Provn Of Additional Dog Kennel And Certain Other Sanctioned Works At Af Stn Halwara Provn Of Additional Dog Kennel And Certain Other Sanctioned Works At Af Stn Halwara, GE (AF) Halwara-Punjab

Military Engineer Services-MES has published Provn Of Additional Dog Kennel And Certain Other Sanctioned Works At Af Stn Halwara Provn Of Additional Dog Kennel And Certain Other Sanctioned Works At Af Stn Halwara. Submission Date for this Tender is 12-10-2021. Civil Work Tenders in GE (AF) Halwara Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

29291009
Corrigendum : Provn Of Additional Dog Kennel And Certain Other Sanctioned Works At Af Stn Halwara Provn Of Additional Dog Kennel And Certain Other Sanctioned Works At Af Stn Halwara
Open Tender
Indian
Punjab
GE (AF) Halwara
12-10-2021

Tender Details

Provn Of Additional Dog Kennel And Certain Other Sanctioned Works At Af Stn Halwara Provn Of Additional Dog Kennel And Certain Other Sanctioned Works At Af Stn Halwara

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 83400.0 /-
Tender Value
INR 41.70 Lakhs /-

BOQ Items

Name of Work: Provn of additional Dog Kennel and certain other sanctioned works at AF stn Halwara
Sl. No. Item Description
1Suface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specfied and directed.
2Excavation over areas not exceeding 1.5m deep and getting out in hard/dense soil complete all as specfied and directed.
3Excavation in trenches in soft or loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre widefor foundations etcor for shafts, wells, cesspits, manholes, pier holes etc not exc 10 sqmon plan and getting out complete all as specified and directed. Notes : (i)Payment for excavation shall be made for one time in case the newcable is laid in the same trenches. (ii) Excavation upto top of brick protection shall be measured for payment purposes.
4Excavation in post holes (or similar holes ) each n.exc 0.50 Cum,and getting out,returning filing in and ramming earth with broken rubble mixed with earth around in layers n.exc 25cm,watering etc and removing surplus soil n.exc 50m and making good surface in loose/soft soil complete all as specified and directed.
5Spreading and levelling in layers not exc 25cm thick, well ramming including watering as required complete all as specified and directed.
6Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
7Removing excavated spoil to a distance exc 250 mtr but not exc 500mtr and depositing where directed not exc 1.5m above the starting point complete all as specfied and directed.
8Removing excavated spoil to a distance not exc 50 mtr and depositing where directed not exc 1.5m above the starting point complete all as specfied and directed.
9M&L for PCC 1:4:8 Type D-2 using 40mm crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
10M&L for PCC 1:2:4 Type B-2 using 40mm crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
11M&L for brick work with sub class ‘B’ brick, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified
12M&L for brick work with sub class ‘B’ brick, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified
13M&L for 15 mm thick cement mortar 1:6 on brickor concrete surface finished even and fair without using extra cement all as specified
14All as per Srl item No 13 above but 15 mm thick in cement mortar 1:4including water proofing compound mixed as per manufacturers instructions complete all as specified and directed. Note : Water proofing compound will be paid separately as supply only under respective items of this schedule.
15M&L for 5 mm thick cement mortar 1:3 on ceiling surface finished even and smooth without using extra cement all as specified
16M&L for hardcore of broken stone or boulders guages not exc 63mm deposited, spread and levelled in layers not exc 15cm thick, watered and rammed to true surface complete all as specified and directed.
17M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in sub base in floors complete all as specified and directed.
18M&L for 75mm thick PCC 1:2:4 type B-2 using 40mm graded stone aggregates as infloors finished even and smooth without using extra cement complete all as specified and directed.
19M&L for 100mm thick PCC 1:2:4 type B-2 using 40mm graded stone aggregates as infloors finished even and smooth without using extra cement and spikes rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed.
20M&L for 100mm thick PCC 1:2:4 type B-2 using 40mm graded stone aggregates as infloors finished even and smooth without using extra cement complete all as specified and directed.
21M&L for PCC (1;2:4) type B-1 using 20mm graded stone aggregete as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-charge.
22M&L for Glazed ceramic colouredtiles (300x200mm) x6-7mm thick on vertical surfaces as in skirting/dado,set and jointed with neatcement slurry and pointed in white/coloured cement to match the shade of tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
23M&L for Non-skid jointless cerermic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18 Sqm, in neatcement slurry and pointed in white or coloured cementwith pigment over and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed.
24S&F powder coated Anodised aluminium frame for doors, windows, ventilatorsor in partitions with one or more rebates including jointing cleats for fixing etc complete all as specified and directed
25S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary jointing cleats, glazing clips, ruber neoprene packing, handle 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed.
26S&FAnodised aluminium grills of anypattern/design of weight not less than 1.50 kg/sqm and fixed with screws to windows complete all as specified and directed.
27S&F 4.8mm thick sheet glass selected quality and glazing in squares exc 0.50 Sqm in each pane complete all as specified and directed.
28M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410-W Gde E-250 quality B
29M&L for framed work as in stairs using hollow sections including stringers, treads, landing balusters, hand rails etc including cleats, brackets using mild steel confirming to Fe-290 Gde E-165 complete all as specified and directed.
30M&L for rolled mild steel plate (plain or chequerred) square cut or notched (ordinary and counter sunk) forming holes without any attached confirming to Fe-410W Gde E-250 Quality A complete all as specified and directed.
31S&F mild steel fasteners 10mm dia and 100mm long including bolts with washers for fixing in RCC/PCC/Masonary in horizotal or vertical surfaces complete all as directed by Engr-in-Charge
32S&F framed work such as grills, grating etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars and similar work conforming to Fe-410-0 or Fe-301-0 complete all as specified and directed.
33S&F stainless steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tined tacks complete all as specified and directed.
34Mild steel TMT bars 10mm dia and over, cut to length bent to shape reqiored including cranking, bending spirally for hooping for columns, hooking ends and binding with including mild steel wire (annealed)not less than 0.9mm dia or securing with clips complete all as specified and directed.
35Alll as per Sl item No 34 abovebut 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders etc.
36M&L for formwork to walls/parapets and stair case railings, retaining walls, abutments and similar works complete all as specified and directed.
37M&L for RCC M-25 design mix as in walls, retaining walls, basement walls, ballast and the like, any thickness, above top of footings including attached pillasters and butresses complete all as specified and directed.
38M&L for formwork to sides of concrete foundations, footings, base of columns, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
39M&L for RCC M-25 design mix as in foundations including rafts, foundation beams, plinth beamss, bases for columns etc, basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
40M&L for formwork to sides of pillars, posts, struts, piers, coliumns and stanchions etc for fair finished surfaces of concrete complete all as specified and directed.
41M&L for RCC M-25 design mix as in columns, pillars, piers, post and struts etc complete all as specified and directed.
42M&L for formwork to sides and soffits of floor or roof beams, lintels, lintel bands for fair finished surfaces of concrete complete all as specified and directed.
43M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs not exc 20cm wide and sides of RCC/PCC band in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide complete all as specified and directed.
44M&L for RCC M-25 design mix as in beams, cantilevers, ressummers, lintels over 1.50m spancomplete all as specified and directed.
45M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exceeding 200mm thick (horizontal or sloping) complete all as specified and directed.
46M&L for RCC M-25 design mix as in slabs supported on walls, beams and columns in floors, landings, balconies,canopies, dec slab and in shelves and the like complete all as specified and directed.
47M&L for precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in fencing posts, boundary pillars etc with plain fair face including chamfers, weatherings etc complete all as specified and directed.
48S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed wih 2mm dia barbs at 75mm spacing and stranining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. complete all as directed (each line wire to be measured)
49S&F bands, straps, supports or stays for rainwater, ventilating pipes including bolts if requried, hooks (stay), heavy, for large gates, hook and pintle hinges and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
50S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm each panes complete all as specified
51S&F 110 mm dia PVC (SWR)Rain water pipessingle socketedin any length with rubber ring joints fixed towalls complete all as specified and directed.
52M&L for 75 mm thick PCC 1:3:6 type C2 as in plinth protection finishedeven and smooth without using extra cement complete all as specified and directed.
53M&L for 25mm thick PCC type B-0 (using 12.5mm graded stone aggregates)as in floors/sub base etc and finishing the surface rough and even to receive top layer as under tiles, stone etc complete all as specified.
54M&L for 60mm thick rubber moulded interlocking paver block with grey cement and pigment of any size and shape confirming to IS 15658-2006, M-35 Grade as approved by Engr-in-Charge,laid in flooring and joints filled/broomed with fine sand complete all as specified and directed.
55S&F Mild steel work as in rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, Tee, angle channel or flat sections) including distance pieces, cleats etc.(Fe-410-W(Gde E-250)Quality-B)
56S&F rolled Mild steel work as in FOD Traps,compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and like including caps bases, splices etc built up from two or more beam or channel sections or angles with plates or pipe section including all lattice bars, stiffeners, gusset plates etc.(Fe-290-W(Gde E-165) complete all as shown on drawing held with Engr-in-Charge and as directed.
57S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
58S&F 1mm thick mild steel plain black sheet in wall cladding, steel gates and similar work,cut to size, holes punches including round headed screws, clout nails or rivets and fixed complete all as specified and directed.
59Supply only integral waterproofing compound .
60Preparation of new steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
61M&Lforpreparation of new plastered surfaces of walls, applying a layer of wall care putty, one coat of primer and applying two coat of distemper oil emulsion completel all as specified and directed
62M&Lfor prepration of newplastered surfaces of wall and applying three coat of white wash complete all as specified and directed
63M&L for prepration of new plastered surfaces of ceiling and applying three coat of white wash complete all as specified.
64M&L for preparation ofnew plastered surfaces of walls and applying two coats of synthetic enamel paint in camouflage pattern using minimum 3 different approved tint/colour as approved by GE complete all as specified and directed
65M&L for 300mm internal bore dia reinforced concrete pipes, class NP3 laid in trenches and jointed and testing complete all as specified and directed.
66Concrete bed to drain pipes of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate including packing under, and haunching against the sides of pipes after they are laid and tested for 300 mm bore RCC pipe line complete all as specified and as directed. Note: RCC pipe will be measured and paid for separately.
67M&L for PCC 1:3:6 type C1using 20 mm grade stone aggregate as in surface channel, drain etc including necessary use and waste of form work complete all as specified.
68Extra for forming fair finished drain or channel 30 cm inner girth in cementusing extra cement, including forms, moulds, mitred/stopped ends complete all as specified.
69M&L for pre cast cement concrete cover in RCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in cover slab for manhole and similar article with plain face, set in cement mortar 1:4 complete all as specified and direceted.
70M & L for concealed Point wiringfor light points with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit not less than 19/20 mm dia with all fittings shunk in MS Pressed steel terminal boxessuitable depth and 1.6mm thick (duly painted with two coat of anticorrosive paint outsite andAluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified. Note : Quoted rates are inclusive of cutting chases and making good disturbed surfaces to match with the existing surfaces.
71All as per item No. 70 here-in before but one ceilling / exhaust fan/ventilating fan point controlled by one 5 Amps one way switch and regulator
72All as per item No. 70 here-in before but one 5 pin 6 Amps switch socket outlet point on same board..
73All as per item No. 70 here-in before but One 5 pin 6 Amp switch socket outlet point on independent board.
74All as per item No. 70 here-in before but 4.00 Sqmm copper wiring with 2.50Sqmm copper conductor as earth continuity for 15/16 Amps socket out let on independent board
75S&F switch piano type one way 5 amps 240 volts complete.
76S&F socket outlet 5 pin 5 Amps flush type complete.
77S&F switch piano flush button single pole one way 15 amps 240 volts complete.
78S&F socket out let 2 in 1, 6 pin, 5 and 15 amps multi purpose flush type, 230 volts.
79S&F electronic fan regulatorstep, 250V flush type on the exiting phenolic laminated sheet etc.
80S&F ceiling rosesurface bakelite 3 terminals.
81S&F lamp holder PVC/ Polycarbonate insulated body with back plate for angle/batten fittings complete.
82S&F retrofit LED lamp 9 watt light complete
83S&F in reparis LED light fitting, 20 W, 4 ft long 230V, Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wiredincluding connecting up with twin core twisted flexible copper conductor cable complete all as specified.
84Supply and fixing of building security light fitting 120 W LED New generation Energy Saving & Environment friendly long life versatile pressure die-cast aluminium IP-66 roadwayluminars with high power LEDs as light source and electronic drive including connecting complete.
85Supply and fix security light mounting bracket, GI pipe 40mm dia medium grade for mounting bracket bent to shape 1.50 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of Zinc oxide primer complete all as directed.
86M&L forSub main wiring with PVC insulated cable of size 2 X 6.0 Sqmm + 1 X 4.0 Sqmm earth wire multi stranded copper conductor drawing into and includingheavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc. complete all as specified and directed.
87M&L forSub main wiring with PVC insulated cable of size 2 X 4.0 Sqmm + 1 X 4.0 Sqmm earth wire multi stranded copper conductor drawing into and includingheavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc.
88M&L forSub main wiring with PVC insulated cable of size 2 X 4.0 Sqmm + 1 X 2.50 Sqmm earth wire multi stranded copper conductor drawm into steel conduit and continuous earth wire complete all as specified and directed. Note :Steel conduit shall be measured and paid seperately.
89Supply, laying and connecting, LT UG cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size 25 sqmm 3.5 corecomplete all as specified and directed.
90Supply, laying and connecting, cable XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor laid in trenches/on poles/walls/in ducts/passing through pipes etc including jointing materials such as cable glands, lugs etc of size6.00 sqmm 2 corecomplete all as specified and directed.
91M&L for flame proof point wiring for light point including ERW conduit with two single corecable (FRLS) PVC insulated unsheathed 1100 volt grade copper conductor multi standred of size 2.5 Sqmm and including of one run earth wiresingle corecable (FRLS) PVC insulated unsheathed 1100 volt grade copper conductor multi standred of size of 1.5 Sqmm to be drawn in 25mm dia ERW stove enamelled black rigid conduit with all flame proof conduit accessories such as tee, bend elbow, conduit junction box complete all as specifiedand directed. Note : ERW conduit, conduit accessories, circuit wires and earth wires complete shall be treated as one unit.
92M&L for ERW steel conduit 20mm dia concealed in walls with flame proof accessories like tee, bend, elbow, conduit junction box or bell mouth reducer and making good the disturbed surfaces to match with the existing surfaces complete all as specified and directed. Note : Quoted rate shall deemed to be incusive of rates for cutting chases and making good.
93S&F flame proof/weather proof direct entry typerotary switch singlepole ON & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 240Volts 16 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc duly tested & certified by CMRI-Dhanbad.
94Supply and fix "B" series MCB SPN 40 amps, 240 volts, 50Hz.
95Supply and fix "B" series MCB SP 6 to 32 amps, 240 volts, 50Hz.
96S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 25 Amps rating 10 KA, "C" curve, 415 volts complete all as specified and directed.
97Supply and fix sheet metal enclosure MCB SPN distribution board,8 way, Double door with IP-43 protection single phase 240 volts, including suitable size copper bus bar and neutral link fixed flush concealed in wall including taking out old DB"s and chases wall for fixing DB and making good distributed wall/surfaces to match with existing specification.
98M&L for brick protection with sub class "B" bricks (old size) laid dry, flat in trenches over cable with longest dimension perpendicular to the axis of the cable complete all as specified and directed specified .
99Material & labour for sand cushioning in trenchesand well ramming in layers with 8 cm below and 15 cm above the cable with fine dry sand for cable protection and complete all as specifiedand directed.
100S&F 40mm bore GI tubing light grade as in cable protection pipe including all fittings complete all as directed
101M&L earthing complete with galavanised steel plate electrode 600x600x6.0mm thick burried directly in ground vertically (earth pit to a depth of not less than2.25 meter deep below ground level) with the top adge of earth place at a depth of not less than 1.5 meter below normal ground level connected to galvanised iron earth lead wire 4mm dia by means of bolts, nuts, washers of galvanised iron and provision of earth wire, galvanised iron protection pipe 15mm bore, light grade up to and including test point including necessary earth work in any type of soild and PCC (1:3:6) type C1 (using 20mm graded stone aggregate) earth chamber, watering pipe 20mm dia galvanised iron light grade with funnel, RCC (1:2:4) type B1 precast cover 40mm thick with 6mm dia mild steel bars complete all as shown in electrical plate N.5 of SSR part-I connected to earthing test point all as specified or indicated,including taking down and testing on completion Note:- Quoted rate deemed to include the cost of excavation and earth work, PCC pit, funnel and cover etc, Note: - (a)Item of earthing includes cost of 20/40mm bore medium grade GI protection pipe and 7.50 metre long earth strip/lead upto test point. (b)On testing after completion of work, if desired earth resistance is not obtained earthing will be re-done by the contractor without any extra cost to the Govt.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy