Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I , Zone -1 High Velocity Burners With Rated Capacity Of 280 Kw (Min) @ 30°, MIDHANI,HYDERABAD-Telangana

Mishra Dhatu Nigam Limited has published Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I , Zone -1 High Velocity Burners With Rated Capacity Of 280 Kw (Min) @ 30°. Submission Date for this Tender is 25-10-2021. Kitchen Equipment Tenders in MIDHANI,HYDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

29299776
Corrigendum : Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I , Zone -1 High Velocity Burners With Rated Capacity Of 280 Kw (Min) @ 30°
Open Tender
Indian
Telangana
MIDHANI,HYDERABAD
25-10-2021

Tender Details

Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I Supply Of Combustion System Parts For Drever Make Roller Hearth Furnace As Per Annexure-I , Zone -1 High Velocity Burners With Rated Capacity Of 280 Kw (Min) @ 30°C Combustion Air Temperature. Burner Assembly Should Include Burner Block/Ceramic Tube. Burner Should Be Supplied With All Standard Accessories Like Gas Limiting Orifice And Flame Detection Rod , Zone-1 Individual Burner Air Line Manual Air Flow Adjusting Butterfly Valve Flanged Type. Butterfly Valve Should Be Suitable For Burners Quoted For Zone-1 , Zone-1 Flexible Hose / Flexible Connector Suitable To Zone-1 Burner Air Line Fittings , Zone-1 Individual Burner Gas Line Solenoid Valve (Fast Opening And Fast Closing Type), Solenoid Valve Should Be Suitable For Burners Quoted For Zone-1 , Zone-1 Flexible Hose / Flexible Connector Suitable To Zone-1 Burner Gas Line Fittings , Zone -2 High Velocity Burners With Rated Capacity Of 165 Kw (Min) @ 30°C Combustion Air Temperature. Burner Assembly Should Include Burner Block/Ceramic Tube.Burner Should Be Supplied With All Standard Accessories Like Gas Limiting Orifice And Flame Detection Rod , Zone-2 Individual Burner Air Line Manual Air Flow Adjusting Butterfly Valve Flanged Type. Butterfly Valve Should Be Suitable For Burners Quoted For Zone-2 , Zone-2 Flexible Hose / Flexible Connector Suitable To Zone-2 Burner Air Line Fittings , Zone-2 Individual Burner Gas Line Solenoid Valve (Fast Opening And Fast Closing Type) Solenoid Valve Should Be Suitable For Burners Quoted For Zone-2 , Zone- 2 Flexible Hose / Flexible Connector Suitable To Zone-2 Burner Gas Line Fittings , Zone -3 High Velocity Burners With Rated Capacity Of 105 Kw (Min) @ 30°C Combustion Air Temperature. Burner Assembly Should Include Burner Block/Ceramic Tube.Burner Should Be Supplied With All Standard Accessories Like Gas Limiting Orifice And Flame Detection Rod , Zone-3 Individual Burner Air Line Manual Air Flow Adjusting Butterfly Valve Flanged Type. Butterfly Valve Should Be Suitable For Burners Quoted For Zone-3 , Zone-3 Flexible Hose / Flexible Connector Suitable To Zone-3 Burner Air Line Fittings , Zone-3Individual Burner Gas Line Solenoid Valve (Fast Opening And Fast Closing Type) Solenoid Valve Should Be Suitable For Burners Quoted For Zone-3 , Zone- 3 Flexible Hose / Flexible Connector Suitable To Zone-3 Burner Gas Line Fittings , Burner Control Unit Comprising Of Ignition Electrode, Ignition Transformer And Ignition Cable (Cable Length: Minimum 4 Mtr)

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Oct-2021 DUE DATE EXTENSION Date 25-10-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Supply of Combustion System Parts for DREVER make Roller Hearth Furnace
Sl. No. Item Description
1Zone -1 High Velocity Burners with rated capacity of 280 KW (Min) @ 30°C combustion air temperature. Burner assembly should include burner block/Ceramic tube. Burner should be supplied with all standard accessories like gas limiting orifice and flame detection rod
2Zone-1 Individual Burner Air Line manual air flow adjusting butterfly valve flanged type. Butterfly valve should be suitable for Burners quoted for Zone-1
3Zone-1 Flexible hose / Flexible connector suitable to Zone-1 burner air line fittings
4Zone-1 Individual burner Gas Line solenoid valve (Fast opening and Fast closing type), solenoid valve should be suitable for burners quoted for zone-1
5Zone-1 Flexible hose / Flexible connector suitable to Zone-1 burner gas line fittings
6Zone -2 High Velocity Burners with rated capacity of 165 KW (Min) @ 30°C combustion air temperature. Burner assembly should include burner block/Ceramic tube.Burner should be supplied with all standard accessories like gas limiting orifice and flame detection rod
7Zone-2 Individual Burner Air Line manual air flow adjusting butterfly valve flanged type. Butterfly valve should be suitable for Burners quoted for Zone-2
8Zone-2 Flexible hose / Flexible connector suitable to Zone-2 burner air line fittings
9Zone-2 Individual burner Gas Line solenoid valve (Fast opening and Fast closing type) solenoid valve should be suitable for burners quoted for zone-2
10Zone- 2 Flexible hose / Flexible connector suitable to Zone-2 burner gas line fittings
11Zone -3 High Velocity Burners with rated capacity of 105 KW (Min) @ 30°C combustion air temperature. Burner assembly should include burner block/Ceramic tube.Burner should be supplied with all standard accessories like gas limiting orifice and flame detection rod
12Zone-3 Individual Burner Air Line manual air flow adjusting butterfly valve flanged type. Butterfly valve should be suitable for Burners quoted for Zone-3
13Zone-3 Flexible hose / Flexible connector suitable to Zone-3 burner air line fittings
14Zone-3Individual burner Gas Line solenoid valve (Fast opening and Fast closing type) solenoid valve should be suitable for burners quoted for zone-3
15Zone- 3 Flexible hose / Flexible connector suitable to Zone-3 burner gas line fittings
16Burner Control Unit Comprising of ignition electrode, Ignition transformer and ignition cable (cable length: minimum 4 mtr)