Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-10-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-10-2021 |
| 2 | 24-09-2021 | CORRIGENDUM02 | BOQ | 07-10-2021 |
| 3 | 24-09-2021 | CORRIGENDUM01 | BOQ | 07-10-2021 |
| 4 | 24-09-2021 | REVISED TENDER DOCUMENTS | Other | 07-10-2021 |
| Sl. No. | Item Description |
| 1 | Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and directed. |
| 2 | Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSHPVC insulated and unsheathed stranded cable drawn through and including existing non metallic/mettalicheavy duty concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI sunken boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint over a coat of red oxide primer internallyand externally including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathedFRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed.NOTES : - 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. |
| 3 | Description all as per item No 2.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed. |
| 4 | Description all as per item No 2.00 here in before but for socket out let point 5 Amps on independentboard complete all as specified and directed. |
| 5 | All as per srl item No 2.00 above but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed. |
| 6 | Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, heavy duty PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI sunken boxes made out of 1.2mm thick of any module from 2 to 18module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint over a coat of red oxide primer internallyand externally including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over sunken box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbedsurfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dollywith suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed.NOTES : - 1. Switch, socket and fan regulators to be measured and paid for separately.2. All chases will be cut by chase cutter only. |
| 7 | Description all as per item No 6.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed. |
| 8 | Description all as per item No 6.00 here in before but for socket out let point 5 Amps on independentboard complete all as specified and directed. |
| 9 | All as per srl item No 6.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switchwith using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed. |
| 10 | Supply and fixing for modular switches, bell push,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 11 | Supply and fixing for modular switches, one way,6 amps one module, 230V, 50 Hz supply, complete all as specified and directed. |
| 12 | Supply and fixing for modularswitches, oneway, 16 Amps, one module, 230 volt, AC supply, complete all as specified and directed. |
| 13 | Supply and fixing for modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed. |
| 14 | Supply and fixing for modular socket outlet 6/16 amps,2/3 pin , combined 2 module, complete all as specified and directed. |
| 15 | Supply and fixing for fan regulatorstep type one module / 2 module, 120w 230 Volts, 50 Hz, AC complete all as specified and directed. |
| 16 | Supply and fixing for modular blanking plate 1 module complete all as specified and directed. |
| 17 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 25 mm dia with FRLSH )accessories, concealed on wall/ceilingand including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch. NOTES : - Switch, socket and fan regulators to be measured and paid for separately . |
| 18 | Description all as per item No 17.00 here in before but for socket out let point 5 Amps on same board,complete all as specified and directed. |
| 19 | Description all as per item No 17.00 here in before but for socket out let point 5 Amps on independentboard,complete all as specified and directed. |
| 20 | Description all as per item No 17.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed. |
| 21 | Supply and fixing for bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed. |
| 22 | Supply and fixing for switch piano 5/6Amps, flush type, single pole, one way,230 volt , AC supply,ISI Marked, complete all as specified and directed. |
| 23 | Supply and fixing for switch piano 15 Amps flush type one way 230 Volts,50 Hz , AC supply, ISI Marked, complete all as specified and directed. |
| 24 | Supply and fixing for socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed. |
| 25 | Supply and fixing for outlet 2 in 1, 3 pin 5 /15 Amp and multi pin flush type, complete all as specified. |
| 26 | Supply and fixing for ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. |
| 27 | Supply and fixing for fan regulator electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed. |
| 28 | Supply and fixing for door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified. |
| 29 | Supply and fixing for lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified. |
| 30 | Supply and fixing for channel for fixing of LED tube rod, aluminium housing body in CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. ( Tube rod shall be measured and paid for separately ). |
| 31 | Supply and fixing for 18 W/ 20W Polycarbonate LED tube light, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. Note: - Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings . |
| 32 | Material and labour for taking down existing llight fitting any type / size/make / capacity and refix the same after minor repair/ cleaning including replacement of connection wire with suitable size copper wire twin core flexible wire for connection from ceiling rose to light fitting all as specified and directed. |
| 33 | Supply and fixing for decorative surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housingin CRCA body suitable and including 10 watt LED tube high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 34 | Supply and fixing in repair bulk head light fitting, 10 watt, energy efficient withlamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting completeincluding disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 35 | Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing wall mounting bracket typr wooden base with finished and disgnied cover of V/opal/spherical shapewith and including 9 to 12 watt LED lamp ofB22 base including connecting up with three core 1.5 sqmm flexible copper conductor cablecomplete all as specified and directed. |
| 36 | Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing surfacemounted type metal base with finished and disgnied diffuserof round/ square/ oval shape slim down lighter 12 watt LEDincluding suitable capacity driver complete connecting up with three core 1.5 sqmm flexible copper conductor cablecomplete all as specified and directed. |
| 37 | Supply and fixing in repair in replacement bracket for security light made up of 25mm dia, 0.9 metre long GI pipe,light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed. |
| 38 | Supply and fixing in repair LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 39 | Supply and fixing in repair LED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Two core 1.5 sq mmcopper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down oldunserviceable security light fitting of any description and in any position complete all as specified and directed. |
| 40 | Supply and fixing in repair post top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessoriesinternally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed. |
| 41 | Supply and fixing for LED based Bollard light 10 watt with aluminium pipe housing with glare free PMMA Diffuser, IP 65 of height not less than 800mmincluding necessary excavation & PCC work etc complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. |
| 42 | Supply and fixing for 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 10 Sqmm including all incoming and outgoing connection with proper size of thimble complete all as directed and specified. |
| 43 | Supply and fixing for 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable circulat of size 16Sqmm including all incoming and outgoing connection with proper size of thimble complete all as directed and specified. |
| 44 | Material and labour for taking down ceiling fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed. |
| 45 | Material and labour for taking down Exhaust fan of any size/ sweep after disconnecting the wire from existing ceiling rose dismentaling of blades and deposited to store for repair all as specified and directed. |
| 46 | Supply and fixing in repair fan condencer 2.5/ 4MFD, 240 volts suitable capacity for ceiling/ exhaust Fanall as specified and directed. |
| 47 | Supply and fixing in repair ball bearing of suitable size and capacity for ceiling/ Exhaust fan all as specified and directed. |
| 48 | Supply and fixing in repair hanging assymbly set comprising with rubber reel, MS clamps, nuts, bolts with one lock hole and lock pins suitable for any type of fans & down rods complete all as specified and directed. |
| 49 | Material and labour for rewinding of ceiling fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 1200/ 1400 mm sweep complete all as specified and directed.NOTE for item No 58 to 60 : -(ii) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate.(iii) The cost of shifting the fan from MES store yard to contractors workshop andback shall be included in the item.(iv) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair,in failing so, the amount @ Rs. 20/- per fan per day shall be deductedfrom the contractor due till the returning of fan duly tested. |
| 50 | Material and labour for rewinding of Exhaust fan of any size with super enameled copper wire of existing gauge incuding varnishing and drying complete reassembling & testing complete of size 230 to 450 mm sweep complete all as specified and directed.NOTE for item No 58 to 60 : -(ii) Fans to be repaired/ rewinded will be handed over to contractor at MES store yard after cutting the burnt winding in presence of Engr-in-charge and cost of cutting of winding shall be included in the quoted rate.(iii) The cost of shifting the fan from MES store yard to contractors workshop andback shall be included in the item.(iv) Fans will be issued to the contractor in lots of 10 Nos and more for which, contractor shall ensure that minimum lot of 10 number each be returned to the department on every fifth day from the issue of fans after carried out rewinding and other repair,in failing so, the amount @ Rs. 20/- per fan per day shall be deductedfrom the contractor due till the returning of fan duly tested. |
| 51 | Supply and fixing in repair metal fan blade including fixing mountings and accessories of exhaust fan of 230 to 450 mm sweep complete all as specified and directed. |
| 52 | Supply and fixing in repairs plastic body exhaust fan, AC singal phase,240 volts of size 230 mm sweep with heavy duty, plastic body with louvers connecting up including provision of fixing clamp, nut bolts and cable from ceiling rose or connector to fan,including taking down old unserviceable pastic body exhaust fan complete all as specified and directed. |
| 53 | Material and labour for painting of ceiling fanusing synthetic enamel paint in two coat over one coat of primer of any make/sweep/model etcafter cleaning/washing and fill up cavities using fillerincluding writing MES NO Black Colour complete all as specified and directed. |
| 54 | Material and labour for hanging only ceiling fan any type/ seep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades all as specified and directed. |
| 55 | Material and labour for fixing only exhaust fan any type/ seep after repair and connecting up including provision of cable from ceiling rose to connector to fan including refixing of blades, louvers etc all as specified and directed. |
| 56 | Taking down old unserviceable geyser of cap 25 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etcand checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessaryadjustment and refixing the repaired geyser in position, connecting to existing electric & water connectionsand testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate.(b) Examine any water leakage from geyser/storage tank.(c) Carry out operation of all stop cocks, pressure reducing valves,etc. to ensure free movement of the working parts.(d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items.(g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ. |
| 57 | Taking down old unserviceable geyser of cap 50 ltrs including all necessary electrical/water connection and keeping in safe custody for reuse inciuding all necessary minor repairs /servicing etcand checking serviceability of parts, necessary cleaning & reassembling the geyser, making necessaryadjustment and refixing the repaired geyser in position, connecting to existing electric & water connectionsand testing at site complete all as specified and directed. Note : The cost of minor repair including following works deemed to be included in quoted rates. (a) Inspection of geyser after opening bottom cover plate.(b) Examine any water leakage from geyser/storage tank.(c) Carry out operation of all stop cocks, pressure reducing valves,etc. to ensure free movement of the working parts.(d) Replace washers and glands to ensure smooth functioning. (e) Inspect vent pipes and remove blockage obstruction if any. (f) Check and correct earth continuity of electrical items.(g) Check and correct temperature setting of thermostats. (h) Items reqd for replacement will measured under respective item of BOQ. |
| 58 | Supply and fixing for copper cable PVC insulated and PVC sheathed flexible size 2.5Sqmm 3 core complete all as specified and directed.(Cable shallbe in suitable length as per site requirement). |
| 59 | Supply only heating element of capacity 2 KW of geysers of any make ISI marked complete all as specified and directed. |
| 60 | Supply only heating element of capacity 1.5 KW of geyser of approved make ISI marked complete all as specified and directed. |
| 61 | Supply only apparatus plate assembly with rubber gasket including nuts, bolts, washers for geysers of 50/35/25 ltrs capacity complete all as specified and directed. |
| 62 | Supply only thermostat ISI marked suitable for the Geysers 25 ltrs capacity, 20 Amps, 240 Volts AC, adjustable type, 210 mm long or nearest size as per sample complete all as specified and directed. |
| 63 | Supply only thermostat ISI marked suitable for the Geysers 50 ltrs capacity,20 Amps, 240 Volts AC, fixed type,300 mm long or nearest size, Set at 90+/-6 degreeC as per sample complete all as specified and directed. |
| 64 | Supply only PVC connections pipe with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for cold water as per requirement complete all as specified and directed. |
| 65 | Supply and fixing temperature resistent SS braided pipe suitable to sustaine pressure up to 8 barnot less than 60 Cm long suitable forout going / Hot water connections of Geyser with washer etc. complete as an directed. |
| 66 | Supply only Non-return valve 15mm / 20mm dia of brass ISI marked as per requirement complete all as specified and directed. |
| 67 | Supply onlyIndicators of Geysers of any capacity/type (Red & Green) as per requirement complete all as specified and directed. |
| 68 | Supply only 3 pin plug top, 16 amp capacity, 240 VAC, heavy duty, ISI marked complete all as specified and directed. |
| 69 | Supply only Geyser storage inner tank made out copper sheet suitable for 25 ltrs capacitycomplete all as specified and directed. |
| 70 | Supply only geyser storage inner tank made out copper sheet suitable for 50 ltrs capacity complete all as specified and directed. |
| 71 | Supply only safety valve plug made out brass metal with fusible lead, inner thread type suitable for geyser of any type/capacity complete all as specified and directed. |
| 72 | Supply and fixing in repair sheet metal enclosure SP with two pin and earth plug and socket with one single pole, MCB 20 Amps, \"B\" curve, 240 volts complete all as specified and directed. |
| 73 | Material and labour for sub main wiring with four single core FRLSH PVCinsulatedunsheathed copper conductor cable 10 sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 10 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed.Note- 5 run of 10 sqmm and 1 run of 32 mm concealed conduct shall be measured as 1 unit. |
| 74 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 2.5 sqmm drawnin and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 2.50 sqmm,green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed.NOTE : - 3 run of 2.5 sqmm and 1 run ofconcealed conduct shall be measured as 1 unit. |
| 75 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 4 sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 4 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed.Note- 3 run of 4 sqmm and 1 run ofconcealed conduct shall be measured as 1 unit. |
| 76 | Material and labour for sub main wiring with two single core FRLSH PVCinsulatedunsheathed copper conductor cable 6sqmm drawnin and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories onwall or ceiling withone additional PVC insulated , strandedcopper conductor FRLSHof 6 sqmm, green colourfor earthcontinuity conductor including taking down old unserviceable sub main wiringand making good the disturbed surface complete all as specified and directed.Note- 3 run of 6.0 sqmm and 1 run ofconcealed conduct shall be measured as 1 unit. |
| 77 | Taking down old unserviceable MCB DBs any type including MCB SP/SPN and removing unserviceable materials incl debris from site and keeping unserviceable DB/MCCB/MCB in safe custody for taking credit complete all as specified and directed. |
| 78 | Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 42 protection, with shrouded neutral bar and insulated bus bar and earth link, with and includingMCCB 4 pole,125AMPS ,25 KAas incomer and MCB sas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed. |
| 79 | Supply and fixing in repair sheet metal enclosures distribution board for TPN, (MCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 43 protection, with shrouded neutral bar and insulated bus bar and earth link, suitable forMCB 4 poleas incomer and MCB sas out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed. |
| 80 | Supply, installation, testingof SPN distibution board 12 way,double door , IP 43, as per IS 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed. |
| 81 | Supply, installation, testingofSPN distibution board 8 way,double door , IP 43, as per IS 8623including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed. |
| 82 | Supply, installation, testingof SPN distibution board 4 way,double door , IP 43, as per IS 8623including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed. |
| 83 | Supply and fixing for MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, \"B\" curve 6 to 32 Amps, ISI marked complete all as specified and directed. |
| 84 | Supply and fixing for MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, \"B\" curve 40 to 63 Amps, ISI marked complete all as specified and directed. |
| 85 | Supply and fixing for MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz,\"B\" Series complete all as specified and directed. |
| 86 | Supply and fixing for MCB single pole and neutral 240 volts, 40 to 63 Amps,10KA, 50 Hz, \"B\" Series complete all as specified and directed. |
| 87 | Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 100A complete all as specified and directed. |
| 88 | Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 40A to 63 Amps, B curve, complete all as specified and directed. |
| 89 | Supply and fixing for house service bracket (hook type completewith 3.0m long G.I. pipe 40mm dia Med.grade, two nos 90º bends. M.S. hook and stay or guy complete all as specified and directed. |
| 90 | Note : - Amount of credit ofRs. 64,098.00 for retrieved materials is mentioned in Schedule of Credit Page Nos. 19 of tender documents in pdf form which will be deducted offline while acceptance of tender. |