\" series complete all as specified and as directed |
| 248 | Taking down carefully existing unserviceable sub main wiring of any type, capacity and description and removing materials from site and making good disturbed surfaces of walls, ceiling and floors as per the existing finishes all as specified and as directed. |
| 249 | S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 4.0 Sqmm and one single core 4.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , drawn through in existing surface recessed steel / PVC conductand conduit accessories complete all as specified andas directed. |
| 250 | S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 6.0 Sqmm and one single core 6.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead ,drawn through in existing surface recessed steel / PVC conductand conduit accessories complete all as specified andas directed. Note for item No- 198 & 199 above:- ( Two runs of main copper wire, one run of earth wire cableshall be measured together as one length). |
| 251 | M & L for submain wiring with approved colour coding with Two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sqmm nominal area and drawing into concealedPVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable sizeafter chasing in walls etc with one run of PVC insulated multistranded copper conductor 4.0Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly all as specified and as directed. |
| 252 | M & L for submain wiring with approved colour coding with Two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqmm nominal area and drawing into concealedPVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable sizeafter chasing in walls etc with one run of PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly all as specified and as directed. Note for item No 200 & 201:( Two runs of main copper wire, one run of earth wire cable & PVC conduit shall be measured together as one length). |
| 253 | M & L for submain wiring with approved colour coding with four single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqmm nominal area and drawing into concealedPVC non metallic rigid heavy duty conduit and its accessories (ISI marked) of suitable sizeafter chasing in walls etc with two runs of PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly all as specified and as directed.Note- Four run of 6 Sqmm, one run of 6 Sqmmcable and one run of PVC conduit will be measured as one unit complete all as specified and as directed |
| 254 | M & L for submain wiring with approved colour codingwith Two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sqmm nominal area and drawing in & including PVC rigid heavy duty casing caping and its accessories (ISI marked) of suitable size with one run of PVC insulated multistranded copper conductor 4 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly all as specified and as directed. |
| 255 | M & L for submain wiring with approved colour coding with Two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqmm nominal area and drawing in & including PVC rigid heavy duty casing caping and its accessories (ISI marked) of suitable size with one run of PVC insulated multistranded copper conductor 6 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with submain wiring and connecting to earth dolly all as specified and as directed.Note for item No 203 & 204 above:- ( Two runs of main copper wire, one run of earth wire cable & PVC casing caping shall be measured together as one length). |
| 256 | Servicing / over hauling of ceiling fan 230 Volts of any make and sweep, along with following other repairs:-a). Dismantaling of ceiling fan complete part by part carefully, testing stator coils, degreasing bearingand display all the parts without damaging any portion for inspection of Engineer-in- Charge to ascertain the serviceability of existing parts.b)Heating & varnishingto stator coils with super quality varnish and dried out properely with external heat as ordered & directed.c) Reassembeling of ceiling fan complete with all existingserviceable parts obtained against Item 1 (a), greasing the bearing with bearing grease , andnew parts as required / ordered by Engineer in Charge. |
| 257 | Note (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as \"\"Supply only\"\" (s) of this schedule. However labour element involved in replacementis deemed to beincluded in quoted rate quoated against this Item.(ii).Any unforeseen minor repair and minor parts that are not covered under Item No-1 , (a) to (c) ( Total cost less than Rs 150 ) but required to complete the repair work / smooth functioning of fanshallbe deemed to be included with the qouted rate. (iii) Transportation of fan to workshop for repair and back to site in EM store yard at Kolhapur is deemed to be included with quoted rate.(iii). Rewinding of stator coils of ceiling fan , where involved shall be measured and paid separetely against relevant item of this schedule. |
| 258 | Supply only thefollowing Items to incorporate againstrelevant ceiling fans items No 205here-in- before. |
| 259 | (a)Ball bearing for bottom cover6201 or as per existing |
| 260 | (b)Ball bearing for bottom cover6202 or as per existing |
| 261 | (c) Shaft of Rotorfor ceiling fan 1200/1400 mm sweep as per existing. |
| 262 | M & L in replacement of ceiling fan capacitor 2.5 MFD with or without taking down the ceiling fan fixed at any heightrefixing in original Position after repaired and connecting up, complete all as specified and as directed. |
| 263 | Material and labour for rewinding stator of ceiling fan1200 mm sweep with supper enameled copper wire of existing gauge, and testing complete all as specified and as directed. |
| 264 | Material and labour for rewinding stator of ceiling fan1400 mm sweep with supper enameled copper wire of existing gauge, and testing complete all as specified and as directed. |
| 265 | M& L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick,buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level),connected to and including GI strip 5×4 mm as earthing lead by means of bolts, nuts & checknuts and washers of galvanized iron or steeldrawn through GI pipe40 mm dia medium grade pipe for protection of G.I earth strip, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit withprecast RCC cover in CC 1:2:4 type B1with handle , with G.I 20 mm dia medium grade pipefor watering and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed. |
| 266 | M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick,buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level),connected to and including galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & check nuts and washers etc;GI pipe15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of strata & testing on completion complete all as specified and as directed. Note for Item No 210 & 211: Quoted rate deemed to includes cost of dismantling unserviceable earthing pit above ground level with earthing electrode and making good existing ground. |
| 267 | Note : 1. Rerformance security:- Refer Condition 22 of Special Conditions 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. |