Special Repair Replacement Of Ber Ceiling Fans At Nad And Mo Goa Provision Of Standby Lt Cable From Hq Gna Substation To Seaview And Bayview Of Gomantak And Certain Minor Works Under Ge Gomantak Special Repair Replacement Of Ber Ceiling Fans At Nad And Mo, VASCO DA GAMA-Goa

Military Engineer Services-MES has published Special Repair Replacement Of Ber Ceiling Fans At Nad And Mo Goa Provision Of Standby Lt Cable From Hq Gna Substation To Seaview And Bayview Of Gomantak And Certain Minor Works Under Ge Gomantak Special Repair Replacement Of Ber Ceiling Fans At Nad And Mo. Submission Date for this Tender is 19-10-2021. LT Cable Tenders in VASCO DA GAMA Goa. Bidders can get complete Tender details and download the document.




Tender Notice

29305951
Corrigendum : Special Repair Replacement Of Ber Ceiling Fans At Nad And Mo Goa Provision Of Standby Lt Cable From Hq Gna Substation To Seaview And Bayview Of Gomantak And Certain Minor Works Under Ge Gomantak Special Repair Replacement Of Ber Ceiling Fans At Nad And Mo
Open Tender
Indian
Goa
VASCO DA GAMA
19-10-2021

Tender Details

Special Repair Replacement Of Ber Ceiling Fans At Nad And Mo Goa Provision Of Standby Lt Cable From Hq Gna Substation To Seaview And Bayview Of Gomantak And Certain Minor Works Under Ge Gomantak Special Repair Replacement Of Ber Ceiling Fans At Nad And Mo Goa Provision Of Standby Lt Cable From Hq Gna Substation To Seaview And Bayview Of Gomantak And Certain Minor Works Under Ge Gomantak

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 56900.0 /-
Tender Value
INR 28.45 Lakhs /-

BOQ Items

Name of Work : Special Repair/ Replacement of BER Ceiling Fans at NAD and MO, Goa, Provision of Standby LT Cable from HQ GNA Substation to Seaview and Bayview of Gomantak and certain minor works under GE Gomantak
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m width andnot exc 1.5m in depth for Laying of UG cable getting out in hard/dense soil complete all as specified.
2Excavation in trenches not exceeding 1.5 m width andnot exc 1.5m in depth for Laying of UG cable getting out soft disintegrated rock complete all as specified.
3M/L for fine river sand for cushioning with layers of sand 8 cm before laying of cable & 15 cm after laying of cable (total 23 cm ) in trenches, duly punning to a thickness of 18 cmfor cable protection complete all as directed and specified. Note:- Thickness after punning shall be measured for payment.
4Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm with ISI mark.
5Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil or soft/disintegrated rock as specified & directed by Engr-in-Charge.
6Removal of surplus soil or rock to a distance not exceeding 50 m and depositing at a level not exc 1.5m above the starting point as directedby Engr-in-charge.
7Supply, Laying, joining & testingLT XLPE Insulated & sheathed armoured electric cables with multistranded aluminium conductor cable 1100 volts grade, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe ofsuitable sizes including cable gland of suitable sizes & aluminium lugs for connection for cross- sectional area 185 Sq mm 3.5 Core complete all as specified and directed.
8Supply and installation of LT panel "KIOSK type" cubical, weather, dust and vermin proof (out door type) of size 1mx0.9x0.45 CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3.15mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back sideincluding aluminium busbar size 50 x 5 mm,fixing on angle iron size of 50x50x6mm including connected accessories and necessaryPCC work 1:3 :6 type C-2 blocks complete with following accessories :- (i)MCCB 250 Amps, 4 pole, 25 kA, Adjustable thermal and fixed magnetic setting - 01 No (I/C). (ii) MCCB 63 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (O/G). (vi)Onload Changover switch 400 Amps - 01 No (vii) S&F multi function digital meter with LCD display incl PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO) (viii)Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set. (ix)Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot
9GI tubing (light grade) with all fittings,laid in trenches, or fixed along with walls /poles,bore of pipe 80mm.for proection of UG Cable all as directed by Engr-in-Charge.
10M&L for Cement concrete in foundation filling and mass concrete 1 : 4 : 8type D1 complete all as directed by Engineer-in-charge.
11Supply & fixing BLDC (Brushless DC motor) ceiling fan 1200mm sweep (ISI Marked), 230 volts including connection rod of various size from 0.5 mtr to 2 mtr as per existing size of length of GI pipe medium grade, twin core flexible wire and clamp complete and disconnecting the old and depositing in MES store all as per specified and directed. Make : Havells (Efficiencia Neo) or equivalent in Usha/Bajaj/Crompton
12Supply & fixing BLDC (Brushless DC motor) ceiling fan 1400mm sweep (ISI Marked), 230 volts including connection rod of various size from 0.5 mtr to 2 mtr as per existing size of length of GI pipe medium grade, twin core flexible wire and clampcomplete and disconnecting the old and depositing in MES store all as per specified and directed. Make : Havells (Efficiencia Neo) or equivalent in Usha/Bajaj/Crompton
13Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit with inbuilt air ioniser & plasma filter for better indoor air quality with minimum 3 star rating andEER 3.2 of capacity 1.5 TR with copeer tubing condensor including all necessary fixing arrangement and accessories including mounting bracket for outdoor unit. Make: Daikin / Carier/ Hitachi. Note: (1)The cost of AC also includes cost of copper tubing and insulation as per manufacturer. (2) If extra copper tubing and insulation required at site, the same will be measured and paid seperate under respective item of sch.
14M&L for voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 290 volt with output voltage stabilized at 230 volt with accuracy of +/-2.5% for the capacity 5 KVA.
15Supply & Fixing of sheet metal enclosure single pole and netural with a two pin and earth metal plug and socket complete with one single pole MCB 240 Volts 20 Amps Make: Legrand/ Havells/ Anchor
16Supply and fix insulation for copper tubes of split type AC units,insulation type superior of size 3/8"diameter complete all as per specified and directed by Engr-in-Charge.
17Supply and fix insulation for copper tubes of split type AC units,insulation type superior of size 5/8"diameter complete all as per specified and directed by Engr-in-Charge.
18Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 5/8" diameter complete all as per specified and directed by Engr-in-Charge.
19Supply and fix in repairs copper tubing soft grade suitable for split type AC suction /discharge line of size 3/8" diameter complete all as per specified and directed by Engr-in-Charge.
20Supply & Fixing submain wiring with 2 Runs of 4 Sqmm, PVC insulated, unsheathed, single core, multi stranded, 1100 volts, copper conductor cable drawn in and including 25/32mm wide PVC casing and caping with all accessories such as tees, elbows, juction box, reducers etc as required along with 1 run of 4 sqmm PVC insulated, unsheathed, single core, multi stranded coper conductor cable as continuous earth wire and connecting to existing main switch board/Distribution Board and testing on completion including taking down old submain wiring of any type with conduit comlete all as directed by Engineer-in-Charge. Note : 3 runs of 4 SqmmPVC insulated, unsheathed, single core, multi stranded copper conductor cable and 1 run of PVC casing/caping 25mm/32mm wide shall be measured as single run. Make: V Guard/ Havells/ Anchor
Disclaimer :