Special Repair To Bathroom And Toilet In Bldg No P-404 ( Otm ) Of Inf Bn-Iii And Provn Of Addn Treated Water Tank Special Repair To Bathroom And Toilet In Bldg No P-404 ( Otm ) Of Inf Bn-Iii And Provn Of Addn Treated Water Tank For Stp Water At Mil , ABOHAR-Punjab

Military Engineer Services-MES has published Special Repair To Bathroom And Toilet In Bldg No P-404 ( Otm ) Of Inf Bn-Iii And Provn Of Addn Treated Water Tank Special Repair To Bathroom And Toilet In Bldg No P-404 ( Otm ) Of Inf Bn-Iii And Provn Of Addn Treated Water Tank For Stp Water At Mil . Submission Date for this Tender is 16-10-2021. Toilet Bathroom Tenders in ABOHAR Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

29259051
Corrigendum : Special Repair To Bathroom And Toilet In Bldg No P-404 ( Otm ) Of Inf Bn-Iii And Provn Of Addn Treated Water Tank Special Repair To Bathroom And Toilet In Bldg No P-404 ( Otm ) Of Inf Bn-Iii And Provn Of Addn Treated Water Tank For Stp Water At Mil
Open Tender
Indian
Punjab
ABOHAR
16-10-2021

Tender Details

Special Repair To Bathroom And Toilet In Bldg No P-404 ( Otm ) Of Inf Bn-Iii And Provn Of Addn Treated Water Tank Special Repair To Bathroom And Toilet In Bldg No P-404 ( Otm ) Of Inf Bn-Iii And Provn Of Addn Treated Water Tank For Stp Water At Mil Stn Abohar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 70220.0 /-
Tender Value
INR 35.11 Lakhs /-

BOQ Items

Name of Work : Special repair to bathroom and toilet in Bldg No P-404 (OTM) of Inf Bn-III and provn of addn treated water tank for STP water at Mil Stn Abohar
Sl. No. Item Description
1SCHEDULE "A" SECTION I (B&R Portion)
2Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified.
3Demolition of cement concrete (reinforced) in roof , floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspepnded work
4M & L for 75mm thick cement concrete type C – 2(using 40 mm graded aggregate) (1:3:6) as in plinth protection finished cement concrete surface even & smooth with using extra cement etc all as specified .
5M & L mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc .
6Ditto all as per item No 5 but 5 mm dia and over up to and including 8 mm dia as in stirrups.
7Reinforced cement concrete M-25Design mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately).
8M&L for From work to soffits of suspended slabs, such as roof slabs, floor slabs landing and similar work not exceeding 200mm thick (Horizontal & sloping) fair finished surfaces (Note- Steel props to be use).
9M&L for From work to edges of concrete flates treads breaks in floors, window cill concrete railing, opening in convert valley floor and roof exc 5 but n.exc 10 cm wide and sides RCC/PCC band in walls.
10Providing precast cement concrete 1:2:4, type B-1 using 20 mm graded crushed stone aggregates as in cover slabs for manholes etc, set in cements mortar 1:6 .
11Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified .
12Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each andall as specified .
13S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of r
14S&F for Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
15S&F todoor frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge
16S & F Powder coated anodised aluminium frame for doors, windows, with one or more rebate including joining cleat for fixing etc complete.
17S & F in repairpowder coatedaluminium slidingwindowthree trackwith frame & two glass shutters using 4 mm thickglass tintedmodi guard and oneshutter with stainless steel wire gauge wirecloth 0.31 mm nominaldia of wire and width of aperture 1.61 mm using aluminium powder coated section aluminium cleat ,PVC track ,bearing, handle lock,rubber beading etc complete fittings as approved. Note:- Size of aluminium section shall be under-(i) Three track top and vertical- Jindal main-2010 section No 20621 or equivalent as approved by GE.(ii) Three track bottom - Jindal main - 2010sectionNo 20620or equivalent as approved by GE. (iii)Shutter vertical section -Jindal main -2010 section 20604 or equivalent as approved by GE . (iv)Shutter top and bottom - Jindal main -2010 Section 20604 or equivalent as approved by GE.(v)Shutter vertical middle (interlock) - Jindal Main -2010 Section 20605 or equivalent as approved by GE.
18S & F Powder Coated Aluminium window and ventilator shutters aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips rubber neoprene packing handles 2 nos on each door, hinges 02 Nos, tower bolt 02Nos anodised aluminium snap beading screws etc with powder coating of any colour (thickness of powder coating not less than 50 micron) complete.
19S&F aluminium anodised grill diamond shape 100 mm x 100 mm aperture of 6 mm dia round bars including necessary joining cleats, clips anodised aluminium snap beading screws complete all as specified as directed by Engineer-in-Charge.
20S & F pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 105X60mm all as specified.
21M&L Cement concrete 1:3:6 type C-1 (using 20mm graded aggregat)e for filling of pressed steel fram and hold fast blocks etc all as specified .
22S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
23S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane all as specified.
24S & F Aluminium, anodised, barrel tower bolts,of extruded section and fixed length of bolt 200mm long all as specified .
25S & F Aluminium handle cast type anodised, 150 mm long all as specified .
26S & F Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed not less than 12mm bore, length o
27S&F MS butt hinges, medium weight cold rolled 100mm size all as specified .
28Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), remving serviceable tiles to stores and and rubbish off the permises.
29M&L glazed ceramic coloured (light colour as approved) 350x250x7/450x350x7mm thick on vertical surface such as skirting / dados set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over & including screedof 15 mm thick rendering in cement mortar (1:4) complete all as specified.
30M&L for joint free Non skid ceramic coloured tile 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floorsetc.over and including 15mm thick screed and bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or colour cement to match with the existing surfaceetc all as specified.
31Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified.
32M & L rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement all as specified.
33M & L rendering 15mm thick on fair faces of brick work in CM 1:4 finished even & smooth without using extra cement all as specified.
34M & L 5mm thick rendering in Cement Mortar 1:3 to ceiling surfaces finished even and smooth without using extra cement complete all as specified.
35Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc.
36M&L Granite 20mm thick(of any type) works (table rubbed and polished) in step, window cills, cooking platforms and the like in cement mortar (1:4),Screed bed 20 mm thick including pointing in white cement (1:2) using marble dust with admixture of pigments to match
37Shotcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mmaverage thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge.
38S&FHard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemntall as specified & directed by Engineer-in-Charge.
39M&L Rough cast plaster as specified. Note:-rendering coat not less than 10mm thick in Cement Mortar 1:3, while it is stell in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. Size 6 to 12mm mixed with coarse sand and cement in the ratio 1:1:1 shall be applied and finished even.
40M & L two coats of cement base paint over a coat of white wash to newly plastered wall surface including preparation of surface complete all as specified .
41M & L Preparation of newly plastered wall surfaces and applying threecoats of white wash including preparation .
42M&L three coat of white wash on ceiling including necessary preparation of surface
43M & L providing two coats of synthetic enamel paint over new wdn surface including preparation of surface withprimer all as specified.
44M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth all as specified.
45Taking down steel tubing 15mm bore and connections complete all as specified.
46Fixing only tubes any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified.
47S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified.
48Taking down steel tubing 20mm bore and connections complete all as specified.
49Fixing only tubes any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified.
50S & F 20mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified.
51Taking down steel tubing 25 mm bore and connections complete all as specified.
52Fixing only tubes any grade 25mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified.
53S & F 25mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified.
54S&F in repair bib taps15mm bore dia, fancy type, cast copper alloychromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified.
55S & F in repairs 15mm bore CP Angle cock one waychromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified .
56S & F in repairs 15mm bore stop valve, cast copper alloy fancy type chromium plated with long shank and cup ( concealed type ) screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed .
57S&F Stop valve 25 mm bore,cast copper alloy, screwed down ,high presuure ,with crutch or butterfly handles , screwed both ends for iron pipe or for unions and fixed as specified.
58Dismantling brick tiles in floor or in roofs laid dry and pointed in cement mortar all as specified.
59Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer -in-charge.
60Providing and applying microfibre reinforced UV resistant Acrylic polymer coating three coats having solid contents 69% polymer content 35% & tensile strength 2.6 N/mm2 of Dr. Fixit Newcoat/stat/Parex or equivalent with a paint brush over existing roof surface after removal of all loose material, lime dust etc. with wire brushes, coir brushes from roof surface to get absolutely cleaned surface free of foreign contaimnant filling of cracks wherever found with polymer based mortar, and after repairing the surface apply primer coat with Dr. Fixit Primeseal.Polyester reinforced fiber net laid on the surface after the first coat and all the joints of bricks is repaired by polymer based mortar. Undulation on the surface repair before executing the water proofing treatment including 15mm thick plaster in CM 1:4 as screed finished even joint of slab and wall of roof complete all as specified and directed by Engineer-in-Charge.
61S&F vitreous china Half stall urinals flat back white minimum with grating and union for discharge pipe ,providing & fixing plugs, bedding urinal against wall in CM 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified.
62S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm all as specified .
63S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified.
64S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete(1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishingall as specified.
65S & F in repairs vitrous china oval wash hand basin white of size 550X400 mm including brackets 300mm long PVC connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etccoloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified .(MAKE- Hindwareor equivalent in Parryware)
66S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excludin fixing bolts, flushing cistern and flush pipe) with PVC sheet cover & "P" OR "S" trap complete all as specified and directed by Engineer -in-charge.
67S&F in repair Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed by Engineer -in-charge.
68S & F Jet spray assembly with all fittingd in EWC all as directed
69S & F soap dish fixed as chromium plated brass.
70S & F in repair5.50 mm thick beveled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed with wooden plugs with chromium plated brass screws and cup washers all as specified..
71S & F stainless steel tubular towel rail 20mm dia 600 mm long in repair complete all as specified and as directed.
72S&F peg set of stainless steel solid body of 125mm to 175 mm having 6 Nos hooks fixed with brass chromium plated screws complete in all as specified
73S & F in repairs swivel shower for PTMT with shower arm 195mm long with bend of 45 degree 15mm dia (minimum weight 80 gms) all as specified.
74S&F high density polyethylene (LDPE) pipes 40mm of presure rating 6kgf/sqq. cm
75Dismantling water tanks of Exc 500 Exc 1000and removing to store.
76S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 1000 Litres all as specified and directed by Engineer - in - Charge .
77M&L Ball brass valves 20mm, high pressure, with polythene float and fly nut complete, screwed for iron pipe of following description :-.
78S & F in repair 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified .
79M&L for water proofing treatment for RCC sunken slab(not exceeding 45cm depth of sunken) as specified below and as directed by Eng in charge.- (a)15mm plaster in cm 1:3 with WPC on raised vertical surface (b) cleaning the surface with wire bruse/coir brush, removing lose material like dust particals, dirt etc. (c) Creating fillet covering of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply frist coat of two component modified polymer coating on the horizontal and vertical surface (e) provision of glass fiber mesh of 2x2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) laying concrete 1:4:8 over the coating as per requirement (h) joining the sanitery pipes with the waterproofing tape having bridging ability of more then 1.5mm (j) filling the gap between the wall opening and sanitery pipe with non shrink cementatious grout (k) Complete the treatment to be carried out by authorised applicatir of waterproofing manufacturer. Make:- Dr. Fixit/ Fosroc/BASF/STP . Note: (i) the treatment shall be carried out as per themanufacturer instruction and as directed by the Eng in Charge. (ii) The plan area of floor shall be considerd for payment. (iii) Cost of WPC @ 3% by wt of cement is included in the unit rate of item.
80Providing 100mm cement concrete Type E-2, 1:5:10 (40 mm graded stone aggregate as in foundation, filling and mass concrete).
81Dismantling wrought iron or mild steel work of any description all as specified.
82S & F framed work such as grills,cooler stand ,grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming toFe 410-0 or Fe 310-0 all as specified .
83Dismantling CI or PVC pipe alongwith fittings of 50/75/100mm dia,below or above GL or laid in floors or fixed to walls jointed in cement mortar and taking out complete all as specified
84S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls ..
85S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls .
86S&F for 110mm bore PVC (SWR) bends any radious provided with access door .
87S&F for 75mm bore PVC (SWR) bends any radious provided with access door .
88S&F for 110mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with access door .
89S&F for 110mm bore PVC (SWR) junction double, (double T) equal or unequal provided with access door .
90S&F for 75mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with access door .
91S&F for 75mm bore PVC (SWR) junction double, (double T) equal or unequal provided with access door .
92S&F for 110mm bore PVC(SWR) Vent cowl
93S&F for 75mm bore PVC(SWR) Vent cowl
94S&F for 75 mm bore PVC (SWR)floor trap with grating including jointing with solvent cement.
95S&F for 110mm PVC Nahani trap with grating including jointingand fixed in cement concrete type B-1, 1:2:4, 100 mm dia.
96Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil
97All as per ser item 1 butdepth 1.50 m to 3.00 m of soft and loose soil
98M&L PCC1:4:8 type D-2(40mm graded aggregatein foundations, filling and mass concrete .
99M&L Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius , built incement mortar 1:4complete all as specified and directed
100M&L rendering 15 mm thick on fair faces of brick work of concrete surfaces cement mortar 1:4with using WPCcomplete all as specified and directed
101Supply only integral waterproofing compound
102M& L PCC 1:2:4 type B1, using 20 mm graded agg.as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses lacing courses, parapets and railing upto 60cm in height coping, Kneelers apex stones, bed plates ,water troughs and loke including weathering , slightly rounded or chamfered angles and throating , as directed , hold fast blocks etc.
103Hard core of broken bricks of gauge not exceeding 63mm, deposited,spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface.
104M & L two coats of cement base paint over a coat of primerto newly plastered wall surface including preparation of surface complete all as specified .
105Returning ,filling in , including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed
106Removing excavated material exc 250m but not n exc 500 m and depositing where directed
107M&L PCC1:2:4 type B-1 (20 mm graded aggergate)100 mm thickfinished cement concrete surface even & smooth with using extra cement etc all as specified .
108M&L for 40mm thick cement concrete type B1 1:2:4 (20mm graded aggregate( as in proof padding, surface finished even and smooth with using extra cement.
109SCHEDULE "A" SECTION-II (E&M PORTION)
110Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out comlete all as specified.
111Returning , filling in including, spreading , levelling , wateringand well reamming in layers not exc comlete all as specified.
112Removing excavated material n exc 50m and depositing where as directed at a level n exc. 1.5 m above the starting point comlete all as specified.
113Sand filling under flooors or in foundation including and consolidation as as specified and directed at site comlete all as specified.
114M & Lbrick sub class "B" locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed.
115Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 4 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/through pipesincluding provision of cable gland/aluminium lugscomplete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
116Taking down carefully copper /aluminium point wiring (light ,fan ,socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and as directed.
117M & L point wiring (Concealed) with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly withcopper lugs inserted in includingMS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, complete all as directed for the following.
118One light/Bell/fan point controlled by one way switch 5 Amp.
119one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq mm size complete.
120one 3 pin socket outlet, 5 Amps on independent board with other switches, with cables 1.5 sq mm size complete.
121Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
122Description all as per item No 08 here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
123M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100V grade in Existing concealed conduit,and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly withcopperincluding provn of of 1.2 mm thick pressed steel sunken terminal boxes 60mm deep suitable lenth and painted with red oxide primer in place of unserviceable shunken box complete for housing switches, , regulators, bell push etc, complete all as directed for the following.
124One light / fan point controlled by one waypiano switch 5 Amp.
125One socket point 5 Amp on an independent board.
126One socket point 5 Amp on same board
127Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
128S & Fswitch piano ,flush type single pole, one way 5 amp, 2way 5 Amp,/bell push all as directed.
129S & Fswitch piano ,flush type single pole, one way 6/15 Amps 5 pin complete all as speccified aand directed.
130Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete.
131Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete.
132M & L for celling rose 3 pin/pvc/ polycarbonate isolated body complete all as specified and as directed.
133M&L for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LEDincluding electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska SSK-SQ2001 20W or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
134Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron of 4 sqmm SWG earht wire fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade withsocket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etcall as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level.(ii) GI strip upto DBs earth connection is included in this item. (iii)GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
135S&F sheet metal enclouser TPN DB having facility to fix MCCBincomer upto 125Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
136S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways s all as specified and directed by Engg-in-Charge.
137S&F MCB SPN 63 Amps, 240 Volts complete all as specified.
138S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified.
139M&L forsubmain wiring comprisingsingle core ,2 Runs of 10 sqmm nominal cross sectional areamultimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 25 mm dia complete,including provision of 2x6 sqmm nominal cross sectional areamultimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earthwire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
140Description all as per item No140 here in before but,2 Runs of 6 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earthwire completeall as specified and directed.
141Description all as per item No140 here in before but,2 Runs of 4 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earthwire completeall as specified and directed.
142M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge .
143S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
144Supply and fixing MCCB TPN ( 4 pole) 63 Amps 415 Volts of braking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting)complete taking down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC solutions complete all as specified and directed. Make :IndoAsian Cat No: 830330 to 830335 or equvalent of Havells/LegrandSchneider/HPL/Standard
145S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge.
146Taking down/ dismantling complete exhaust fan of size 300/380/450 mm sweep.with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of Exhaust fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs:-(a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete exhaust fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :-Ball bearing and Gun metal bush are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in Schedule Items)
147S&F for Condenser 2/2.5 MFD.(Make : Universal (metal body).
148S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
149Supply only ball bearing number of 6201/6202/6203/6204 as required. (Make : SKF/NBC).
150Supply only gun metal bush as required.
151Taking down/dismantling complete exhaust fans of any size for spray painting with two coat ofsynthetic enamel paint of approved colour including filling cavities with filler on coat after cleaning all dust etc. including re-assembling the same and testing after writing of MES NO on completion.
152S&F batton holder insulated body with back plate inluding 12 watts LED lamp complete all as specified.
153S & F GI tube light grade galvanised of size 40 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge. (MAKE: JINDAL/PRAKASH/SURYA)
154M&L for LED Batten with LED tube lightintegrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engr-In-charge. Make: Bajaj BCLSB 10WH or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Syska/Polycab as recommended by Engr-Incharge and approved by GE.
155M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge.
156Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
157S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water.
158S&F for copper (CP) hot water pipe 450 mm length (heavy duty) for Geyser, connection with check nut and washer.
159Taking down/ dismantling of defective/rusted storage type hot water Geyser of 50/35/25 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing etc.Checking defects, re-assembling and re-installing the Geyser in position, connection and testing complete.
160M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed.
161S & Laid G I Pipe 50 mm "Medium Grade with all fittings complete all as specified.
162S & Laid G I Pipe 15 mm "Medium Grade with all fittings complete all as specified.
163S & F Gun metal , Glove or Gate valves 50 mm(2") with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed by Engr-in-charge.
164S & F Gun metal , Glove or Gate valves 15 mmwith iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed by Engr-in-charge.
165Supply and fixing foot valve of size 50 mm. complete all as specified and directed by Engr-in-charge.
166S & F Self priming non clog monoblock pump set ,3 phase , 440 volts, rpm 1500, protection class IP 44, discharge flow rate 210 LPM, head range 10 to 18 mtr, suction & discharge delivery 50 x 50, model SP 3 LM + 3 PH of capacity 5 HP. Complete all as specified and directed by Engr-in-charge.
167S & F Star delta startor , 3 phase, 415 Volts for 5 HP motor complete all as specified and directed by Engr-in-charge.
168Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-1554 cross sectional area 10 Sqmm 3 core including thimbles/lugs completewith & including passing through pipe along wall, under road crossing/Nallah/Under flooretc allas specified and direcated by Engr-in-Charge (Note:-Earth work, sand cushioning , GI Pipe protection & brick protectionto be measured and paid separately)