| 1 | Supply,laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and lenght of calbe shall be one length unless otherwise as directed by GE) |
| 2 | Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and lenght of calbe shall be one length unless otherwise as directed by GE) |
| 3 | Supply,laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and lenght of calbe shall be one length unless otherwise as directed by GE) |
| 4 | Supply,laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and lenght of calbe shall be one length unless otherwise as directed by GE) |
| 5 | Supply,laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and lenght of calbe shall be one length unless otherwise as directed by GE) |
| 6 | Supply,laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and lenght of calbe shall be one length unless otherwise as directed by GE) |
| 7 | Supply,laying, jointng and testing,XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and lenght of calbe shall be one length unless otherwise as directed by GE) |
| 8 | Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and lenght of calbe shall be one length unless otherwise as directed by GE) |
| 9 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed. |
| 10 | M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed.(Note: Punned thickness of sand shall be measured and paid). |
| 11 | Supplying and laying reinforced precast concrete cable cover, class LV, type 1 flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 12 | Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. |
| 13 | Removing of excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. |
| 14 | M&L for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection complete as in repairall as specified and directed. |
| 15 | M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground levelconnected to and including 25X4mm thick galvanised iron strip by means ofbolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed.(Note:-Earth strip and protection pipe upto board is included in the rate quoted) |
| 16 | M&L for painting to LT Prestressed concrete poles of size 9mtr long with two coats of acrylic emulsion paint over a coat of primer including making alternats strips each of 30 cm height with black and yellow synthetic enamel paint upto 1.20 mtr height from top of PCC coping complete all as specified and directed. |
| 17 | Tightening of existing ACSR conductor on LT overhead line of any size and type of span of 1x5 Nos of conductor wires, length 40 to 50mtr approximate of each span including 1run of GI earth wire 4mm dia and including making the jumpher connections and including cutting, trimming tree branches of various length on both sides to keep a clear distance 2 mtr from the pole anddepositing the cut branches upto 50 mtr from the pole including taking shut down in writing with all safety measure as per electric rule complete all as directed by the Engineer-in-Charge.(Note :- Materials/T&P like Axes, rope, gloves etc. and the like will be provided by the contractor without any extra cost) |
| 18 | Supply , install, testing and commissioning of factory made outdoor type floor mounted LT panel board of size 1800mmx1500mmx450mm cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber (aluminium TPN 400 amps rating) with airinsulated PVC sleeved copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.2 mm CRCAsheet and 50 X 50 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process on both sides with PCC (1:2:4) foundation, type B-1 using 20mm graded stone aggregates including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm and comprising of followings components after taking down old unserviceable panel with all fittings and fixtures:-(a) MCCB 250 Amp 4 Pole 50 Hz 415 V having rupturing capacity 35 KA-01 No as incoming (thermal magnetic) release and adjustable on load (b) MCCB 100 Amp 4 Pole 50 Hz 415 V having rupturing capacity 25 KA-02 Nos as incoming (thermal magnetic) release and adjustable on load (c) MCCB 63 Amp 4 Pole, 50 Hz, 415 hanving rupturing capacity 16 KA-04 Nos as out going (thermal magnetic) release and adjustable on load(d) MCB, SP, 40Amps, 50 Hz, 415 Volt, \"C\" curve/series, having rupturing capacity 10KA-2 Nos as outgoing (e) Indicator set RYB 01 set of 3 pcs LED type - 1 set (f) Digital voltmeter of size 96x96 mm range 30 to 600 volts with in built in selector switch with CT\"s -01 set (g) Digital ammeter of size 96 x96 mm range 0 to 100 Amps with in built in selector switch complete with CTs of appropriate ratio- 01 Set (h) Aluminium bus bar, TPN, 400 Amp rating-01 set Notes : (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 Nos legs of 50mm x 50mmx6mm for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclouser made up of 3.2mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make and submit CPRI certificate before payment duly defaced and verified by the Engineer-in-Charge and contractor (v) Make of panel and drawing shall be got approved from GE before placing order for procurement |
| 19 | Supply , install, testing and commissioning of factory made outdoor type floor mounted LT panel board of size 1800mmx1500mmx450mm cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber (aluminium TPN 400 amps rating) with airinsulated PVC sleeved copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.2 mm CRCAsheet and 50 X 50 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process on both sides with PCC (1:2:4) foundation, type B-1 using 20mm graded stone aggregates including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm and comprising of followings components after taking down old unserviceable panel with all fittings and fixtures:-(a) MCCB 250 Amp 4 Pole 50 Hz 415 V having rupturing capacity 35 KA-01 No as incoming (thermal magnetic) release and adjustable on load (b) MCCB 100 Amp 4 Pole 50 Hz 415 V having rupturing capacity 25 KA-02 Nos as incoming (thermal magnetic) release and adjustable on load (c) MCCB 63 Amp 4 Pole, 50 Hz, 415 hanving rupturing capacity 16 KA-03 Nos as out going (thermal magnetic) release and adjustable on load(d) Indicator set RYB 01 set of 3 pcs LED type - 1 set (e) Digital voltmeter of size 96x96 mm range 30 to 600 volts with in built in selector switch with CT\"s -01 set (f) Digital ammeter of size 96 x96 mm range 0 to 100 Amps with in built in selector switch complete with CTs of appropriate ratio- 01 Set (g) Aluminium bus bar, TPN, 400 Amp rating-01 set Notes : (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 Nos legs of 50mm x 50mmx6mm for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclouser made up of 3.2mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make and submit CPRI certificate before payment duly defaced and verified by the Engineer-in-Charge and contractor.(v) Make of panel and drawing shall be got approved from GE before placing order for procurement |
| 20 | Supply , install, testing and commissioning of factory made outdoor type floor mounted LT panel board of size 1800mmx1500mmx450mm cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber (aluminium TPN 400 amps rating) with airinsulated PVC sleeved copper bus bar of rating 400 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.2 mm CRCAsheet and 50 X 50 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process on both sides with PCC (1:2:4) foundation, type B-1 using 20mm graded stone aggregates including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleevedcopper strips of appropriate size but not less than 4.0 sq mm and comprising of followings components after taking down old unserviceable panel with all fittings and fixtures:-(a) MCCB 250 Amp 4 Pole 50 Hz 415 V having rupturing capacity 35 KA-01 No as incoming (thermal magnetic) release and adjustable on load (b) MCCB 100 Amp 4 Pole 50 Hz 415 V having rupturing capacity 25 KA-03 Nos as incoming (thermal magnetic) release and adjustable on load (c) MCB, 4 pole, 63Amps, 50 Hz, 415 Volt, \"C\" curve/series, having rupturing capacity 10KA-2 Nos as outgoing (d) Indicator set RYB 01 set of 3 pcs LED type - 1 set (e) Digital voltmeter of size 96x96 mm range 30 to 600 volts with in built in selector switch with CT\"s -01 set (f) Digital ammeter of size 96 x96 mm range 0 to 100 Amps with in built in selector switch complete with CTs of appropriate ratio- 01 Set (g) Aluminium bus bar, TPN, 400 Amp rating-01 set Notes : (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 Nos legs of 50mm x 50mmx6mm for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclouser made up of 3.2mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make and submit CPRI certificate before payment duly defaced and verified by the Engineer-in-Charge and contractor.(v) Make of panel and drawing shall be got approved from GE before placing order for procurement |
| 21 | S&F for change over switch, 4 pole, 415 Volts of rating 250 Amps, 3 phase, 50 Hz, side handle operated type, on load type in sheet metal enclouser of 2mm thick CRCA sheet, powder coated wheather proof fixed on mild steel angle iron of size 40mm x 40mm x 5mm duly painted and mounted above ground level with necessary PCC foundation (1:2:4), type B-1 (20mm graded stone aggregate), connected to incoming and outgoing cables with suitable lugs, glands, nuts, bolts, and washers etc complete as in repair all as specified and directed. |
| 22 | S&F for change over switch, 4 pole, 415 Volts of rating 400Amps, 3 phase, 50 Hz, side handle operated type, on load type in sheet metal enclouser of 2mm thick CRCA sheet, powder coated wheather proof fixed on mild steel angle iron of size 40mm x 40mm x 5mm duly painted and mounted above ground level with necessary PCC foundation (1:2:4), type B-1 (20mm graded stone aggregate), connected to incoming and outgoing cables with suitable lugs, glands, nuts, bolts, and washers etc complete as in repair all as specified and directed. |
| 23 | Complete removal of existing paint from the steel tubular swaged pole of 11 mtr height without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamel paint upt 1.50mtr height having alternative white and yellow strips of 30cm height each, including one coat of aluminium paint to the remaining part of pole (i.e above 1.50 mtr height) and its corss arms bracing, support and all steel members complete etc all as specified and directed. |
| 24 | Complete removal of existing paint from the steel tubular swaged pole of 9 mtr height without removing accessories and preparation of surfaces for repainting the poles with and including two coats of synthetic enamel paint upt 1.50mtr height having alternative white and yellow strips of 30cm height each, including one coat of aluminium paint to the remaining part of pole (i.e above 1.50 mtr height) and its corss arms bracing, support and all steel members complete etc all as specified and directed. |
| 25 | Cutting/trimming of tree branches under OH HT electric line including cleaning upto 2.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers small bushes etc of under OH line upto 60 mtr each sapn and depositing the cut branches upto 50mtr from the pole including taking shut down in writing with all safety measure as per electric rules complete all as directed by Engineer-in-Charge.(Note :- Materials/T&P like Axes, rope, gloves etc. and the like will be provided by the contractor without any extra cost ) |
| 26 | S&F for MCCB 63 Amps four pole adjustable thermal and magnetic setting type,16 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete as in repair all as specified and directed. |
| 27 | S&F for MCCB 100 Amps four pole adjustable thermal and magnetic setting type,16 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete as in repair all as specified and directed. |
| 28 | S&F for MCCB 160 Amps four pole adjustable thermal and magnetic setting type,25 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete as in repair all as specified and directed. |
| 29 | S&F for MCCB 200 Amps four pole adjustable thermal and magnetic setting type,35 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete as in repair all as specified and directed. |
| 30 | S&F for MCB 63 Amps four pole adjustable thermal and magnetic setting type,10 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCB any make and provision of suitable size of lugs for existing cable complete as in repair all as specified and directed. |
| 31 | S&F for MCB 40 Amps four pole adjustable thermal and magnetic setting type,10 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCB any make and provision of suitable size of lugs for existing cable complete as in repair all as specified and directed. |
| 32 | M&L for steel tubular swaged poles errected to truly vertical position with 6mm thick mild steel base plate of size 300mm x300mm, welded to Pole, B-118 finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II, type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide at 300mm spacing alternately and marking pole number. with black paint at suitable height including taking down old unserviceable broken steel pole of 9 mtr long complete all as specified and directed.(Note :- Necessary excavation of earth work, removing, returning filling in, PCC foundations of poles, coping etc shall be measured and paid separately) |
| 33 | M&L for PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete of poles and stay/installation paths complete all as specified and directed. |
| 34 | M&L for plain cement concrete type B-1 , 1:2:4 (using 20mm graded stone aggregate) as in coping, benching, hold fasts, water troughs, bed block and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 35 | S&F for LED street light fitting 36 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed(Make:- Crompton, Model No FREEDOM NEO LSTS-36-CDL-M or Havells, Cat No ENDURA PEARL NEO SL36WLED757PASYTOPC) |
| 36 | S&F for LED street light fitting 40 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed(Make:- Crompton, Model No FREEDOM NEO LSTS-40-CDL-M or Havells, Cat No ENDURA PEARL NEO SL40WLED757PASYTOPC) |
| 37 | S&F for LED street light fitting 45 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed(Make:- Crompton, Model No FREEDOM NEO LSTS-45-CDL-M or Havells, Cat No ENDURA PEARL NEO SL45WLED757PASYTOPC) |
| 38 | S&F for LED street light fitting 90 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 66 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fitting of any type complete all as specified and directed.(Make:- Crompton, Model No. NEXUS NEO,LSTP-90-CDL-HPM or Havells Cat No. ENDURA PEARLPLUSSL90WLED757PASYTOPCASTHO) |
| 39 | M&L for GI bracket pipe of size 25mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for streetstreet light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clams 2 Nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts and washers and after taking down old unserviceable GI brakcet of any type complete all as specified and directed. |
| 40 | S&F for FRP looping box of size 250x200x105mm with connector and comprising oF MCB SP 6 Amps, ISI marked 240 V, \"C\" series/curves complete with including providing GI calmps, nuts bolts etc suitable for fixing on PCC pole/wall etc and after taking down old unserviceable looping box of any type complete all as specified and directed. Make:- Hensel/Sintex |
| 41 | S&F for 120 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc at any height providing clamps, nuts, bolts, and washers etc after taking down old unserviceable flood light fitting of any type complete all as specified and directed. (Make:- Crompton, Model No PLUTO NEO LFTN-120-CDL/60-M or Havelles Cat No. JETAIRISFLS120WLED757SYMLTG) |
| 42 | S&F for 150 watt LED flood light luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium of IP-66 protection complete with all accessories duly prewired and including fixing arrangement on high mast poles/wall surfaces etc at any height providing clamps, nuts, bolts, and washers etc after taking down old unserviceable flood light fitting of any type complete all as specified and directed. (Make:- Crompton, Model No PLUTO NEO LFTN-150-CDL/60-M or Havelles Cat No. JETAIRISFLS150WLED757PSYMLTG) |
| 43 | S&F for copper conductor cable, PVC insulated, sheathed flexible, multistranded ISI marked 1100 volts grade 3 core 1.5 sqmm and including connection and testing and after taking down old unserviceable copper conductor cable complete all as specified and directed. |
| 44 | M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion after dismantling of old unserviceable earthing with material etc. complete all as specified and directed. |
| 45 | S&F for rigid Non metallic PVC conduit of 25mm dia (medium grade) including conduit accessories for encasing the cable from looping box to streel light fittings on PCC poles/on wall surfaces as per site requirement with necessary base saddles etc. all as specified and directed |
| 46 | Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents. |