Bids Are Invited For Prgorammable Bidirectional Dc Power Supply As Battery Simulator And Fuel Cell Simulator - Output Voltage Range: 0 To 1200V Dcoutput Current Range: ±40A Dcoutput Power Range: ±18Kw With Regenerative Capabilityinput Supply 3-Phase, 380--Delhi
TDR : 29268969
Tender Notice
Corrigendum Details
BOQ
Expired
Delhi
Corrigendum : Bids Are Invited For Prgorammable Bidirectional Dc Power Supply As Battery Simulator And Fuel Cell Simulator - Output Voltage Range: 0 To 1200V Dcoutput Current Range: ±40A Dcoutput Power Range: ±18Kw With Regenerative Capabilityinput Supply 3-Phase, 380-
Prgorammable Bidirectional DC Power Supply as Battery Simulator and Fuel Cell Simulator
Output Voltage Range: 0 to 1200V DCOutput Current Range: ±40A DCOutput Power Range: ±18KW with regenerative capabilityInput supply 3-phase, 380-400VAC, 47-63hz, power factor of 0.97 or above
2
Electrical Charctersitics
Line Regulation Voltage :+/- 0.01% of full scale or belowLine Regulation Current: +/- 0.05% of full scale or below Output Voltage Ripple 300 mV (rms) or below Output Current Ripple 100 mA (rms) or belowControllable slew rate Minimum of 180V/ms
3
Extendable operational capability
Series Operation: Up to 2-Units for increasing voltage & PowerParallel Operation: Master / Slave control for 10 units up to 180kW
4
Safety & Protections
Overvoltage Protection, Overcurrent Protection, Overpower Protection, Over temperature Protection, AC Fault, Fan Fail protection
5
Additional features
Able to use as a DC source only mode, DC load only mode and bidirectional as (DC source + DC load) mode at a timeAble to program from front panel display hardware for programming sequences for DC source, DC load and (DC source + DC load) modes DC Load mode must be operating in CC, CV & CP Mode.
6
Software features
Able to use as a DC source only mode, DC load only mode and bidirectional as (DC source + DC load) mode at a timeAble to program from front panel display hardware for programming sequences for DC source, DC load and (DC source + DC load) modesDC Load mode must be operating in CC, CV & CP Mode.
7
Battery and Fuel Cell Emulator features
- Built-in setup for Battery simulator with below features :a. Able to Set SOC Voltage 0% & 100% SOC, DCR, Total capacity, series-parallel no. of batteries/cell.b. Able to upload curve for OCV VS Capacity and OCV VS SOC through excel sheet/word format.c. Able to start battery simulation through Voltage level, capacity (AH), SOC%.-Built-in setup for Fuel cell simulator with below features:a. Able to upload basic curve.b. Able to upload current & voltage curve through excel sheet/word format.c. Able to set cell no. & area.
8
All in one PC
System should be supplied with a All in one PC, Intel i5 processor, windows 10, 8GB RAM or better