Mishra Dhatu Nigam Limited has published Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I , Zone -1 High Velocity Burners With Rated Capacity Of 280 Kw (Min) @ 30°. Submission Date for this Tender is 25-10-2021. Kitchen Equipment Tenders in MIDHANI,HYDERABAD Telangana. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Oct-2021 | DUE DATE EXTENSION | Date | 25-10-2021 |
Sl. No. | Item Description |
1 | Zone -1 High Velocity Burners with rated capacity of 280 KW (Min) @ 30°C combustion air temperature. Burner assembly should include burner block/Ceramic tube. Burner should be supplied with all standard accessories like gas limiting orifice and flame detection rod |
2 | Zone-1 Individual Burner Air Line manual air flow adjusting butterfly valve flanged type. Butterfly valve should be suitable for Burners quoted for Zone-1 |
3 | Zone-1 Flexible hose / Flexible connector suitable to Zone-1 burner air line fittings |
4 | Zone-1 Individual burner Gas Line solenoid valve (Fast opening and Fast closing type), solenoid valve should be suitable for burners quoted for zone-1 |
5 | Zone-1 Flexible hose / Flexible connector suitable to Zone-1 burner gas line fittings |
6 | Zone -2 High Velocity Burners with rated capacity of 165 KW (Min) @ 30°C combustion air temperature. Burner assembly should include burner block/Ceramic tube.Burner should be supplied with all standard accessories like gas limiting orifice and flame detection rod |
7 | Zone-2 Individual Burner Air Line manual air flow adjusting butterfly valve flanged type. Butterfly valve should be suitable for Burners quoted for Zone-2 |
8 | Zone-2 Flexible hose / Flexible connector suitable to Zone-2 burner air line fittings |
9 | Zone-2 Individual burner Gas Line solenoid valve (Fast opening and Fast closing type) solenoid valve should be suitable for burners quoted for zone-2 |
10 | Zone- 2 Flexible hose / Flexible connector suitable to Zone-2 burner gas line fittings |
11 | Zone -3 High Velocity Burners with rated capacity of 105 KW (Min) @ 30°C combustion air temperature. Burner assembly should include burner block/Ceramic tube.Burner should be supplied with all standard accessories like gas limiting orifice and flame detection rod |
12 | Zone-3 Individual Burner Air Line manual air flow adjusting butterfly valve flanged type. Butterfly valve should be suitable for Burners quoted for Zone-3 |
13 | Zone-3 Flexible hose / Flexible connector suitable to Zone-3 burner air line fittings |
14 | Zone-3Individual burner Gas Line solenoid valve (Fast opening and Fast closing type) solenoid valve should be suitable for burners quoted for zone-3 |
15 | Zone- 3 Flexible hose / Flexible connector suitable to Zone-3 burner gas line fittings |