Department Of Tourism has published Repair / Renovation By Way Of Electrification At Adt Quarter At Rajouri Repair / Renovation By Way Of Electrification At Adt Quarter At Rajouri. Submission Date for this Tender is 04-10-2021. Electrification Work Tenders in Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLs PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate suitable G.I box and earthing the point with 1.5 sq.mm FRLs PVC insulated copper conductor single core cable of superior quality as per the approval of Engineer-in-charge. |
2 | Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLs PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate suitable G.I box and earthing the point with 1.5 sq.mm FRLs PVC insulated copper conductor single core cable of superior quality as per the approval of Engineer-in-charge. |
3 | Group A |
4 | Group B |
5 | Group C |
6 | Wiring for circuit/sub main wiring alongwith earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of superior quality as per the approval of Engineer-in-charge. |
7 | 2x1.5 sq.mm + 1x1.5 sq.mm earthwire |
8 | 2x2.5 sq.mm + 1x2.5 sq.mm earthwire |
9 | 2x4 sq.mm + 1x4 sq.mm earthwire |
10 | Supplying and fixing following size/module, GI box alongwith modular base and cover plate for modular switches in recess etc. as required Make Havells, Legrand, Anchor roma,Syska,Biocon |
11 | 4 module (125mm x 75mm) |
12 | 12 Module (200mm x 150mm) |
13 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as reqd. of superior quality as per the approval of Engineer-in-charge. |
14 | 4 module |
15 | 12 Module |
16 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as reqd. of superior quality as per the approval of Engineer-in-charge. |
17 | Supplying and fixing 5A to 32A rating, 240/415 A, 10 KA, C curve, miniature circuit breakes suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make Havells, L&T, C&S,Syaka , Biocon |
18 | Single pole |
19 | Single pole and neutral |
20 | Supplying and fixing following rating, double pole, 415 V, isolater in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. of superior quality as per the approval of Engineer-in-charge. |
21 | 63 A |
22 | Supplying and fixing following modular switch/ socket on the existing switch box/cover incld. connections etc. as reqd. of superior quality as per the approval of Engineer-in-charge. |
23 | 5/6 A, Switch |
24 | 15/16 A, Switch |
25 | 3 pin, 5/6 A socket outlet |
26 | 6 pin, 15/16A socket outlet |
27 | Supplying and fixing two module stepped type electronic fan, regulator on the existing modular plate, switch box including connections but excld. modular plate etc.of superior quality as per the approval of Engineer-in-charge. |
28 | Supply, Installation, testing and commissioning of Ceiling Fans 48"inch fitting with extended pipe of 2-5 ft. as per requirement on site of superior quality as per the approval of Engineer-in-charge. |
29 | Supply, testing and commissioninng of 20 w, 220 V, wall mounted electronic LED tube of superior quality as per the approval of Engineer-in-charge. |
30 | Supply and fixiing of Slim surface /Recess LED flat panel light made extruded aluminium frame with high efficient LED and glass free opal diffuser of superior quality as per the approval of Engineer-in-charge. |
31 | 22 W |
32 | 5 W |
33 | Supply, testing and commissioning of 225 mm Heavy Duity Exhaust Fan of superior quality as per the approval of Engineer-in-charge. |
34 | Supplying and drawing following sizes of FRLS PVC insulated 2 core 10 sq mm armoured Aluminium conductorein 0.75 mtr wide and 1 mtr deep trench by way of digging and filling it back with mud upto ground levelfor the larying of cable by way of crimping of cable and attaching thimbles of Appropriate size. Job includes laying of cable in PVC conduit of appropriate size of superior quality as per the approval of Engineer-in-charge. |
35 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V on surface/recess complete with finned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted incld. earthing etc. as reqd.of superior quality as per the approval of Engineer-in-charge. |
36 | 4 way (4+12), Double door |
37 | Supply , testing , commissioning and installation of 1 KW sineware invertor with trolley of superior quality as per the approval of Engineer-in-charge. |
38 | Batteries (12 volt 200 Amp) with 3 years warranty of superior quality as per the approval of Engineer-in-charge. |
39 | Servicing of Air Conditioner by way of cleaning, outdoor compressor and internal net of indoor unit as per the instructions of Engineer incharge. |
40 | Repair of Air Conditioner by way of refilling of gas and replacing all necessery faulty electronic items, wiring and repair of leaks in outdoor compressor and indoor unit as per the instructions of Engineer incharge. |
41 | Supply, Testing , Fixing and Commissioning of copper wound wall mounted 5 KWtransformer of range 90-260v for presently installed 2 TR Air Conditioner of superior quality as per the approval of Engineer-in-charge. |
42 | Supply, Testing , Fixing and Commissioning of 25 litres vvirtual storage water heaters including all plumbing work and connecting pipes of superior quality as per the approval of Engineer-in-charge. |
43 | Supply, testing, fixing and commissioning of 1 H.P. moter will all necessary electrical connections/Plug andplumbing work of superior quality as per the approval of Engineer-in-charge. |